• Title/Summary/Keyword: safety alarm equipment

Search Result 35, Processing Time 0.026 seconds

Analysis of Unwanted Fire Alarm Signal Pattern of Smoke / Temperature Detector in the IoT-Based Fire Detection System (IoT 기반 화재탐지시스템의 연기 및 온도감지기 비화재보 신호 패턴 분석)

  • Park, Seunghwan;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.2
    • /
    • pp.69-75
    • /
    • 2022
  • Fire-alarm systems are safety equipment that facilitate rapid evacuation and early suppression in case of fire. It is highly desirable that fire-alarm systems have low false-alarm rates and are thus reliable. Until now, researchers have attempted to improve detector performance by applying new technologies such as IoT. To this end, IoT-based fire-detection systems have been developed. However, due to scarcity of large-scale operational data, researchers have barely studied malfunctioning in fire-alarm systems or attempted to reduce false-alarm rates in these systems. In this study, we analyzed false-alarm rates of smoke/temperature detectors and unwanted fire-alarm signal patterns at K institution, where Korea's largest IoT-based fire-detection system operates. After analyzing the fire alarm occurrences at the institution for five years, we inferred that the IoT-based fire-detection system showed lower false-alarm rates compared to the automatic fire-detection equipment. We analyzed the detection pattern by dividing it into two parts: normal operation and unwanted fire alarms. When a specific signal pattern was filtered out, the false-alarm rate was reduced to 66.9% in the smoke detector and to 46.9% in the temperature detector.

Bidirectional Alarm Equipment for Protection for Trackside Worker using Bone-anchored Speaker

  • Hwang, Jong-Gyu;Jo, Hyun-Jeong
    • International Journal of Safety
    • /
    • v.10 no.1
    • /
    • pp.36-40
    • /
    • 2011
  • Personnel maintaining or repairing the railway tracks or signaling facilities around tracks may experience the sensory disorder when doing maintenance works at the trackside of railway for long time. In this case personnel maintaining at the trackside may collide with the train since they cannot recognize the approach of motor-car although it approaches to the vicinity of maintenance workplace because of the sensory block phenomenon occurred due to their long hours of continued monotonous maintenance work. In order to prevent such motor-car accidents that may occur because railway track workers are unable to recognize the approaching train, the safety alarm equipment is developed to make the approaching motor-car send radio signals and bidirectional detection mechanism between approaching train and trackside personnel. It shows the possibility of utilization in various forms of safety equipment for workers only to the safety helmet to be worn by the maintenance workers while using the configuration of transmitting/receiving sides. In the paper it is represented new alarm equipment, which is the bone-anchored speaker-based safety helmet to be worn by the maintenance workers.

  • PDF

Analysis of Safety Alarm Mechanism for RF -based Equipment for Casualty Protection by Railway Maintenance Vehicle

  • Jo, Hyun-Jeong;Hwang, Jong-Gyu;Yoon, Yong-Ki
    • International Journal of Safety
    • /
    • v.9 no.2
    • /
    • pp.29-34
    • /
    • 2010
  • When doing maintenance works at the trackside of railway, the method which delivers information on approaching of train to maintenance workers through alarm devices such as the flag or indication light, etc., is being used by locating persons in charge of safety alarm in addition to the maintenance workers at fixed distances in the front and rear of the workplace. Workers maintaining at the trackside may collide with the train since they cannot recognize the approach of train although it approaches to the vicinity of maintenance workplace because of the sensory block phenomenon occurred due to their long hours of continued monotonous maintenance work. The clash or rear-end collision accidents between many maintenance trains called motor-cars can be occurred since there are cases where the signal systems for safe operation of motor-car such as track circuit etc. are blocked or not operated normally. We developed the new safety equipment for protection of trackside maintenance workers using radio frequency signals and bidirectional detection mechanism. The developed safety equipment must analyze the several operational mechanism for each different operation situations. In this paper the analysis results are represented.

Implementation of the Marine Fog Alarm Equipment using Photoelectric Element (광전소자를 이용한 선박용 안개 경보 장치 구현)

  • Kim, Kab-Ki
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.17 no.3
    • /
    • pp.265-268
    • /
    • 2011
  • In this paper, we designed and fabricated that fog alarm equipment detected to crew in maritime fog. Developed fog alarm equipment was combined sensor and a transmitter-receiver module using emitting device unit and receiver photoelectric element infrared LED using only the receive sensitivity was low, miniaturization. Experiment of the fabricated device had a standard that was humidity 70%, the fabricated one generating artificial-fog within visibility 1km. When humidity is over 70%, the fabricated one generates alarming sounds for a warning. When developed device apply to vessel will be able to respond quickly, according to dense fog in the accident.

Development of Safety Equipment for Protection of Trackside Personnel Maintaining Using Radio Frequency Equipment (선로변 작업자 철도교통 사상사고 예방을 위한 안전설비 개발)

  • Hwang, Jong-Gyu;Jo, Hyun-Jeong;Yoon, Yong-Ki;Kim, Yong-Kyu;Jang, Yeong-Jun;Ko, Yeong-Hwoang
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.5
    • /
    • pp.738-743
    • /
    • 2009
  • Personnel maintaining or repairing the railway tracks or signaling device around tracks may experience the sensory disorder when they do routine works for many hours and they may not recognize the leading to train accidents. In order to prevent such train accidents that may occur because railway track workers are unable to recognize the approaching train, a safety-equipment is developed to make the approaching train send signals. We developed the new alarm equipment for protection of trackside maintenance workers using radio signals.

The Basic Study On the Development of Ergonomic Integrated Bridge Alarm Management System (인간공학적 선교통합알람장치의 개발을 위한 기초 연구)

  • Yang, Young-Hoon;Yang, Chan-Su;Gong, In-Young;Lee, Bong-Wang
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.11 no.1 s.22
    • /
    • pp.17-22
    • /
    • 2005
  • According to the development if the ships navigational equipment, a bridge system has been improved but a marine accidents by human error haven't been reduced Recently our interest is concentrated on a suitable ergonomic arrangement and design of the ships bridge equipment to reduce an error due to human factors. The bridge alarm system should be designed to recognize the alarm informations as soon as possible and to deliver it clearly. Internationally, the matter is being discussed on the BAMS(Bridge Alarm Management System) in a view if a ergonomic bridge design, but a practical design method is not getting result.. In this paper I would like to review an application approach of human engineering ergonomics to a bridge alarm system and propose a conceptual design if the Ergonomic Integrated Bridge Alarm Management System(EIBAMS)

  • PDF

Development of Advanced Annunciator System for Nuclear Power Plants

  • Hong, Jin-Hyuk;Park, Seong-Soo;Chang, Soon-Heung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.185-190
    • /
    • 1995
  • Conventional alarm system has many difficulties in the operator's identifying the plant status during special situations such as design basis accidents. To solve the shortcomings, an on-line alarm annunciator system, called dynamic alarm console (DAC), was developed. In the DAC, a signal is generated as alarm by the use of an adaptive setpoint check strategy based on operating mode, and time delay technique is used not to generate nuisance alarms. After alarm generation, if activated alarm is a level precursor alarm or a consequencial alarm, it would be suppressed, and the residual alarms go through dynamic prioritization which provide the alarms with pertinent priorities to the current operating mode. Dynamic prioritization is achieved by going through the system- and mode-oriented prioritization. The DAC has the alarm hierarchical structure based on the physical and functional importance of alarms. Therefore the operator can perceive alarm impacts on the safety or performance of the plant with the alarm propagation from equipment level to plant functional level. In order to provide the operator with the most possible cause of the event and quick cognition of the plant status even without recognizing the individual alarms, reactor trip status tree (RTST) was developed. The DAC and the RTST have been simulated with on-line data obtained from the full-scope simulator for several abnormal cases. The results indicated that the system can provide the operator with useful and compact information fur the earlier termination and mitigation of an abnormal state.

  • PDF

A Case Study of the Characteristics of Fire-Detection Signals of IoT-based Fire-Detection System (사례 분석을 통한 IoT 기반 화재탐지시스템의 화재 감지신호 특성)

  • Park, Seung Hwan;Kim, Doo Hyun;Kim, Sung Chul
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.3
    • /
    • pp.16-23
    • /
    • 2022
  • This study aims to provide a fundamental material for identifying fire and no-fire signals using the detection signal characteristics of IoT-based fire-detection systems. Unlike analog automatic fire-detection equipment, IoT-based fire-detection systems employ wireless digital communication and are connected to a server. If a detection signal exceeds a threshold value, the measured values are saved to a server within seconds. This study was conducted with the detection data saved from seven fire accidents that took place in traditional markets from 2020 to 2021, in addition to 233 fire alarm data that have been saved in the K institute from 2016 to 2020. The saved values demonstrated variable and continuous VC-Signals. Additionally, we discovered that the detection signals of two fire accidents in the K institution had a VC-Signal. In the 233 fire alarms that took place over the span of 5 years, 31% of smoke alarms and 30% of temperature alarms demonstrated a VC-Signal. Therefore, if we selectively recognize VC-Signals as fire signals, we can reduce about 70% of false alarms.

On the Development of Ergonomic Integrated Bridge Alarm Management System (인간공학적 선교통합알람장치의 개발을 위한 기초 연구)

  • Yang Young-Hoon;Yang Chan-Su;Kim Hongtae;Gong In-Young;Lee Bong-Wang
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2005.05a
    • /
    • pp.1-6
    • /
    • 2005
  • According to the development of the ships navigational equipment, a bridge system has been improved but a marine accidents by human error haven't been reduced Recently It's concerned about a suitable ergonomic arrangement and design of the ships bridge equipment to reduce an error for human factors. The bridge alarm system should be designed to recognize the alarm informations as soon as possible, to deliver it clearly. Internationally, there have been a lively discussion on the BAMS(Bridge Alarm Management System) for a ergonomic bridge design, but the practical design method have not been published. In this article I would like to review a ergonomic conceptual design for the ships bridge alarm system and propose a conceptual design of the Ergonomic Integrated Bridge Alarm Management System(EIBAMS)

  • PDF

Embodiment of Firewall Block for Safety in the Cave (동굴 공간의 안전과 방재차단벽)

  • Kim, Bo-Su;Kim, Kang-Won;Kim, Tae-Hwan;Park, Jung-Ho;Lee, Yung-Jae;Soh, Dea-Wha
    • Journal of the Speleological Society of Korea
    • /
    • no.87
    • /
    • pp.8-13
    • /
    • 2008
  • The automatic firewall block and fire alarm system was embodied by using gas circuit and wireless communication equipment, using a smoke sensor (ST-QA1A) and RF Module. OR-CAD was also used for testing circuit system and experiment circuit after assembling circuit. As a result in experiment, the gas sensor detected well an imaginary smoke and worked reliably for driving action of firewall block motor and wireless warning alarm. Through the smoke sensitive perception from the fire, the warning alarm and the preventing fire propagation from the specific closed region were verified reliably. The gas sensor and RF module for firewall and fire alarm system were actually available.