Abstract
This paper proposes a method for extraction of the gaze point on display using EOG(Electrooculography) signal. Based on the linear property of EOG signal, the proposed method corrects scaling difference, rotation difference and origin difference between coordinate of using EOG signal and coordinate on display, without adjustment using the head movement. The performance of the proposed method was evaluated by measuring the difference between extracted gaze point and displayed circle point on the monitor with 1680*1050 resolution. Experimental results show that the average distance errors at the gaze points are 3%(56pixel) on x-axis, 4%(47pixel) on y-axis, respectively. This method can be used to human computer interface of pointing device for general paralysis patients or HCI for VR game application.
본 논문에서는 EOG(Electrooculography) 신호를 이용하여 디스플레이상 응시하는 좌표를 산출 하는 방법을 제안하였다. 선형적인 특성을 가지는 EOG 신호를 기반으로 하여, 디스플레이와 EOG 신호의 2차원 좌표계 사이에 존재하는 회전, 스케일링, 원점의 차이를 머리의 움직임 대신에 보정 작업으로 일치시켰다. 1680*1050 해상도를 가지는 모니터에서 출력한 원의 좌표와 이를 응시 할 때 발생되는 EOG 신호에 보정 방법을 적용하여 산출된 좌표와의 비교로 성능을 평가하였다. 실험 결과에서 x, y좌표는 평균적으로 각각 56픽셀(3%), 47픽셀(4%)의 오차를 보여주고 있다. 이 연구는 전신 마비 환자를 위한 포인팅 장치나 가상현실 게임과 같은 애플리케이션을 위한 HCI(Human Computer Interface)로 활용이 가능하다.