References
- F. El Ghissassi, R. Baan, K. Straif, Y. Grosse, B. Secretan, V. Bouvard, L. Benbrahim-Tallaa, N. Guha, C. Freeman, L. Galichet, others, A review of human carcinogens - part D: radiation, Lancet Oncol. 10 (2009) 751-752. https://doi.org/10.1016/S1470-2045(09)70213-X
- I.A.E. Association, Others, Power Reactor Information System, 2015. Japan (Accessed January 2015).
- B.K. Sovacool, A critical evaluation of nuclear power and renewable electricity in Asia, J. Contemp. Asia 40 (2010) 369-400. https://doi.org/10.1080/00472331003798350
- D.C.W. Sanderson, J.M. Ferguson, The European capability for environmental airborne gamma ray spectrometry, Radiat. Protect. Dosim. 73 (1997) 213-218. https://doi.org/10.1093/oxfordjournals.rpd.a032137
- A. Hasegawa, T. Ohira, M. Maeda, S. Yasumura, K. Tanigawa, Emergency responses and health consequences after the Fukushima accident; evacuation and relocation, Clin. Oncol. 28 (2016) 237-244. https://doi.org/10.1016/j.clon.2016.01.002
- J.W. MacFarlane, O.D. Payton, A.C. Keatley, G.P.T. Scott, H. Pullin, R.A. Crane, M. Smilion, I. Popescu, V. Curlea, T.B. Scott, Lightweight aerial vehicles for monitoring, assessment and mapping of radiation anomalies, J. Environ. Radioact. 136 (2014) 127-130. https://doi.org/10.1016/j.jenvrad.2014.05.008
- M.F. L'Annunziata, Handbook of Radioactivity Analysis, Academic Press, 2012.
- G.F. Knoll, Radiation Detection and Measurement, John Wiley & Sons, 2010.
- S. Del Sordo, L. Abbene, E. Caroli, A.M. Mancini, A. Zappettini, P. Ubertini, Progress in the development of CdTe and CdZnTe semiconductor radiation detectors for astrophysical and medical applications, Sensors 9 (2009) 3491-3526. https://doi.org/10.3390/s90503491
- A.S. Novikov, S.E. Ulin, I. V Chernysheva, V. V Dmitrenko, V.M. Grachev, D. V Petrenko, A.E. Shustov, Z.M. Uteshev, K.F. Vlasik, Xenon detector with high energy resolution for gamma-ray line emission registration, in: Hard X-Ray, Gamma-Ray, Neutron Detect. Phys. XVI, 2014, p. 921318.
- S.V. Naydenov, V.D. Ryzhikov, Theoretical analysis of physical limits of energy resolution for detectors of scintillator-photodiode type and ways to improve their spectrometric characteristics, in: Hard X-Ray Gamma-Ray Detect. Phys. V, 2004, pp. 261-271.
- B.D. Milbrath, A.J. Peurrung, M. Bliss, W.J. Weber, Radiation detector materials: an overview, J. Mater. Res. 23 (2008) 2561-2581. https://doi.org/10.1557/JMR.2008.0319
- A.T. Lintereur, W. Qiu, J.C. Nino, J.E. Baciak, Iodine based compound semiconductors for room temperature gamma-ray spectroscopy, Opt. Photonics Glob. Homel. Secur. IV (2008) 694503.
- D. Pennicard, B. Pirard, O. Tolbanov, K. Iniewski, Semiconductor materials for x-ray detectors, MRS Bull. 42 (2017) 445-450. https://doi.org/10.1557/mrs.2017.95
- S.J. Bell, P. Aitken-Smith, S. Beeke, S.M. Collins, P.H. Regan, R. Shearman, A comparison of emerging gamma detector technologies for airborne radiation monitoring, J. Phys. Conf. Ser. (2016) 12010.
- A.E. Bolotnikov, S. Babalola, G.S. Camarda, Y. Cui, S.U. Egarievwe, R. Hawrami, A. Hossain, G. Yang, R.B. James, Te inclusions in CZT detectors: new method for correcting their adverse effects, IEEE Trans. Nucl. Sci. 57 (2010) 910-919. https://doi.org/10.1109/TNS.2010.2042617
- A.E. Bolotnikov, N.M. Abdul-Jabbar, S. Babalola, G.S. Camarda, Y. Cui, A. Hossain, E. Jackson, H. Jackson, J.R. James, A.L. Luryi, others, Optimization of virtual Frisch-grid CdZnTe detector designs for imaging and spectroscopy of gamma rays, in: hard X-Ray Gamma-Ray Detect, Phys IX (2007) 670603.
-
V.L.A. Kosyachenko, T. Aoki, C.P. Lambropoulos, V.A. Gnatyuk, E.V. Grushko, V.M. Sklyarchuk, O.L. Maslyanchuk, O.F. Sklyarchuk, A. Koike, High energy resolution CdTe Schottky diode $
${gamma}$ $-ray detectors, Nucl. Sci. Symp. Med. Imaging Conf. (NSS/MIC), 2012 (2012) 4156-4164. IEEE. - V. Gnatyuk, V. Sklyarchuk, T. Aoki, A. Koike, W. Pecharapa, Development of CdTe-based nuclear radiation sensors and related devices, AIP Conf. Proc. (2018) 20012.
- H. Haidar, F. Liu, H. Yuan, Calculation of scintillation properties of O1 "$times$ 1 "of the lanthanum bromide scintillation detector using MCNP simulation and experiment, J. Phys. Conf. Ser. (2018) 12063.
- S.N. Pyae, V.M. Grachev, V.V. Dmitrenko, S.E. Ulin, K.F. Vlasik, Z.M. Uteshev, A.E. Shustov, A.S. Novikov, D.V. Petrenko, I.V. Chernysheva, Xenon gammadetector applicability for identification and characterization of radioactive waste, Phys. Procedia. 74 (2015) 352-356. https://doi.org/10.1016/j.phpro.2015.09.191
- B. Ayaz-Maierhafer, T.A. DeVol, Determination of absolute detection efficiencies for detectors of interest in homeland security, Nucl. Instruments Methods Phys. Res. Sect. A Accel. Spectrometers, Detect. Assoc. Equip. 579 (2007) 410-413. https://doi.org/10.1016/j.nima.2007.04.143
- G.A. Kumar, I. Mazumdar, D.A. Gothe, Experimental measurements and GEANT4 simulations for a comparative study of efficiencies of LaBr3: Ce, NaI (Tl), and BaF2, Nucl. Instruments Methods Phys. Res. Sect. A Accel. Spectrometers, Detect. Assoc. Equip. 610 (2009) 522-529. https://doi.org/10.1016/j.nima.2009.08.075
- C.K. Eun, Y.B. Gianchandani, A wireless-enabled microdischarge-based radiation detector utilizing stacked electrode arrays for enhanced detection efficiency, J. Microelectromechanical Syst. 20 (2011) 636-643. https://doi.org/10.1109/JMEMS.2011.2127461
- E.R. Siciliano, J.H. Ely, R.T. Kouzes, B.D. Milbrath, J.E. Schweppe, D.C. Stromswold, Comparison of PVT and NaI (Tl) scintillators for vehicle portal monitor applications, Nucl. Instruments Methods Phys. Res. Sect. A Accel. Spectrometers, Detect. Assoc. Equip. 550 (2005) 647-674. https://doi.org/10.1016/j.nima.2005.05.056
-
A. Oberstedt, S. Oberstedt, R. Billnert, W. Geerts, F.-J. Hambsch, J. Karlsson, Identification of prompt fission $
${\gamma}$ $-rays with lanthanum-chloride scintillation detectors, Nucl. Instruments Methods Phys. Res. Sect. A Accel. Spectrometers, Detect. Assoc. Equip. 668 (2012) 14-20. https://doi.org/10.1016/j.nima.2011.11.088 - A. Oberstedt, R. Billnert, S. Oberstedt, Neutron measurements with lanthanum-bromide scintillation detectors: a first approach, Nucl. Instruments Methods Phys. Res. Sect. A Accel. Spectrometers, Detect. Assoc. Equip. 708 (2013) 7-14. https://doi.org/10.1016/j.nima.2013.01.005
- A. Zoglauer, M. Galloway, M. Amman, S.E. Boggs, J.S. Lee, P.N. Luke, L. Mihailescu, K. Vetter, C.B. Wunderer, First results of the high efficiency multi-mode imager (HEMI), in: Nucl. Sci. Symp. Conf. Rec. (NSS/MIC), 2009, IEEE, 2009, pp. 887-891.
- P.N. Luke, M. Amman, J.S. Lee, C.Q. Vu, Pocket-size CdZnTe gamma-ray spectrometer, IEEE Trans. Nucl. Sci. 52 (2005) 2041-2044. https://doi.org/10.1109/TNS.2005.856732
- M. Yousaf, T. Akyurek, S. Usman, A comparison of traditional and hybrid radiation detector dead-time models and detector behavior, Prog. Nucl. Energy 83 (2015) 177-185. https://doi.org/10.1016/j.pnucene.2015.03.018
- S. Usman, A. Patil, Radiation detector deadtime and pile up: a review of the status of science, Nucl. Eng. Technol. 50 (7) (2018) 1006-1016. https://doi.org/10.1016/j.net.2018.06.014
- R. Malhotra, Y.B. Gianchandani, A microdischarge-based neutron radiation detector utilizing a stacked arrangement of micromachined steel electrodes with gadolinium film for neutron conversion, IEEE Sensor. J. 15 (2015) 3863-3870. https://doi.org/10.1109/JSEN.2015.2397006
- A. Migdall, S.V. Polyakov, J. Fan, J.C. Bienfang, Single-photon Generation and Detection: Physics and Applications, Academic Press, 2013.
- N. Tsoulfanidis, Measurement and Detection of Radiation, CRC press, 2010.
- V.E. Kutny, A.V. Rybka, L.N. Davydov, A.O. Pudov, S.A. Sokolov, G.A. Kholomeyev, S.I. Melnikov, A.A. Turchin, Gamma-ray detector based on high pressure xenon for radiation and environmental safety, Probl. At. Sci. Technol. (2017) 103-108.
- F.G.A. Quarati, M.S. Alekhin, K.W. Kramer, P. Dorenbos, Co-doping of CeBr3 scintillator detectors for energy resolution enhancement, Nucl. Instruments Methods Phys. Res. Sect. A Accel. Spectrometers, Detect. Assoc. Equip. 735 (2014) 655-658. https://doi.org/10.1016/j.nima.2013.10.004
- M.S. Alekhin, D.A. Biner, K.W. Kramer, P. Dorenbos, Optical and scintillation properties of CsBa2I5: Eu2+, J. Lumin. 145 (2014) 723-728. https://doi.org/10.1016/j.jlumin.2013.08.058
- Z.T. Kang, R. Rosson, B. Barta, C. Han, J.H. Nadler, M. Dorn, B. Wagner, B. Kahn, GdBr3: Ce in glass matrix as nuclear spectroscopy detector, Radiat. Meas. 48 (2013) 7-11. https://doi.org/10.1016/j.radmeas.2012.11.010
- A.O. Pudov, A.S. Abyzov, S.A. Sokolov, L.N. Davydov, A.V. Rybka, V.E. Kutny, S.I. Melnikov, G.A. Kholomyeyev, S.A. Leonov, A.A. Turchin, Measurements and modeling of charge carrier lifetime in compressed xenon, Nucl. Instruments Methods Phys. Res. Sect. A Accel. Spectrometers, Detect. Assoc. Equip. 892 (2018) 98-105. https://doi.org/10.1016/j.nima.2018.03.001
- W. Chewpraditkul, K. Sreebunpeng, M. Nikl, J.A. Mares, K. Nejezchleb, A. Phunpueok, C. Wanarak, Comparison of Lu3Al5O12: Pr3+ and Bi4G-3O12 scintillators for gamma-ray detection, Radiat. Meas. 47 (2012) 1-5. https://doi.org/10.1016/j.radmeas.2011.08.023
- M. Grodzicka, M. Moszynski, T. Szczkesniak, M. Kapusta, M. Szawlowski, D. Wolski, Energy resolution of small scintillation detectors with SiPM light readout, J. Instrum. 8 (2013), P02017.
- T. Huang, Q. Fu, S. Lin, B. Wang, NaI (Tl) scintillator read out with SiPM array for gamma spectrometer, Nucl. Instruments Methods Phys. Res. Sect. A Accel. Spectrometers, Detect. Assoc. Equip. 851 (2017) 118-124. https://doi.org/10.1016/j.nima.2017.01.068
- T.J. Hajagos, C. Liu, N.J. Cherepy, Q. Pei, High-Z sensitized plastic scintillators: a review, Adv. Mater. (2018) 1706956. https://doi.org/10.1002/adma.201706956
- P. Wangyang, C. Gong, G. Rao, K. Hu, X. Wang, C. Yan, L. Dai, C. Wu, J. Xiong, Recent advances in halide perovskite photodetectors based on different dimensional materials, Adv. Opt. Mater. 6 (2018), 1701302. https://doi.org/10.1002/adom.201701302
- O. Nazarenko, S. Yakunin, V. Morad, I. Cherniukh, M. V Kovalenko, Single crystals of caesium formamidinium lead halide perovskites: solution growth and gamma dosimetry, NPG Asia Mater. 9 (2017) e373. https://doi.org/10.1038/am.2017.45
- T. Koike, S. Uno, T. Uchida, M. Sekimoto, T. Murakami, K. Miyama, M. Shoji, T. Fujiwara, E. Nakano, J. Chiba, A new gamma-ray detector with gold-plated gas electron multiplier, Nucl. Instruments Methods Phys. Res. Sect. A Accel. Spectrometers, Detect. Assoc. Equip. 648 (2011) 180-185. https://doi.org/10.1016/j.nima.2011.05.071
- G. Takoudis, S. Xanthos, A. Clouvas, M. Antonopoulos-Domis, C. Potiriadis, J. Silva, Spatial and spectral gamma-ray response of plastic scintillators used in portal radiation detectors; comparison of measurements and simulations, Nucl. Instruments Methods Phys. Res. Sect. A Accel. Spectrometers, Detect. Assoc. Equip. 599 (2009) 74-81. https://doi.org/10.1016/j.nima.2008.10.020
- S. Das, J. Saini, A.K. Dubey, Measurement of decay time constant of a plastic scintillator by a delayed coincidence method, DAE Symp. Nucl. Phys. (2015) 1068-1069.
- M. Nikl, A. Yoshikawa, Recent R&D trends in inorganic single-crystal scintillator materials for radiation detection, Adv. Opt. Mater. 3 (2015) 463-481. https://doi.org/10.1002/adom.201400571
- L. Stand, M. Zhuravleva, B. Chakoumakos, J. Johnson, A. Lindsey, C.L. Melcher, Scintillation properties of Eu 2+-doped KBa 2 I 5 and K 2 Bai 4, J. Lumin. 169 (2016) 301-307. https://doi.org/10.1016/j.jlumin.2015.09.013
- L. Stand, M. Zhuravleva, A. Lindsey, C.L. Melcher, Growth and characterization of potassium strontium iodide: a new high light yield scintillator with 2.4% energy resolution, Nucl. Instruments Methods Phys. Res. Sect. A Accel. Spectrometers, Detect. Assoc. Equip. 780 (2015) 40-44. https://doi.org/10.1016/j.nima.2015.01.052
- E.D. Bourret-Courchesne, G. Bizarri, R. Borade, Z. Yan, S.M. Hanrahan, G. Gundiah, A. Chaudhry, A. Canning, S.E. Derenzo, Eu2+-doped Ba2CsI5, a new high-performance scintillator, Nucl. Instruments Methods Phys. Res. Sect. A Accel. Spectrometers, Detect. Assoc. Equip. 612 (2009) 138-142. https://doi.org/10.1016/j.nima.2009.10.146
- M.S. Alekhin, S. Weber, K.W. Kramer, P. Dorenbos, Optical properties and defect structure of Sr2+ co-doped LaBr3: 5% Ce scintillation crystals, J. Lumin. 145 (2014) 518-524. https://doi.org/10.1016/j.jlumin.2013.08.019
- K.H. Kim, A.E. Bolotnikov, G.S. Camarda, R. Tappero, A. Hossain, Y. Cui, J. Franc, L. Marchini, A. Zappettini, P. Fochuk, others, New approaches for making large-volume and uniform CdZnTe and CdMnTe detectors, IEEE Trans. Nucl. Sci. 59 (2012) 1510-1515. https://doi.org/10.1109/TNS.2012.2202917
- C. Leak, W. Koehler, S. O'Neal, Z. He, K. Hitomi, Recent results from pixelated TlBr detectors with Tl electrodes operated at room-temperature, in: Nucl. Sci. Symp. Med. Imaging Conf. Room-Temperature Semicond. Detect. Work. (NSS/MIC/RTSD), 2016, 2016, pp. 1-3.
- M. Streicher, Y. Zhu, F. Zhang, Y.A. Boucher, C.G. Wahl, H. Yang, Z. He, A portable 2$times$ 2 digital 3D CZT imaging spectrometer system, in: Nucl. Sci. Symp. Med. Imaging Conf. (NSS/MIC), 2014, IEEE, 2014, pp. 1-3.
- S. Watanabe, T. Takahashi, Y. Okada, C. Sato, M. Kouda, T. Mitani, Y. Kobavashi, K. Nakazawa, Y. Kuroda, M. Onishi, CdTe stacked detectors for Gamma-ray detection, in: Nucl. Sci. Symp. Conf. Rec. 2001, IEEE, 2001, pp. 2434-2438.
- J. Saegusa, K. Kawasaki, A. Mihara, M. Ito, M. Yoshida, Determination of detection efficiency curves of HPGe detectors on radioactivity measurement of volume samples, Appl. Radiat. Isot. 61 (2004) 1383-1390. https://doi.org/10.1016/j.apradiso.2004.04.004
- Y. He, L. Matei, H.J. Jung, K.M. McCall, M. Chen, C.C. Stoumpos, Z. Liu, J.A. Peters, D.Y. Chung, B.W. Wessels, others, High spectral resolution of gamma-rays at room temperature by perovskite CsPbBr 3 single crystals, Nat. Commun. 9 (2018) 1609. https://doi.org/10.1038/s41467-018-04073-3
- M. Isaksson, C.L. Raaf, Environmental Radioactivity and Emergency Preparedness, CRC Press, 2017.
- F.G.A. Quarati, P. Dorenbos, J. der Biezen, A. Owens, M. Selle, L. Parthier, P. Schotanus, Scintillation and detection characteristics of high-sensitivity CeBr3 gamma-ray spectrometers, Nucl. Instruments Methods Phys. Res. Sect. A Accel. Spectrometers, Detect. Assoc. Equip. 729 (2013) 596-604. https://doi.org/10.1016/j.nima.2013.08.005
- H. Toivonen, Airborne gamma spectrometrydtowards integration of European operational capability, Radiat. Protect. Dosim. 109 (2004) 137-140. https://doi.org/10.1093/rpd/nch248
- D. Connor, P.G. Martin, T.B. Scott, Airborne radiation mapping: overview and application of current and future aerial systems, Int. J. Rem. Sens. 37 (2016) 5953-5987. https://doi.org/10.1080/01431161.2016.1252474
- K. Saito, Mapping and modelling of radionuclide distribution on the ground due to the Fukushima accident, Radiat. Protect. Dosim. 160 (2014).
- A.-J. Garcia-Sanchez, E.A. Garcia Angosto, P.A. Moreno Riquelme, A. Serna Berna, D. Ramos-Amores, Ionizing radiation measurement solution in a hospital environment, Sensors 18 (2018) 510.
- M.I. Kaniu, H.K. Angeyo, I.G. Darby, L.M. Muia, Rapid in-situ radiometric assessment of the Mrima-Kiruku high background radiation anomaly complex of Kenya, J. Environ. Radioact. 188 (2018) 47-57. https://doi.org/10.1016/j.jenvrad.2017.10.014
- I.P. Susila, A. Yuniarto, C. Cahyana, Monitoring and analysis of environmental gamma dose rate around serpong nuclear complex, At. Indones. 43 (2017) 87-92. https://doi.org/10.17146/aij.2017.681
- Y. Omori, H. Wakamatsu, A. Sorimachi, T. Ishikawa, Radiation survey on Fukushima Medical University premises about four years after the Fukushima nuclear disaster, Fukushima J. Med. Sci. 62 (2016) 1-17. https://doi.org/10.5387/fms.2015-16
- R.M. Vazquez, E. Gutierrez, Mobile robot for gamma radiation detection with long range remote control, Mechatronics, Electron. Automot. Eng. (ICMEAE), 2015 Int. Conf. (2015) 175-180.
- S. Kobayashi, T. Shinomiya, H. Kitamura, T. Ishikawa, H. Imaseki, M. Oikawa, S. Kodaira, N. Miyaushiro, Y. Takashima, Y. Uchihori, Radioactive contamination mapping of northeastern and eastern Japan by a car-borne survey system, Radi-Probe, J. Environ. Radioact. 139 (2015) 281-293. https://doi.org/10.1016/j.jenvrad.2014.07.026
- S. Syarbaini, B. Bunawas, I.P. Susila, Design and development of carborne survey equipment, At. Indones. 41 (2015) 97-102. https://doi.org/10.17146/aij.2015.383
- M. Andoh, Y. Nakahara, S. Tsuda, T. Yoshida, N. Matsuda, F. Takahashi, S. Mikami, N. Kinouchi, T. Sato, M. Tanigaki, others, Measurement of air dose rates over a wide area around the Fukushima Dai-ichi Nuclear Power Plant through a series of car-borne surveys, J. Environ. Radioact. 139 (2015) 266-280. https://doi.org/10.1016/j.jenvrad.2014.05.014
- M. Tanigaki, R. Okumura, K. Takamiya, N. Sato, H. Yoshino, H. Yamana, Development of a car-borne g-ray survey system, KURAMA, Nucl. Instruments Methods Phys. Res. Sect. A Accel. Spectrometers, Detect. Assoc. Equip. 726 (2013) 162-168. https://doi.org/10.1016/j.nima.2013.05.059
- A. Baeza, J.A. Corbacho, J. Miranda, Design and implementation of a mobile radiological emergency unit integrated in a radiation monitoring network, IEEE Trans. Nucl. Sci. 60 (2013) 1400-1407. https://doi.org/10.1109/TNS.2013.2245511
- Y. Ishigaki, Y. Matsumoto, R. Ichimiya, K. Tanaka, Development of mobile radiation monitoring system utilizing smartphone and its field tests in Fukushima, IEEE Sensor. J. 13 (2013) 3520-3526. https://doi.org/10.1109/JSEN.2013.2272734
- D. Williams, H. Bisby, The aerial survey of terrestrial radioactivity, Proc. IEE-Part B Electron. Commun. Eng. 108 (1961) 403-412. https://doi.org/10.1049/pi-b-2.1961.0068
- C. Nuccetelli, D.M. Castelluccio, E. Cisbani, S. Frullani, Experience at the istituto superiore di sanita on environmental research and monitoring with in-situ techniques, Situ Anal. Charact. Contam. Sites Using Nucl. Spectrom. Tech. (n.d.) 119.
- R.C. Runkle, L.E. Smith, A.J. Peurrung, The photon haystack and emerging radiation detection technology, J. Appl. Phys. 106 (2009) 7.
- S.D. Billings, B.R. Minty, G.N. Newsam, Deconvolution and spatial resolution of airborne gamma-ray surveys, Geophysics 68 (2003) 1257-1266. https://doi.org/10.1190/1.1598118
- D.M. Pfund, K.D. Jarman, B.D. Milbrath, S.D. Kiff, D.E. Sidor, Low count anomaly detection at large standoff distances, IEEE Trans. Nucl. Sci. 57 (2010) 309-316. https://doi.org/10.1109/TNS.2009.2035805
- M. Weinstein, A. Heifetz, R. Klann, Detection of nuclear sources in search survey using dynamic quantum clustering of gamma-ray spectral data, Eur. Phys. J. Plus. 129 (2014) 239. https://doi.org/10.1140/epjp/i2014-14239-3
- J.E. McLaughlin, H.L. Beck, Environmental radiation dosimetry for nuclear facilities and problems, IEEE Trans. Nucl. Sci. 20 (1973) 36-42. https://doi.org/10.1109/TNS.1973.4326883
- A.G. Darnley, The Relevance of Airborne and Ground Gamma Ray Spectrometry to Global Geochemical Baselines, Appl. Uranium Explor. Data Tech. Environ. Stud. IAEA-TECDOC-827, IAEA, Vienna, 1995, pp. 47-58.
- D.C.W. Sanderson, J.D. Allyson, A.N. Tyler, E.M. Scott, Environmental Applications of Airborne Gamma Spectrometry, 1995.
- I. Winkelmann, C. Strobl, M. Thomas, Aerial measurements of artificial radionuclides in Germany in case of a nuclear accident, J. Environ. Radioact. 72 (2004) 225-231. https://doi.org/10.1016/S0265-931X(03)00205-4
- Z.G. Burson, Airborne surveys of terrestrial gamma radiation in environmental research, IEEE Trans. Nucl. Sci. 21 (1974) 558-571. https://doi.org/10.1109/TNS.1974.4327515
- S. Okuyama, T. Torii, Y. Nawa, I. Kinoshita, A. Suzuki, M. Shibuya, N. Miyazaki, Development of a remote radiation monitoring system using unmanned helicopter, Int. Congr. Ser. (2005) 422-423.
- J. Towler, B. Krawiec, K. Kochersberger, Radiation mapping in post-disaster environments using an autonomous helicopter, Rem. Sens. 4 (2012) 1995-2015. https://doi.org/10.3390/rs4071995
- K. Kochersberger, K. Kroeger, B. Krawiec, E. Brewer, T. Weber, Post-disaster remote sensing and sampling via an autonomous helicopter, J. Field Robot. 31 (2014) 510-521. https://doi.org/10.1002/rob.21502
- G. Micconi, J. Aleotti, S. Caselli, G. Benassi, N. Zambelli, A. Zappettini, Haptic guided UAV for detection of radiation sources in outdoor environments, Res. Educ. Dev. Unmanned Aer. Syst. (RED-UAS), 2015 Work. (2015) 265-271.
- S. Dadon, A. Broide, M. Sheinfeld, Y. Kadmon, Y. Cohen, I. Halevy, Radioactive contamination estimation by airborne survey based NaI detectors, IEEE Trans. Nucl. Sci. 63 (2016) 630-633. https://doi.org/10.1109/TNS.2016.2514268
- Y. Sato, S. Ozawa, Y. Terasaka, M. Kaburagi, Y. Tanifuji, K. Kawabata, H.N. Miyamura, R. Izumi, T. Suzuki, T. Torii, Remote radiation imaging system using a compact gamma-ray imager mounted on a multicopter drone, J. Nucl. Sci. Technol. 55 (2018) 90-96. https://doi.org/10.1080/00223131.2017.1383211
- S. Mochizuki, J. Kataoka, L. Tagawa, Y. Iwamoto, H. Okochi, N. Katsumi, S. Kinno, M. Arimoto, T. Maruhashi, K. Fujieda, others, First demonstration of aerial gamma-ray imaging using drone for prompt radiation survey in Fukushima, J. Instrum. 12 (2017) P11014.
- Y. Shikaze, Y. Nishizawa, Y. Sanada, T. Torii, J. Jiang, K. Shimazoe, H. Takahashi, M. Yoshino, S. Ito, T. Endo, others, Field test around Fukushima Daiichi nuclear power plant site using improved Ce: Gd3 (Al, Ga) 5O12 scintillator Compton camera mounted on an unmanned helicopter, J. Nucl. Sci. Technol. 53 (2016) 1907-1918. https://doi.org/10.1080/00223131.2016.1185980
- Y. Sanada, T. Torii, Aerial radiation monitoring around the Fukushima Daiichi nuclear power plant using an unmanned helicopter, J. Environ. Radioact. 139 (2015) 294-299. https://doi.org/10.1016/j.jenvrad.2014.06.027
- P.G. Martin, O.D. Payton, J.S. Fardoulis, D.A. Richards, T.B. Scott, The use of unmanned aerial systems for the mapping of legacy uranium mines, J. Environ. Radioact. 143 (2015) 135-140. https://doi.org/10.1016/j.jenvrad.2015.02.004
- K. Boudergui, F. Carrel, T. Domenech, N. Guenard, J.-P. Poli, A. Ravet, V. Schoepff, R. Woo, Development of a drone equipped with optimized sensors for nuclear and radiological risk characterization, Adv. Nucl. Instrum. Meas. Methods Their Appl. (ANIMMA), 2011 2nd Int. Conf. (2011) 1-9.
- R. Pollanen, H. Toivonen, K. Perajarvi, T. Karhunen, T. Ilander, J. Lehtinen, K. Rintala, T. Katajainen, J. Niemela, M. Juusela, Radiation surveillance using an unmanned aerial vehicle, Appl. Radiat. Isot. 67 (2009) 340-344. https://doi.org/10.1016/j.apradiso.2008.10.008
- S. Okuyama, T. Torii, A. Suzuki, M. Shibuya, N. Miyazaki, A remote radiation monitoring system using an autonomous unmanned helicopter for nuclear emergencies, J. Nucl. Sci. Technol. 45 (2008) 414-416. https://doi.org/10.1080/00223131.2008.10875877
- R.L. Grasty, B.R.S. Minty, A Guide to the Techncial Specifications for Airborne Gamma-Ray Surveys, Citeseer, 1990.
- M. Alamaniotis, J. Mattingly, L.H. Tsoukalas, Kernel-based machine learning for background estimation of NaI low-count gamma-ray spectra, IEEE Trans. Nucl. Sci. 60 (2013) 2209-2221. https://doi.org/10.1109/TNS.2013.2260868
- T. Smith, S. Cao, K.J. Kearfott, Temporal fluctuations in indoor background gamma radiation using NaI (Tl), Health Phys. 114 (2018) 360-372. https://doi.org/10.1097/HP.0000000000000813
- K. Kumagai, H. Ookubo, H. Kimura, Discrimination between natural and other gamma ray sources from environmental gamma ray dose rate monitoring data, Radiat. Protect. Dosim. 167 (2015) 293-297. https://doi.org/10.1093/rpd/ncv265
- K.A.P. Kumar, G.A.S. Sundaram, R. Thiruvengadathan, Advances in detection algorithms for radiation monitoring, J. Environ. Radioact. 217 (2020), 106216. https://doi.org/10.1016/j.jenvrad.2020.106216
- E.Z. Sombrito, M.C. Tangonan, A.D. Bulos, Detector Efficiency and Energy Calibration of the CRD HPGe Gamma Spectrometer System, 1989.
- J. Rajendran, G.A.S. Sundaram, Design and evaluation of printed log periodic dipole antenna for an L band electrically steerable array system, Comput. Syst. Commun. (ICCSC), 2014 First Int. Conf. (2014) 311-316.
- M. Kort, Weapons of Mass Destruction, Infobase Publishing, 2010.
- M.J Berger, J.H. Hubbell, S.M. Seltzer, J. Chang, J.S. Coursey, R. Sukumar, D.S. Zucker, K. Olsen, XCOM: photon cross section database, National Institute of Standards and Technology, Gaithersburg, Gaithersburg, MD. (2005). http://physics.nist.gov/xcom.
Cited by
- State-of-the-Art Mobile Radiation Detection Systems for Different Scenarios vol.21, pp.4, 2020, https://doi.org/10.3390/s21041051
- A High Seebeck Voltage Thermoelectric Module with P‐type and N‐type MAPbI 3 Perovskite Single Crystals vol.7, pp.3, 2020, https://doi.org/10.1002/aelm.202001003
- Detectors and Cultural Heritage: The INFN-CHNet Experience vol.11, pp.8, 2020, https://doi.org/10.3390/app11083462
- Gamma radiation attenuation characteristics of polyimide composite with WO2 vol.137, 2020, https://doi.org/10.1016/j.pnucene.2021.103795
- Localizing hot spots in Poisson radiation data matrices: nonnegative tensor factorization and phase congruency vol.8, pp.1, 2020, https://doi.org/10.1186/s40537-021-00510-1