  • The reduction of $CO_2$ emissions has been a key target in the Marine Industry since the IMO's Marine Environment Protection Committee published its findings in 2009. The representative emission index is termed as the EEDI (Energy Efficiency Design Index) for the new ships. Among various flow control techniques ever proposed, the air lubrication method is the one of most promising one in terms of practical applicability. The present study examines the basic characteristics of the flat plate test with intention of applying the air lubrication technology to the reduction of the resistance of a ship. Image analysis technique is proposed as a tool to quantify the effectiveness of the air lubrication method.

경년열화에 의한 소형 환풍기의 전기화재에 관한 연구 (A Study on Electrical Fire of Small Ventilators due to Aged Degradation)

  • 임종룡;이성일
    • 한국안전학회지
    • /
    • 제31권4호
    • /
    • pp.22-26
    • /
    • 2016
  • "Always-on" small ventilators are likely to experience thermal decomposition of insulating material due to thermal, electrical, mechanical and environmental influences, and lose insulating properties by the process of oxidation and physiochemical reaction. This increases the risk of electrical fire because of layer short, short circuit, overload and Plastics are usually used to make ventilator and ventilator enclosures since they make less noise and are cheaper. Although more preferred than iron, plastic, a combustible material, has a higher risk of fire. In this study, several experiments were carried out to find out how RCD(Residual Current Protective Device) and Thermal fuses, which are electric motor protection devices, work and what needs to be done to reduce the risk of fire.

Challenge to Future Displays: Transparent AM-OLED driven by PEALD grown ZnO TFT

  • Ko Park, Sang-Hee;Hwang, Chi-Sun;Byun, Chun-Won;Ryu, Min-Ki;Lee, Jeong-Ik;Chu, Hye-Yong;Cho, Kyoung-Ik;Chae, Jang-Youl;Han, Se-Jin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권2호
    • /
    • pp.1249-1252
    • /
    • 2007
  • We have fabricated 3.5” transparent AM-OLED panel driven by PEALD grown ZnO TFT. The performance of ZnO thin film transistor was improved by adapting top gate structure, protection layer for ZnO from photolithography process, optimizing temperature and plasma power of ZnO growth process. The ZnO-TFT has a mobility of $8.9cm^2/V.s$, a subthreshold swing of 0.95V, and an on/off ratio of $10^7$.

  • PDF

The Active Dissolved Wafer Process (ADWP) for Integrating single Crystal Si MEMS with CMOS Circuits

  • Karl J. Ma;Yogesh B. Glanchandani;Khalil Najafi
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제2권4호
    • /
    • pp.273-279
    • /
    • 2002
  • This paper presents a fabrication technology for the integration of single crystal Si microstructures with on-chip circuitry. It is a dissolved wafer technique that combines an electro-chemical etch-stop for the protection of circuitry with an impurity-based etch-stop for the microstructures, both of which are defined in an n-epi layer on a p-type Si wafer. A CMOS op. amp. has been integrated with $p^{++}$ Si accelerometers using this process. It has a gain of 68 dB and an output swing within 0.2 V of its power supplies, unaffected by the wafer dissolution. The accelerometers have $3{\;}\mu\textrm{m}$ thick suspension beams and $15{\;}\mu\textrm{m}$ thick proof masses. The structural and electrical integrity of the fabricated devices demonstrates the success of the fabrication process. A variety of lead transfer methods are shown, and process details are discussed.

Fe-Scale과의 반응에 의한 $Cr_3C_2$계 복합체의 산화손상 (Oxidation of $Cr_3C_2$ Composites with Fe-Scale)

  • 한동빈;홍기곤;박병학
    • 한국세라믹학회지
    • /
    • 제31권7호
    • /
    • pp.767-771
    • /
    • 1994
  • In a salb-preheating furnace of steel-making industry, the oxidation/degradation behavior of Cr3C2 ceramic composited dkid button reaction with scale in Fe-oxide system occurs and was thermodynamically examined. The reaction of scale with Cr3C2 skid button produces Cr3C2(s) and C(s), and Co gas is then evolved from the reaction of C(s) with Fe-scale. Cr3C2(s) from oxidation of Cr3C2(s) reacted with Fe-oxide(s) becomes high-melting chromite. The chromite acts as protection layer against further oxidation and improves resistance of the reaction of Cr3C2 skid button with Fe-scale.

  • PDF

Improved flame retardant performance of cellulose fibers following fluorine gas treatment

  • Kim, Jong Gu;Lee, Young-Seak;In, Se Jin
    • Carbon letters
    • /
    • 제28권
    • /
    • pp.66-71
    • /
    • 2018
  • To improve the flame retardant performance of cellulose fibers, fluorine functional groups were introduced under various controlled fluorination conditions. The properties of the fluorinated cellulose fibers were analyzed by X-ray photoelectron spectroscopy and a thermogravimetric analysis. The fluorine functional group content in the fluorinated cellulose fibers increased with an increase in the fluorination temperature. However, the fluorination reaction increased the char yield and decreased the rate of degradation of the cellulose fibers by introducing donors, enabling the formation of a thick and compact char layer. Therefore, the flame retardant properties of cellulose fibers were improved following the fluorination treatment.

Potential applications of radioprotective phytochemicals from marine algae

  • Oh, Jae-Young;Fernando, I.P. Shanura;Jeon, You-Jin
    • ALGAE
    • /
    • 제31권4호
    • /
    • pp.403-414
    • /
    • 2016
  • The use of ionizing radiation and radioactive elements is becoming increasingly popular with the rapid developments in nuclear technology, radiotherapy, and radio diagnostic methods. However, ionizing radiation can directly or indirectly cause life-threatening complications such as cancer, radiation burns, and impaired immunity. Environmental contamination with radioactive elements and the depletion of ozone layer also contribute to the increased levels of radiation exposure. Radioprotective natural products have particularly received attention for their potential usefulness in counteracting radiation-induced damage because of their reduced toxicity compared with most drugs currently in use. Moreover, radioprotective substances are used as ingredients in cosmetic formulations in order to provide protection against ultraviolet radiation. Over the past few decades, the exploration of marine algae has revealed the presence of radioprotective phytochemicals, such as phlorotannins, polysaccharides, carotenoids and other compounds. With their promising radioprotective effects, marine algae could be a future source for discovering potential radioprotective substances for development as useful in therapeutics.

건축화재시 피난대책에 관한 연구 -고층건물의 제연을 중심으로- (A Study on the Smoke Proof Measure of High Rise Buildings.)

  • 이영재;이근영
    • 한국화재소방학회논문지
    • /
    • 제4권1호
    • /
    • pp.3-12
    • /
    • 1990
  • This study is to Present the air Pressurization system of staircase as a way to decrease the injury of human life which is suffocated by smoke when the fire break out in building. 1) The best among an air pressurization system of stairshaft Is multiple air Injection system established to be situated an air injection point in each layer. 2) If the air pressurization system is also applied to the elevator accessory room to use commonly, it can prevent from the smoke spreading and pollution inside building caused by stack effect of elevator shaft. 3) For the reasonable and safe escape and air pressurization system must be carried out from the project of basic shape of building under the close cooperation with architect and fire protection expert.

  • PDF

산업부산물을 활용한 비구조용 콘크리트의 건조수축 특성에 관한 실험적 연구 (An Experimental Study on the Non-Structural Lean Concrete's Dry Shrinkage with industrial by-product)

  • 황무연;양완희;박동철;김우재
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.216-217
    • /
    • 2017
  • Slag cement or ternary blended cement is mainly used for non-structural lean concrete for the purpose of foundation work or protection of the waterproof layer on the roof of buildings. However, such non-structural lean concrete has a lot of drying shrinkage cracks, which makes it difficult to maintain the quality of the structure. Therefore, in this study, the compressive strength and the drying shrinkage of ternary blended cement(blended of portland cement, blast furnace slag, fly ash from combined heat and power Plant) for non-structural lean concrete were examined. As a result, it was confirmed that this non-structural lean concrete reduced drying shrinkage compared to the conventional ternary blended cement using fly ash from power plant.

  • PDF

ECC로 피복된 고강도콘크리트의 폭렬저감 및 열적특성에 관한 실험적 연구 (Fire Resistant Performance of Anti-Spalling ECC Layers in High-Strength Concrete Structures)

  • 이재영;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 춘계 학술논문 발표대회
    • /
    • pp.199-202
    • /
    • 2008
  • The purpose of this study is to obtain the fundamental fire resistance performance of engineered cementitious composites(ECC) under fire temperature in order to use the fire protection material in high-strength concrete structures. The present study conducted the experiment to simulate fire temperature by employing of ECC and investigated experimentally the explosion and cracks in heated surface of these ECC. In the experimental studies, 3 HSC specimens are being exposed to fire, in order to examine the influence of various parameters(such as depth of layer=20, 30, 40mm; construction method=lining type) on the fire performance of HSC structures. Employed temperature curve were ISO 834 criterion(3hr), which are severe in various criterion of fire temperature in building structures. The numerical regressive analysis and proposed equation to calculate ambient temperature distribution is carried out and verified against the experimental data. By the use of proposed equation, the HSC members subjected to fire loads were designed and discussed.

  • PDF