• Title/Summary/Keyword: standard of assessment

Search Result 2,352, Processing Time 0.033 seconds

Characterization of Particulates Containing Naturally Occurring Radioactive Materials in Phosphate Processing Facility (인광석 취급 산업체에서 발생하는 천연방사성물질 함유 입자의 특성 평가)

  • Lim, HaYan;Choi, Won Chul;Kim, Kwang Pyo
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.7-13
    • /
    • 2014
  • Phosphate rock, phosphogypsum, and products in phosphate processing facility contain naturally occurring radioactive materials (NORM). Therefore, they may give rise to enhanced radiation dose to workers due to inhalation of airborne particulates. Internal dose due to particle inhalation varies depending on particle properties. The objective of the present study was to characterize particle properties at the largest phosphate processing facility in Korea. A cascade impactor was employed to sample airborne particulates at various processing areas in the plant. The collected samples were used for characterization of particle size distribution, particle concentration in the air, and shape analysis. Aerodynamic diameters of airborne particulates ranged 0.03-100 ${\mu}m$ with the highest concentration at the particle size range of 4.7-5.8 ${\mu}m$ (geometric mean = 5.22 ${\mu}m$) or 5.8-9.0 ${\mu}m$ (geometric mean = 7.22 ${\mu}m$). Particle concentrations in the air varied widely by sampling area up to more than two orders of magnitude. The large variation resulted from the variability of mechanical operations and building ventilations. The airborne particulates appeared as spheroids or rough spherical fragments across all sampling areas and sampled size intervals. Average mass densities of phosphate rocks, phosphogypsums, and fertilizers were 3.1-3.4, 2.1-2.6, and 1.7 $gcm^{-3}$, respectively. Radioactivity concentration of uranium series in phosphate rocks varied with country of origin, ranging 94-866 $Bqkg^{-1}$. Among the uranium series, uranium was mostly concentrated on products, including phosphoric acid or fertilizers whereas radium was concentrated on byproducts or phosphogypsum. No significant radioactivity of $^{226}Ra$ and $^{228}Ra$ were found in fertilizer. However, $^{40}K$ concentration in fertilizer was up to 5,000 Bq $g^{-1}$. The database established in this study can be used for the accurate risk assessment of workers due to inhalation of airborne particles containing NORM. In addition, the findings can be used as a basic data for development of safety standard and guide and for practical radiation safety management at the facility.

Assessment of the Cause and Pathway of Contamination and Sustainability in an Abandoned Mine (폐광산 오염원인 분석 및 오염경로, 향후 지속가능성에 대한 평가)

  • Kim, Min Gyu;Kim, Ki-Joon;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.28 no.3
    • /
    • pp.411-429
    • /
    • 2018
  • Daeyoung mine (also called "Daema mine") produced gold and silver from mainly gold- and silver-bearing quartz veins. The mine tailings are a waste hazard, but most of the tailings were swept away or dispersed throughout the area around the mine long before the tailing dump areas were transformed into agricultural land. Soil liner and protection facilities, such as retaining walls, were constructed in the mine area to prevent the loss of tailings. The content of the tailings is 3,424.41~3,803.61 mg/kg, which exceeds the safety standard by a factor of 45. In addition, contamination was detected near agricultural areas and in the sediments in downstream drainage channels. A high level of As contamination was concentrated near the waste tailings yard; comparaable levels were detected in agricultural areas close to streams that ran through the waste dump yard, whereas the levels were much lower in areas far from the streams. The contamination in stream sediments showed a gradual decrease with distance from the mine waste yard. Based on these contamination patterns, we concluded that there are two main paths that affect the spread of contaminants: (1) loss of mine waste, and (2) the introduction of mine waste into agricultural areas by floods after transportation by streams. The agricultural areas contaminated by mass inflow of mine waste can act as contamination sources themselves, affecting other agricultural areas through the diffusion of contaminants. At present, although the measured effect in minimal, sediments in streams are contaminated by exposed mine waste and surface liners. It is possible for contaminants to diffuse or spread into nearby areas if heavy elements trapped in soil grains in contaminated agricultural areas leach out as soil solution or contaminant particles during diffusion into the water supply.

The Evaluation and Development of Head and Neck Radiation Protective Device for Chest Radiography in 10 Years Children (소아(10세) 흉부 방사선촬영에서의 두경부 방사선 방어기구 개발 및 평가)

  • Lee, Jun Ho;Lim, Hyun Soo;Lee, Seung Yeol
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.118-123
    • /
    • 2015
  • The frequency of diagnostic radiation examinations in medical institutions has recently increased to 220 million cases in 2011, and the annual exposure dose per capita was 1.4 mSv, 51% and 35% respectively, compared to those in 2007. The number of chest radiography was found to be 27.59% of them, the highest frequency of normal radiography. In this study, we developed a shielding device to minimize radiation exposure by shielding areas of the body which are unnecessary for image interpretation, during the chest radiography. And in order to verify its usefulness, we also measured the difference in entrance surface dose (ESD) and the absorbed dose, before and after using the device, by using an international standard pediatric (10 years) phantom and a glass dosimeter. In addition, we calculated the effective dose by using a Monte Carlo simulation-based program (PCXMC 2.0.1) and evaluated the reduction ratio indirectly by comparing lifetime attributable risk of cancer incidence (LAR). When using the protective device, the ESD decreased by 86.36% on average, nasal cavity $0.55{\mu}Sv$ (74.06%), thyroid $1.43{\mu}Sv$ (95.15%), oesophagus $6.35{\mu}Sv$ (78.42%) respectively, and the depth dose decreased by 72.30% on average, the cervical spine(upper spine) $1.23{\mu}Sv$ (89.73%), salivary gland $0.5{\mu}Sv$ (92.31%), oesophagus $3.85{\mu}Sv$ (59.39%), thyroid $2.02{\mu}Sv$ (73.53%), thoracic vertebrae(middle spine) $5.68{\mu}Sv$ (54.01%) respectively, so that we could verify the usefulness of the shielding mechanism. In addition, the effective dose decreased by 11.76% from $8.33{\mu}Sv$ to $7.35{\mu}Sv$ before and after wearing the device, and in LAR assessment, we found that thyroid cancer decreased to male 0.14 people (95.12%) and female 0.77 people (95.16%) per one million 10-year old children, and general cancers decreased to male 0.14 people (11.70%) and female 0.25 people (11.70%). Although diagnostic radiation examinations are necessary for healthcare such as the treatment of diseases, based on the ALARA concept, we should strive to optimize medical radiation by using this shielding device actively in the areas of the body unnecessary for the diagnosis.

The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance (5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구)

  • Jung, Hai-Jo;Kim, Hee-Joung;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • In June 2005, Yonsei University Medical Center, Severance Hospital upgraded a full-PACS system by adding twenty (5 mega pixels) Totoku ME511L flat panel LCD display devices for diagnostic interpretation purposes. Here we report upon the quantitative (or visual) acceptance testing of the twenty Totoku ME511L display devices for reflection, luminance response, luminance spatial dependency, resolution, noise, veiling glare, and display chromaticity based on AAPM TG 18 report. The tools used in the tests included a telescopic photometer, which was used as a colorimeter, illuminance meter, light sources for reflection assessment, light-blocking devices, and digital TG18 test patterns. For selected 8 flat panel displays, mean diffuse reflection coefficient ($R_d$) was $0.019{\pm}0.02sr^{-1}$. In the luminance response test, luminance ratio (LR), maximum luminance difference ($L_{max}$), and deviation of contrast response were $550{\pm}100,\;2.0{\pm}1.9%\;and\;5.8{\pm}1.8%$, respectively. In the luminance uniformity test, maximum luminance deviation was $14.3{\pm}5.5%$ for the 10% luminance of the TG18-UNL10 test pattern. In the resolution test with luminance measurement method, percent luminance (${\Dalta}L$) at the center was $0.94{\pm}0.64%$. In all cases of noise testing, rectangular target In every square in the three quadrants was visible and all 15 targets except the smallest one in the every corner pattern and the center pattern. The glare ratio (GR) was $12,346{\pm}1,995$. The color uniformity, (u',v'), was $0.0025{\pm}0.0008$. Also, the research results of qualify control guideline of primary disply devices suitable for domestic circumstance are presented All test results are in-line with the criteria recommended by AAPM TG18 report and are thus fully acceptable for diagnostic image interpretation. As a result, the acceptance testing schedule described provides not only an acceptance standard but also guidelines for quality control, optimized viewing conditions, and a means for determining the upgrading time of LCD display devices for diagnostic interpretation.

  • PDF

Radiological Dose Analysis to the Public Resulting from the Operation of Daedeok Nuclear Facilities (대덕부지 원자력관련시설 운영에 따른 주민피폭선량 현황분석)

  • Jeong, Hae Sun;Kim, Eun Han;Jeong, Hyo Joon;Han, Moon Hee;Park, Mi Sun;Hwang, Won Tae
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.38-45
    • /
    • 2014
  • This paper describes the results of assessment of radiological dose resulting from operation of the Daedeok nuclear facilities including the HANARO research reactor, which has been performed to assure whether or not to comply with the regulation standards of the radioactive effluents releases. Based on the meteorological data and the radiation source term, the maximum individual doses were evaluated from 2010 to 2012. The atmospheric dispersion and the deposition factors of gaseous effluents were calculated using the XOQDOQ computer code. ENDOS-G and ENDOS-L code systems were also used for maximum individual dose calculation from gaseous and liquid effluents, respectively. The results were compared with the regulation standards for the radioactive effluents presented by the Nuclear Safety and Security Commission (NSSC). The effective doses and the thyroid doses of the maximum individual were calculated at the maximum exposed point in the Daedeok site, and contributions of exposure pathways to the radiological doses resulting from gaseous and liquid radioactive effluents were evaluated at each facility of the Daedeok site. As a result, the maximum exposed age was analysed to be the child group, and the operation of HANARO research reactor had a major effect more than 90% on the individual doses. The main exposure pathways for gaseous radioactive effluent were from ingestion and inhalation. The effective doses and the thyroid doses were considerably influenced by tritium and iodine, respectively. The gaseous radioactive effluents contributed more than 90% on the total doses, whereas the contributions of the liquid radioactive effluents were relatively low. Consequently, the maximum individual dose due to radioactive effluents from the nuclear facilities within the Daedeok site were less than 3% of the regulation standard over 3 years; therefore, it can be concluded that radioactive effluents from the nuclear facilities were well managed, with the radiation-induced health detriment for residents around the site being negligible.

The effect of Neurofeedback training on brain wave activity and cognitive performance in chronic stroke patients (뉴로피드백(Neurofeedback) 훈련이 만성 뇌졸중 환자의 뇌파활성도와 인지수행력에 미치는 효과)

  • Lee, Young-Sin;Kim, Sang-Yeob;Kim, Chan-Kyu;Jung, Dae-In;Kim, Kyung-Yoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2329-2337
    • /
    • 2013
  • This study was done objected to the chronic stroke patients in order to evaluate change in brain wave activity and cognitive performance when Neurofeedback training. The subjects were over 6 months ago in chronic stroke patients screened-test through the 20 patients, 10 persons in each group were randomly placed. This was carried out in 4 weeks in total, with control group(n=10) on general physical therapy and experimental group(n=10) on general physical therapy along with Neurofeedback training. The general physical therapy was applied 5 times a week, 30 minutes at once, Neurofeedback training was applied as equally as the general physical therapy, which makes 20 times in total. To learn about the effect before the training, after training, and 2 weeks after the training in electric physiological measurement method of the brain, electroencephalogram(EEG) to examine challenges by calculating the absolute spectrum power for standard EEG change(%), followed by evaluation with clinical assessment tool MMSE-K, Stroop Test, Digit Span Test. As a result of comparing the change in brain wave through EEG, after training and 2 weeks after training showed that absolute ${\alpha}$-power and absolute ${\beta}$-SMR power of experimental group have increased and absolute ${\theta}$-power decreased significantly compared to experimental group I. Moreover, the MMSE-K score in trial appraisal has increased significantly, and the error in Stroop Test and Digit Span Test has decreased significantly. such results, with the chronic stroke patient's brain wave control, Neurofeedback training was determined to improve the cognitive performance. this study suggests a new training possibility of stroke patients by identifying the training effects of Neurofeedback training that trains the brain directly with brain wave control.

Assessment and Comparison of SUVs of Three Different PET/CT Scanners (장비에 따른 SUV의 차이와 이에 관한 고찰)

  • Kim, Tae-Yeob;Lim, Jung-Jin;Lee, Hong-Jae;Kim, Hyun-Joo;Kim, Joong-Hyun;Lee, Jae-Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.34-38
    • /
    • 2011
  • Purpose: The SUV is a widely used semi-quantitative index in PET for the estimation of radio-tracer accumulation in VOI. In this study, SUVs from three different PET/CT scanners were assessed, and differences between SUVs were evaluated. Materials and Methods: The PET/CT scanners which were assessed in this study were GEMINI, GEMINI TF 64 (Philips) and Biograph True Point True V 40 (Siemens). The NEMA PET phantom (Data Spectrum Corp., USA) was used to evaluate SUVs. The NEMA PET phantom has6.8 kg weight and three hot inserts. Two different activity distributions for the background and inserts were tested. The activity ratio were 3.7:3.7:7.4:11.1 MBq (1:1:2:3) and 1.85:7.4:9.25:11.1MBq (1:4:5:6) for each of background, insert 1, insert 2 and insert 3. Acquisition time was 2 minutes per bed position and NEMA PET phantom could be covered by two bed positions for all PET/CT scanners. The SUVs from each PET/CT scanner were compared with calculated true value. Results: For both activity ratios, all scanners showed similar results. The differences between each scanner were insignificant. Each scanner showed 91.2%, 85.9% and 87.2% of true SUV for GEMINI, GEMINI TF 64, Biograph True Point TrueV, respectively. Conclusion: For all scanners, SUVs were slightly lower than true value. However, the difference between scanners was insignificant. The SUVs from these scanners would be clinically meaningful if their consistent underestimation is kept in mind.

  • PDF

Quantitative Assessment of the Radiation Exposure during Pathologic Process in the Sentinel Iymph Node Biopsy using Radioactive Colloid (방사성 콜로이드를 이용한 감시림프절 생검 병리처리과정에서 방사선 피폭의 정량적 평가)

  • Song, Yoo-Sung;Lee, Jeong-Won;Lee, Ho-Young;Kim, Seok-Ki;Kang, Keon-Wook;Kook, Myeong-Cherl;Park, Weon-Seo;Lee, Geon-Kook;Hong, Eun-Kyung;Lee, Eun-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.309-316
    • /
    • 2007
  • Purpose: Sentinel lymph node biopsy became the standard procedure in early breast cancer surgery. Faculty members might be exposed to a trace amount of radiation. The aim of this study is to quantify the radiation exposure and verify the safety of the procedure and the facilities, especially during pathologic process. Materials and Methods: Sentinel lymph node biopsies with Tc-99m human serum albumin were performed as routine clinical work. Exposed radiation doses were measured in pathologic technologist, nuclear medicine technologist, and nuclear medicine physician using a thermoluminescence dosimeter (TLD) during one month. We also measured the residual radioactivities or absorbed dose rates, the exposure distance and time during procedure, the radiation dose of the waste and the ambient equivalent dose of the pathology laboratory. Results: Actual exposed doses were 0.21 and 0.85 (uSv/study) for the whole body and hand of pathology technologist after 47 sentinel node pathologic preparations were performed. Whole body exposed doses of nuclear medicine physician and technologist were 0.2 and 2.3 (uSv/study). According to this data and the exposure threshold of the general population (1 mSv), at least 1100 studies were allowed in pathology technologist. The calculated exposed dose rates (${\mu}$ Sv/study) from residual radioactivities data were 2.47/ 22.4 ${\mu}$ Sv (whole body/hand) for the surgeon; 0.22/ 0 ${\mu}$ Sv for operation nurse. The ambient equivalent dose of the pathology laboratory was 0.02-0.03 mR/hr. The radiation dose of the waste was less than 100 Bq/g and nearly was not detected. Conclusion: Pathologic procedure relating sentinel lymph node biopsy using radioactive colloid is safe in terms of the radiation safety.(Nucl Med Mol Imaging 2007;41(4);309-316)

Developing Food List for Risk Assessment of Contaminants in Korean Foods (식품으로부터의 오염물질 섭취량 및 위해도 평가를 위한 대표식품 선정)

  • Lee, Haeng-Shin;Kim, Bok-Hee;Jang, Young-Ai;Park, Seon-Oh;Oh, Chang-Hwan;Kim, Ji-Young;Kim, Hee-Yun;Chung, So-Young;Sho, Yoo-Sub;Suh, Jung-Hyuck;Lee, Eun-Ju;Kim, Cho-Il
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.4
    • /
    • pp.660-670
    • /
    • 2005
  • Standard procedure for development of food list was established based on food intake data of 2001 National Health and Nutrition Survey and 2002 Seasonal Nutrition Survey for Total Diet Study. Foods were sorted in descending order of mean intake, and 54 items within cumulative percentage of 80 were selected, followed by selection of 16 additional items with consumption frequency of 10% or higher. Based on higher consumption in certain seasons, regions, sexes, and age classes, 14 additional items were added. Additional 17 items with probable high contents of heavy metals or 23 items with probable high pesticide residues were added. Altogether, 101 and 107 individual food items were included for heavy metal and pesticide residue lists, accounting for 84.9 and 83.3% mean energy intakes of Korean population, respectively.

Monitoring of Lead and Cadmium Contents of Vegetables in Korea (국내 유통 중인 채소류의 납, 카드뮴 함량 모니터링)

  • Shim, Jee-Youn;Oh, Hyun-Suk;Jang, Mi-Ran;Lee, Yoon-Ae;Lee, Ryun-Kyung;Kim, Min-A;Lee, Hyo-Jung;Lee, Sang-Min;Cho, Tae-Youg
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.4
    • /
    • pp.395-401
    • /
    • 2010
  • This research was carried out as a survey on the contents of Lead (Pb) and Cadmium (Cd) in 5 type agricultural products unestablished safety guideline in Korea. The average levels of Pb: onion 0.010 mg/kg, cucumber 0.018 mg/kg, garlic 0.012 mg/kg, green pepper 0.027 mg/kg, sesame 0.029 mg/kg. The average levels of Cd: onion 0.006 mg/kg, cucumber 0.002 mg/kg, garlic 0.008 mg/kg, green pepper 0.011 mg/kg, sesame 0.024 mg/kg. The present result of this study showed that Pb and Cd contents in the whole samples were less than the maximum residual levels of the codex standard. The levels of exposure assessment for Pb and Cd by intake from vegetables and sesame were merely at $1.3{\times}10^{-4}$(mean) ~ $5.1{\times}10^{-4}$($95^{th}$ percentiles) ${\mu}$g/kg bw/day for Pb, $7.5{\times}10^{-5}$(mean) ~ $3.6{\times}10^{-4}$($95^{th}$ percentiles) ${\mu$}g/kg bw/day for Cd. The data from this research will be valuable source for database construction for science-based safety control and management for the trace metal contamination in food including agricultural products.