• Title/Summary/Keyword: process measurement

Search Result 5,167, Processing Time 0.044 seconds

A Study on the Development of the measurement system of the Power steering unit for Automobile (자동차용 Poewer steering unit 의 자동측정시스템 개발에 관한 연구)

  • 기창두;김상묵
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.925-928
    • /
    • 1995
  • Recently, the system of the industry demands quick and accurate measurement for the mass production and high quality. Also, we need to improve the accuracy to decrease the failure rate in automatic assembly processing and improve the confidence, durability and the compatibility of parts. To answer this tendency and requirement, we have developed many accrate measuring instruments and methods. In this paper, we develop the whidows program using the DSP board(TMS320C25) which is used the data acquisition and the Visual C $^{++}$ , a windows programming language. We perform the measurement, analysis and output process in GUI(Graphic User Interface)environment. By using system, we will save the time required for the hand-worked measurement and avoid the useless iterative measurement. Furthermore, we expect to improve the productivity through automotive quality control in manufacturing process.s.

  • PDF

On the Development of In-process Measurement System for Guidance Core Diameter (유도심경의 인프로세스 측정시스템 개발)

  • 김정두
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.03a
    • /
    • pp.190-195
    • /
    • 1998
  • The guidance core is a principal part installed between the ink and the pen nib for the function of supplying ink to paper with reqularity. The current measurement of this product, Guidance core, in service is done by on operator with a micrometer, which could result in the decrease of productivity and working efficiency as well as causing errors. In this study, the existing measurement of the dialmeter of the Guidance core in the centerless grinding process is changed to the inprocessor measurement which enables consecutive measurement during the production of the Guidance core, and this system is also developed to work properly under bad circumstances and to have superior reliance and operational efficiency.

  • PDF

A Study on the Measurement Method and Uncertainty Factors for Precision Inspection to Feed Unit of High Precision Machine Tool (고정밀 공작기계 이송장치의 정밀도 측정방법 및 불확도 요인에 관한 연구)

  • Kim, Sang-Hwa;Kim, Byung-Ha;Choi, Woo-Gak
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.4
    • /
    • pp.55-61
    • /
    • 2012
  • Very important content in performance evaluation of machine tool is positioning accuracy and repeatability precision measurements of feed mechanism. A study analyses the measurement method and uncertainty factors by ISO-based test method. Reliable results can't be derived without the notion of measurement uncertainty. The reason is that the measured value includes a lot of uncertain factors. Finding the factor that affects the measurement of parameter is important for estimation of measurement precision. In this paper, the evaluation of uncertainty analysis about positioning accuracy and repeatability precision measurements of high precision feed mechanism is presented to evaluate the important factors of uncertainty.

Three Dimensional Measurements and Parameter Identification of Force and Torque Distmbances of High Speed Rotating Actuators (고속회전구동기의 힘 및 토크 외란 3차원 측정과 파라미터 추정)

  • Lee, Hyun-Ho;Oh, Hwa-Suk;Cheon, Dong-Ik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.4
    • /
    • pp.409-416
    • /
    • 2007
  • A momentum type actuator produces force and torque disturbances as well as its designed control torque. These disturbances are ones of the largest disturbance sources inside the spacecraft, which deteriorate the pointing stability of the high precision spacecraft. The measurement and analysis of actuator disturbances are therefore imperative for such a spacecraft, and thus a three dimensional torque measurement table has been developed for that purpose. The data acquired from the measurement table are processed in the frequency domain and displayed in the power spectral density(PSD). Through this process, disturbance model parameters are obtained and used for the attitude stability simulation. The process has been adopted for the disturbance measurement of the reaction wheel, and the validity of measurements and parameter identification procedure is verified.

Development of Performance Measurement Model for B2B e- Marketplace using BSC (BSC를 이용한 B2B e-Marketplace 성과평가 모형 개발)

  • 박철수
    • Journal of the Korea Safety Management & Science
    • /
    • v.5 no.4
    • /
    • pp.229-243
    • /
    • 2003
  • This paper suggests the process of performance measurement system development for B2B e-Marketplace using BSC (Balanced Scorecard). As the first step, main features and factors affecting performance of e-Business company and especially of B2B e-Marketplaces were derived based on the literatures. For the 2nd step, the nonnative performance measurement model for B2B e-Marketplace was suggested. Especially, the research range that the model covers is restricted to the neutral and systematic sourcing B2B e-Marketplace. And, the performance measurement model was based on BSC, for the BSC is very powerful and sound tool among all the available performance measurement systems. Also, the model was based on the AHP (Analytic Hierarchy Process) to make the model more structured, and to draw weights of performance measures from experts

TCE Exposure Assessment of Cleaning Workers (세척공정의 트리클로로에틸렌 TWA 및 STEL 평가 사례)

  • Hyun Soo Kim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.1
    • /
    • pp.3-5
    • /
    • 2023
  • Objective: This study introduces exposure concentrations of time-weighted average standard (TWA) evaluation and short-time exposure standard (STEL) evaluation for trichloroethylene in the cleaning process. Methods: Trichloroethylene measurement was conducted according to the KOSHA Guide (A-24-2019) method. It was carried out twice. Results: As a result of the first measurement, TWA concentration exceeded 4 times the exposure standard and STEL concentration exceeded 16 times, but the inaccuracy and breakthrough of the collection time could not be considered, so the second measurement was conducted. The second measurement result was lower than the first measurement result, but exceeded the exposure standards (TWA, STEL). Conclusions: We were able to confirm that the exposure level of workers in the cleaning process using trichloroethylene exceeded the exposure standard. And it is also considered necessary to grasp the approximate concentration using a detector tube in the preliminary survey.

Target Birth Intensity Estimation Using Measurement-Driven PHD Filter

  • Zhang, Huanqing;Ge, Hongwei;Yang, Jinlong
    • ETRI Journal
    • /
    • v.38 no.5
    • /
    • pp.1019-1029
    • /
    • 2016
  • The probability hypothesis density (PHD) filter is an effective means to track multiple targets in that it avoids explicit data associations between the measurements and targets. However, the target birth intensity as a prior is assumed to be known before tracking in a traditional target-tracking algorithm; otherwise, the performance of a conventional PHD filter will decline sharply. Aiming at this problem, a novel target birth intensity scheme and an improved measurement-driven scheme are incorporated into the PHD filter. The target birth intensity estimation scheme, composed of both PHD pre-filter technology and a target velocity extent method, is introduced to recursively estimate the target birth intensity by using the latest measurements at each time step. Second, based on the improved measurement-driven scheme, the measurement set at each time step is divided into the survival target measurement set, birth target measurement set, and clutter set, and meanwhile, the survival and birth target measurement sets are used to update the survival and birth targets, respectively. Lastly, a Gaussian mixture implementation of the PHD filter is presented under a linear Gaussian model assumption. The results of numerical experiments demonstrate that the proposed approach can achieve a better performance in tracking systems with an unknown newborn target intensity.

A study on the establishment of an MES system that converges design, processing, and measurement during cutting (절삭가공 시 설계, 가공, 측정을 융합한 MES 시스템 구축에 관한 연구)

  • Park, Hae-Woong;Lee, Seung-Wook;Han, Heui-Bong;Yun, Jae-Woong;Choi, Kye-Kwang;Han, Seong-Ryeol;Kim, Kyung-A;Lee, Chun-Kyu
    • Design & Manufacturing
    • /
    • v.15 no.2
    • /
    • pp.42-48
    • /
    • 2021
  • In this paper, when manufacturing large/multi-mold parts (more than 30 core parts),A mold manufacturing (tolerance) management system was established through design-processing linkage.The mold manufacturing (tolerance) management system is a design-based measurement shape/measurement position determination system, M/C processing-linked measurement drive system,It is composed of four parts: CAD-linked measurement result analysis system and manager mold part quality management system.In addition, the constructed system was applied to the field and the effect of system construction was evaluated by comparing it with the existing process.As a result of the evaluation, the measurement precision is within 0.02mm, and the time it takes to measure after the end of processing is shorter than that of the existing process.(12 hours → 2 hours) It was shortened to 16.7%.In addition, it was confirmed that the time required for reprocessing after measurement was reduced by 25% (4 hours → 1 hour) compared to the existing process.

Measurement Technology of Chamber Impedance for RF Matching (RF 정합 특성 개선을 위한 챔버의 임피던스 측정법)

  • 설용태;이의용;박성진
    • Journal of the Semiconductor & Display Technology
    • /
    • v.2 no.4
    • /
    • pp.13-17
    • /
    • 2003
  • An adaptor is designed for chamber impedance measurement of plasma process. Copper rod, fixed board and compensation circuit are the major components of the adaptor. An adaptor can be to measure chamber impedance on time unless stopping a process and Data to measure can do the database. We can use it to a criteria data for a failure diagnosis. So developed adaptor could be used for diagnosis the plasma process chamber in semiconductor industry.

  • PDF

Cost-Efficient and Automatic Large Volume Data Acquisition Method for On-Chip Random Process Variation Measurement

  • Lee, Sooeun;Han, Seungho;Lee, Ikho;Sim, Jae-Yoon;Park, Hong-June;Kim, Byungsub
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.2
    • /
    • pp.184-193
    • /
    • 2015
  • This paper proposes a cost-efficient and automatic method for large data acquisition from a test chip without expensive equipment to characterize random process variation in an integrated circuit. Our method requires only a test chip, a personal computer, a cheap digital-to-analog converter, a controller and multimeters, and thus large volume measurement can be performed on an office desk at low cost. To demonstrate the proposed method, we designed a test chip with a current model logic driver and an array of 128 current mirrors that mimic the random process variation of the driver's tail current mirror. Using our method, we characterized the random process variation of the driver's voltage due to the random process variation on the driver's tail current mirror from large volume measurement data. The statistical characteristics of the driver's output voltage calculated from the measured data are compared with Monte Carlo simulation. The difference between the measured and the simulated averages and standard deviations are less than 20% showing that we can easily characterize the random process variation at low cost by using our cost-efficient automatic large data acquisition method.