• Title/Summary/Keyword: standard set

Search Result 2,555, Processing Time 0.033 seconds

Assessment of Potential for Liquefaction in the Large Reclamation Site Using GIS (GIS를 이용한 대규모 매립지반의 액상화발생가능성 평가)

  • Kim, Hong-Taek;Yoo, Si-Dong;Park, Sa-Won;Lee, Hyung-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1512-1519
    • /
    • 2005
  • In this study, the potential for liquefaction in the Incheon international airport was calculated by appling the standard penetration test data and laboratory test data to the modified Seed & Idriss(2001) method. The analysis was performed on the non-plastic silty layer and silty sand layer which within the depth of 20m, below 20 of the standard penetration value(N), and the ground water level. Also, each set of data was mapped by using GIS(geographic information systems) and the factor of safety for the potential for liquefaction was obtained by overlapping those layers. As a result, it was found that there exist potential hazard zone for the liquefaction partially. So, the additional detailed assessments for those are thought to be necessary.

  • PDF

Basic Survey for Establishing Regional Air Quality Standards in Gyeongnam (경남 지역 대기환경기준 설정을 위한 기초조사)

  • Park, Jeong-Ho
    • Journal of Environmental Science International
    • /
    • v.29 no.2
    • /
    • pp.191-200
    • /
    • 2020
  • This study provides a basis for research to establishing air quality standards in Gyeongnam. The trends and deviations in air quality concentrations and short-term environmental standards were analyzed. Furthermore, the regional standards and World Health Organization's (WHO) air quality guidelines (AQGs) were taken into account. The annual average PM10 standard for cities anc counties ate 40 ㎍/㎥ and 30 ㎍/㎥, respectively. SO2 and NO2 are achieving national standards and need to be strengthened to the minimum regional standard and WHO AQGs. The PM2.5 standard, which has not reached national standards, needs to be set at the level of national standards, and is also the target level for 2024 of the Gyeongsangnam and national PM2.5 management plans.

The Analytical Bias of Total Hydrocarbon (THC) Measurements in Relation to the Selection of Standard Gas Compound (총탄화수소의 계측에서 표준시료성분의 선택에 따른 오차 발생 연구)

  • Kim, Ki-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.4
    • /
    • pp.449-452
    • /
    • 2010
  • In this article, the performance of the THC analyzer was inspected using two different span gases of methane ($CH_4$) and propane ($C_3H_8$). To explore the effect of standard gas selection, MicroFID system was tested by the following procedures. Initially, the system is spanned by propane gas of 60 ppm (or 180 ppmC). The system is then run against methane standards prepared at 5 different concentrations of 200, 250, 300, 400, and 500 ppm. According to the suggestion of the KMOE's test procedure to use multiplying a factor of 3 (for propane), the resulting THC values derived by methane standards were systematically biased with ~500% error relative to true value. This paper discusses the interpretation procedures to obtain the least biased THC values for a given span set-up.

A Study on the Performance Improvement of exterior window by the allowance of expanding a balcony space (발코니 확장(擴張) 허용(許容)에 따른 외부창호(外部窓戶) 성능(性能) 개선(改善)에 대한 연구(硏究))

  • Lee Jong-Il
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.05a
    • /
    • pp.103-105
    • /
    • 2006
  • The revised legislation is introduced that the extension of the balcony area for the apartment houses is allowed. In the past the tenants had to install them illegally by themselves when they wanted to extend their balcony. We have reviewed the standard of the balcony's windows to be set up for them because the contractors can construct the exterior windows. At present, the detailed capacity standard for them is not established Of course some items of them are classified within five capacities among the KS standards. But the standard of the extensional balcony windows are not defined. Therefore this study is aimed at setting up the criteria of the noise, insulation and leak for the window system in expanding the balcony area and adopting it into window's works.

  • PDF

An Experimental Study on Thermal Resistance of Large-scale Specimen Using KS F 2278 (KS F 2278을 적용한 대면적 시료 열관류율 시험 실측에 관한 연구)

  • Moon, Jae-Sik;Lee, Won-Gyun;Kim, Young-Bong;Cho, Byoung Young;No, Sang-Tae
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.306-307
    • /
    • 2018
  • In Korea, The thermal resistance test of window sets is performed according to KS F 2278 standard, and is performed only on a specimen size of 2000 × 2000 (mm). In this study, a standard panel measuring 4000 × 3000 (mm) size was used to measure the heat flux in each part of the specimen, and to calculate the resistance to heat transfer And to seize whether the KS F 2278 standard is applicable to large Specimen.

  • PDF

Derivation of the Standard Design Guidelines for Crashworthiness of the High-Speed EMU (동력분산형 고속전철의 충돌안전도 설계 가이드라인 도출)

  • Kim, Geo-Young;Cho, Hyun-Jik;Koo, Jeong-Seo
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.772-779
    • /
    • 2008
  • Through this study, standard design guidelines for the high speed EMU have been derived to meet the crashworthiness requirements of the Korean rollingstock safety regulation. The crashworthiness regulation requires some performance requirements for two heavy collision accident scenarios; a train-to-train collision at the relative speed of 36 kph, and a collision against a standard deformable obstacle of 15 ton at 110 kph. The complete train set will be composed of 2TC-6M with 13 ton axle load, different from KTX with the power car of 17 ton axle load. Using theoretical and numerical analyses, some crashworthy design guidelines were derived in terms of mean crush forces and energy absorptions for main crushable structures and devices. The derived design guidelines were evaluated and improved using one dimensional spring-mass dynamic simulations. It is shown from the simulation results that the suggested design guidelines can easily satisfy the domestic crashworthiness requirements.

  • PDF

A Novel OLED Inspection Process Method with Simultaneous Measurement for Standard and Deposition Pattern (기준패턴과 증착패턴의 동시 측정을 통한 OLED 공정 검사 방법)

  • Kwak, Byeongho;Cheoi, Kyungjoo
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.15 no.4
    • /
    • pp.63-70
    • /
    • 2019
  • The subject of the simultaneous measuring system of base pattern and deposition pattern is a new research topic on a defect inspection of OLED. In this paper, we propose a new OLED inspection method that simultaneously measures standard and deposition pattern images. This method reduces unnecessary processes and tac time during OLED inspection. For an additional reduction of the tac time during pattern measurement, the ROI was configured to measure only in the designated ROI area instead of measuring the entire area of an image. During the ROI set-up, the value of effective deposition pattern area is included so that if the deposition pattern is out of the ROI zone, it would be treated as a defect before measuring the size and center point of the pattern. As a result, the tac time and inspection process could be shortened. The proposed method also could be applied to the OLED manufacturing process. Production of OLED could be increased by reducing tac time and inspection process.

Study on the Calibration System of Flow Meters in Partly Filled Pipes (비만관 유량계 교정 시스템 구축에 관한 연구)

  • Yoo Sung-Ho;Lee Dong-Rak;Lee Min-Soo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.4 s.37
    • /
    • pp.7-12
    • /
    • 2006
  • Flow meters in partly filled pipes are set up and run in Korea nowadays, but there are no standard calibration procedures for the flow meters in accordance with ' ISO/IEC 17025. The standard calibration procedure based on the standard calibration procedures for flow meter in closed conduits and the technical notes of flow meter's makers ' is developed. The measurement uncertainty of the calibration for the flow meter in partly filled pipes is evaluated.

A New Hybrid Coder for High Quality Image Compression

  • Lee, Hang-Chan
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.6
    • /
    • pp.36-42
    • /
    • 1997
  • This paper presents a new design technique for performing high quality low bit rate image compression. A hybrid coder(HC) which combines Mean Removed Important Coefficient Selection based JPEG(MR-ICS-JPEG) and Adaptive Vector Quantization (AVQ) is proposed. A new quantization table is developed using the Important Coefficient Selection(ICS) method; the importance of each coefficient is determined using the orthonormal property of the DCT. This quantization table is applied to standard JPEG with mean removal(MR) strategy before processing. This scheme, called MR-ICS-JPEG, produces more than 2 dB enhanced performance in terms of PSNR over standard JPEG. A set of homogeneous codebooks is generated by homogeneous training vectors. Before compression, an image is uniformly divided into 8${\times}$8 blocks. Low detail regions such as backgrounds are roughly coded by AVQ while high detail regions such as edges or curves are finely coded by the proposed MR-ICS-JPEG. This hybrid coder procuces consistently about 3 dB improved performance in terms of PSNR over standard JPEG.

  • PDF

Stochastic Model for Unification of Stereo Vision and Image Restoration (스테레오 비젼 및 영상복원 과정의 통합을 위한 확률 모형)

  • Woo, Woon-Tak;Jeong, Hong
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.29B no.9
    • /
    • pp.37-49
    • /
    • 1992
  • The standard definition of computational vision is a set of inverse problems of recovering surfaces from images. Thus the common characteristics of the most early vision problems are ill-posed. The main idea for solving ill-posed problems is to restrict the class of admissible solutions by introducing suitable a priori knowledge. Standard regurarization methods lead to satisfactory solutions of early vision problems but cannot deal effectively and directly with a few general problems, such as discontinuity and fusion of information from multiple modules. In this paper, we discuss limitations of standard regularization theory and present new stochastic method. We will outline a rigorous approach to overcome part of ill-posedness of image restoration, edge detection, and stereo vision problems, based on Bayes estimation and MRF(Markov random field) model, that effectively deals with the problems. This result makes one hope that this framework could be useful in the solution of other vision problems.

  • PDF