Analysis of Water Purification Capability of the Spent Fuel Storage Pool Using Consolidated Fuel Storage in Uljin 1&2

조밀화 핵연료 집합체 저장에 의한 울진 1&2호기의 사용후 핵연료 저장조 정화능력 해석

  • Published : 1990.06.01

Abstract

The radioactivity in the spent fuel storage pool is calculated to ensure to maintain its concentration below the permissible limit, when the storage capacity of Uljin nuclear power plant unit 1&2 is extended from 9/3 to 32/3 core using consolidated fuels in maximum density rack (MDR). For this evalulation, two models to calculate the spent fuel pool activities on the continuous and intermittent operating its purification system are developed and these results compared, The results of above two cases show that the current water purification system can not guarantee the radioactivity concentration below the design limit, 5$\times$10$^{-4}$ $\mu$Ci/ml, for the extention to 32/3 core. Therefore, it has been concluded that a modification of the current purification system is necessary to extend the spent fuel storage capacity with the above method. The alternative way suggested in this study is to increase the number of cation bed demineralizers.

울진 1&2호기의 사용후 핵연료 중간저장을 위한 기존 저장조용량확장 방안으로서 maximum density rack (MDR)에 consolidated fuel을 저 장하여 현 9/3 노심에서 32/3으로 확장할 경우 방사능 농도가 적정기준 이하로 유지될 수 있는지 여부를 분석하였다. 이를 위해 본 연구에서는 정화계통의 연속적 운전방식과 주기적 운전방식에 대한 저장용수중의 방사능 농도계산을 위한 두 가지 계산 모델을 만들어 상호비교 하였다. 이 결과 두 경우 모두 32/3 노심저장에 대하여 기존 정화계통으로는 기준치인 5$\times$1-$^{-4}$ $\mu$Ci/ml이하로 유지시킬 수 없었다. 따라서 기존의 시설변경이 불가피하며 그 방안으로 사용후 핵연료 저장조에서의 양이온 탈염기 수를 증가시키는 방법이 타당한 것으로 나타났다.

Keywords