• 제목/요약/키워드: serial technology

Search Result 530, Processing Time 0.052 seconds

Implementation of High Speed Serial interface for testing LCD module by using the MDDI (MDDI방식 LCD모듈의 테스트하기 위한 고속직렬통신 인터페이스 구현)

  • Kim, Sang-Mok;Kang, Chang-Hun;Park, Jong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.212-214
    • /
    • 2005
  • The MDDI(Mobile Digital Display Interface) standard is an optimized high-speed serial interconnection technology developed by Qualcomm and supports the VESA(Video Electronics Standard Association). It increases reliability and reduces power consumption in clamshell phones by decreasing the number of wires to interconnect with the LCD display. In this paper, the MDDI host is designed using VHDL and implemented on FPGA. We demonstrates that the MDDI host is connected with S3CA460 LCD controller is designed by Samsung Electronics Co. and display a steal image to the LCD.

  • PDF

A Study on Z39.56 Standard and It's Applications (Z39.56 표준과 그 적용에 관한 연구)

  • Noh, Kyung-Ran
    • Journal of Information Management
    • /
    • v.33 no.4
    • /
    • pp.129-144
    • /
    • 2002
  • SICI(Serial Item and Contribution Identifier) is intended primarily for use by those involved in the use or management of serial titles and their contributions. And SICI is a standard that is developed for interoperability and electronic data exchange because of increasing need of the unique resource identifier. This paper introduces metadata standard ANSI/NISO Z39.56 that relates serials management. And it examines applications and implementations of Z39.56 toward serials management.

A 1.5 Gbps Transceiver Chipset in 0.13-μm CMOS for Serial Digital Interface

  • Lee, Kyungmin;Kim, Seung-Hoon;Park, Sung Min
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.4
    • /
    • pp.552-560
    • /
    • 2017
  • This paper presents a transceiver chipset realized in a $0.13-{\mu}m$ CMOS technology for serial digital interface of video data transmission, which compensates the electrical cable loss of 45 dB in maximum at 1.5 Gbps. For the purpose, the TX equips pre-emphasis in the main driver by utilizing a D-FF with clocks generated from a wide-range tuning PLL. In RX, two-stage continuous-time linear equalizers and a limiting amplifier are exploited as a front-end followed by a 1/8-rate CDR to retime the data with inherent 1:8 demultiplexing function. Measured results demonstrate data recovery from 270 Mbps to 1.5 Gbps. The TX consumes 104 mW from 1.2/3.3-V supplies and occupies the area of $1.485mm^2$, whereas the RX dissipate 133 mW from a 1.2-V supply and occupies the area of $1.44mm^2$.

A new insight into design of acoustic liner arrays arrangement in the presence of a grazing flow

  • Hadi Dastourani ;Iman Bahman-Jahromi
    • Advances in Computational Design
    • /
    • v.8 no.4
    • /
    • pp.273-293
    • /
    • 2023
  • This study evaluated the acoustic performance of two configurations of serial HR arrays and lined HR arrays in the presence of grazing flow using a 3D numerical simulation. The dual, triple, and quad HR arrays were compared to the conventional HR array. The simulation results showed that the number of resonant frequencies increased with the number of serial HR arrays. The CTL did not significantly change with the number of serial HR arrays. The acoustic performance of the two, three, and four-lined HR arrays was compared to the conventional HR array. The results showed that the resonant frequency and TLmax increased with the number of lined HR arrays. The CTL also increased with the number of lined HR arrays. The effect of the grazing flow Mach number (Ma) was investigated on the four-lined HR array configuration and compared to the conventional HR configuration. TLmax and CTL decreased for both configurations with increasing Ma. The four-lined HR array configuration had significantly better acoustic performance than the conventional HR configuration. The TLmax and CTL increased by more than 300% when the configuration was changed from the conventional HR to the four-lined HR array at Ma = 0.The increment percentage decreased with increasing Ma.

Issues in Building Large RSFQ Circuits (대형 RSFQ 회로의 구성)

  • Kang, J.H.
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.17-22
    • /
    • 2001
  • Practical implementation of the SFQ technology in most application requires more than single-chip-level circuit complexity. Multiple chips have to be integrated with a technology that is reliable at cryogenic temperatures and supports an inter-chip data transmission speed of tens of GHz. In this work, we have studied two basic issues in building large RSFQ circuits. The first is the reliable inter-chip SFQ pulse transfer technique using Multi-Chip-Module (MCM) technology. By noting that the energy contained in an SFQ pulse is less than an attojoule, it is not very surprising that the direct transmission of a single SFQ pulse through MCM solder bump connectors can be difficult and an innovative technique is needed. The second is the recycling of the bias currents. Since RSFQ circuits are dc current biased the large RSFQ circuits need serial biasing to reduce the total amount of current input to the circuit.

  • PDF

A study of the communication transfer mode of physical signal (EKG, PPG) (생체신호(EKG, PPG)의 통신전송 모드에 대한 연구)

  • Kim, Jeong-Lae;Kim, Gwan-Seok;Kim, Jae-Yoon;Kim, Han-Na;Jang, Eun-Yiu
    • The Journal of the Convergence on Culture Technology
    • /
    • v.3 no.2
    • /
    • pp.55-59
    • /
    • 2017
  • We are confirmed to the transfer degree of physical signal with the communication code on the wireless communication system. The physical transfer system was consisted of such as ECG, PPG and Bluetooth part that received signal. Communication method was take the international standard level of IEEE802.15.1 forms, the frequency transition was needed the bandwidth of communication for transfer signal with the band-communication method. The program was expressed to receive with wireless communication condition that was consisted of such as the serial chart, processing and app inventor. Their signal was identified to transfer certainly the corrected signal. Therefore, signal processing for coding by the real-time graphing and using processing by a standard capacity of serial-chart graphing that will be possible to progress the improvement effectiveness of wireless communication system.

Design of QPSK Demodulator Using CMOS BPSK Receiver and Reflection-Type Phase Shifter (CMOS 기반 BPSK 수신기와 반사형 위상 천이기를 이용한 QPSK 복조기 설계)

  • Moon, Seong-Mo;Park, Dong-Hoon;Yu, Jong-Won;Lee, Moon-Que
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.8
    • /
    • pp.770-776
    • /
    • 2009
  • We propose and demonstrate an I/Q demodulator using four-port BPSK demodulator base on additive mixing and reflection-type phase shifter using hybrid technique. Previously, the conventional I/Q demodulator base on multiplicative or additive mixing method divides I/Q signal path from mixer to parallel-to-serial converter. In this paper, we propose new I/Q demodulator without dividing I/Q baseband signal path. The proposed schematic requires half size in implementation and half power consumption in baseband path compared with the conventional receiver. Also, the proposed receiver eliminates parallel-to-serial converter after data decoding. The proposed circuit has been successfully demodulated a QPSK signal with the L-band carrier frequency and 20 Mbps data rate.

Analysis of Motor Performance and P300 during Serial Task Performance according to the Type of Cue (시열과제 수행 시 신호형태에 따른 운동수행력과 P300 분석)

  • Lee, Myoung-Hee;Kim, Myung-Chul;Park, Ju-Tae
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.8 no.2
    • /
    • pp.281-287
    • /
    • 2013
  • PURPOSE: The study was designed to investigate the effects of visual, auditory, and visuoauditory cues on simple Serial Task Performance in heaithy adults. METHODS: Sixty-three right-handed heaithy adults without history of neurological dysfunction were participated. A modified version of the Serial Reaction Time Task (SRTT) using five blocks of perceptual motor sequences was administered. The blocked paradigm consisted of the five blocks with randomly repeated 8 digit sequences with 5 repetition. Three types of sensory cue were employed: visual cue, auditory cue and visuoauditory cue. All subjects were assigned to press the matched botton as quickly and accurately as possible, when one of 8 stimulations was presented(one, two, three, four, five, six, seven, eight). The reaction time, accuracy, and P300 latency were measured during serial task performance. The mean reaction time(ms), accuracy(%), and P300 latency(ms) were compared between three types of cue using ANOVA. RESULTS: The reaction time to auditory cue was significantly longer than visual and visuoauditory cues(p<.001). And accuracy to auditory cue was significantly lower than visual and visuoauditory cues(p<.001). All P300 latency(at Fz, Cz, Pz) were significantly longer than to visual and visuoauditory cues(p<.05). CONCLUSION: It is suggested that type of cues influence in choice reaction. These data may helpful in designing not only effective motor learning training programs for healthy persons but also reeducation programs for patients with neurological dysfunction.

Functional Integration of Serial Dilution and Capillary Electrophoresis on a PDMS Microchip

  • Chang, Jun-Keun;Heo, Yun-Seok;Hyunwoo Bang;Keunchang Cho;Seok Chung;Chanil Chung;Han, Dong-Chul
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.8 no.4
    • /
    • pp.233-239
    • /
    • 2003
  • For the quantitative analysis of an unknown sample a calibration curve should be obtained, as analytical instruments give relative, rather than absolute measurements. Therefore, researchers should make standard samples with various known concentrations, measure each standard and the unknown sample, and then determine the concentration of the unknown by comparing the measured value to those of the standards. These procedures are tedious and time-consuming. Therefore, we developed a polymer based microfluidic device from polydimethylsiloxane, which integrates serial dilution and capillary electrophoresis functions in a single device. The integrated microchip can provide a one-step analytical tool, and thus replace the complex experimental procedures. Two plastic syringes, one containing a buffer solution and the other a standard solution, were connected to two inlet holes on a microchip, and pushed by a hydrodynamic force. The standard sample is serially diluted to various concentrations through the microfluidic networks. The diluted samples are sequentially introduced through microchannels by electro-osmotic force, and their laser-induced fluorescence signals measured by capillary electrophoresis. We demonstrate the integrated microchip performance by measuring the fluorescence signals of fluorescein at various concentrations. The calibration curve obtained from the electropherograms showed the expected linearity.

Signal Transmission Characteristics Improvement of Serial Advanced Technology Attachment Connector (SATA 커넥터의 신호 전달 특성 개선)

  • Yang, Jeong-Kyu;Kim, Moon-Jung
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.800-803
    • /
    • 2012
  • 본 논문에서는 SATA(Serial Advanced Technology Attachment) 커넥터의 차동 임피던스를 정합하여 신호 전달 특성을 개선한다. 3차원 FEM(Finite Elements Method) 전자기장 시뮬레이터를 이용하여 SATA 커넥터의 차동 모드 S-파라미터를 추출하고, 신호 전달 특성을 분석한다. SATA 커넥터의 반사 손실 ($S_{dd11}$)은 5 GHz 까지 20 dB 이하의 값을 나타내고, 삽입 손실($S_{dd21}$)은 0.1 dB 이하의 값을 나타낸다. 또한 인덕턴스, 커패시턴스, 상호 인덕턴스, 상호 커패시턴스를 추출하여 차동 임피던스를 계산한다. SATA 커넥터의 차동 임피던스는 107.3 ${\Omega}$으로 부정합이다. 차동 임피던스를 정합하기위해서 커넥터 신호 핀을 dx 방향으로 설계 변경한다. $d_x$ 방향으로 0.04 mm 증가 시켰을 때 차동 임피던스가 99.5 ${\Omega}$으로 최적으로 정합되었다. 또한 반사 손실은 1.5 GHz 에서 11 dB 개선되고, 삽입 손실은 최대 약 0.05 dB 개선되었다.

  • PDF