• Title/Summary/Keyword: stream flow rate

Search Result 400, Processing Time 0.072 seconds

Development of a Cell-based Long-term Hydrologic Model Using Geographic Information System(I) -Cell-based Long-term Hydrologic Modeling- (지리정보시스템을 이용한 장기유출모형의 개발(I) -장기유출의 격자 모형화-)

  • 최진용;정하우
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.1
    • /
    • pp.64-74
    • /
    • 1997
  • A CELTHYM(CEll-based Long-term HYdrologic Model), a pre-processor and a post-processor that can be integrated with geographic information system(GIS) were developed to predict the stream flow from the small agricultural watershed on the daily basis. The CELTHYM calculates the direct runoff from a grid using SCS curve number method and then sum up all of cells with respect to a sub-catchment area belonged to a stream grid and integrated to an outlet. Base flow of a watershed outlet was computed by integrating of the base flow of each stream grid that was averaged the sub-catchment deep-percolation and calculated with the release rate. Two kind of water budget equation were used to compute the water balance in a grid that was classified into not paddy field and paddy field. One of the two equation is a soil water balance equation to account the soil moisture of the upland, forest and excluding paddy field grid. The other is a paddy water balance equation for the paddy field, calculating the ponding depth, the effective rainfall, the deep percolation and the evapotranspiration.

  • PDF

A Study on Backwashing of Granular Fiters Used in Water Treatment (정수처리를 위한 여과지의 역세척에 관한 연구)

  • Lee, Jung Taek;Ahn, Jong Ho;Choi, Keun Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.3
    • /
    • pp.61-72
    • /
    • 1999
  • To obtain the experimental data for design and operation of actual filtration processes, a sand filter and three kinds of dual media filters in pilot-plant scale were operated in this study. We analyzed the effect of filter medium composition on the filter performance and the effects of backwash water flow rates, length of stream line and air flow rate on the filter backwash efficiency. We also compared the efficiencies of the combined air-water backwashing and the water backwashing in dual media filters. As the backwash water flow rates or the length of stream line increased, the final turbidity of backwash water was decreased and the filtration duration time after backwash was increased. In the case of the combined air-water backwashing, the backwash water quantity needed for backwashing the dual media filters could be decreased. The total volume of filtered water for the dual media filters during filter run was over three times larger than that for the sand filter. The dual media filters could be operated at a high filtration rate of 360 m/day.

  • PDF

Experimental Study on Spray Performance of Nozzles for Autonomous Fire Fighting Monitor (자율형 소화모니터 노즐의 분사 성능에 대한 실험 연구)

  • Rhyu, SeongSun;Kim, HyoungTae;Seo, JeongHwa
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.59 no.2
    • /
    • pp.80-88
    • /
    • 2022
  • A systematic experimental study is carried out for the fire fighting monitor nozzle of 65A diameter to design and manufacture a new nozzle with better water spray performance than available domestic nozzles. The nozzle inlet pressure, flow rate and reach for the discharged water from the nozzle are measured by utilizing the experimental facility consisting of two pumps and piping system with a flow meter and pressure gauges. It was found that the baffle position and baffle head chamfering were the most sensitive design factors to be remarkably changed in the flow rate of the discharged water. Also, It was confirmed that the baffle position and the water exit area had the significant effect on the change in reach distance. The results obtained from this study are expected to be used effectively to design new nozzles with excellent spray performances and also to validate numerical analysis results for evaluating the water spray performance of fire fighting monitor nozzles.

Nitrogen Removal Rate of Free-Water-Surface Treatment Wetland System Constructed on Floodplain During Its Initial Operating Stage (고수부지에 조성한 수질정화 자유수면습지의 초기운영단계 질소제거)

  • Yang, Hongmo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.6 no.6
    • /
    • pp.41-48
    • /
    • 2003
  • Nitrogen removal rate and emergent plant growth were investigated of a free-water-surface constructed treatment wetland system, whose dimensions were 31m in length and 12m in width. The system was constructed on floodplain in the Kwangju Stream from May to June 2001. Cattails(Typha angustifolia) were transplanted from natural wetlands and their stems were cut at about 40cm height from their bottom ends. Water of the Kwangju Stream were funneled into the system by gravity flow and its treated effluent was discharged back into the stream. The average height of the cattail stems was 45.2cm in July 2001 and 186cm in October 2001. The number of stems averaged 22 stems/$m^2$ in July 2001 and 52 stems/$m^2$ in September 2001. Volume and water quality of inflow and outflow were analyzed from July 2001 through December 2001. Inflow and outflow averaged 40.01 and 39.55 $m^3$/day, respectively. Hydraulic detention time was about 1.5 days. Average nitrogen uptake by cattails was 69.31 $N\;mg\;m^{-2}\;day^{-1}$. Removal rate of $NO_3-N$, $NH_3-N$ and T-N averaged 195.58, 53.65 and 628.44 $mg\;m^{-2}\;day^{-1}$, respectively. The average removal rate of T-N was about 39%.

Hydrologic Calibration of HSPF Model using Parameter Estimation (PEST) Program at Imha Watershed (PEST를 이용한 임하호유역 HSPF 수문 보정)

  • Jeon, Ji-Hong;Kim, Tae-Il;Choi, Donghyuk;Lim, Kyung-Jae;Kim, Tae-Dong
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.802-809
    • /
    • 2010
  • An automatic calibration tool of Hydrological Simulation Program-Fortran (HSPF), Parameter Estimation (PEST) program, was applied at the Imha lake watershed to get optimal hydrological parameters of HSPF. Calibration of HSPF parameters was performed during 2004 ~ 2008 by PEST and validation was carried out to examine the model's ability by using another data set of 1999 ~ 2003. The calibrated HSPF parameters had tendencies to minimize water loss to soil layer by infiltration and deep percolation and to atmosphere by evapotranspiration and maximize runoff rate. The results of calibration indicated that the PEST program could calibrate the hydrological parameters of HSPF with showing 0.83 and 0.97 Nash-Sutcliffe coefficient (NS) for daily and monthly stream flow and -3% of relative error for yearly stream flow. The validation results also represented high model efficiency with showing 0.88 and 0.95, -10% relative error for daily, monthly, and yearly stream flow. These statistical values of daily, monthly, and yearly stream flow for calibration and validation show a 'very good' agreement between observed and simulated values. Overall, the PEST program was useful for automatic calibration of HSPF, and reduced numerous time and effort for model calibration, and improved model setup.

Optimization of down stream plasma ashing process (감광제 건식제거공정의 최적화)

  • 박세근;이종근
    • Electrical & Electronic Materials
    • /
    • v.9 no.9
    • /
    • pp.918-924
    • /
    • 1996
  • A downstream oxygen plasma is generated by capacitively coupled RF power and applied to photoresist stripping. Stripping rate (ashing rate) is measured in terms of RF power, chamber pressure, oxygen flow rate and temperature. Ashing reaction is thermally activated and depends on oxygen radical density. The ashing process is optimized to have the high ashing rate, good uniformity and minimal plasma damage using a statistical method.

  • PDF

An easy-to-use design procedure for multipass plate heat exchangers based on the performance plots (성능선도에 의한 다통로 판형열교환기의 간이설계법)

  • 유호선;이근휘;방보청
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.2
    • /
    • pp.250-261
    • /
    • 1999
  • Based on a set of performance plots relating the design variables to the imposed conditions, an easy-to-use and versatile design procedure for chevron-type multipass plate heat exchangers is developed. In order for the present procedure to cover multipass with unequal passes and non-unity ratio of heat capacity rate, each stream number of transfer unit is adopted as the basic design variable instead of the exchanger number of transfer unit. It is found that there exists a unique relation between the stream and exchanger number of transfer units regardless of the chevron angle and the plate length. In addition, for a given value of the pressure drop the heat transfer area per unit mass flow rate can be expressed in terms of the stream number of transfer unit only. These two relationships in the form of simple plots constitute the framework of design. The sample results in comparison with the available data indicate that the present procedure includes the previous ones as a subset, and that every design method is affected essentially by the selection of specific correlations for the heat transfer coefficient and the friction factor.

  • PDF

Computer Simulation of Liquid-Fuelled Combustor in Hot Vitiated-Air Stream (고온.저산소 농도영역중의 분무연소해석)

  • 김태한;최병륜
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.12
    • /
    • pp.3187-3195
    • /
    • 1993
  • Combustion of liquid-fuelled combustion in a high-temperature vitiated-air stream was studied. The mathematical formulation comprise the application of Eulerian conservation equation to the gas phase and Lagrangian equation of droplet motion. The latter is coupled with a droplet-tracking technique (PSI-CELL Model) which regard the droplet phase as a source of mass, momentum, and energy to the gaseous phase. Reaction rate is determined by taking into account the Arrhenius reaction rate based on a single-step reaction mechanism. The calculated profiles show somewhat uncertainess at the upstream, but bases data for designing the combustor followed by 2-phase flow were obtained.

The Characteristics of Water Quality and the Estimation of Pollutant Loadings from the Flowing Streams in Cheju Island (제주도내 유수하천에 대한 수질특성 및 오염부하량 산정)

  • 조은일;오윤근
    • Journal of Environmental Science International
    • /
    • v.7 no.6
    • /
    • pp.845-851
    • /
    • 1998
  • In order to manage the water quality from the flowing streams in Cheju Island, the characteristics of water quality was investigated from August, 1996 to May, 1997 and the pollutant loadings for future were estimated from the watershed at each stream. Comparing the mean concentrations of each water quality with the criterion of water quality in river, it was under I class except for Changgo Stream, for DO, under I class at the whole station for SS and under II class for BOD. As the pollutant loadings at each stream in 2020 is compared with those in 1996, the estimated results are as follows : 1) for BOD, 59% at Donghong Stream, 24% at Yeonoe Stream, 44% at Ohngpo Stream and 57% at Changgo Stream. 2) for T-N, 91% at Donghong Stream, 76% at Yeonoe Stream, 63% at Ohngpo Stream and 89% at Changgo Stream. 3) for T-P, 69% at Donghong Stream, 42% at Yeonoe Stream, 45% at Ohngpo Stream and 73% at Changgo Stream. The point source loadings discharged through combined sewer could be treated at sewage treatment plant. However, the expected slow decreasing rate of BOD, T-N, and T-P loadings is due to the part of untreated nonpoint source loadings. Nonpoint source loading overflow typically occurs when the flow of stormwater combined with sewage exceeds the capacity of the interceptor sewers. Since most of the sewers used in Cheju Island are the combined sewers, the combined overflow sewage is bypassed into the receiving water area after a rainstorm. Therefore, a means to control nonpoint source loadings should be considered for the river and marine water quality management.

  • PDF