• Title/Summary/Keyword: roof control

Search Result 272, Processing Time 0.03 seconds

Effect of Heating system on Roof garden for Turf growth (옥상 잔디녹화시 Heating system의 효과)

  • Koh, Seuk-Koo;Shin, Hong-Kyun;Tae, Hyun-Sook;Kim, Yong-Seon;Ahn, Gil-Man
    • Asian Journal of Turfgrass Science
    • /
    • v.23 no.2
    • /
    • pp.279-286
    • /
    • 2009
  • This study was carried out to utilize the waste heat from office building for turfgrass culture on a roof garden. Heating system had been installed in the middle of soil profile on the turf areas in the garden plots. The results showed that the installation of heating system increased the shoot density, turfgrass quality, coverage rate, and root length compared with the control plots. The surface temperature of heating plots reached at $10.9^{\circ}C$ when the control plot showed $0^{\circ}C$, however, the soil moisture content was decreased 1.9% by the heating system. When the height of the snow accumulation reached over a 15cm, the it took only 4 days to melt out completely, while the height did not changed those period at the control plots. When the water temperature in boiler increased to $60^{\circ}C$ from a proper temperature of $55^{\circ}C$ in turf growth, the desiccation from leaf tip was started to occur caused by drought stress. More detail research should be followed in stress physiology in turf management in roof garden operation.

Development of Concrete Method for Roof Planting (건물옥상 식재용 콘크리트공법의 개발)

  • 이상태;김진선;황정하;한천구
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.28 no.5
    • /
    • pp.48-57
    • /
    • 2000
  • This paper is dealing with the fundamental properties of planting concrete, replacing the existing cover concrete on the roof of a building. This study is to find out the physical characteristics of the planting concrete and rearing characteristics of the grass throughout the modeling experimental materials. As the results of the experiment, the physical properties of planting concrete show the following results; when the paste to aggregate ratio is 0.2~ 0.4, voids volume : 30~17%, unit weight: 1,710~2,010kg/m3, compressive strength : 45~145kgf/$\textrm{cm}^2$, its pH is more than 11, but is reduced to the proper degree for planting after being neutralized. Kentucky bluegrass covered with planting concrete is grown well. The planting concrete used with blast furnace slag cement shows a better properties at the height, the width and the covering rate by 1.1cm, 0.5mm and 7%, respectively, than those used with ordinary portland cement. Also, the less the paste to aggregate ratio is, the better the plant grows. The orders of the effects of temperature control are as follows; the system of planting concrete with grass>the system of planting concrete without grass>the system of mixed soil>the existed roof system. In case, the planting concrete is placed to the roofs of buildings instead of normal concrete slab, and a number of favorable effect can be expected such as the improvement os environmental factors, the reduction of construction cost, the saving of energy and the reduction of environment load. The future research on the change of a variety of the aggregate conditions and the application of the practical structures should be made, and also the research of the endurance also be performed.

  • PDF

A study on thermal simulation for extensive green roof system using a plant canopy model (식생캐노피모델을 통한 저관리 조방형 옥상녹화시스템의 열해석 전산모의에 관한 연구)

  • Kim, Tae Han
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.15 no.2
    • /
    • pp.137-147
    • /
    • 2012
  • GRS is an effective urban ecology restoration technique that can manage a variety of environmental functions such as ecological restoration, rainwater spill control and island heat effect from a low-impact development standpoint that can be utilized in new construction and retrofits. Recently, quantitative evaluation studies, both domestic and abroad, in the areas related to these functions, including near-earth surface climate phenomenon, heavy rainwater regulation, thermal environment of buildings, have been actively underway, and there is a trend to standardize in the form of technological standards. In particular, centered on the advanced European countries, studies of standardizing the specific insulation capability of buildings with green system that comprehensively includes the green roof, from the perspective of replacing the exterior materials of existing buildings, are in progress. The limitation of related studies in the difficulties associated with deriving results that reflect material characteristics of continuously evolving systems due in part to not having sufficiently considered the main components of green system, mechanisms of vegetation, soils. This study attempts to derive, through EnergyPlus, the effects that the vegetation-related indicators such as vegetation height, FCV, etc. have on building energy load, by interpreting vegetation and soil mechanisms through plant canopy model and using an ecological standard indicator LAI that represent the condition of plant growth. Through this, the interpretations that assume green roof system as simple heat insulation will be complemented and a more practical building energy performance evaluation method that reflects numerical methods for heat fluxes phenomena that occur between ecology restoration systems comprised of plants and soil and the ambient space.

Research on reinforcement mechanism of soft coal pillar anchor cable

  • Li, Ang;Ji, Bingnan;Zhou, Haifeng;Wang, Feng;Liu, Yingjie;Mu, Pengfei;Yang, Jian;Xu, Ganggang;Zhao, Chunhu
    • Geomechanics and Engineering
    • /
    • v.29 no.6
    • /
    • pp.697-706
    • /
    • 2022
  • In order to explore the stable anchoring conditions of coal side under the mining disturbance of soft section coal pillar in Wangcun Coal Mine of Chenghe Mining Area, the distribution model of the anchoring support pressure at the coal pillar side was established, using the strain-softening characteristics of the coal to study the distribution law of anchoring coal side support pressure. The analytical solution for the reinforcement anchorage stress in the coal pillar side was derived with the inelastic state mechanical model. The results show that the deformation angle of the roadway side and roof increases with the roof subsidence due to the mining influence at the adjacent working face, the plastic deformation zone extends to the depth of the coal side, and the increase of anchorage stress can effectively control the roof subsidence and further deterioration of plastic zone. The roadway height and the peak support pressure have a certain influence on the anchorage stress, the required anchorage stress of the coal side rises with the roadway height and the peak support pressure. The required anchorage stress of the coal pillar side decreases as the cohesion between the coal seam and the roof and floor and the anchor length increases. Then, applied the research result to Wangcun coal mine in Chenghe mining area, the design of anchor cable reinforcement support was proposed for the section of coal pillars side that has been anchored and deformed, which achieved great results and effectively controlled the convergence and deformation of the side, providing a safety guarantee for the roadway excavation and mining.

Distribution of Wind Force Coefficients on the Single-span Arched House (아치형 단동하우스의 풍력계수 분포에 관한 연구)

  • 이석건;이현우
    • Journal of Bio-Environment Control
    • /
    • v.1 no.1
    • /
    • pp.28-36
    • /
    • 1992
  • The wind pressure distributions were analyzed to provide fundamental criteria for the structural design on e single-span arched house according to the wind directions through the wind tunnel experiment. In order to investigate the wind force distributions, the variation of the wind force coefficients, the mean wind force coefficients, the drag force coefficients and the lift force coefficients were estimated by using the experimental data. The results obtained are as follows: 1. When the wind direction was normal to the wall, the maximum positive wind pressure along the height of the wall occurred approximately at two-thirds of the wall height because of the effects of boundary layer flow. 2. When the wind direction was 30$^{\circ}$ to the wall, the maximum positive wind force occurred at the windward edge of the wall. When the wind direction was parallel to the wall, the maximum negative wind force occurred at the windward edge of the wall. 3. The maximum negative wind force along the width of the roof appeared around the width ratio, 0.4, and that along the length of the roof appeared around the length ratio, 0.5. 4. According to the results of the mean wind force coefficients analysis, the maximum negative wind force occurred on the roof at the wind direction of 30$^{\circ}$. 5. The wind forces at the wind direction of 30$^{\circ}$ instead of 0$^{\circ}$ are recommended in the structural design of supports for a house. 6. To prevent partial damage of a house structure by wind forces, the local wind forces should be considered to the structural design of a house.

  • PDF

Distribution of Wind Force Coefficients on the Two-span Arched House (아치형 2연동하우스의 풍력계수 분포에 관한 연구)

  • 이석건;이현우
    • Journal of Bio-Environment Control
    • /
    • v.1 no.2
    • /
    • pp.142-147
    • /
    • 1992
  • The wind pressure distributions were analyzed to provide fundamental criteria for the structural design on the two-span arched house according to the wind directions through the wind tunnel experiment. In order to investigate the wind force distributions, the variation of the wind force coefficients, the mean wind force coefficients, the drag force coefficients and the lift force coefficients were estimated using the experimental data. The results obtained are as follows : 1. The variation of the wind force with wind directions on the side walls was the greatest at the upwind edge of the walls. 2. The maximum negative wind force along the length of the roof appeared at the upwind edge at the wind direction of 60$^{\circ}$. 3. The maximum negative wind force along the width of the roof appeared at the width ratio and wind direction of 0$^{\circ}$ and 0.4 in the first house and 0.6 and 30$^{\circ}$ in the second house, respectively. 4. The mean negative wind force on the side walls of the first house at the wind direction of 0$^{\circ}$ was far greater than that of the second house, and the maximum negative wind force on the roof occurred at the wind direction of 30$^{\circ}$. 5. The maximum lift force appeared on the second house at the wind direction of 30$^{\circ}$, but the lift force on the first house was far greater than that on the second house at the wind direction of 0$^{\circ}$. 6. The parts to be considered for the local wind forces were the edges of the walls, and the edges of the x-direction and the width ratio, 0.4 of the y-direction in the roofs.

  • PDF

Stability analysis of coal face based on coal face-support-roof system in steeply inclined coal seam

  • Kong, Dezhong;Xiong, Yu;Cheng, Zhanbo;Wang, Nan;Wu, Guiyi;Liu, Yong
    • Geomechanics and Engineering
    • /
    • v.25 no.3
    • /
    • pp.233-243
    • /
    • 2021
  • Rib spalling is a major issue affecting the safety of steeply inclined coal seam. And the failure coal face and support system can be affected with each other to generate a vicious cycle along with inducing large-scale collapse of surrounding rock in steeply inclined coal seam. In order to analyze failure mechanism and propose the corresponding prominent control measures of steeply inclined coal working face, mechanical model based on coal face-support-roof system and mechanical model of coal face failure was established to reveal the disaster mechanism of rib spalling and the sensitive analysis of related factors was performed. Furthermore, taking 3402 working face of Chen-man-zhuang coal mine as engineering background, numerical model by using FLAC3D was built to illustrate the propagation of displacement and stress fields in steeply inclined coal seam and verify the theory analysis as mentioned in this study. The results show that the coal face slide body in steeply inclined working face can be observed as the failure height of upper layer smaller than that of lower layer exhibiting with an irregular quadrilateral pyramid shape. Moreover, the cracks were originated from the upper layer of sliding body and gradually developed to the lower layer causing the final rib spalling. The influence factors on the stability of coal face can be ranked as overlying strata pressure (P) > mechanical parameters of coal body (e.g., cohesion (c), internal fraction angle (φ)) > support strength (F) > the support force of protecting piece (F') > the false angle of working face (Θ). Moreover, the corresponding control measures to maintain the stability of the coal face in the steeply inclined working face were proposed.

Development of AI Image Analysis Emergency Door Opening and Closing System linked Wired/Wireless Counting (유무선 카운팅 연동형 AI 영상분석 비상문 개폐 시스템 개발)

  • Cheol-soo, Kang;Ji-yun, Hong;Bong-hyun, Kim
    • Journal of Digital Policy
    • /
    • v.1 no.2
    • /
    • pp.1-8
    • /
    • 2022
  • In case of a dangerous situation, the roof, which serves as an emergency exit, must be open in case of fire according to the Fire Act. However, when the roof door is opened, it has become a place of various incidents and accidents such as illegal entry, crime, and suicide. As a result, it is a reality to close the roof door in terms of facility management to prevent crime, various incidents, and accidents. Accordingly, the government is pushing to legislate regulations on housing construction standards, etc. that mandate the installation of electronic automatic opening and closing devices on rooftop doors. Therefore, in this paper, an intelligent emergency door opening/closing device system is proposed. To this end, an intelligent emergency door opening and closing system was developed by linking wired and wireless access counting and AI image analysis. Finally, it is possible to build a wireless communication-based integrated management platform that provides remote control and history management in a centralized method of device status real-time monitoring and event alarm.

Experimental study on rock-coal-rock composite structure with different crack characteristics

  • Li, Tan;Chen, Guangbo;Li, Qinghai
    • Geomechanics and Engineering
    • /
    • v.29 no.4
    • /
    • pp.377-390
    • /
    • 2022
  • The stability of the roof rock-coal pillar-floor rock composite structure is of great significance to coal mine safety production. The cracks existing in the composite structure seriously affect the stability of the roof rock-coal pillar-floor rock composite structure. The numerical simulation tests of rock-coal-rock composite structures with different crack characteristics were carried out to reveal the composite structures' mechanical properties and failure mechanisms. The test results show that the rock-coal-rock composite structure's peak stress and elastic modulus are directly proportional to the crack angle and inversely proportional to the crack length. The smaller the crack angle, the more branch cracks produced near the main control crack in the rock-coal-rock composite structure, and the larger the angle between the main control crack and the crack. The smaller the crack length, the larger the width of the crack zone. The impact energy index of the rock-coal-rock composite structure decreases first and then increases with the increase of crack length and increases with the increase of crack angle. The functional relationships between the different crack characteristics, peak stress, and impact energy index are determined based on the sensitivity analysis. The determination of the functional relationship can fully grasp the influence of the crack angle and the crack length on the peak stress and impact energy index of the coal-rock composite structure. The research results can provide a theoretical basis and guidance for preventing the instability and failure of the coal pillar-roof composite structure.