• Title/Summary/Keyword: sewage treatment facility

Search Result 111, Processing Time 0.021 seconds

A Study on Management of Seafood Wastewater Treatment Facility using Submerged MBR (침지식 MBR을 이용한 수산물 폐수처리장 운영에 관한 연구)

  • Choi, Yong-Bum;Lee, Hae-Seung;Han, Dong-Joon;Kwon, Jae-Hyouk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7227-7236
    • /
    • 2015
  • The survey revealed that, due to the discharge characteristics of seafood wastewater, irregular inflow loads were caused, making it difficult to treat the wastewater safely. It is crucial for the operation of pressure and floating tanks for the treatment of high-concentration organic wastewater such as seafood wastewater. The survey of operation factors for the pressure and floating tanks revealed this: A/S ratio 0.05 (design criteria 0.01), the pressurized air pressure 8bar(design criteria 6bar), the pressure tank pressure 6bar (design criteria 4.5bar), and HRT 60sec(design criteria: 10sec). Also, the recirculation rate was changed to over 40%(design criteria: 30%), and the surface load rate was changed to under $13.7m^3/m^2{\cdot}hr$(design criteria: under $17.7m^3/m^2{\cdot}hr$); thus, compared to the initial design criteria, the operation factors were changed according to inflow characteristics, thus enhancing the pressure and floating tank performance. The survey of inflow load revealed BOD 140.7%, $COD_{Mn}$ 120.32%, and SS 106.3%, compared to the inflow design criteria, as well as T-N 135.5% and T-P173.3%, higher than the design criteria. The survey of the treatment facility annual operation cost revealed high portions in sludge treatment cost(27.7%) and chemicals costs(26.0%), and the sludge treatment cost will likely further increase due to the ban on ocean dumping. The unit cost for the treatment of seafood wastewater was found to be KRW 3,858 per ton, more than 27 times higher than the sewage treatment cost(KRW 142.6/ton), presumably because the seafood wastewater contains high-concentration organic substances and nutritive salts.

Lifecycle cost assessment of best management practices for diffuse pollution control in Han River Basin (한강수계 비점오염원 저감시설의 생애주기비용 평가)

  • Lee, Soyoung;Maniquiz-Redillas, Marla C.;Lee, Jeong Yong;Mun, Hyunsaing;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.18 no.4
    • /
    • pp.448-455
    • /
    • 2016
  • Diffuse pollution management in Korea initiated by the Ministry of Environment (MOE) resulted to the construction of pilot facilities termed Best Management Practices (BMPs). Twelve BMPs installed for the diffuse pollution management in the Kyung-An Stream were monitored since 2006. Data on the mass loading, removal efficiency, maintenance activities, etc. were gathered and utilized to conduct the evaluation of long-term performance of BMPs. The financial data such as actual construction, design and maintenance cost were also collected to evaluate the lifecycle cost (LCC) of BMPs. In this study, most of the maintenance activity was focused in the aesthetic maintenance that resulted to the annual maintenance cost of the four BMP types was closely similar ranging from 8,483 $/yr for retention pond to 8,888 $/yr infiltration system. The highest LCC were observed in constructed wetland ($418,324) while vegetated system had the lowest LCC ($210,418). LCC of BMPs was not so high as compared with the conventional treatment facility and sewage treatment plant. On the other hand, the relationship of removal efficiency on unit cost for TSS and TN was significant. This study will be used to design the cost effective BMP for diffuse pollution management and become models for LCC analysis.

Removal Efficiency of the Deodorization Equipment and Characteristics of Malodor during the Process in Co-treatment of Sewage and Food Waste of Su-young Wastewater Treatment Plant in Busan (부산수영하수처리장 하수와 음식물쓰레기 병합처리 시 공정별 악취특성 및 후처리시설 효율평가)

  • Lee, Hyung-Don;Kang, Dae-Jong;Lee, Min-Ho;Kang, Dong-Hyo;Oh, Kwang-Joong
    • Clean Technology
    • /
    • v.18 no.4
    • /
    • pp.379-389
    • /
    • 2012
  • Environmental issues are being paid more attention due to income growth, urban overcrowding, and population growth in Korea. Among the various environmental problems, odor damage is the one of the serious factors. To take example for food waste combination treatment in Su-young wastewater treatment plant in Busan, many complaints occurred because this plant locate around residential areas. The purpose of this work is not only to analyze odorous elements and their contributions but also to evaluate odor quotient (OQ), sum of odor quotient (SOQ), and treatment efficiency of bio-filter. The results of dilution sensory test of complex odor, grinder, leachate, hopper indicated higher order complex odors happen in July and August. The main odorous elements consisted of hydrogen sulfide, ammonia, methly mercaptan and acetaldehyde, which were analyzed by instrumental detection method, and methyl mercaptan was exceeded over 3,571 times of threshold. In addition, result of contribution of odor was methyl mercaptan (49.95 to 59.08%), hydrogen sulfide (20.43 to 29.27%), trimethylamine (8.82 to 13.42%) and acetaldehyde (9.17 to 11.35%). Other facilities were compared with the contribution of the odor using OQ and SOQ during the process. Sulfur compounds, acetaldehyde, and trimethylamine are high contribution of odor using OQ as well as odor intensity of grinding process is highest. As a result, sulfur compounds (e.g., methyl mercaptan and hydrogen sulfide) are highest for OQ and SOQ of grinding process is highest as 7,067. The removal efficiency of deodorization equipment was more than 90.00% in ammonia and amines, but the average efficiency of sulfur compounds was 53.51%. Thus, this facility is more higher contribution of acetaldehyde and trimethylamine than other treatment facilities. And food waste treatment in environmental area needs to consider appropriate capacity and refers to other bio-filter operating conditions.

Waste Activated Sludge Digestion with Thermophilic Attached Films (친열성(親熱性) 생물막공법(生物膜工法)을 이용(利用)한 폐활성(廢活性) 슬러지의 혐기성(嫌氣性) 소화(消化))

  • Han, Ung Jun;Kabribk, R.M.;Jewell, W.J.
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.5 no.4
    • /
    • pp.31-44
    • /
    • 1985
  • The application of anaerobic attached microbial films in the expanded bed process has recently been examined at high temperatures ($55^{\circ}C$) and with particulate matter. Extrapolation of the kinetics suggested that waste activated sludge (WAS) could be efficiently digested at hydraulic retention times as short as six hours in the expanded bed process. This would represent a 99 percent digester reactor volume reduction and would introduce interesting solids management alternatives if such a high rate process were developed. This paper presents a summary of a 1.5 year study of the feasibility of such a process. Three continuously fed $55^{\circ}C$ laboratory reactor systems were used to define the kinetics and the site of reactions-control completely mixed reactors were compared to the expanded beds (AAFEB) with and without a hydrolysis unit preceding the attached film unit. Well defined laboratory-generated WAS was compared to actual WAS from a domestic sewage treatment facility. Sixty percent of the biodegradable organics were converted in an AAFEB at a 15-hour hydraulic retention time without hydrolysis, whereas greater than 95 perccent of the biodegradable organics were stabilized in a two-stage system consisting of a 3-day HRT hydrolysis reactor followed by a 15-hour HRT AAFEB. The limitations of this high rate process and its potential application are discussed.

  • PDF

Developing Evaluation Index and Item for Water Environment Improvement of Gyeongin ARA Waterway (경인 아라뱃길의 물환경 개선을 위한 오염원인 평가항목 및 지표 개발)

  • Lee, Kyung-Su;Kim, Tae-Hyeong
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.8
    • /
    • pp.469-482
    • /
    • 2018
  • This research has developed the criteria and index for systematically and objectively assessing the quality of river water by fixing the various factors that affect Gyeongin ARA waterway's water quality through analysis with the Delphi Technique and analytic hierarchy program (AHP) Method. Based on the results, the highest criteria are, in order of importance, physical and environmental factors 28%, administrative factors 26%, natural fixed factors 26% and finally, cultural and social factors 20%. The three dimensions of the criteria show that for the internal physical and environmental factors, the most important are the loss of self-purification capacity, and the external factors are Gulpocheon and the sludge deposit due to Gyulhweon-weir the bridge. The facility factor in management was affected by the coagulation and waste water disposal facilities. The problem for the policy and institutional factors was seen in the regulatory area. The aquatic ecology/ point pollution source for the natural fixed factors show that it is due to the polluted water of Gulpo-cheon and the living environment/ non-point pollution source is shown through the inflow water from other rivers. Cultural and social factors show that the economical causes were due to the cargo and passenger flight operations and the external factors of having a lack of sewage treatment equipment have an importance effect. In order to estimate the order of priority through logical evidence and objectivity, future research must be continued on the evaluation indexes to measure the specific methodology and technique needed to improve the Gyeongin ARA Waterway.

Application of QUAL-2E Model for Water Quality Management in the Keum River -Waste loads Allocation Analysis by Considering Autochthonous BOD- (금강수계의 수질관리를 위한 QUAL-2E 모델의 적용(II) -자생BOD를 고려한 허용오염부하량 산정-)

  • 김종구;이지연
    • Journal of Environmental Science International
    • /
    • v.10 no.1
    • /
    • pp.21-25
    • /
    • 2001
  • The Keum river has been utilized for drinking water supply of several city including Kunsan city and is deepening pollution state due to numerous municipal and industrial discharges. The concentration BOD in river is affected by the organic loading from a tributary and the algae biomass that largely happen to under eutrophication state. In the eutrophic water mass such as the Keum river, the autochthonous BOD was very important part for making a decision of water quality management, because it was accounted for majority of the total BOD. The predict of water quality has important meaning for management of water quality pollution of the Keum river. The purpose of this study will manage and predict water quality of the Keum river using QUAL-2E model considering the autochthonous BOD. The estimation of autochthonous BOD represented that the relationship between BOD and chlorophyll a. The regression equation was shown to be autochthonous BOD=$\beta$(sub)5$\times$chlorophyll a. The results of this study may be summarized as followed; The QUAL-2E model was calibrated with the data surveyed in the field of the study area in June, 1998. The calculated value by QUAL-2E model are in good agree to measured value within relative error of 7.80~20.33%. Especially, in the case of the considering autochthonous BOD, the calculated value of BOD were fairly good coincided with the observed values within relative error of 15%. But the case of not considering autochthonous BOD, relative error of BOD was shown to be 43.2%. In order to attain II grade of water quality standard in Puyo station which has a intake facility of water supply, we reduced to the pollutants loading of tributaries. In the case of removed 100% BOD of tributaries, the BOD of Puyo station was 4.07mg/$\ell$, belong to III grade of water quality standard. But in the case of removed 88% nutrient of tributaries, it was satisfied to II grade of water quality standard as below 3mg/$\ell$ of BOD. For estimation of autochthonous BOD in Keum river, we are performed simulating in accordance with reduction of nutrient load(50~100%) under conditions removal 90% organic load. Occupancy of autochthonous BOD according to nutrient loading reductions were varied from 25.97~79.51%. Occupancy of autochthonous BOD was shown to be a tendency to increasing in accordance with reduction of nutrient loading. Showing the above results, the nutrient that one of the growing factor of algae was important role in decision of BOD in the Keum river. For the water quality management of the Keum river, therefore, it is necessary to considering autochthonous BOD and to construction of advanced sewage treatment plant for nutrient removal.

  • PDF

A Study on Establishment of Technical Guideline of the Installation and Operation for the Biogas Utilization of Transportation and City Gas: Results of the Field Investigation (고품질화 바이오가스 이용 기술지침 마련을 위한 연구(I): 도시가스 및 수송용 - 현장조사 결과 중심으로)

  • Moon, HeeSung;Kwon, Junhwa;Park, Hoyeon;Jeon, Taewan;Shin, Sunkyung;Lee, Dongjin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.1
    • /
    • pp.77-85
    • /
    • 2019
  • Biogasification is a technology that uses organic wastes to reproduce as environmental fuels containing methane gas. Biogasification has attracted worldwide attention because it can produce renewable-energy and stable land treatment with prohibit from landfilling and ocean dumping of organic waste. Biomethane is produced by refining biogas. It is injected into natural gas pipeline or used transportation fuel such as cars and buses. 90 bio-gasification facilities are operating in 2016, and methane gas production is very low due to it is limited to organic wastes such as food waste, animal manure, and sewage sludge. There are seven domestic biomethane manufacturing facilities, and the use of high value-added such as transport fuels and city-gas through upgrading biogas should be expanded. On the other hand, the rapid biogasification of organic wastes in domestic resulted in frequent breakdowns of facilities and low efficiency problems. Therefore, the problem is improving as technical guidance, design and operational technical guidance is developed and field experience is accumulated. However, while improvements in biogas production are being made, there is a problem with low utilization. In this study, the problems of biomethane manufacturing facilities were identified in order to optimize the production and utilization of biogas from organic waste resources. Also, in order to present the design and operation guideline of the gas pretreatment and the upgrading process, we will investigate precision monitoring, energy balance and economic analysis and solutions for on-site problems by facility.

A study on ecological reprocessing and creation of biotope by reuse of treated waste water and nonpoint pollution source of stream (하수처리수와 하천 비점오염원을 이용한 생태적 재처리 효과와 생물 서식처 창출 방안 - 왕포천 생태적수질정화비오톱(Sustainable Structured wetland Biotop) 시스템 사례를 중심으로 -)

  • Byeon, ChanWoo;Lee, JongnChan
    • Journal of Wetlands Research
    • /
    • v.21 no.4
    • /
    • pp.374-383
    • /
    • 2019
  • The Wangpo stream located in the Buyeo-gun was a small stream with both low water quality and quantity due to the cultivated land and settlement area through the stream. In order to restore ecosystem, the Sustainable Structured wetland Biotop system was applied to treat 1,500 to 7,000 ㎥/d amount of effluent water pumped from the Buyeo sewage treatment plant facility as well as inflowed from nonpoint pollution source of Wangpo stream. As a result of continuous monitoring for 2 years from 2016 to 2018 after completing restorative construction, the average BOD5 as an index of organic pollution was 7.3 mg/L and the average effluent concentration became 2.1 mg/L, showing an improvement by 71.2%. The average inflow concentration of T-N was 7.953 mg/L and the average outflow concentration was 3.379 mg/L, showing 57.5% of improvement. The average inflow concentration of T-P was 0.177 mg/L and the average outflow concentration was 0.052 mg/L, showing about 70.7% improvement. The results of ecological monitoring after creating biotope by reuse of treated waste water and nonpoint pollution source of the Wangpo Stream are as follows. The plant taxa founded in water SSB(Sustainable Structured wetland Biotop) system of the Wangpo Stream was total 41 species in 21 families, showing a higher proportion of naturally introduced plant than that of artificially planted species. In case of other terrestrial animals, both amphibian and reptile group were confirmed as 3 species in 6 families, avian group was 25 species of 15 families, and mammal group observed 5 species in 5 families, respectively. All species have been created and enhanced through purified water inhabited in the SSB(Sustainable Structured wetland Biotop) system as a treatment wetland, eventually migrating to the Wangpo Stream.

Evaluation and Improvement Measures on the Status of the Installation and Operation of Facilities for Recycling Food Waste into Resources (음식물 자원화시설의 설치·운영에 대한 일반현황의 평가 및 개선 방안)

  • Ryu, Ji-Young;Kong, Kyu-Sik;Shin, Dae-Yewn;Phae, Chae-Gun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.3
    • /
    • pp.63-75
    • /
    • 2004
  • This research sought to determine the status of the installation and operation of domestic public resource-making facilities of resource-making facilities and come up with corresponding improvement measures. Currently compost is most numerous set-up out of facilties already established ever since, then the rest of them are feeds, anaerobic degradation, sewage combination, and combination of compost and feeds in order. As such, food waste is processed more into compost than into feeds, presumably because relevant facilities, which were originally designed for processing into feeds, were converted into composting facilities due to little demand for the processed feeds. The finding says that many related firms had yet to register their businesses in accordance with feeds and fertilizers management laws, and that food waste resources-making facilities used various basic facilities but few of them treated food waste in linkage with leaching water, bad odors, and energy. Some of current facilities were found to be 7 years old and thus outdated. Due to lack of skilled operational manpower, many facilities had less than 300 days of normal operation yearly, and some needed minor and serious repairs periodically. In overall facilities, 87% of the planned food waste was rolled in, thus requiring measures to treat the whole planned volume. For costs of resource-making facilities, some with a capacity of below 50 tons topped 100 million won, and facilities with a capacity of over 50 tons required less installation costs. Overall, installation costs ranged from 10 million to 20 million, and to 200 million won per ton, and this suggests a need to establish the installation cost calculation criteria, as well as to reshape the facility criteria. With operating costs varying greatly according to the size and treatment methods of facilities, the finding indicates a need to rationalize the operating costs, and to plan appropriate-size installation and operation of facilities to ensure economic operation.

  • PDF

Operating Status and Improvement Plans of Ten Wetlands Constructed in Dam Reservoirs in Korea (국내 10개 댐저수지 인공습지의 운영현황 및 개선방안)

  • Choi, Kwangsoon;Kim, Sea Won;Kim, Dong Sup;Lee, Yosang
    • Journal of Wetlands Research
    • /
    • v.16 no.3
    • /
    • pp.431-440
    • /
    • 2014
  • To propose the improvement and management plans to strengthen the pollutant removal efficiency of dam reservoir's constructed wetlands(CWs), the operation status and configuration of CWs (including water depth, operational flow, water flow distribution, residence time, and pollutant removal efficiency, aspect ratio, open water/vegetation ratio etc.) were analyzed in 10 major wetlands constructed in dam reservoirs. The pollutant concentrations in the inflows of the studied CWs were lower than those of American and European constructed wetlands. Especially, organic matter concentrations in all of inflows were below 3 mg/L(as BOD) due to advanced treatment of sewage disposal plant and an intake of low concentration water during dry and normal seasons. The average removal efficiency of total nitrogen(TN) and total phosphorus(TP) for 10 CWs ranged from 7.6~67.6%(mean 24.9%) and -4.9~74.5%(mean 23.7%), respectively, showing high in wetlands treating municipal wastewater. On the other hand, the removal efficiency of BOD was generally low or negative with ranging from -133.3 to 41.7%. From the analysis of the operation status and configuration of CWs, it is suggested that the low removal efficiency of dam reservoir's CWs were caused by both structural (inappropriate aspect ratio, excessive open water area) and operational (neglecting water-level management, lack of facilities and operation for first flush treatment, lake of monitoring during rainy events) problems. Therefore, to enable to play a role as a reduction facility of non-point source(NPS) pollutants, an appropriate design and operation manuals for dam reservoir's CW is urgently needed. In addition, the monitoring during rainy events, when NPS runoff occur, must be included in operation manual of CW, and then the data obtained from the monitoring is considered in estimation of the pollutant removal efficiency by dam reservoir's CW.