• Title/Summary/Keyword: purification method

Search Result 848, Processing Time 0.028 seconds

A Simple Purification Method and Chemical Properties of Potphyran from Porphyra yezoensis (Porphyran의 신속한 정제 방법 및 화학적 특성)

  • Park, Jin-Hee;Koo, Jae-Geun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.41 no.6
    • /
    • pp.409-413
    • /
    • 2008
  • A simple method for the purification of porphyran from laver Porphyra yezoensis was developed to obtain information for the development of food materials with biological functionality. Crude porphyran (CP) was extracted from dried laver in boiling water for 3 h, and then fractionated using cetylpyridinium chloride into an acidic fraction (CP-F1) and a neutral fraction (CP-F2). CP-F1 was fractionated further by fractional ethanol precipitation. Fraction CP-F1-70, precipitated at an ethanol concentration of 61-70% was the major fraction containing 68.1% of the yield from the initial fraction CP-F1. The CP-F1-70 fraction displayed a single band on Sepharose CL-4B with a molecular mass of 550 kDa, indicating a homogeneous polysaccharide. The molar ratio of galactose, 3,6-anhydro-L-galactose, 6-0-methyl-D-galactose and ester sulfate of CP-F1-70 was 1:0.32:0.07:0.53. This method is very useful for rapid and large-scale preparation of purified porphyran because it is compatible with mass production.

Study on Micro-bubble Generation Characteristics in Venturi Cavitation using Laser Diffractometer (레이저 회절 측정기를 이용한 벤츄리 캐비테이션에서의 마이크로버블 발생 특성 연구)

  • Lim, Yun Gyu;Yang, Hae Jeong;Kim, Yung Il
    • Journal of Drive and Control
    • /
    • v.16 no.1
    • /
    • pp.1-6
    • /
    • 2019
  • The use of micro bubbles in industrial fields has been increasing in the recent years., particularly micro-bubble sterilization and water purification effects. Various methods have been developed for the generation of micro-bubbles. Depending on the method of generating bubbles, the micro-bubbles can be roughly classified into saturation molding, cavitation and rotation flow types. The objective of this study was to use ventilated tube type as a method of generating micro-bubbles in order to purify large amount of water quality such as lakes and reservoirs. This method shows a difference in efficiency in which micro-bubbles are generated depending on the contact ratio of gas to liquid. The study also investigated the optimal gas liquid contact ratio by applying various orifice methods and investigated the optimum condition of micro-bubble generation by gas Based on this, a technology to develop a micro-bubble generator with a venturi type nozzle shape that has a high water purification effect was developed.

Purification of Diphtheia Toxin and the Production of Detoxificated Toxoid Vaccine (디프테리아 toxin 정제와 무독화 toxoid 백신 생산)

  • Cho, Min;Ryu, Yeon-Woo
    • KSBB Journal
    • /
    • v.14 no.2
    • /
    • pp.248-254
    • /
    • 1999
  • Adverse reactions after injection of diphtheria vaccine are induced by impurities present in crude toxoids that cannot be removed completely by purification of toxoids after formalization. To increase toxoid purity, toxin purification was tried before formalization. Crude toxin was purified with ultrafiltration and ion-exchange chromatography. Purified toxin purity was improved 2.9 times higher than crude toxin, and purity was 2,560 Lf/mg PN. Purified toxin was detoxified with formalin and lysine, and potency test were performed. Toxoid, prepared from toxin treated with formalin and lysine, did not show reversion to toxin and purity was higher than the toxoid purified after formalization. Therefore, we concluded that the use of toxoid vaccine prepared from toxin purified is a useful method of minimize adverse reaction after injection of diphtheria vaccine.

  • PDF

Analysis of Water Purification Capability of the Spent Fuel Storage Pool Using Consolidated Fuel Storage in Uljin 1&2 (조밀화 핵연료 집합체 저장에 의한 울진 1&2호기의 사용후 핵연료 저장조 정화능력 해석)

  • Lim, Chae-Joon;Park, Goon-Cherl;Chung, Chang-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.22 no.2
    • /
    • pp.83-94
    • /
    • 1990
  • The radioactivity in the spent fuel storage pool is calculated to ensure to maintain its concentration below the permissible limit, when the storage capacity of Uljin nuclear power plant unit 1&2 is extended from 9/3 to 32/3 core using consolidated fuels in maximum density rack (MDR). For this evalulation, two models to calculate the spent fuel pool activities on the continuous and intermittent operating its purification system are developed and these results compared, The results of above two cases show that the current water purification system can not guarantee the radioactivity concentration below the design limit, 5$\times$10$^{-4}$ $\mu$Ci/ml, for the extention to 32/3 core. Therefore, it has been concluded that a modification of the current purification system is necessary to extend the spent fuel storage capacity with the above method. The alternative way suggested in this study is to increase the number of cation bed demineralizers.

  • PDF

Effect of Heat Treatment Environment on the Densification of Cold Sprayed Ti Coating Layer (저온 분사 공정으로 제조된 티타늄 코팅층의 치밀화에 미치는 열처리 분위기의 영향)

  • Yu, Ji-Sang;Kim, Hyung-Jun;Oh, Ik-Hyun;Lee, Kee-Ahn
    • Journal of Powder Materials
    • /
    • v.19 no.2
    • /
    • pp.110-116
    • /
    • 2012
  • This study investigated the effects of annealing environment for the densification and purification properties of pure titanium coating layer manufactured by cold spraying. The annealing was conducted at $600^{\circ}C$/1 h and three kinds of environments of vacuum, Ar gas, and $5%H_2+Ar$ mixture gas were controlled. Cold sprayed Ti coating layer (as sprayed) represented 6.7% of porosity and 228 HV of hardness, showing elongated particle shapes (severe plastic deformation) perpendicular to injection direction. Regardless of gas environments, all thermally heat treated coating layers consisted of pure ${\alpha}$-Ti and minimal oxide. Vacuum environment during heat treatment represented superior densification properties (3.8% porosity, 156.7 HV) to those of Ar gas (5.3%, 144.5 HV) and $5%H_2+Ar$ mixture gas (5.5%, 153.1 HV). From the results of phase analysis (XRD, EPMA, SEM, EDS), it was found that the vacuum environment during heat treatment could be effective for reducing oxide contents (purification) in the Ti coating layer. The characteristic of microstructural evolution with heat treatment was found to be different at three different gas environments. The controlling method for improving densification and purification in the cold sprayed Ti coating material was also discussed.

Preparation of High-Purity Urokinase Using Single-Step Hydrophobic Interaction Chromatography with p-Aminobenzamidine Ligand

  • Cao, Xue-Jun;Zhou, Jian-Hua;Huang, Zhen-Hui;Wu, Xing-Yan;Hur, Byung-Ki
    • Journal of Microbiology and Biotechnology
    • /
    • v.12 no.2
    • /
    • pp.196-203
    • /
    • 2002
  • A novel process for urokinase purification was studied using p-aminobenzamidine as the ligand and sepharose 4B as the matrix. The adsorption, washing, and elution conditions were optimized by an unusual method. An adsorption buffer containing 2.5 M NaCl and $1\%$ Tween 80 facilitated the adsorption of urokinase on the affinity media and prevented contaminants from binding to the p-aminobenzamidine affinity gel. It was found that $5\%$ Tween 80 removed most of the contaminants from the affinity column. A 0.2 M glycine elution buffer containing 0.5 M NaCl (pH 3.0) was found to have a strong elution ability with a high recovery and purity of urokinase. A crude urokinase material of231 IU/mg protein from human urine was purified to 124,300 IU/mg protein with a purification factor of 538 and yield of $86.7\%$. As a result, a high purity urokinase was obtained with only a single affinity chromatography step. The purification process was successfully scaled-up to a 2-1 chromatography column. The resulting urokinase eluate could be directly lyophilized, thereby complying with Chinese pharmacopoeia (1995 version) standards.

Optimization of Adsorbent Treatment Process for the Purification of Paclitaxel from Plant Cell Cultures of Taxus chinensis (주목 식물세포(Taxus chinensis)배양으로부터 파클리탁셀 정제를 위한 흡착제 처리 공정 최적화)

  • Lee, Chung-Gi;Kim, Jin-Hyun
    • Korean Chemical Engineering Research
    • /
    • v.52 no.4
    • /
    • pp.497-502
    • /
    • 2014
  • Biomass-derived tar and waxy compounds have a highly negative effect on the separation and purification of paclitaxel and should be removed prior to final purification. Adsorbent treatment is a simple, efficient method for removal of tar and waxy compounds from plant cell cultures. In this study, we optimized the important process parameters (adsorption temperature, time, solvent type and adsorbent amount) of adsorbent treatment with Sylopute to remove the tar and waxy compounds in a pre-purification step. The optimal adsorption temperature, adsorption time, solvent type, and crude extract/Sylopute ratio were $30^{\circ}C$, 15 min, methylene chloride, and 1:1(w/w), respectively. This result could be confirmed by HPLC analysis of the absorbent after treatment and TGA of the organic substances that were bound to the adsorbent. In adsorbent treatment step, the purity seemed to show a small improvement but this treatment had a significant effect on convenience and feasibility of following steps by the removal of tar and waxy compounds.

A Customized Cleaning Agent for the Maintenance of Electric Fume Collector Used for the Purification of Effluent Gas from the Textile Industry (섬유산업 배기가스 정화용 Electric Fume Collector 설비의 유지보수를 위한 맞춤형 세정제)

  • Kim, Hotae;Yoo, Hwang-Yooll;Jeon, Koung Min;Song, Doori;Kim, Jin-Bae
    • Applied Chemistry for Engineering
    • /
    • v.29 no.2
    • /
    • pp.229-236
    • /
    • 2018
  • A customized cleaning agent was investigated for improving the performance decreased by the pollution of collecting plates in an electric fume collector (EFC) which was developed and applied for the purification of effluent gas including oil mist from the textile industry. The pollutants on the surface of collecting plates were blackened by the condensation of oil mist for a long time and difficult to remove by general cleaning agents. The composition of an optimized cleaning agent consisted of alkali, alcohol, glycol and non-ionic surfactant sources was determined by considering the pollutant properties and effect on the damage of the basic metal of collecting plate and so on. The developed cleaning agent solution diluted by 9.1% was applied to the field test, and also the pollutants strongly adhered on collecting plate surfaces were successfully removed by a simple spraying method. The effluent gas purification efficiency of EFC increased significantly by cleaning of collecting plates.

A Study on the Safety Improvement of PSA System for Hydrogen Separation and Purification (수소분리 및 정제를 위한 PSA(Pressure Swing Adsorption)시스템 안전성향상에 관한 연구)

  • Oh, Sang-Gyu;Lee, Seul-Gi;Lee, Jun-Seo;Ma, Byung-Chol
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.1
    • /
    • pp.7-19
    • /
    • 2022
  • Hydrogen purification is generally performed through chemical and physical methods. Among various types of purification method PSA(Pressure Swing Adsorption) is widely used with its purification capacity and economic efficiency. In Korea, most of the hydrogen used in automobiles and power generation fuel cells is purified using PSA. Hydrogen produced in petrochemical complexes has difficulties in transportation. The government is planning to install hydrogen extractors that produce hydrogen directly from consumers in connection with the city gas supply chain, and companies are also installing related research and demonstration facilities one after another. Europe and others have recently established safety standards related to PSA and are making efforts for systematic safety management at the construction and operation stage, but domestic safety standards related to PSA are still insufficient. This study aims to identify problems of existing facilities through surveys and risk assessment by companies operating existing PSA, and to prepare domestic technical standards including them in overseas technical standards to promote the safety of new and existing PSA systems.

Avantor® ACE® Wide Pore HPLC Columns for the Separation and Purification of Proteins in Biopharmaceuticals (바이오의약품의 단백질 분리 및 정제를 위한 Avantor® ACE® 와이드 포어 HPLC 컬럼 가이드)

  • Matt James;Mark Fever;Tony Edge
    • FOCUS: LIFE SCIENCE
    • /
    • no.1
    • /
    • pp.3.1-3.7
    • /
    • 2024
  • The article discusses the critical role of chromatography in the analysis and purification of proteins in biopharmaceuticals, emphasizing the importance of comprehensive characterization for ensuring their safety and efficacy. It highlights the use of Avantor® ACE® HPLC columns for the separation and purification of proteins, focusing on the analysis of intact proteins using reversed-phase liquid chromatography (RPLC) with fully porous particles. This article also details the application of different mobile phase additives, such as TFA and formic acid, and emphasizes the advantages of using type B ultra-pure silica-based columns for efficiency and peak shape in biomolecule analysis. Additionally, it addresses the challenges of analyzing intact proteins due to slow molecular diffusion and introduces the concept of solid-core (or superficially porous) particles, emphasizing their benefits over traditional porous particles for the analysis of therapeutic proteins. Furthermore, it discusses the development of Avantor® ACE® UltraCore BIO columns, specifically designed for the high-efficiency separation of large biomolecules, such as proteins, and demonstrates their effectiveness in achieving high-resolution separations, even for higher molecular weight proteins like monoclonal antibodies (mAbs). In addition, it underscores the complexity of analyzing and characterizing intact protein biopharmaceuticals, requiring a range of analytical techniques and the use of wide-pore stationary phases, operated at elevated temperatures and with relatively shallow gradients. It highlights the comprehensive range of options offered by Avantor® ACE® wide pore columns, including both fully porous and solid-core particles, bonded with a variety of complementary stationary phase chemistries to optimize selectivity during method development. The use of ultrapure and highly inert base silica is emphasized for enabling the use of lower concentrations of mobile phase modifiers without compromising analyte peak shape, particularly beneficial for LC-MS applications. Then the article concludes by emphasizing the significance of reversed-phase liquid chromatography and its compatibility with mass spectrometry as a valuable tool for the separation and analysis of intact proteins and their closely related variants in biopharmaceuticals.

  • PDF