• Title/Summary/Keyword: respiration characteristics

Search Result 251, Processing Time 0.032 seconds

Characteristics of soil respiration temperature sensitivity in a Pinus/Betula mixed forest during periods of rising and falling temperatures under the Japanese monsoon climate

  • Oe, Yusuke;Yamamoto, Akinori;Mariko, Shigeru
    • Journal of Ecology and Environment
    • /
    • v.34 no.2
    • /
    • pp.193-202
    • /
    • 2011
  • We studied temperature sensitivity characteristics of soil respiration during periods of rising and falling temperatures within a common temperature range. We measured soil respiration continuously through two periods (a period of falling temperature, from August 7, 2003 to October 13, 2003; and a period of rising temperature from May 2, 2004 to July 2, 2004) using an open-top chamber technique. A clear exponential relationship was observed between soil temperature and soil respiration rate during both periods. However, the effects of soil water content were not significant, because the humid monsoon climate prevented soil drought, which would otherwise have limited soil respiration. We analyzed temperature sensitivity using the $Q_{10}$ value and $R_{ref}$ (reference respiration at the average temperature for the observation period) and found that these values tended to be higher during the period of rising temperature than during the period of falling temperature. In the absence of an effect on soil water content, several other factors could explain this phenomenon. Here, we discuss the factors that control temperature sensitivity of soil respiration during periods of rising and falling temperature, such as root respiration, root growth, root exudates, and litter supply. We also discuss how the contribution of these factors may vary due to different growth states or due to the effects of the previous season, despite a similar temperature range.

Respiration Measurement Sleeping Pillow System (호흡 측정 수면베개 시스템)

  • Ahn, Dohyun;Minh, Tran;Lee, Jongmin;Park, Jaehee
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.280-285
    • /
    • 2017
  • This paper presents a respiration measurement sleeping pillow based on pressure sensors. The respiration measurement sleeping pillow system consists of a sleeping pillow, an interface circuit, a respiration measurement system, and four force-sensitive resistor(FSR) sensors attached at the bottom of the sleeping pillow. The FSR sensors are used to detect the respiration signals induced by the body movement while breathing. The respiration signals of a twenty health man were measured and analyzed by utilizing the respiration measurement sleeping pillow system. The pillow system could detect the respiration signals and had similar characteristics to the chest type BIOPAC respiration sensor used by medical doctors. The respiration rates of ten subjects were also measured. The average measurement accuracy was about 98.8%. The research results showed that this pillow system can be used to detect and analyze the respiration signal when sleeping for the better sleep management.

Soil Respiration Characteristics in Pinus densiflora Forests in Republic of Korea: A Case of Mt. Jeombongsan, Mt. Namsan, and Mt. Jirisan (2009~2010) (우리나라 소나무림의 토양호흡 특성: 점봉산, 남산, 지리산 사례 연구 (2009~2010))

  • Jae-Ho Lee;Young-Ju Yu;Sang-Hun Lee;Man-Seok Shin;Jae-Seok Lee
    • Korean Journal of Ecology and Environment
    • /
    • v.56 no.4
    • /
    • pp.440-448
    • /
    • 2023
  • This study measured soil respiration in pine forests dominated by Pinus densiflora in Mt. Jeombong, Mt. Namsan, Mt. Jirisan in Republic of Korea from 2009 to 2010. The seasonal variations, along with temperature and soil moisture content, were measured to understand the characteristics at each site. Soil respiration was highest in summer and autumn, closely influenced by the increase in soil temperature. Throughout the measurement period, soil respiration ranged from 205.6 to 312.2 mg CO2 m-2 h-1, with Mt. Namsan showing the highest values and Mt. Jirisan the lowest. A strong correlation was observed between soil respiration and soil temperature, with Q10 values ranging from 2.5 to 3.0. Precipitation significantly affected soil moisture content, and although it appeared to influence soil respiration, no significant correlation was found.

Performance Enhancement of Ultrasonic Sensitivity by Improving the Transmitter Circuit

  • Lee, Cheul-Won;Kim, Young-Kil
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.4
    • /
    • pp.164-169
    • /
    • 2006
  • We have developed the spirometer system; many patients having weak respiration have difficulties in using conventional spirometers in hospitals, because their weak breath can be affected by the errors of inertia and instrumental pressure. We have developed a new ultrasound spirometer using an ARM 920T processor. To detect weak respiratory signals, we add a comparator circuit, which can afford more information of respiration characteristics such as respiration volume, directions, and velocities. We have also developed Gill for graphical display of respiration characteristics. Through the pilot test, it has been verified that the developed spirometer is operating reliably.

A Study on the Effects of Meditative Respiration Training on the Changes of Stress Hormones (명상호흡 수련이 스트레스성 호르몬에 미치는 영향에 관한 연구)

  • Park, Sang-Kyu
    • The Korean Journal of Emergency Medical Services
    • /
    • v.8 no.1
    • /
    • pp.47-55
    • /
    • 2004
  • The purpose of this study were to investigate the effect of meditative respiration training for 6weeks on the changes of ACTH and Cortisol which are stress hormones in 10 male workers. The results of this study were as follows : 1. After meditative respiration training for 6weeks, the changes of heart rate, respiratory rate, SBP, DBP were slightly decreased. 2. After meditative respiration training for 6weeks, the changes of ACTH hormone were significantly decreased(p<.01). 3. After meditative respiration training for 6weeks, the changes of cortisol hormone were significantly decreased(p<.05). The above conclusions suggested that short-term meditative respiration training was an effective training method to changes mental emotional states and physiological stress hormone level affirmatively. Further, the future researches must analyze the physiological and psychological characteristics affecting mental health synthetically and develop meditative respiration program suitable to the various items and classes, especially EMT.

  • PDF

Development of New Stacked Element Piezoelectric Polyvinylidene Fluoride Pressure Sensor for Simultaneous Heartbeat and Respiration Measurements (PVDF 압전소자를 이용한 심장박동 및 호흡수 동시측정센서개발)

  • Park, Chang-Yong;Kweon, Hyun-Kyu;Lee, So-Jin;Manh, Long-Nguyen
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.4
    • /
    • pp.100-108
    • /
    • 2019
  • In this paper, a new stacked element pressure sensor has proposed for heartbeat and respiration measurement. This device can be directly attached to an individual's chest; heartbeat and respiration are detected by the pulsatile vibration and deformation of the chest. A key feature of the device is the simultaneous measurement of heart rate and respiration. The structure of the sensor consists of two stacked elements, in which one element includes one polyvinylidene fluoride (PVDF) thin film bonded on polydimethylsiloxane (PDMS) substrate. In addition, for the measurement and signal processing, the electric circuit and the filter are simply constructed with an OP-amp, resistance, and a capacitor. One element (element1, PDMS) maximizes the respiration signal; the other (element2, PVDF) is used to measure heartbeat. Element1 and element2 had sensitivity of 0.163V/N and 0.209V/N, respectively, and element2 showed improved characteristics compared with element1 in response to force. Thus, element1 and element2 were optimized for measuring respiration heart rate, respectively. Through mechanical and vivo human tests, this sensor shows the great potential to optimize the signals of heartbeat and respiration compared with commercial devices. Moreover, the proposed sensor is flexible, light weight, and low cost. All of these characteristics illustrate an effective piezoelectric pressure sensor for heartbeat and respiration measurements.

Comparison of respiration characteristics on the new variety of oyster mushroom according to the growth temperature (신품종 느타리버섯의 생육온도에 따른 호흡특성 비교)

  • Jang, Myoung-Jun;Ha, Tae-Moon;Ju, Young-Cheol
    • Journal of Mushroom
    • /
    • v.5 no.2
    • /
    • pp.65-70
    • /
    • 2007
  • This study was carried out to find out respiration characteristics of new variety of oyster mushroom to the temperature response. In new species of oyster mushroom, the account of respiration was on the increase when the growth temperature with the passage of growth stage was on the rise. The $CO_2$ concentration was accelerated as increasing the growth temperature, whereas the $O_2$ concentration was decreased. The account of respiration of new variety was in the descending order, Hukbaek>Jinmi>Chungpung>Suhan2>Chunchu2. Also, the ventilation exponent at $15^{\circ}C$ was Suhan2 2 ~12%, Chungpung 9~24%, Jinmi 15~37%, Hukbaek 17~39% in proportion to Chunchu2. The experiments related to respiration characteristics of new variety of oyster mushroom were worthy of recommending to new variety cultivator.

  • PDF

A Study of Correlation between Pulse-Respiration Ratio and Characteristics of Thermal Temperature (체표온도특성(體表溫度特性)과 맥율(脈率)의 상관성(相關性) 연구(硏究))

  • Lee, Hyuk-Jae;Park, Young-Jae;Park, Young-Bae;Oh, Hwan-Sup
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.1
    • /
    • pp.103-130
    • /
    • 2008
  • Background: For standardizing of Han-Yeol [寒熱], which is a kind of diagnosis method in oriental medicine, it is necessary to investigate into relationship of symptoms and signs representative of Han-Yeol [寒熱] to the biofunctional medical signals; thermal temperature by Thermography, Pulse-Respiration Ratio and so on. By correlation analysis of these data items acquired from patients, it could be provides the fundamental data for standardizing of Han-Yeol [寒熱]. Objectives: We performed this study to check the characteristics of thermal temperature with Han-Yeol [寒熱] statue by pulse-respiration ratio. Methods: We selected nine regions around acupoints including Yin dang[印堂], Sugu[水溝, GV26], Ch'ondol[天突, CV22], Chonjung[CV17], Chung-wan[中脘, CV12], Chonchu[天樞 S25], No-gung[勞官, P8], and calculated based on the utility of R.O.I.(Region of Integer) by IR-2000 these points temperature from 68 subjects. In practicing pulse-respiration ratio over 4.0 means the statues of Yeol [熱], pulse-respiration ratio below 4.0 means the statues of Han [寒]. To optimum conditions thermal temperature, which are not effected by internal and external variables, we studied preceding research. The results shows that optimal time period is 20minutes after undressed and the optimal region is the region around acupoints including Sugu [水溝, GV26]. Based on a preceding research results, we analyzed these data by Paired T-test between GV26 Region and 8-Thermography Regions and two-way repeated ANOVA with thermography$({\Delta}T)$ and Han-Yeol [寒熱] statue by pulse-respiration ratio. Results: 1. In applying of two-way repeated ANOVA with thermography$({\Delta}T)$ and Han-Yeol [寒熱] statue by pulse-respiration ratio, Sugu [水溝穴, GV26] - [印堂穴, HN1], Sugu 水溝, GV26] - Chonjung[CV17], Sugu [水溝, GV26] -Chung-wan[中脘, CV12]had significant differences. 2. In applying of Paired T-test between Sugu [水溝穴, GV26] Region and 8- Thermography Regions, there were significant differences except of Sugu [水溝穴, GV26] -Chondolp[天突, CV22]. 3. In the difference of Sugu [水溝, GV26] -Chung-wan[中脘, CV12], thermal temperature increases a lot in the statues of Yeol [熱], thermal temperature decreases a lot in the statues of Han [寒]. Conclusions: On the analysis of Thermography, we obtain the measurement conditions were considered the individual variations. And it is different that the thermal temperature change on Thermography according to Han-Yeol [寒熱] statue by pulse-respiration ratio.

  • PDF

Miniaturized Sensor Interface Circuit for Respiration Detection System (호흡 검출 시스템을 위한 초소형 센서 인터페이스 회로)

  • Jo, Sung-Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.8
    • /
    • pp.1130-1133
    • /
    • 2021
  • In this paper, a miniaturized sensor interface circuit for the respiration detection system is proposed. Respiratory diagnosis is one of the main ways to predict various diseases. The proposed system consists of respiration detection sensor, temperature sensor, and interface circuits. Electrochemical type gas sensor using solid electrolytes is adopted for respiration detection. Proposed system performs sensing, amplification, analog-to-digital conversion, digital signal processing, and i2c communication. And also proposed system has a small form factor and low-cost characteristics through optimization and miniaturization of the circuit structure. Moreover, technique for sensor degradation compensation is introduced to obtain high accuracy. The size of proposed system is about 1.36 cm2.

Studies on the Characters of Green-stem Varient Ginseng Plant (청경종의 제형질 특성에 관하여)

  • 천성룡;김경태
    • Journal of Ginseng Research
    • /
    • v.13 no.2
    • /
    • pp.153-157
    • /
    • 1989
  • The characteristics of the areal parts, photosynthetic and respiration rates and stem color were examined in 1- to 5-year-old Green-stem, Violet-stem and Yellow-berry variant ginseng (Panax ginseng C.A. Meyer). The top characteristics, photosynthetic and respiration rates were not significantly different among the three variants. Selfed progency of the Green-stems variant plant produced only green stems, while the others produced green and violet stem in the seedling stage. These results showed that most of the top characteristics of the Green-stem variant were similar those of the Violet-stem and Yellow-berry variants with age.

  • PDF