DOI QR코드

DOI QR Code

Performance Enhancement of Ultrasonic Sensitivity by Improving the Transmitter Circuit

  • Lee, Cheul-Won (Department of Biomedical Engineering, Ajou University) ;
  • Kim, Young-Kil (Department of Electronic Engineering, Ajou University)
  • Published : 2006.08.01

Abstract

We have developed the spirometer system; many patients having weak respiration have difficulties in using conventional spirometers in hospitals, because their weak breath can be affected by the errors of inertia and instrumental pressure. We have developed a new ultrasound spirometer using an ARM 920T processor. To detect weak respiratory signals, we add a comparator circuit, which can afford more information of respiration characteristics such as respiration volume, directions, and velocities. We have also developed Gill for graphical display of respiration characteristics. Through the pilot test, it has been verified that the developed spirometer is operating reliably.

Keywords

References

  1. Shkundin, S.Z. and Kremlijova, O.A, 'A Method for Calculating Acoustic Fields in a Finite Cylindrical Channel with a Flow,' Acoustical Physics, vol. 44, no. 1, 1998
  2. John G Webster, Medical Instrumentation Application and Design, JOHN WILEY & SONS, 3th Edition, 1998
  3. Quanjer Ph H, Tammeling GJ, Cotes JE, Pedersen OF,Peslin R, Yemault J-C., 'Lung Volumes and Forced Ventilatory Flows' Official Statement of the European Respiratory Society, Report Working party, Standardization of Lung Function Tests, European Community for Steel and Coal. European Respiratory Journal, vol. 6, Suppl 16, pp.5-40, 1993 https://doi.org/10.1183/09041950.005s1693
  4. European Respiratory Society, 'Lung volumes and forced ventilator flows. Report working party on Standardization of Lung Function tests' Eur Respir J, vol. 6, Suppl 16, pp.5-40, 1993 https://doi.org/10.1183/09041950.005s1693
  5. Laszlo G, Lance GN, Lewis GTR, Hughes AO, 'The contribution of respiratory fimction tests in clinical diagnosis,' Eur Prespir J, pp.983-990, 1993
  6. Shkudin, S.Z. and Lashin, V.B., 'Phase Method of Acoustic Anemometry,' Metrologiya, no. 7, pp.39-43, 1990
  7. Russel NJ, Crichton NJ, Emmerson PA, Morgan AD, 'Quantitative assessment of the value of spirometry' Thorax, pp.360-363, 1986.8. American Thoracic Society Statement, 'Standardization of spirometry' 1994 update, Am J Pespir Care, pp.1107-1136, 1991
  8. JMlF, Flux Measurement A to Z, Techhouse, 1997, pp.121-141
  9. 'Sensitivity Enhancement of Spirometer Employing Ultrasonic Method,' J. Biomed. Eng. Res., vol. 26, no. 6, pp.351-356, 2005