A study on thermal simulation for extensive green roof system using a plant canopy model

식생캐노피모델을 통한 저관리 조방형 옥상녹화시스템의 열해석 전산모의에 관한 연구

  • Kim, Tae Han (Dept. of Environmental Landscape Architecture, Sang Myung University)
  • Received : 2012.03.07
  • Accepted : 2012.04.09
  • Published : 2012.04.30

Abstract

GRS is an effective urban ecology restoration technique that can manage a variety of environmental functions such as ecological restoration, rainwater spill control and island heat effect from a low-impact development standpoint that can be utilized in new construction and retrofits. Recently, quantitative evaluation studies, both domestic and abroad, in the areas related to these functions, including near-earth surface climate phenomenon, heavy rainwater regulation, thermal environment of buildings, have been actively underway, and there is a trend to standardize in the form of technological standards. In particular, centered on the advanced European countries, studies of standardizing the specific insulation capability of buildings with green system that comprehensively includes the green roof, from the perspective of replacing the exterior materials of existing buildings, are in progress. The limitation of related studies in the difficulties associated with deriving results that reflect material characteristics of continuously evolving systems due in part to not having sufficiently considered the main components of green system, mechanisms of vegetation, soils. This study attempts to derive, through EnergyPlus, the effects that the vegetation-related indicators such as vegetation height, FCV, etc. have on building energy load, by interpreting vegetation and soil mechanisms through plant canopy model and using an ecological standard indicator LAI that represent the condition of plant growth. Through this, the interpretations that assume green roof system as simple heat insulation will be complemented and a more practical building energy performance evaluation method that reflects numerical methods for heat fluxes phenomena that occur between ecology restoration systems comprised of plants and soil and the ambient space.

Keywords

References

  1. BATS (Biosphere-Atmosphere Transfer Scheme), Dickinson, R.E., Henderson-Sellers, P.J. Kennedy, and M.F. Wilson. 1986. BATS for the NCAR community climate model. NCAR Technical Note, TN-275+STR.
  2. SiB (Simple Biosphere model). Sellers, P.J., Y. Mintz, Y.C. Sud, and A. Dalcher. 1986. A simple biosphere model (SiB) for use within general circulation models. Journal of Atmospheric Science, 43(6), pp. 505-532. https://doi.org/10.1175/1520-0469(1986)043<0505:ASBMFU>2.0.CO;2
  3. FASST (Fast All Season Soil Strength), Frankenstein, S., and G. Koenig. 2004. FASST Vegetation Models. U.S. Army Engineer Research and Development Center, Cold regions Research and Engineering Laboratory, ERDC/CRREL Technical Report TR-04-25.
  4. Joseph T. Woolley, (1971) Reflectance and Transmittance of Light by Leaves. Plant Physiology.
  5. EnergyPlus Engineering Reference, US Department of Energy.
  6. EnergyPlus Input-Output Reference, US Department of Energy.
  7. 석호태.양정훈.정태웅. 2008. 학교건물에서의 외피녹화에 따른 에너지성능 평가에 관한 연구. 한국태양에너지학회 논문집 28(6) : 40-47.
  8. 한승원.김형숙.이동우. 2010. 인공지반 녹화용 지피식물의 열성능 평가. 한국건축친환경설비학회 춘계학술발표대회 : 235-239.
  9. 황효근.송두삼. 2009. 공동주택 단지 내 지반 특성 및 지반 구성에 따른 열적 특성에 관한 연구. 한국태양에너지학회 논문집 29(5) : 88-97.

Cited by

  1. Assessment of Temperature Reduction and Heat Budget of Extensive Modular Green Roof System vol.31, pp.4, 2013, https://doi.org/10.7235/hort.2013.13001
  2. A Study on Monitoring to Investigate Dynamic Temperature Model by Sensible Heat Flux of Green Roof System vol.18, pp.6, 2015, https://doi.org/10.13087/kosert.2015.18.6.15
  3. Assessment of Temperature Reduction and Evapotranspiration of Green Roof Planted with Zoysia japonica vol.22, pp.11, 2013, https://doi.org/10.5322/JESI.2013.22.11.1443
  4. A Study on Computer Simulation to Investigate Correlations between Temperature Controlling Effect of Green Roof System and the Photovoltaic Power Generation Efficiency vol.33, pp.4, 2013, https://doi.org/10.7836/kses.2013.33.4.070