• Title/Summary/Keyword: signal head

Search Result 414, Processing Time 0.027 seconds

A Study to Acquire Sharp Images in the Haas(Skull PA Axial Projection) (Haas 촬영법에서 선예한 영상 획득을 위한 연구)

  • Ahn, Jun-Ho;Han, Jae-Bok;Song, Jong-Nam;Kim, In-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.319-325
    • /
    • 2022
  • The Study In order to obtain a sharpness Image from Skull PA axial projection (Haas) in a head axial X-ray Examination, this study changed the posture angle using Skull Phantom and evaluated the image subjectively to 5 radiologists who worked in the Department of Imaging at University Hospital. In the prone position, the head was lowered 4 cm from the back of the head, entered 25° toward the head, and the image evaluation score was high with 20 points, such as the back bone, dorsum sellae projected in the large hole, and posterior clinoid process. In addition, the score significance was verified, and the Cronbach Alpha value was evaluated to have good reliability of 0.789. As a result of calculating the signal-to-noise ratio (SNR) by setting the region of interest (ROI) of the image, it was the highest at 5.957 for 25° incident at the back of the head and 6.430 for 30° incident at the back of the head. As a result of the study, in order to obtain a sharp image of the back of the head bone, dorsum sellae, and posterior clinoid process when shooting in the axial direction after the head, it is filmed by tilting 25° toward the head from 4 cm below the back of the head. In order to obtain a sharp image of rock pyramid symmetry, petrous ridge, sagittal suture, and lambdoid suture, it is thought that it will be helpful for clinical use if you shoot it 8cm down from the back of the head and tilt it 30° toward the head.

Two Cases of Avascular Necrosis of the Femur Head after Whole Pelvic Radiation Therapy for the Treatment of Cervical Cancer (자궁경부암의 전골반방사선치료 후 발생한 대퇴골두 무혈성괴사 2예)

  • Yu, Jeong-Il;Huh, Seung-Jae;Park, Won;Oh, Dong-Ryul;Lee, Jung-Ae
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.126-130
    • /
    • 2008
  • Avascular necrosis(AVN) is a disease characterized by the temporary or permanent loss of the blood supply to the bones, resulting from many possible causes, including radiation therapy. The femoral head is known to be the most common site of AVN. The authors encountered two cases of AVN of the femoral head among 557 patients with cervical cancer treated with whole pelvic radiation therapy at the Samsung Medical Center. AVN of the femoral head was presented with a sclerotic density change in a plain roentgenography and a decreased signal intensity lesion on the T1 and T2 weighted phases of a magnetic resonance image(MRI). Although it is a very rare complication after whole pelvic radiation therapy, AVN of the femoral head should be considered when characteristic imaging findings appear on follow-up examinations.

An Experimental Study on the Measurement of Flow Field in a Direct Diesel Engine Using a Single Cylinder Visualization Engine (가시화 엔진을 이용한 직분식 디젤엔진내의 유동장 측정에 관한 연구)

  • Han, Yong-Taek;Hwang, Kyu-Min;Lee, Ki-Hyung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.1
    • /
    • pp.129-137
    • /
    • 2006
  • This paper studies the effects of the swirl for the variation of intake port configuration that is key parameters in the flow field of direct injection diesel engines. In-cylinder flow characteristics is known to have significant effects on air-fuel mixing, combustion, and emissions. To investigate the effects of the swirl flow, various rpm(250, 500, 750) and two different intake port were used. And to evaluate the swirl motion in the flow field visualization engine, steady state flow test was conducted. Helical port intake port and SCV(Swirl Control Valve) were selected as the design parameters to increase the swirl flow and parametric study was performed. In the case of non-SCV, intake flow rate and non-dimensional swirl ratio were higher than those of SCV for the swirl head type. So, we could strengthen the swirl in the flow field with the swirl head type and don't using SCV. From the results of steady state flow test, non-swirl head type has the most good advantage for intake flow rate, and also the flow rate could be increased by using the SCV slightly. The effects of the type of engine head on intake air flow capability are dominant with respect to the existence of the SCV. We could measure the qualitative grade of swirl by capturing the scattering signal of microballoon from ICCD camera in the visualization diesel engine.

3D Head Modeling using Depth Sensor

  • Song, Eungyeol;Choi, Jaesung;Jeon, Taejae;Lee, Sangyoun
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.1
    • /
    • pp.13-16
    • /
    • 2015
  • Purpose We conducted a study on the reconstruction of the head's shape in 3D using the ToF depth sensor. A time-of-flight camera (ToF camera) is a range imaging camera system that resolves distance based on the known speed of light, measuring the time-of-flight of a light signal between the camera and the subject for each point of the image. The above method is the safest way of measuring the head shape of plagiocephaly patients in 3D. The texture, appearance and size of the head were reconstructed from the measured data and we used the SDF method for a precise reconstruction. Materials and Methods To generate a precise model, mesh was generated by using Marching cube and SDF. Results The ground truth was determined by measuring 10 people of experiment participants for 3 times repetitively and the created 3D model of the same part from this experiment was measured as well. Measurement of actual head circumference and the reconstructed model were made according to the layer 3 standard and measurement errors were also calculated. As a result, we were able to gain exact results with an average error of 0.9 cm, standard deviation of 0.9, min: 0.2 and max: 1.4. Conclusion The suggested method was able to complete the 3D model by minimizing errors. This model is very effective in terms of quantitative and objective evaluation. However, measurement range somewhat lacks 3D information for the manufacture of protective helmets, as measurements were made according to the layer 3 standard. As a result, measurement range will need to be widened to facilitate production of more precise and perfectively protective helmets by conducting scans on all head circumferences in the future.

The Realization of Panoramic Infrared Image Enhancement and Warning System for Small Target Detection (소형 표적 탐지를 위한 파노라믹 적외선 영상 향상 장치 및 경보시스템 구현)

  • Kim Ki Hong;Kim Ju Young;Jung Tae Yeon;Jeon Byung Gyoon;Lee Eui Hyuk;Kim Duk Gyoo
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.1
    • /
    • pp.46-55
    • /
    • 2005
  • In this paper, we realize the panoramic infrared warning system to detect the small threaten object and propose the infrared image enhancement method to improve the warning ability of this system. This system composes of the sense head unit, the signal processing unit, and so on. In the proposed system, the sense head unit acquires the panoramic IR image with 360 degree field of view(FOV) by rotating the thermal sensor. The signal processing unit divides panoramic image into four sub-images with 90 degree FOV and computes the adaptive plateau value by using statistical characteristics of each subimage. Then the histogram equalization is performed for each subimage by using the adaptive plateau value. We realize the signal Processing unit by using the DSP and FPGA to perform the proposed method in real time. Experimental results show that the proposed method has better discrimination and lower false alarm rate than the conventional methods in this warning system.

  • PDF

UWB impulse generator using gated ring oscillator (게이티드 링 발진기를 이용한 UWB 임펄스 생성기)

  • Jang, Junyoung;Kim, Taewook
    • Journal of IKEEE
    • /
    • v.25 no.4
    • /
    • pp.721-727
    • /
    • 2021
  • This paper proposes a UWB (Ultar-wideband) impulse generator using the gated ring oscillator. The oscillator and PLL circuits which generate a several GHz LO signal for the conventional architecture are replaced with the gated ring oscillator. Therefore, the system complexity is decreased. The proposed architecture controls the duty of enable signal, which is used for the head switch of ring oscillator. The control of the duty enables to tun off the oscillator during the guard interval and stop wasting the power consumption. The pulse shaping method using the counter makes the small side lobe and preserves the bandwidth regardless of the change on the center frequency. Designed UWB impulse generator could change the center frequency from 6.0 GHz to 8.8 GHz with a digital bit control, while it preserves the bandwidth as about 1.5 GHz.

Extraction or gaze point on display based on EOG for general paralysis patient (전신마비 환자를 위한 EOG 기반 디스플레이 상의 응시 좌표 산출)

  • Lee, D.H.;Yu, J.H.;Kim, D.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.5 no.1
    • /
    • pp.87-93
    • /
    • 2011
  • This paper proposes a method for extraction of the gaze point on display using EOG(Electrooculography) signal. Based on the linear property of EOG signal, the proposed method corrects scaling difference, rotation difference and origin difference between coordinate of using EOG signal and coordinate on display, without adjustment using the head movement. The performance of the proposed method was evaluated by measuring the difference between extracted gaze point and displayed circle point on the monitor with 1680*1050 resolution. Experimental results show that the average distance errors at the gaze points are 3%(56pixel) on x-axis, 4%(47pixel) on y-axis, respectively. This method can be used to human computer interface of pointing device for general paralysis patients or HCI for VR game application.

The Transmit System for Connection System of Super High Speed Optical Fiber Subscriber (초고속 광 가입자 접속장치용 송신장치 설계)

  • Song, Hong-Jong
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.10 no.1
    • /
    • pp.14-26
    • /
    • 2011
  • In this paper, we've studied Optical Fiber Subscribe Transmit system. After receiving the ATM cell passing through the FIFO of the Asynchronous Transfer Method from the ATM Layer images to the VC4 signal payload passing through scrambling of the cell payload, HEC computation of the cell and inserting the Idle/Unassigned cell. At this time formed VC4 signal passing through the generating and inserting POH overhead at the same time indicating the start point of the cell by the H4 byte on the VC4 POH. This ATM cell transmits 155Mbps speed changing the optical signal after outputting the frame format at the STM-1 signal generation block through the AUG bus after generating J1 of the VC4 start point at the AU4 pointer generation block.

  • PDF

The Noise Removal Methode of Partial Discharge Signal (부분방전 신호 검출 시 노이즈 제거방법)

  • Choi, Mun-Gyu;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.8
    • /
    • pp.1436-1441
    • /
    • 2016
  • Currently, partial discharge diagnosis in the field of prevention applied technology and diagnostic equipment is a possible strong limit to remove the noise generated by external or internal I still have one unreliable diagnosis. This technology is the noise removal from signal the time lag analysis algorithms technique is applied by a fundamental. Increasing the reliability in terms of technology spectrum frequence of analysis method for by applying the acquisition through the position of the frequency content and sources of traffic lights partial discharge of the acquisition of signal analysis to judge whether a way diagnosis the environment of the scene, and conditions. Partial discharge signal and make the discharge while building blocks were found through the Analysis. Spectrum frequence of Analysis and wide discharge part, to be more precise, in line with the various functions, including the analysis technique band. Diagnosis and comes up with advanced technology that can detect the presence of a position. This method is portable single device developed for maintenance and mobility and ease and convenience of getting caught by discharge of the pattern analysis and position detection method suitable for a new diagnosis will suggest.

Crash Risks and Crossing Behavior of older pedestrians in Mid-block Signalized Crosswalks (단일로 횡단보도에서의 고령보행자 횡단특성과 사고에 관한 연구)

  • Seo, Geumyeol;Choi, Jaisung;Jeong, Seungwon;Yeon, Junhyoung;Kim, Jeongmin
    • International Journal of Highway Engineering
    • /
    • v.19 no.4
    • /
    • pp.69-78
    • /
    • 2017
  • PURPOSES : In this study, we analyzed the road crossing behavior of older pedestrians on a mid-block signalized crosswalk, and compared it to that of younger pedestrians. In addition, we analyzed the correlation between accidents involving older pedestrians while crossing roads and their behavioral characteristics. Finally, we confirmed the reasons for an increase in accidents involving older pedestrians. METHODS : First, 30 areas with the highest incidence of accidents involving older pedestrians while crossing roads were selected as target areas for analysis. Next, we measured the start-up delay (the time elapsed from the moment the signal turns green to the moment the pedestrian starts walking) and head movement (the number of head turns during crossing a road) of 900 (450 older and 450 younger) pedestrians. The next step was to conduct a survey and confirm the differences in judgment between older and younger pedestrians about approaching vehicles. Finally, we analyzed the correlation between the survey results and traffic accidents. RESULTS : The average start-up delay and head movement of the older pedestrians was 1.58 seconds and 3.15 times, respectively. A definite correlation was obtained between head movement and the frequency of pedestrian traffic accidents. The results of our survey indicate that 17.3% of the older pedestrians and 7.8% of the younger pedestrians have a high crash risk. CONCLUSIONS : Behavioral characteristics of older pedestrians were closely correlated with accidents involving older pedestrians while crossing roads in mid-block signalized crosswalks. Our study indicates that in order to reduce the number of accidents involving older pedestrians, it is necessary to develop an improvement plan including measures such as installation of safety facilities taking the behavioral characteristics of older pedestrians into consideration and their safety education.