• 제목/요약/키워드: wind tower generator

검색결과 47건 처리시간 0.029초

1kW 소형 풍력발전기의 진동 성능 모니터링 (Vibration Performance Monitoring of a 1kW Small Wind Turbine Generator)

  • 김석현;남윤수;유능수;박무열;김태형;박해균
    • 산업기술연구
    • /
    • 제26권A호
    • /
    • pp.75-80
    • /
    • 2006
  • A vibration monitoring is performed on a 1kW class stand alone wind turbine(W/T). When a W/T model is developed, general performance under various wind condition should be verified to introduce the product in the market. Especially, vibration characteristics within operating speed range are very important in the aspect of structural stability as well as generator's electrical efficiency. This paper examines the vibration performance of a home made 1kW W/T. Various data of the W/T model are acquired in real time using a remote vibration monitoring system installed in Daekwanryung test site. Vibration stability of the W/T structure is diagnosed based upon the data and the result is used to estimate the applicability of the W/T model.

  • PDF

공중 풍력발전 기술개발 현황 및 시장전망 (Technical Development Status and Market Prospects for High Altitude Wind Power Generation System)

  • 강승원;길두송;박동수;정원섭;김의환
    • 신재생에너지
    • /
    • 제7권2호
    • /
    • pp.36-42
    • /
    • 2011
  • The wind speed at the altitude around 300 m is much higher and less variable than at the altitude around 80 m which is the same height of the MW class tower turbine's hub height. The wind power density is increased 0.37 W/$m^2$ per meter at the altitude around 6 to 7 km and 0.25 W/$m^2$ per meter at the altitude around 80 to 500 m. There are two types of power generation systems using lifting bodies. The one is that The generator is installed in the ground station and stretched into the lifting body through the tether. The other is that the generator is installed in the lifting body and stretched into the ground station through the tether. Many kinds of lifting bodies are also researched in the world, called kites, wings, single or twin aerostat, and so on. This article introduced the technical development status and the market prospects of the high altitude wind power generation system all over the world in detail.

중형 풍력터빈의 출력 및 타워 하중저감 제어기 설계 (Design of Power and Load Reduction Controller for a Medium-Capacity Wind Turbine)

  • 김관수;백인수;김철진;김현규;김형길
    • 한국태양에너지학회 논문집
    • /
    • 제36권6호
    • /
    • pp.1-12
    • /
    • 2016
  • A control algorithm for a 100 kW wind turbine is designed in this study. The wind turbine is operating as a variable speed variable pitch (VSVP) status. Also, this wind turbine is a permanent magnet synchronous generator (PMSG) Type. For the medium capacity wind turbine considered in this study, it was found that the optimum tip speed ratios to achieve the maximum power coefficients varied with wind speeds. Therefore a commercial blade element momentum theory and multi-body dynamics based program was implemented to consider the variation of aerodynamic coefficients with respect to Reynolds numbers and to find out the power and thrust coefficients with respect tip speed ratio and blade pitch angles. In the end a basic power controller was designed for below rated, transition and above rated regions, and a load reduction algorithm was designed to reduce tower vibration by the nacelle motion. As a result, damage equivalent Load (DEL) of tower fore-aft has been reduced by 32%. From dynamic simulations in the commercial program, the controller was found to work properly as designed. Experimental validation of the control algorithm will be done in the future.

SODAR관측을 통해 분석한 도심지 상층의 풍력자원 특성 (The Characteristics of Wind Power Resource in Urban from SODAR Observation)

  • 이화운;박순영;김동혁;전원배;차영민;김현구
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.557-560
    • /
    • 2009
  • When we urgently need to develop and supply an alternative energy, wind power is growing with much interest because it has relative low cost of power and area of tower. To estimate the wind power resource, it is necessary to make an observation first. Although the large wind falm and resources are near coast and mountain area, the wind energy in urban area has the strong thing of direct access to power generator. In this study, we estimate the probability of wind energy above urban area using SODAR data, which is located at the top of the tall building (140m).

  • PDF

Evaluation of wind loads and wind induced responses of a super-tall building by large eddy simulation

  • Lu, C.L.;Li, Q.S.;Huang, S.H.;Tuan, Alex Y.;Zhi, L.H.;Su, Sheng-chung
    • Wind and Structures
    • /
    • 제23권4호
    • /
    • pp.313-350
    • /
    • 2016
  • Taipei 101 Tower, which has 101 stories with height of 508 m, is located in Taipei where typhoons and earthquakes commonly occur. It is currently the second tallest building in the world. Therefore, the dynamic performance of the super-tall building under strong wind actions requires particular attentions. In this study, Large Eddy Simulation (LES) integrated with a new inflow turbulence generator and a new sub-grid scale (SGS) model was conducted to simulate the wind loads on the super-tall building. Three-dimensional finite element model of Taipei 101 Tower was established and used to evaluate the wind-induced responses of the high-rise structure based on the simulated wind forces. The numerical results were found to be consistent with those measured from a vibration monitoring system installed in the building. Furthermore, the equivalent static wind loads on the building, which were computed by the time-domain and frequency-domain analysis, respectively, were in satisfactory agreement with available wind tunnel testing results. It has been demonstrated through the validation studies that the numerical framework presented in this paper, including the recommended SGS model, the inflow turbulence generation technique and associated numerical treatments, is a useful tool for evaluation of the wind loads and wind-induced responses of tall buildings.

LabVIEW를 이용한 풍력발전기 모니터링 시스템 개발 (Development of a Wind Turbine Monitoring System using LabVIEW)

  • 남윤수;김형기;유능수;이정완
    • 한국정밀공학회지
    • /
    • 제20권5호
    • /
    • pp.92-98
    • /
    • 2003
  • A wind turbine monitoring system is essential equipment fur the performance evaluation and mechanical load analysis of a wind turbine. A monitoring system using LabVIEW is developed in this study. This system monitors signals from a meteorological mast, wind turbine generator, and tower. The discrete signals which are sampled at t Hz are automatically saved on a data file in the unit of a day. Besides these basic functions, the developed monitoring system has the other several capabilities. One of them is the information access from a remote PC through the internet. A vision image of the test site area and data files that are produced by LabVIBW software can be uploaded to the main computer located in a remote site. An emergency backup system using UPS fur the power loss on the monitoring HW is also prepared, A detail explanation for the developed wind turbine monitoring system is presented in this study.

선형 전산해석을 이용한 자연 습식 냉각탑의 기하형상에 대한 평가 (Evaluation of Shell Geometry of the Natural Draught Cooling Tower using Linear Numerical Analysis)

  • 노삼영;이상윤;허동현
    • 한국공간구조학회논문집
    • /
    • 제12권3호
    • /
    • pp.97-104
    • /
    • 2012
  • 하이퍼볼릭 쉘로 구성된 냉각탑에서 쉘의 형상은 풍하중에 대하여 냉각탑 전체의 동적 거동에 민감하게 응답한다. 이에 따라 냉각탑 설계 시 기하형상의 결정은 매우 중요하며 일반적으로 고유진동수를 기반으로 하여 산정한다. 본 연구의 목적은 냉각탑 쉘의 구조적 거동에서 형상변수가 미치는 영향을 파악하고자 한다. 기존의 냉각탑 형상변수를 변화시켜 32개의 모델을 선정하였고 이를 1차 고유진동수를 기반으로 하여 분석한 후, 3개의 대표적인 형상을 선택하여 선형 해석을 수행하였다. 그 결과, 전체적으로 작은 반지름을 가지는 기하형상이 높은 1차 고유진동수를 나타내고 풍하중에 대하여 덜 민감한 시스템이 되는 것을 알 수 있었다.

풍력터빈 시스템 성능평가를 위한 NREL 프로그램군에 관한 소개 - 전처리기를 중심으로 (Introduction to the NREL Design Codes for System Performance Test of Wind Turbines - Part I : Preprocessor)

  • 방제성;임채환;정태영
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.41.2-41.2
    • /
    • 2011
  • NREL NWTC Deside codes are analyzed and introduced to develop the system performance simulation program for wind turbine generator systems. In this paper, The AirfoilPrep generating the airfoil data, the IECWind generating hub-height wind data with extreme condition following IEC 61400-1, the TurbSim generating stochastic full-field turbulent wind data, the PreComp calculating structural and dynamic properties of composite blade and the BModes making mode shapes of blade and tower are explained respectively.

  • PDF

부가수질량을 고려한 실린더형 풍력발전기타워의 동적응답연구 (A Study on the Dynamic Response of Cylindrical Wind Turbine Tower Considering Added Mass)

  • 손충렬;이강수;이정탁
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.348-358
    • /
    • 2008
  • Unlike structures in the air, the vibration analysis of a submerged or floating structure such as offshore structures is possibly only when the fluid-structures is understood, as the whole or part of the structure is in contact with water. Through the comparision between the experimental result and the finite element analysis result for a simple cylindrical model, it was verified that an added mass effects on the cylindrical structure. Using the commercial FEA program ANSYS(v.11.0), underwater added mass was superposed on the mass matrix of the structure. A frequency response analysis of forced vibration in the frequency considered the dynamic load was also performed. It was proposed to find the several important modes of resonance peak for these fixed cylindrical type structures. Furthermore, it is expected that the analysis method and the data in this study can be applied to a dynamic structural design and dynamic performance evaluation for the ground and marine purpose of power generator by wind.

  • PDF

바람-파랑 오정렬과 요 오차가 15 MW급 부유식 해상풍력터빈의 출력 성능과 동적 응답에 미치는 영향 (Effect of Wind-Wave Misalignment and Yaw Error on Power Performance and Dynamic Response of 15 MW Floating Offshore Wind Turbine)

  • 이상원;김성건;김범석
    • 신재생에너지
    • /
    • 제20권2호
    • /
    • pp.26-34
    • /
    • 2024
  • Floating offshore wind turbines (FOWTs) have been developed to overcome large water depths and leverage the abundant wind resource in deep seas. However, wind-wave misalignment can occur depending on the weather conditions, and most megawatt (MW)-class turbines are horizontal-axis wind turbines subjected to yaw errors. Therefore, the power performance and dynamic response of super-large FOWTs exposed simultaneously to these external conditions must be analyzed. In this study, several scenarios combining wind-wave misalignment and yaw error were considered. The IEA 15 MW reference FOWT (v1.1.2) and OpenFAST (v3.4.1) were used to perform numerical simulations. The results show that the power performance was affected more significantly by the yaw error; therefore, the generator power reduction and variability increased significantly. However, the dynamic response was affected more significantly by the wind-wave misalignment increased; thus, the change in the platform 6-DOF and tower loads (top and base) increased significantly. These results can be facilitate improvements to the power performance and structural integrity of FOWTs during the design process.