• 제목/요약/키워드: sterilizer

검색결과 94건 처리시간 0.022초

ATP Bioluminescence와 간이미생물배지를 이용한 고등학교 급식시설의 위생상태 조사연구 (Evauation of Hygienic Status of High School Foodservice using ATP Bioluminescence Assay & Microorganism Test Strips)

  • 장재선;황성희
    • 한국식품영양학회지
    • /
    • 제28권5호
    • /
    • pp.918-925
    • /
    • 2015
  • An investigation was conducted to evaluate the hygienic status of 33 high school foodservice systems in Yongin city by using hygiene management guide checklist, ATP bioluminescence assay and microbe inspection petrifilm (APC, coliform group, Staphylococcus aureus) of food utensils during use. The 22 hygiene management guide checklist items about facilities, personal hygiene, food control, distribution, washing and disinfection had good grade but there were some inadequate behaviors on observation. The inspection results showed their sanitary condition met the level B of the recommendation of Korea method, it means sanitary management system get settled but more practical CCP system was needed. ATP bioluminescence assay was conducted on surface of food facilities, ATP ranged 425~2,552 RLU on gloves, 541~70,251 RLU on apron, 1,596~88,490 RLU on working desk, 1,177~263,813 RLU on sterilizer grip, 715~32,814 RLU on sterilizer shelf, 114~619,725 RLU on refrigerator grip, 677~319,007 RLU on refrigerator shelf, 71~196,725 RLU on freezer grip, 1,535~233,375 RLU on freezer shelf. APC ranged $66.7{\pm}29.0CFU$ on freezer grip, $102.1{\pm}35.9CFU$ on refrigerator grip, $45.4{\pm}28.2CFU$ on heating cabinet grip, $58.8{\pm}40.4CFU$ on sterilizer grip, the number of coliform group ranged $5.6{\pm}4.9CFU$ on freezer grip, $9.1{\pm}8.7CFU$ on refrigerator grip, $1.2{\pm}1.1CFU$ on heating cabinet grip, $4.5{\pm}4.4CFU$ on sterilizer grip. S. aureus ranged $8.0{\pm}5.6CFU$ on freezer grip, $12.2{\pm}9.6CFU$ on refrigerator grip, $2.1{\pm}1.6CFU$ on heating cabinet grip, $11.6{\pm}6.4CFU$ on sterilizer grip.

관로형 UV 소독기를 위한 세척 및 모니터링 시스템 개발 (The Development of Cleaning and Monitoring System for Pipeline Type UV Sterilizer)

  • 박병준;류지형;박재병
    • 한국산학기술학회논문지
    • /
    • 제14권12호
    • /
    • pp.6434-6440
    • /
    • 2013
  • 본 논문에서는 관로형 UV 소독기의 자동 세척 제어 및 원격 모니터링이 가능한 통합 제어 시스템을 제안한다. 제안한 시스템은 소독기 내 UV 램프 세척 와이퍼의 다양한 세척 동작 제어가 가능하고 UV 센서를 통해 오염도를 주기적 점검할 수 있어 관로형 소독기를 보다 효율적으로 유지, 보수할 수 있다. 또한, 관로형 소독기의 제어기는 개방형 프로세서를 기반으로 하고 있어 외부의 스마트기기와 블루투스 통신을 통해 제어명령 및 센서 정보 등을 주고받을 수 있다. 그 뿐만 아니라 스마트기기를 통해 무선으로 제어기의 펌웨어 업그레이드가 가능하기 때문에 세척 동작 변화 및 각종 센서 장 탈착에 유연하게 대처할 수 있다. 이러한 장점들을 통해 제안한 시스템으로 소규모 마을 등의 스마트 하수 처리 시스템 구축이 가능하다.

밀가루 장기보관을 위한 살균처리 전력변환시스템 (The Power Conversion System of a Sterilizer Processing for the Long Term Storage of Flours)

  • 강욱중;정상화;고강훈;서기영;이현우
    • 조명전기설비학회논문지
    • /
    • 제15권6호
    • /
    • pp.27-34
    • /
    • 2001
  • There are several electricity applied sterilizers such as using high frequency, ozone, high voltage, and so on. Those sterilizers feature "because of no chemical process and no secondly environmental pollution". At the power conversion part, ZVS and ZCS methods have been used that it results in reduced switching loss, miniaturized size, and lightened weight. Besides, the current in the propose device is smaller than that of existing method. Thus, it is expected that the cost of sterilization process, when quality of the device is measured by power consumption, will be reduce. Therefore, the purpose of this research is to solve the sterilization problems of existing powder with high voltage and field to and more economical and effective way, and to suggest mere improved sterilizer.

  • PDF

공진용 인버터 전력 변환 장치를 이용한 플라즈마 살균효과 개선 (The improvement of sterilization effective using resonance inverter Power conversion device)

  • 김주용;김영문;권순걸;이현우;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.266-269
    • /
    • 2003
  • A sterilizer equipment by using electrical energy has merits that no process of chemical and no second environmental pollution. Also, the power conversion circuit for sterilizer equipment has merits that are reducing switching loss for soft switching topology by using zero current and zero voltage switching, and miniaturizing size of equipment. Thus, it is expected that the cost of sterilization process, when quality of the device is measured by power consumption, will be reduced. Therefore, the purpose of this research is to solve the sterilization problems of existing powder with plasma sterilization device, to find more economical and effective way, and to suggest more improved sterilizer.

  • PDF

마이크로파를 이용한 물 살균장치에 관한 연구 (A Study on the Water Sterilizer using the Microwave)

  • 이창호;이화용
    • 대한전자공학회논문지TC
    • /
    • 제41권8호
    • /
    • pp.113-117
    • /
    • 2004
  • 본 논문은 마이크로파를 이용하여 물 살균특성을 실험 조사하기 위해 마이크로파 살균장치를 설계 제작하고, 특성을 실험 한 결과 매우 양호한 효과를 얻었다. 특히 세균 함유량이 많은 하천수를 마이크로파로 10초, 20초, 30초, 40초, 50초, 60초 살균시켜 수질 검사기관에 수차례 검사를 의뢰한 결과 살균한 물의 대장균수와 일반 세균수가 살균 시간에 따라 급격히 감소하는 것을 알 수 있었다.

병원내 공기오염과 물품의 항균에 대한 상태조사 (A Study on the Degree of Contamination of Air and Materials in a Hospital)

  • 차옥주
    • 한국환경보건학회지
    • /
    • 제8권1호
    • /
    • pp.25-30
    • /
    • 1982
  • The incidence of hospital infection has been seriously increased in the general hospital in recent years. This study was performed on hospital air and materials in a General Hospital in Seoul from June to December in 1980. The results were as follows: 1. Air sampling was done in multiple strategic areas by exposing standard petridishes for 5 minutes. There was a significant difference of airborne microbe between places. ($F._{99}$ = 3.2, p < 0.01). 2. The mean colony count was 8.6$\pm$6.2 colonies / plate / 5 minutes. 3. Gram stains of colony in air sampling were Gram (+) cocci 66.5%. Gram (+) rod 18.4%, Gram (-) cocci 1.3%, Gram (-) rod 8.7% Fungus 4.5%. 4. For the evaluation of sterilization of steam sterilizer and ethylene oxide gas sterilizer, biological monitoring were done by commercial spore strip. Positive culture was obtained in 2 out of 41 tests on 3 steam sterilizers, and in 3 out of 13 tests on ethylene oxide gas sterilizer. 5. Product sampling and culture were done for 2 kinds of disinfectants and 30 sets of various operation package or dressing materials. Positive culture was obtained in one disinfectants.

  • PDF

치과진료실에서의 감염관리 실태 조사 (A study on the state of infection control in dental clinic)

  • 김경미;정재연;황윤숙
    • 한국치위생학회지
    • /
    • 제7권3호
    • /
    • pp.213-230
    • /
    • 2007
  • The purpose of this study was to examine the state of infection control provided to members of Korean Dental Hygienists Association. The subjects in this study were dental hygienists who attended a symposium on July 1. 2006. after a survey was conducted, the answer sheets from 489 participants were analyzed, and the findings of the study were as follows: 1. Possession of disinfection room was being(72.7%), and person of infection control was zero(52.9%). Number of sterilizer was one(62.2%). 2. As a repetition choice, type of sterilizer was autoclave(97.9%), UV sterilizer(67.4%) and EO gas sterilizer(21.4%). As a repetition choice, infection materials was ethanol(84.1%). 3. Water tube of unit and chair was using of sterilized water(42.9%). Sterilizing of compressed air was no(69.0%). 4. Re-using of disposal was not using(62.5%), re-using disposal was suction tip(28.2%)(repetition choice) 5. In sterilization of instruments, hand-piece was every using time(28.4%), and reamer-file, bur, mirror, pincette, explorer, hand scaler and ultrasonic scaler were high in every using time. 6. Individual protection was high of using, cleaning of hands before treatment was every treatment(87.0%). Type of soap was liquid type in dental clinic(48.2%), infection soap in dental hospital(41.2%) and solid soap in public health center(50.6%). Answered that they need regular oral health education, and 82.9% respondents answered that they need oral health technicians in school. And 87.8% respondents needed individual oral health education for the benefit of better oral health.

  • PDF

가정용 칫솔 UV 살균기의 성능 개선법에 관한 연구 (Studies on the improvement of UV sterilizer for toothbrush)

  • 양은정;이미선;김정우
    • 자연과학논문집
    • /
    • 제11권1호
    • /
    • pp.41-44
    • /
    • 1999
  • 가정용 칫솔 UV 멸균기의 성능을 개선 할 목적으로, 먼저 UV 처리에 따른 칫솔의 멸균효과를 알아보기 위한 실험을 하였다. UV를 5분, 15분, 30분, 60분의 여러 시간동안 처리하여 실험한 결과, 유의성 있는 효과는 15분 후에 나타났으며, 그 때 80% 이상의 세균 치사율이 됨을 알 수 있었다. UV에 장시간 노출될 경우 나타나는 플라스틱의 탈색을 예방하기 위하여 15분 UV 처리 후 2시간의 무처리 시간을 주고, 다시 3분을 처리한 결과, 97%의 치사율을 보임을 알 수 있었다. 한편, 멸균기에서 칫솔 위치에 따른 멸균효과는 UV light를 직접적으로 받는 위치의 칫솔에만 국한되어 멸균이 되어 이의 개선점이 제시되었다.

  • PDF

염촉매 전기분해 공기살균기의 효능 평가 (Efficacy and Safety Evaluation of an Air Sterilizer Equipped With an Electrolytic Salt Catalyst for the Removal of Indoor Microbial Pollutants)

  • 유선녕;전호연;김부경;김애리;정경일;전계록;안순철
    • 생명과학회지
    • /
    • 제34권7호
    • /
    • pp.500-508
    • /
    • 2024
  • 최근 현대인들의 다중이용시설 사용 빈도가 증가하면서 실내 공기 질, 특히 실내공기 오염원인 공기매개 전염성 세균 및 바이러스 불안에 대한 관심이 높아져 다양한 형태의 공기청정기와 공기살균기의 보급이 확산되고 있다. 따라서 공기 내 미생물을 살균할 수 있는 기술에 대한 연구 필요성이 대두되고 있다. 본 연구에서는 염촉매 전기분해 공기살균기를 개발하여 공기살균기의 항균활성과 인간 세포주(HaCaT, BEAS-2B, THP-1)에 대한 세포독성을 통한 안전성을 조사하였다. 공기살균기에서 분무되는 증기를 각각 1, 3시간 동안 분무한 결과, Staphylococcus aureus는 각각 24.01, 57.34%, Bacillus subtilis는 10.89, 57.76%, Escherichia coli는 30.79, 36.59%, Pseudomonas aeruginosa는 34.80, 49.51%, Salmonella typhimurium는 39.40, 73.98%, 진균인 Candida albicans는 36.59, 53.05%의 높은 항균활성을 보여 염촉매 전기분해 공기살균기의 살균효능이 모든 종류의 시험균주에서 시간 의존적인 항균활성을 보였다. 공기살균기의 분무액을 0.1, 0.3, 1.0%의 농도로 처리하고 세포 생존율을 측정한 결과, 1.0%의 농도에서도 BEAS-2B 세포는 93.88%, HaCaT 세포는 97.01%, THP-1 세포는 86.56%로 관찰되어 인체 정상 세포주에서는 유의적인 세포독성을 나타내지 않았다. 또한 분무액을 1.0%의 농도로 처리하고 현미경으로 관찰한 세포주의 형태학적 변화, PCR을 이용한 세포사멸관련 유전자(Bcl-2, Bax)의 발현 분석, FACS를 이용한 세포 내 ROS의 생성 변화 등에서 분무액을 처리하지 않은 대조군과 비교하였을 때 유의적인 변화가 없었다. 따라서 시험균주에 대한 항균활성, 3가지의 인간 세포주에 대한 세포독성, 세포의 형태적 변화, 유독한 반응성 산소(ROS) 생성, 세포사멸관련 유전자의 발현 등에서 유의미한 변화가 확인되지 않아 공기살균기의 살균 효능과 사용상 안전성을 확인할 수 있었다. 최종적으로 다중이용시설에서의 공기살균기의 효능을 조사하기 위하여 밀폐된 실내에서 공기살균기를 20시간 동안 가동한 후, 공기 중의 낙하균을 포집하여 배양한 결과, 총세균은 89.4%, 대장균과 진균은 100.0% 제거되는 것을 확인하였다. 결론적으로 개발된 염촉매 전기분해 공기살균기는 인체에 대한 독성이 없으면서 실내 오염원인 미생물들을 효과적으로 제거할 수 있음을 확인하였다.

UV/Ozone 복합 살균기의 살균력 개선 연구 (Improvement of a UV/Ozone Duplex Sterilizer)

  • 지정은;양원균;박은철;김강석;주정훈
    • 한국표면공학회지
    • /
    • 제41권2호
    • /
    • pp.76-82
    • /
    • 2008
  • We investigated sterilization characteristics of UV lights by counting the number of bacteria units with varying sterilization time and distance from the light source. We focused on an idea that UV light of 184.9 nm could generate ozone and developed a new sterilizer. The UV-ozone duplex system sterilized bacteria faster than UV-only sterilizers. To reduce shadowing effects by target objects, we used UV transparent quartz plate as a support and put a reflecting plate. Distribution of UV irradiation intensity and ozone supply were analyzed by a 3D model and measured by a semiconductor UV sensor. But even with an Al reflector, multi-layered pens could not be treated properly from UV irradiation only. Ozone generating lamp could treat more uniformly multi-layered pens with a stirring fan by supplying ozone to shadowed surfaces.