Characteristics of Wave transmission due to the Variation in the Coss-section of a Waveguide (도파관의 단면 변화에 따른 파동 전달 특성)

  • Kim, Dae-Seung;Kim, Jin-Oh
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1338-1342
    • /
    • 2006
  • This paper presents the theoretical approach to describe the wave propagation in the waveguide with varying cross-section. The waveguides considered in this paper are stepped-rod, tapered-rod, and stepped rod with a tapered section at the middle of wave-transmission. The wave transmission ratio for displacement, stress, and power was calculated for these three rods. The distribution of the stress and displacement along the stepped rod with a tapered section was calculated and compared with the results obtained by FEM analysis.

  • PDF

A Simulation on the Displacement Stress of Cement in Porcelain Insulators for Transmission Line (송전용 자기재 애자의 시멘트 변위 응력에 관한 시뮬레이션)

  • Han, S.W.;Cho, H.G.;Woo, B.C.;Jung, G.C.;Lee, D.I.;Choi, I.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.476-479
    • /
    • 2002
  • The ageing cause in many porcelain suspension insulators which occur on transmission and distribution line with dead-end stings is mechanical stress in interface between porcelain and cement materials. It is known that the principal mechanical stress which give electrical failure is the results of the displacement is due to cement growth. We studied the effect of cement displacement resulting environmental ageing parameters on porcelain insulator mechanical properties for transmission line by simulation (ANSYS/NASTRAN program) and test methods. These simulation analysis and experimental results show that cement volume growth affects severely to be mechanical failure ageing.

  • PDF

Analysis and Improvement of Shielding Effect of Electromagnetic Field in Extremely Low Frequency System (극저주파 시스템에서 전자장 차폐효과 해석 및 개선 방안)

  • Kim, Sang-Hon;Choi, Hong-Soon;Park, Il-Han
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.978-979
    • /
    • 2006
  • Recently, Peoples are exposed the ELF(Extremely Low Frequency) magnetic fields in the vicinity of underground transmission lines, and there are the generally accepted opinion that the magnetic fields affect the human body and there are possibility of the disease. Also in relation to this problem, technical solution methods and research are advanced for reducing the magnetic fields. In this paper, to practically understand the magnetic fields underground transmission lines, We analyze the electromagnetic field distribution in the underground transmission lines by means of FEM(Finite Element Methods) and present that improvement of the effective shielding methods by applying cable arrangements and shielding materials, eddy current problem to the underground transmission lines by means of the numerical analysis Tool.

  • PDF

Measurement and Analysis of Electric and Magnetic Fields Near Overhead Transmission Lines (송전선로의 전자계 크기 측정 및 분석)

  • Kim, Sang-Beam;Cho, Seong-Bae;Shin, Koo-Yong;Lee, Dong-Il;Kim, Jeong-Boo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1908-1910
    • /
    • 1997
  • The electric and magnetic fields (EMFs) near 345/154 kV overhead transmission lines were measured. The average values of maximum electric field and magnetic field for 44 transmission lines were 1.11 kV/m and 24.5 mG, respectively. These values were lower than any standards of advanced countries. The EMFs of distribution lines and substation, and electric appliances were also measured and compared with those of transmission lines.

  • PDF

Measurement and Analysis of Electric and Magnetic Fields near a Transmission Tower (송전철탑 주변에서 전장과 자장의 측정과 분석)

  • Lee, B.H.;Gil, H.J.;Ahn, C.H.;Lee, K.O.;Park, T.W.;Kwak, H.R.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1827-1829
    • /
    • 1997
  • In this paper, measurement and analysis of ELF electric and magnetic fields due to a transmission line have been carried out and the power frequency field strength measuring system is designed. In order to evaluate electric and magnetic fields associated with 60 Hz electric power transmission and distribution lines, the actual survey near a transmission tower has been made and analyzed. It may be inferred from these results that the maximum electric and magnetic fields strength in the vicinity of a line tower do not exceed 3.5[kV/m] and 20[${\mu}T$]. The results of the field measurements agree with limits and guidelines recommended by various authorized international institutes.

  • PDF

Outage Analysis of Cooperative Transmission in Two-Dimensional Random Networks over Rayleigh Fading Channels

  • Tran, Trung Duy;Kong, Hyung-Yun
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.4
    • /
    • pp.262-268
    • /
    • 2011
  • In this paper, we evaluate the outage performance of cooperative transmission in two-dimensional random networks. Firstly, we derive the joint distributions of the source-relay and the relay-destination links. Secondly, the outage probability for the decode-and-forward relaying system is derived when selection combining (SC) is employed at the destination. Finally, we calculate the average outage probability of the system and then attempt to express it by a simple approximate expression. The simulation results are presented to verify the accuracy of the derivations. Similar to deterministic networks, the cooperative transmission in random networks outperforms direct transmission at a high signal-to-noise ratio (SNR).

Effect of Financial Transmission Rights on the Strategic Bidding Behavior of the Electricity Producers (재무적 송전권이 발전사의 전략적 입찰에 미치는 영향)

  • Lee, Kwang-Ho;Shin, Jae-Hong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.7
    • /
    • pp.1226-1231
    • /
    • 2010
  • This paper looks at the influence of Financial Transmission Rights (FTRs) on the market value(Social Welfare; SW) in the competitive electricity market. The transmission line constraints make it difficult to compute the Nash Equilibrium (NE) due to causing a mixed strategy NE instead of a pure strategy NE. Computing a mixed strategy is more complicated in a multi-player game. The aim of this paper are to compute a mixed strategy NE and analyze SW in power transaction with FTRs. This paper introduces a formula and a technique for solving NE of multi-player game with FTRs. In addition, it analyzes the influence of holding of FTRs by generation company on SW and it proposes the SW at NE is influenced by Power Transfer Distribution Factor (PTDF) where holder of FTRs are located. The assertion is verified by calculating the mixed strategy utilizing the Cournot model widely used for studies on FTRs.

Dual-Hop Amplify-and-Forward Multi-Relay Maximum Ratio Transmission

  • Erdogan, Eylem;Gucluoglu, Tansal
    • Journal of Communications and Networks
    • /
    • v.18 no.1
    • /
    • pp.19-26
    • /
    • 2016
  • In this paper, the performance of dual-hop multi-relay maximum ratio transmission (MRT) over Rayleigh flat fading channels is studied with both conventional (all relays participate the transmission) and opportunistic (best relay is selected to maximize the received signal-to-noise ratio (SNR)) relaying. Performance analysis starts with the derivation of the probability density function, cumulative distribution function and moment generating function of the SNR. Then, both approximate and asymptotic expressions of symbol error rate (SER) and outage probability are derived for arbitrary numbers of antennas and relays. With the help of asymptotic SER and outage probability, diversity and array gains are obtained. In addition, impact of imperfect channel estimations is investigated and optimum power allocation factors for source and relay are calculated. Our analytical findings are validated by numerical examples which indicate that multi-relay MRT can be a low complexity and reliable option in cooperative networks.

Design of Planar Microwave Bandstop Filters by Control of Wave Propagation on Nonuniform Transmission Line

  • Park, Eui-Joon
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.5
    • /
    • pp.114-120
    • /
    • 1997
  • A design method is newly presented for the creation of planar type filters which shapes will be nonuniform transmission line with continuously varying characteristic impedances. Those filters yield frequency characteristics of the bandstop filter in transmission, and have not nay discontinuities. The design is achieved by the control of wave propagation in view to both reflection an transmission properties on the dispersive nonuniform line within the desired frequency band. The developed algorithm is based on optimized perturbations of inherent nulls of lobes from the solution of first-order nonlinear differential equation for reflection coefficients of the nonuniform line, and an appropriate distribution of reflection coefficient which affects to filter length and bandwidth. Practical measurements for designed wideband microstrip and stop filter show very good agreement with theoretical results.

  • PDF

CONCEPTUAL DESIGN OF INNER-SPHERICAL CONTINUOUSLY VARIABLE TRANSMISSION FOR BICYCLE USAGE

  • SEONG S. H.;RYU J. H.;LEE H. W.;PARK N. G.
    • International Journal of Automotive Technology
    • /
    • v.6 no.5
    • /
    • pp.467-473
    • /
    • 2005
  • A continuously variable transmission (CVT) with an inner spherical traction drive was conceptually designed for bicycle usage. The range of the overall speed ratio is from 1.0 to 4.5. The rated power and pedal speed are 100 Watts and 6 rad/s, respectively. The peculiar packageability, high-level power efficiency and high torque capacity were considered in the design process. A compact CVT that can be installed within a $244\times125\times160mm^3$ space and is above 0.9 in efficiency for the rated values was numerically designed. The distribution of efficiency according to the input torque and input speed were calculated. Gradeability in the prescribed operation mode was simulated.