• Title/Summary/Keyword: radiation power

Search Result 1,954, Processing Time 0.028 seconds

Performance Analysis of Electronic Personal Dosimeter(EPD) for External Radiation Dosimetry (전자개인선량계(EPD)의 외부피폭방사선량 평가 성능분석)

  • Lee, Byoung-Il;Kim, Taejin;Lim, Young-Khi
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.4
    • /
    • pp.261-266
    • /
    • 2015
  • As performance of electronic personal dosimeter (EPD) used for auxiliary personal dosimeter in nuclear power plants (NPPs) has been being continuously improved, we investigated application cases in Korea and other countries and also tested it in NPPs to assess the performance of EPD for external radiation dosimetry. Result of performance tests done in domestic NPPs was similar to those obtained by IAEA in cooperation with EURADOS (IAEA-TECDOC-1564). In addition, EPD/TLD dose ratio has shown similar tendency of EPD/Film-badge dose ratio from the research by the Japan Atomic Power Company (JAPC) and EPD provided more conservative value than TLD or Film-badge. Although some EPD's failures have been discussed, EPD has shown continuous improvement according to the report of Institute of Nuclear Power Operation (INPO) and data from domestic NPPs. In conclusion, It is considered that the general performance of EPD is adequate for external radiation dosimetry compared with that of TLD, providing appropriate performance checking procedure and alternative measures for functional failure.

Exposure of the Population in the United States to Ionizing Radiation

  • Carter Melvin W.;Oliver Robert W.
    • Journal of Radiation Protection and Research
    • /
    • v.12 no.2
    • /
    • pp.37-50
    • /
    • 1987
  • The exposure of the population in the United States to ionizing radiation has recently been evaluated by the National Council on Radiation Protection and Measurements (NCRP). This was done by constituting six organizational groups to address various phases of the work and the results of this work are summarized in this article. The article is based on the report, by the same title, which is scheduled for publication by the NCRP in September, 1987. The six organizational groups are titled Radiation Exposure from Consumer Products, Natural Background Radiation, Radiation Associated with Medical Examinations, Radiation Received by Radiation Employees, Public Exposure from Nuclear Power, and Exposure from Miscellaneous Environmental Sources. These titles are descriptive of the subject areas covered by each of these separate groups. The data evaluated are for the years 1977-1984 with the majority of the data being for the period 1980-1982. Summary information is presented and discussed for the number of people exposed to given sources, the effective dose equivalent, the average effective dose equivalent to the U.S. population, and the genetically significant dose equivalent. The average annual effective dose equivalent from all sources to the U.S. population is approximately 3.6 mSv (360 mrem). Exposures to natural sources make the largest contribution to this total. Radon and radon decay products contribute 2.0 mSv (200 mrem) whereas the other naturally occurring radionuclides contribute 1.0 mSv (100 mrem). Among man-made or enhanced sources, medical exposures make the largest additional contributions, namely 0.39 mSv (39 mrem) for diagnosis and 0.14 mSv (14 mrem) for nuclear medicine. It was not possible to evaluate exposures for therapy. Most of the other sources of population exposure, including nuclear power and consumer products, are minor. A possible exception would be the use of tobacco products. These exposures are discussed in relation to a negligible individual risk level of $10{\mu}Sv/y$ (1 mrem/y). The NCRP considers exposures below the negligible individual risk level as trivial and as such should be dismissed.

  • PDF

Effect of Radiation Resistance by Chitosan through Micronuclei Test after X-ray Irradiation (키토산의 방사선 저항 효과에 관한 연구)

  • Kim Jung-Sam
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.28 no.1
    • /
    • pp.34-38
    • /
    • 2002
  • As the radiation is widely used in atomic power generation and medical parts. If it was not very carefully treated, Especially, to consideration of the perspicacity ability of radiation or radionuclide will be caused cytogenetic damages. To evaluation of

  • PDF

ALARA for Nuclear Power Plant Operation (원자력발전소가동(原子力發電所稼動)에 대한 ALARA)

  • Knapp Peter James
    • Journal of Radiation Protection and Research
    • /
    • v.4 no.1
    • /
    • pp.29-35
    • /
    • 1979
  • Comparison of the risk of death due to radiation exposure with the same risk due to occupational hazards in other safe industries underlines the importance of the ALARA principle. The outlined responsibilities and listed examples presented here can serve as a basis for expanding and developing the concepts necessary for its successful application.

  • PDF

Effect of Linear Polarized Near-Infrared Ray Radiation on the Experimental Pain Threshold in Healthy Subjects (직선 편광 근적외선 조사가 건강인의 실험적 통증역치에 미치는 영향)

  • Lee, Jae-Hyoung;Song, In-Young;Choi, Eun-Young
    • Journal of Korean Physical Therapy Science
    • /
    • v.2 no.4
    • /
    • pp.771-778
    • /
    • 1995
  • The purpose of this study was to determine the effects of linear polarized near-infrared ray radiation on experimental pain threshold in healthy adult subjects. Thirty healthy adult subjects were divided into 5 groups: 1) group 1, super lizer radiation at 0 % ; 2) group 2, super lizer radiation at 10 % ; 3) group 3, super lizer radiation at 20 % ; 4) group 4, super lizer radiation at 40 % ; 5) group 5, super lizer radiation at 80 %. The polarized near-infrared ray radiation was applied on LI 4 point of subject's right hand at a fixed time for 30 second. Experimental pain threshold were measured with electrical current on the right hand at 5 intervals for each radiation: 1) pretreat; 2) posttreat ; 3) posttreat of 1/2 hr ; 4) posttreat of 1 hr ; and 5) posttreat of 2 hrs. Data were analyzed using analyses of variance with repeated measures for pain threshold. No significant interaction between power output and time for pain threshold was found. Significant effects of power output and time for experimental pain threshold were found. Significant increase was noted in experimental pain threshold in group 4 and group 5 at posttreat, posttreat of 1/2, 1 hr and 2 hrs as a result of the applications of the polarized near-infrared ray radiation. This study indicate that polarized near-infrared ray radiation with above 40 % of power output increases pain threshold, thus possibly increasing options in choosing radiation output for treating pateint with pain. Further study is needed to compare the effects of these radiation in patients with clinical pain.

  • PDF

Advances in gamma radiation detection systems for emergency radiation monitoring

  • Kumar, K.A. Pradeep;Sundaram, G.A. Shanmugha;Sharma, B.K.;Venkatesh, S.;Thiruvengadathan, R.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2151-2161
    • /
    • 2020
  • The study presents a review of research advancements in the field of gamma radiation detection systems for emergency radiation monitoring, particularly two major sub-systems namely (i) the radiation detector and (ii) the detection platform - air-borne and ground-based. The dynamics and functional characteristics of modern radiation detector active materials are summarized and discussed. The capabilities of both ground-based and aerial vehicle platforms employed in gamma radiation monitoring are deliberated in depth.

A Study on a Human Body Detection Sensor Using Microwave Radiometer Technologies (마이크로파 라디오미터 기술을 응용한 인체 감지 센서에 관한 연구)

  • Son, Hong-Min;Park, Hong-Kyun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.3
    • /
    • pp.333-340
    • /
    • 2015
  • In this paper, we propose a passive microwave sensor for detecting human body using microwave radiometer technologies. The proposed sensor detects human body by measuring the change of the received radiation power from fixed background object due to human body. A C-band microwave radiometer is designed and implemented. The received radiation power changes due to human body is measured by the C-band microwave radiometer, and the effectiveness of the proposed sensor is evaluated by the measurement result analysis.

Optimal Adherent Position of Viscoelastic Material for the Reduction of Sound Power Radiated from the Stiffened Plate (보강판의 방사소음저감을 위한 제진재의 최적 위치 선정)

  • Kim, Sa-Su;Jo, Dae-Seung;An, Ho-Il;Jeong, Sang-Min
    • Journal of Ocean Engineering and Technology
    • /
    • v.12 no.2 s.28
    • /
    • pp.22-32
    • /
    • 1998
  • Many of steel structures having little internal damping consist of stiffened plates. In case that viscoelastic materials are adhered to the stiffened plates for the reduction of structure-borne noise, their effects are varied by the adhered position and dynamic characteristics of the structures as well as their material properties and adhered amount. In this paper, sound reduction effects of viscoelastic materials partially adhered to the different positions of a stiffened steel plate have been investigated by the measurement of vibratory velocity and sound intensity. The results show that optimal adherent positions of viscoelastic materials to reduce sound radiation power are the loop areas of modes.

  • PDF