• Title/Summary/Keyword: shielding method

Search Result 480, Processing Time 0.023 seconds

Evaluating the Reduction of Spatial Scattering based on Lead-free Radiation Shielding Sheet using MCNPX Simulation (MCNPX 시뮬레이션을 이용한 무납 방사선 차폐 시트 기반의 공간산란 저감화 평가)

  • Yang, Seung u;Park, Geum-byeol;Heo, Ye Ji;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.367-373
    • /
    • 2020
  • Most of the spatial scattered dose caused by the scattered rays generated by the collision between the object and X-rays is relatively easily absorbed by the human body as electromagnetic waves in the low energy region, thereby increasing the degree of radiation exposure. Such spatial scattering dose is also used as an indicator of the degree of radiation exposure of radiation workers and patients, and there is a need for a method to reduce exposure by reducing the spatial scattered dose that occurs indirectly. Therefore, in this study, a lead-free radiation shielding sheet was proposed as a way to reduce the spatial scattering dose, and a Monte Carlo (MC) simulation was performed based on a chest X-ray examination. The absorbed dose was calculated and the measured value and the shielding rate were compared and evaluated.

Organ Dose Assessment of Nuclear Medicine Practitioners Using L-Block Shielding Device for Handling Diagnostic Radioisotopes (진단용 방사성동위원소 취급 시 L-block 차폐기구 사용에 따른 핵의학 종사자의 장기 선량평가)

  • Kang, Se-Sik;Cho, Yong-In;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.49-55
    • /
    • 2017
  • In the case of nuclear medicine practitioners in medical institutions, a wide range of exposure dose to individual workers can be found, depending on the type of source, the amount of radioactivity, and the use of shielding devices in handling radioactive isotopes. In this regard, this study evaluated the organ dose on practitioners as well as the dose reduction effect of the L-block shielding device in handling the diagnostic radiation source through the simulation based on the Monte Carlo method. As a result, the distribution of organ dose was found to be higher as the position of the radiation source was closer to the handling position of a practitioner, and the effective dose distribution was different according to the ICRP tissue weight. Furthermore, the dose reduction effect according to the L-block thickness tended to decrease, which showed the exponential distribution, as the shielding thickness increased. The dose reduction effect according to each radiation source showed a low shielding effect in proportion to the emitted gamma ray energy level.

A study on Manufacture of EMI Composite Powder by the Electroless Ni Plating Method (무전해 니켈도금방법을 이용한 EMI 복합분말제조에 관한 연구)

  • Joung, I.;Yoon, S.R.;Han, S.N.;Na, J.H.;Kim, C.W.
    • Korean Journal of Materials Research
    • /
    • v.8 no.5
    • /
    • pp.444-449
    • /
    • 1998
  • There are various shielding materials that have been considered; the use of a metallic plate or the layering of a conductive material on a plastic surface and the insertion of filler in plastics. All of these methods have shown their merits and weakness. Therefore, many studies have concentrated on developing materials that effectively cut down EMI without increase in weights of housing materials. In these respects, this study has focused on investigations of the shielding effect of materials that have electroless nickel plating on the lamella structured micro particles surface with low specific gravity. When a film of electroless nickel were plated on a micro particle surfaces and then mixed with paint, the electromagnetic shielding effects were measured as 63dB. Although these effects were less than that 90dB of the copper plate, trials in a series of 6 times increased the shielding effect by IOdB and is applicable to wide range of EMI shielding.

  • PDF

The radiation shielding proficiency and hyperspectral-based spatial distribution of lateritic terrain mapping in Irikkur block, Kannur, Kerala

  • S. Arivazhagan;K.A. Naseer;K.A. Mahmoud;N.K. Libeesh;K.V. Arun Kumar;K.ChV. Naga Kumar;M.I. Sayyed;Mohammed S. Alqahtani;E. El Shiekh;Mayeen Uddin Khandaker
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3268-3276
    • /
    • 2023
  • The practice of identifying the potential zones for mineral exploration in a speedy and low-cost method includes the use of satellite imagery analysis as a part of remote sensing techniques. It is challenging to explore the iron mineralization of a region through conventional methods which are a time-consuming process. The current study utilizes the Hyperion satellite imagery for mapping the iron mineralization and associated geological features in the Irikkur region, Kannur, Kerala. Along with the remote sensing results, the field study and laboratory-based analysis were conducted to retrieve the ground truth point and geochemical proportion to verify the iron ore mineralization. The MC simulation showed for shielding properties indicate an increase in the linear attenuation coefficient with raising the Fe2O3+SiO2 concentrations in the investigated rocks where it is varied at 0.662 MeV in the range 0.190 cm-1 - 0.222 cm-1 with rising the Fe2O3+SiO2 content from 57.86 wt% to 71.15 wt%. The analysis also revealed that when the γ-ray energy increased from 0.221 MeV to 2.506 MeV, sample 1 had the largest linear attenuation coefficient, ranging from 9.33 cm1 to 0.12 cm-1. Charnockite rocks were found to have exceptional shielding qualities, making them an excellent natural choice for radiation shielding applications.

The influence of Ni ion addition on the microstructure and gamma ray shielding ability of ferromagnetic CuFe2O4 ceramic material

  • Mohammad W. Marashdeh;Fawzy H. Sallam;Ahmed M. Abd El-Aziz;Mohamed I. Elkhatib;Sitah f. Alanazi;Mamduh J. Aljaafreh;Mohannad Al-Hmoud;K.A. Mahmoud
    • Nuclear Engineering and Technology
    • /
    • v.56 no.7
    • /
    • pp.2740-2747
    • /
    • 2024
  • The sintering process acquired ferromagnetic copper ferrite ceramic material with a small concentration of Ni ion at 1100 ℃ for 1 h. Previously, copper ferrite with Ni proportions powder was acquired by the wet chemical process according to the relation CuFe2-xNixO4 where x takes values 0.0, 0.015, 0.03, 0.04, and 0.05. The role of Ni ion in the copper ferrite structure was investigated by X-ray analysis, Scanning electron microscope, EDX analysis, and density measurements. The gamma-ray shielding properties for the fabricated CuFeNiO ceramics samples were evaluated using the Monte Carlo simulation method. The obtained results show an enhancement in the linear attenuation coefficient for the fabricated ceramics with increasing the insertions of Ni ions within the fabricated samples, where increasing the Ni ions concentration between 0 and 1.19 wt% increases the linear attenuation by between 1.581 and 1.771 cm-1 (at 0.103 MeV), 0.304-0.338 cm-1 (at 0.662 MeV), and 0.160-0.178 cm-1 (at 2.506 MeV), respectively. Simultaneously, the radiation protection efficiency for a 1 cm thickness of the fabricated samples increased between 14.8 and 16.3% with increasing the Ni ions between 0 and 1.19 wt%. Although the Ni doping concentration does not exceed 1.5 wt% of the total composition of the fabricated ceramics, the shielding capacity of the fabricated ceramics was enhanced by more than 11%, along the studied energy interval. Therefore, the fabricated samples can be used in gamma-ray shielding applications.

A new Tone's method in APOLLO3® and its application to fast and thermal reactor calculations

  • Mao, Li;Zmijarevic, Igor
    • Nuclear Engineering and Technology
    • /
    • v.49 no.6
    • /
    • pp.1269-1286
    • /
    • 2017
  • This paper presents a newly developed resonance self-shielding method based on Tone's method in $APOLLO3^{(R)}$ for fast and thermal reactor calculations. The new method is based on simplified models, the narrow resonance approximation for the slowing down source and Tone's approximation for group collision probability matrix. It utilizes mathematical probability tables as quadrature formulas in calculating effective cross-sections. Numerical results for the ZPPR drawer calculations in 1,968 groups show that, in the case of the double-column fuel drawer, Tone's method gives equivalent precision to the subgroup method while markedly reducing the total number of collision probability matrix calculations and hence the central processing unit time. In the case of a single-column fuel drawer with the presence of a uranium metal material, Tone's method obtains less precise results than those of the subgroup method due to less precise heterogeneous-homogeneous equivalence. The same options are also applied to PWR UOX, MOX, and Gd cells using the SHEM 361-group library, with the objective of analyzing whether this energy mesh might be suitable for the application of this methodology to thermal systems. The numerical results show that comparable precision is reached with both Tone's and the subgroup methods, with the satisfactory representation of intrapellet spatial effects.

Magnetic Shielding with Thin Magnetic Materials near Power Cables (박판 자성 재료를 이용한 전력 케이블 인근의 자기장 차폐)

  • Kim, Sang-Beom;Soh, Joon-Young;Shin, Koo-Yong;Jeong, Jin-Hye;Myung, Sung-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.7
    • /
    • pp.639-647
    • /
    • 2009
  • In this work, wrapping conductors with thin magnetic materials is proposed as a magnetic shielding method. The 0.1 mm thick metal sheets of mu-metal, grain-oriented electrical steel, and non-oriented electrical steel were produced from commercial alloy sheets through cold rolling and followed high temperature annealing. In case of 3-phase electric currents, mu-metal was the best in shielding performance at a B-field magnitude of about 100 ${\mu}T$, whereas silicon steels were better than mu-metal at a B-magnitude over 500 ${\mu}T$. In addition, wrapping with silicon steel(inner) together with mu-metal(outer) resulted in a shielding factor less than 0.1 even at 500 ${\mu}T$. These results are due to changes in hierarchy of magnetic permeabilities of the materials with increasing magnetic field strength. In case of single-phase electric current, B-magnitude outside the magnetic shell was rather increased compared to the unshielded case. This result is explained by vector composition of B-fields near magnetic shielding materials.

Evaluation of Scattered Rays of Jelly Type Shielding Body by L-spine AP using X-ray (L-Spine X-선 촬영에서의 Jelly type 차폐체의 산란선 차폐평가)

  • Jang, Hui-Min;Kim, Do-Gwon;Kim, Hyeong-Bin;Yoon, Joon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.907-913
    • /
    • 2020
  • There have been continuous controversies on medical X-ray protection and numerous researchers have been trying to prevent unnecessary exposure to radiation. As X-ray passes through the patient and obtains an image, it creates scattered ray due to interactions such as photoelectric effect and Compton scattering with the subject. As a result, both medical radiation staff and patient are exposed to unnecessary radiation on areas other than the target area. In response, this study will be assuming a body of a female, radiating X-ray on the phantom under the conditions of lumbar spine AP test, and measuring scattered ray around breasts and thyroid glands. Then, The experiment results were as follows. After application of non-shielding material, the average of scattered ray was 0.88 mR in thyroid measurement, 3.34 mR, Lt Axillary 3.54 mR, and Rt Axillary 3.03 mR in mamonary measurement but, After application of shielding material, the average of scattered ray was 0.16 mR in thyroid measurement, 0.60 mR, Lt Axillary 0.64 mR, and Rt Axillary 0.54 mR in mamonary measurement showing average scattered ray protection effect of about 82%. This study suggested the manufacturing method of a Jelly-type shielding material, identified the possibilities of researches on mixing various substances with radiology field, and verified the usability of the Jelly-type shielding material as a substitute for existing protection tools.

Selective Beam Shielding Method of Gamma-Knife Unit Using Various Plugging Patterns (다양한 Plugging 형태를 이용한 감마나이프의 선택적 빔 차폐 방법)

  • Jang Geon Ho;Lim Young Jin;Shin Dong Oh;Choi Doo Ho;Hong Seong Eon;Leem Won
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.439-448
    • /
    • 1993
  • The B-type gamma knife unit was installed at Kyung-Hee University Hospital in March 1992. The selective beam plugging method can be used to reduce the low percentage isodose profiles of normal sensitive organ and to modify the isodose curves of treatment volume for better shaping of the target volume. For representing the changes of the low percentage isodose profiles, the variations of dose distribution for several cases were discussed in this paper. The film dosimetry was peformed for the evaluation of calculated isodose profiles predicted by KULA dose planning system. The results were verified by RFA-3 automatic densitometry. The clinical application of selective beam shielding method was peformed in 17 patients in 100 patients who have undergone gamma knife radiosurgery for a year. The calculated and the measured isodose profiles for the high percentage regions were well consistent with each other. When the target of pituitary tumor is macro-size, the selective beam shielding method is the most applicable method. When the target size, however, is small, the correct selection of the proper helmet size is very important. All patients were exposed almost about 3~12 Gy for brain stem, and 3~11.2 Gy for optic apparatus. It is recommended that the same or other plugging patterns with multiple isocenters should be used for protection of the radiosensitive normal structures with precise treatment of CNS lesions.

  • PDF

Analysis of EMI Shielding Performance of Two Finite Image Planes Configuration (유한 이층 영상평면 구조에 의한 EMI 차폐성능 분석)

  • Kim, Jin-Suk;Yun, Jae-Hoon;Lee, Ae-Kyung;Kim, Nam
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.5A
    • /
    • pp.682-687
    • /
    • 2000
  • EMI problem is very important in a printed circuit board design. This paper deals with image plane as one of the most effective method to reduce EMI in PCB. The shielding performance of one and two layers of image planes of finite width and length is analyzed by the method of moments based on the triangular surface patch model. The current distributions were modeled as two simple line sources. It is demonstrated that proper triangulation should be made so as to take two basis functions in the boundary triangles of the surface.

  • PDF