• Title/Summary/Keyword: water control

Search Result 12,102, Processing Time 0.049 seconds

The Sensory and Physico-Chemical of Sous-Vide Cooking Duck Breast Meat (Sous-Vide 조리법을 적용한 오리 가슴살의 관능적 및 품질특성)

  • Ahn, Jong-Sung;Kim, Se-Han;Kim, Na-Yeon
    • The Korean Journal of Food And Nutrition
    • /
    • v.27 no.6
    • /
    • pp.990-998
    • /
    • 2014
  • This study was performed to provide basic data for the sous-vide duck breast by comparing its water content, pH, color, number of microorganism, mechanical quality characteristic test, springiness, and sensory test with its control group which was cooked in traditional way. Sous-vide duck breast brightness, yellowness, and springiness. It l redness, hardness, and number of microorganism than its control group. There was no significant pH difference. Although sous-vide duck breast need longer cooking time, it was softer and had springiness. Overal-vide duck breast longer storage period and than traditionally cooked duck breast in sensory teste expected.

Histopathological Studies on Effect of Dropwort on Cadmium Poisoning in Mice (미나리가 마우스의 카드뮴 중독에 미치는 병리조직학적 관찰)

  • 장종식
    • Journal of Veterinary Clinics
    • /
    • v.16 no.1
    • /
    • pp.13-18
    • /
    • 1999
  • This study was undertaken to find out the effect of dropwort on histopathological changes of cadmium toxicity in mice. Thirty two mice of BALB/c strain were divided into a control group (A) and three experimental groups (B, C, D). Each group was consisted of four males and four females : group A received tap water and basal diet, group B received tap water and diet supplemented with 100 mg/kg of cadmium, group C received dropwort juice and diet supplemented with 100 mg/kg of cadmium, group D received dropwort juice and basal diet. All mice were dissected on the 35th day. Pathological changes in liver, kidney, spleen, heart, lung, stomach and muscle were observed. Group D showed no significant change as the control group. But group B showed many cytoplasmic vacuoles and necrosis of hepatocytes, glomerular swelling, and degeneration and necrosis of convoluted tubules in kidney, marked congestion and hemorrhage, and a large number of variably sized alveolar macrophages appearance in lung and swelling in some part of muscle fiber. On the other hand, group C showed a little convalescent changes and maintained their normal architectures in liver, kidney, lung and muscle.

  • PDF

Multi-level linear Tracking to the Reservoir System Control (저수지 시스템제어에 대한 다단계 선형추적-)

  • 권오헌
    • Water for future
    • /
    • v.17 no.1
    • /
    • pp.37-43
    • /
    • 1984
  • Linear tracking problem I analytically solved with the buadratic performance measure. This theory has the inherent drawbacks in application, because the tracking assumes no boundness of the control and state vectors. The tracking was performed to the discrete system and interrupted subject to the violation. Multi-level tracking was intended based on the concept of the Bellman's Principle of Optimality in this paper. The tracking is iterated to get the desired trajectory which is not known in advance. An application was made to real operation of 6 rervoirs over 36 monthly periods for the Han river.

  • PDF

Performance of a Heat Pump Water Heater with the Variation of Water Flow Rate and Temperature (유량 및 온도제어에 의한 히트펌프 온수시스템의 성능 평가)

  • Yoo, Young-Sun;Kim, Young-Joong;Kang, Geum-Chun;Baek, Yi;Yoon, Jin-Ha
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2001.11a
    • /
    • pp.52-58
    • /
    • 2001
  • 우리나라의 시설농업은 겨울철 난방에 소요되는 에너지원의 대부분을 수입에 의존하는 화석에너지를 이용하고 있다. 따라서 생산비중 난방비의 비중이 국제원유가의 상승에 비례하여 증가하므로서 농산물의 가격이 불안정하며, 결국에는 재배농민의 생산욕구를 저하시켜 농가소득의 감소를 초래하고 있는 실정이다. (중략)

  • PDF

Study on Thermal Crack Control Using Pipe-Cooling in Massive Concrete Foundation of Urban Bridge (파이프 쿨링을 이용한 도심 교량 기초 매스 콘크리트의 수화열 제어에 관한 연구)

  • 이주호;배한욱;우승민;우종일;하봉태;김지상
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.41-46
    • /
    • 2002
  • Recently, the design and construction of massive concrete structures are increased, But, the temperature rise within a large concrete mass makes the construction of massive concrete structures be very difficult. Therefore, various techniques of the thermal stress control of the mass concrete have been widely used. One of them is pipe-cooling which reduces the temperature of concrete with flowing water. It was shown to be possible to construct the massive concrete foundation of urban bridge successfully by application of pipe-cooling system with steel pipe and water circulation. It was also found to expected to make it possible to reduce the probability of thermal crack development in a massive concrete foundation of urban bridge by pipe-cooling system.

  • PDF

A Study on the Fermentation Characteristics of Garbages by the C/N Ratio Control using Kudzu Creeper and Sawdust (칡넝쿨 및 톱밥을 이용한 C/N비 조절에 따른 음식물찌꺼기의 발효특성에 관한 연구)

  • 박진식;안철우;문추연
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.3
    • /
    • pp.24-30
    • /
    • 2000
  • In this study, to determine the optimum fermentation process for the feed production of food wastes and estimate the practical value of fermented feed using kudzu creeper and sawdust as bulking agent. This study considered initial C/N ratio control as the fermentation process variables. The result are summarized as follows. Minimum water contents of byproducts in the fermentation feed production showed 39%(kudzu), 37%(sawdust) at the C/N ratio 25 and 45%(kudzu, sawdust) at the C/N ratio 35. Temperature variations in the fermentation feed production at the C/N ratio 25 indicated $68^{\circ}C$(kudzu), $70^{\circ}C$(sawdust). Optimum condition of fermentation process of water content, C/N ratio and permeability (porous structure of the mixture). For optimum fermentation gravitationally dewatered garbage, the proper mixing ratios of kudzu(moisture contents : 17.3%) and sawdust(moisture contents : 13.2%) were 41% and 39%, respectively. Major biological reaction in the aerobic fermentation feed production occurred during 12~24hrs.

  • PDF

Effects of Liriopis Tuber Extracts on Lipid Metabolism in Rats Fed High Cholesterol Diet (맥문동 엑스가 고콜레스테롤 식이를 급여한 횐쥐의 지질대사에 미치는 영향)

  • Kim, Eun-Jeong;Jeong, Seong-Woon;Yang, Jun-Ho;Lee, In-Sun;Rhee, In-Ja
    • Korean Journal of Pharmacognosy
    • /
    • v.34 no.1 s.132
    • /
    • pp.65-69
    • /
    • 2003
  • This study was performed to examine the effects of Liriopis Tuber extracts to high cholesterol diet on lipid metabolism in rats. Male Sprague-Dawley rats of $90{\pm}10\;g$ were divided into six groups; basal diet (normal group), 1% high cholesterol diet (control group), high cholesterol diet supplemented with 3%, 5% water extracts (C3W, C5W group) and high cholesterol diet supplemented with 3%, 5% MeOH extracts (C3M, C5M group). These experimental diets were fed for 4 weeks. The lipid contents on serum, liver, feces were lower Lriopis Tuber extracts groups than control group. Especially, the effects of water extract was better than MeOH extract.

Effect of Vat Control in Cylinder Machine on Physical Properties of Paper (환망 초지기의 배트 운용이 종이의 품질에 미치는 영향)

  • Park, Yong-Sung;Jeon, Yang;Seo, Yung Bum
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.2
    • /
    • pp.51-57
    • /
    • 2000
  • Cylinder machine usually gives more fiber orientation than fourdrinier and has limitation in machine speed because of fiber wash-off caused by centrifugal force when machine speed increases. This study aimed for the improvement of paper formation and productivity by setting an apron in vat inlet and by adjusting mould water head. Improvement of formation and increase of machine speed were achieved, which ultimately improve productivity. Installing an apron successfully decreased fiber wash-off. Fiber orientation and two-sideness of ash distribution became less severe. The proper adjustment of water head inside the cylinder mould proved to be an important factor not only in paper formation but also in decreasing paper two-sideness.

  • PDF

Errors in Recorded Information and Calibration of a Catchment Modelling System(II) - Monitoring Calibration Approach - (기록치 오차와 유역모형의 검정(II) - 모니터링 검정방법 -)

  • Choi, Kyung Sook
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.5
    • /
    • pp.117-125
    • /
    • 2003
  • Since the recorded information used for operation of a catchment modelling system contain errors that influence the calibration of catchment modelling system control parameter values, the accurate estimation of these parameters is difficult. Despite these influences, existing traditional calibration approaches focus only on achieving the best "curve fitting" between simulated and recorded data, and not on generic evaluation of control parameter values. This paper introduces an Early Stopping Technique which is aimed at avoiding the procedure of curve-fitting through monitoring improvements in the objective function used for assessing the optimal parameter set. Application of this approach to the calibration of SWMM (Storm Water Management Model) on the Centennial Park catchment in Sydney, Australia is outlined. outlined.

Errors in Recorded Information and Calibration of a Catchment Modelling System(I) - Analysis of Measurement Errors in Recorded Information - (기록치 오차와 유역모형의 검정(I) - 기록치 내의 측정 오차 분석 -)

  • Kyung Sook Choi;James E. Ball
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.5
    • /
    • pp.110-116
    • /
    • 2003
  • A catchment modelling system is the summation of the numerous hydrologic, hydraulic and other process models necessary to simulate the response of a catchment to a storm event. Differences between the recorded catchment response and that predicted by a catchment modelling system can arise from structural errors within the catchment modelling system, evaluation errors in the control parameters, or measurement errors in the recorded data being used to assess the reliability of the evaluation of the control parameters. Presented herein is an investigation of the potential measurement errors within the recorded information, which was considered to occur from instrument error in the ultra sonic flow monitor. This investigation was undertaken using three available rating curves at the Musgrave Avenue Stormwater System in Centennial Park, Sydney, developed by Abustan (1997), Water Board (1994), and using Manning's equation.