• Title/Summary/Keyword: test standard

Search Result 8,477, Processing Time 0.038 seconds

Response Time Index and Suppression Capability of Standard and Quick Response Sprinkler Head (표준형 및 속동형 스프링클러헤드의 반응시간지수와 소화성능)

  • 정길순;이병곤
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.59-70
    • /
    • 1998
  • In this study, response time index(RTI) of standard and quick response type sprinkler head are measured and compared through ramp and plunge test in heated wind tunnel. Also discharge rate and water distribution, actual delivered density(ADD), fire test with wood cribs are performed to compare the fire suppression capability and the operation time and temperature between standard and quick response type sprinkler head.

  • PDF

A Study on the Standardization for Cathodic Protection System and its Testing Method in Korea (국내 전기방식 시스템 및 시험 방법에 대한 표준화 연구)

  • Bae, Jeong-Hyo;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.663-665
    • /
    • 2001
  • Generally, the owners of the facilities adopt CP(Cathodic Protection) Systems to protect the corrosion accidents previously. The developed countries have secured the standard of CP systems and its test methods through the various researches and consolidation of the rules. So, we have been studying the international standards; JSEC, NACE Standard, ASTM, DNV, Australian Standard etc. and standardizing the systems and its test methods to apply in Korea.

  • PDF

A Study on Fire Resisting Construction Design in Advanced Nation (선진각국의 내화설계법에 관한 연구)

  • 김화중
    • Fire Science and Engineering
    • /
    • v.2 no.2
    • /
    • pp.17-30
    • /
    • 1988
  • In Our Country, the fire safety design is done by the standard furnace fire test. This is haphazard procedure, as the standard furnace fire endurance of structural elements has little relation to the structural element endurance in an actual Compartment fire. The standard furnace fire test results, though obtained at great cost, do not contribute to the understanding of the behavior of structural elements in an elevated temperature environment and can not be applied rationally in fire safety design. The response of a steel and reinforced concrete structure in fire is a very complex problem. Therefore, in this paper is explained about tendency of study for fire safety design in advanced nations.

  • PDF

Intercomparison Test of 500 kV Standard Measuring System for SI Voltage (500 kV 표준급 개폐충격전압 측정시스템의 비교시험)

  • Kim, M.K.;Huh, D.H.;Kim, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1492-1493
    • /
    • 2007
  • This paper represents the development of national standard(NS) for switching impulse(SI) voltage measuring system rated 500 kV. A traceability of the NS to the international standard could be achieved by the intercomparison test with PTB(Physikalisch-Technische Bundesansalt). According to the IEC 60060-2, a measurement uncertainty was assessed. As a result of the tests, the measurement uncertainty and the characteristics of step response were satisfied with the requisite for NS.

  • PDF

A Multi Medium Wireless Communication Vehicle Terminal Development and a Performance Test (다매체 무선통신 차량 단말 개발 및 성능평가)

  • Kim, Sang-Heon;Cho, Yung-Sung;Kim, Kyoung-Hwan;Bae, Myoung-Hwan;Lee, Kyeong-Im
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.5
    • /
    • pp.135-145
    • /
    • 2011
  • As communication technology, an enabling technology for ITS, becomes diversified with DSRC, CDMA, Wireless LAN, it is expected that type and function of ITS services will become gradually expanded. As a result, research and development of a standard platform that can provide support so that numerous communication technologies that are being used in various ITS services to receive various ITS services can be operated in one integrated terminal are being carried out. On Board Unit (OBU) for a recent standard platform was also built and tested recently. However, verification for standard suitability of the standard platform OBU that was developed must be carried out. Standard technology must be realized and sufficient functional and operational testing must be carried out in order to guarantee efficient operation in an actual ITS system and increase utilization of standard technology. Therefore, In this paper we had constructed test road and we had tested a standard platform OBU for a standard application.

Domestic Technical Standards and Performance Test of Photovoltaic PCS for Renewable Energy (신재생에너지용 태양광 PCS 국내 기술기준 및 성능시험)

  • Yoon, Yong-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.3
    • /
    • pp.479-484
    • /
    • 2018
  • This paper describes domestic technical standard of Photovoltaic(PV) PCS(Power Conditioning Systems)-Characteristics of the utility interface. This standard tests utility compatibility and personnel safety and equipment protection of PV inverter performance functions. Especially utility compatibility part includes test items of 1)voltage, current and frequency, 2)normal voltage operating range, 3)DC injection, 4)normal frequency operating range, 5)harmonics and 6)waveform distortion, 7)power factor of PV inverter. Therefore in this paper each test item of domestic technical standard is studied and analyzed and finally full tested by PV inverter performance function.

Noise Test and Evaluation of a 750 kW Wind Turbine Generator (750 kW 풍력발전기의 소음 실증)

  • Kim, Seock-Hyun;Kim, Tae-Hyung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.2 s.107
    • /
    • pp.124-131
    • /
    • 2006
  • This study introduces an environmental noise evaluation procedure for wind turbines(W/T) and the evaluation result of a 750 kW wind turbine(W/T) system. Test and evaluation are performed according to the international standard IEC 61400-11 on J48 W/T which is under operation in Daekwanryung W/T test site. With the meteorological data and W/T operational data, noise data are monitored and analysed. An integrated monitoring system is constructed in the test site and is utilized for the evaluation. From the measured noise data, acoustic power level, directivity and tonality of the W/T are estimated under the wind speeds required fly the International standard. The purpose of the study is to establish an W/T noise evaluating system satisfying the international standard and to obtain noise data for home made 750 kW W/T.

Radiation Characteristics of Heavy-weight Floor Impact Sounds in a Standard Test Building (표준실험동에서 중량충격음의 방사 특성)

  • Yoo, Seung-Yup;Jeong, Yong;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.381-384
    • /
    • 2005
  • The purpose of this study is to develop a prediction model for evaluating heavy-weight floor impact sounds in a test building. Three rooms in the test building (slab thickness In and 240mm), which consist of frame concrete structures were tested and modeled. First, the SPL distribution in the receiving room was analyzed by measuring SPL at 90 positions using a bang machine. Then, a vibration model using finite element method is proposed considering the material properties and boundary conditions. In addition, the result of transient analysis was compared with field measurements using a standard heavy-weight impact source. Through a vibro-acoustic simulation program, an acoustic model evaluating the building elements (reflected wall, nor, window and door) was proposed. Finally, validation of the prediction model was conducted by vibro-acoustic analysis with field measurements of noise radiation characteristics in receiving rooms.

  • PDF

A Study on Character of Consolidation for Radial Drainage of Pohang배s Clay Ground (포항 점토 지반의 수평배수 압밀특성 연구)

  • Lee, Song;Jeon, Je-Sung;Kim, Won-Young
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.685-692
    • /
    • 2000
  • Vertical drain used improvement soft clay is made of not only decreasing construction time but also increasing the ground strength during some decades. As, it is applied to improvement soft clay with vertical drain, it is designed by the result that is caused by oedemeter test ignored anisotropic of the ground related to consolidation conditions. When we are expected consolidation conditions, the most important factors is soil of compaction and water permeability. Above all, anisotropic of the ground permeability show the results which differ between vertical and radial drainage. Recently, We study for radial consolidation coefficient and permeability coefficient that utilized Rowe Cell Consolidation and permeability tester but, it dont use well because of not only a supply lack also difficulty of test. The paper experimented with searching anisotropic of the ground so there are Rowe Cell test, standard consolidation tester and modified standard consolidation test that have pohang's soft clay ground. Therefore, we find anisotropic of the ground and a tester of easy use more than before. We made a comparison test result between the devised tester and Rowe Cell tester, Also, we learned average degree of consolidation for partial penetrating vertical drains. We were found relations as effective stress-void and effective stress-permeability coefficient through those tests.

  • PDF

A Standard Test Methods of Resistance to Root Penetration for Waterproofing and Rootproofing Membrane Using Green Roof System (인공지반녹화용 멤브레인 방수 및 방근재료의 방근성능 평가 방법 제안 연구)

  • Lee, Jung-Hoon;Seon, Yun-Suk;Kwak, Kyu Sung;Oh, Sang-Keu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.141-148
    • /
    • 2009
  • The purpose of this paper is to propose a standard test methods of resistance to root penetration for waterproofing and rootproofing membrane using green roof system. Green roof system is considered to be an important subject in construction industry for green growth project. At the same time, we have to consider the counterplan for protection the damage of waterproofing layer and concrete substrate from the penetration of plant root. But many kinds of materials for protection from root penetration are using in construction field. But the performance of those materials is not clear, and there is not test methods for the evaluation of performance. So in this paper, based on the research results of 4 institutes during four years and foreign cases, we made a standard test methods of resistance to root penetration for waterproofing and rootproofing membrane using green roof system. This test method deals with about environmental condition of laboratory, experimental facilities, kinds of plant, specimen of test, management methods, evaluation duration and documents, etc.

  • PDF