• 제목/요약/키워드: premolar

검색결과 984건 처리시간 0.033초

Comparison of dental radiography and computed tomography: measurement of dentoalveolar structures in healthy, small-sized dogs and cats

  • Lee, Seunghee;Lee, Kichang;Kim, Hyeona;An, Jeongsu;Han, Junho;Lee, Taekwon;Jeong, Hogyun;Cho, Youngkwon
    • Journal of Veterinary Science
    • /
    • 제21권5호
    • /
    • pp.75.1-75.8
    • /
    • 2020
  • Background: Dental diseases are common in dogs and cats, and accurate measurements of dentoalveolar structure are important for planning of treatment. The information that the comparison computed tomography (CT) with dental radiography (DTR) is not yet reported in veterinary medicine. Objectives: The purpose of this study was to compare the DTR with CT of dentoalveolar structures in healthy dogs and cats, and to evaluate the CT images of 2 different slice thicknesses (0.5 and 1.0 mm). Methods: We included 6 dogs (2 Maltese and 1 Spitz, Beagle, Pomeranian, mixed, 1 to 8 years, 4 castrated males, and 2 spayed female) and 6 cats (6 domestic short hair, 8 months to 3 years, 4 castrated male, and 2 spayed female) in this study. We measured the pulp cavity to tooth width ratio (P/T ratio) and periodontal space of maxillary and mandibular canine teeth, maxillary fourth premolar, mandibular first molar, maxillary third premolar and mandibular fourth premolar. Results: P/T ratio and periodontal space in the overall dentition of both dogs and cats were smaller in DTR compared to CT. In addition, CT images at 1.0 mm slice thickness was generally measured to be greater than the images at 0.5 mm slice thickness. Conclusions: The results indicate that CT with thin slice thickness provides more accurate information on the dentoalveolar structures. Additional DTR, therefore, may not be required for evaluating dental structure in small-sized dogs and cats.

Pont 지수의 임상적 적합성에 대한 평가 (An evaluation of the adequacy of pont's index)

  • 김성훈;이기수
    • 대한치과교정학회지
    • /
    • 제30권1호
    • /
    • pp.115-126
    • /
    • 2000
  • 치열궁의 확장은 치아의 총생 부정교합을 비발치로 치료하기 위한 방법중 하나이며, 치열궁 확장의 진단과 치료를 위하여 상악절치의 근원심 폭경으로부터 이상적인 제1소구치간 치열궁 폭경과 제1대구치간 치열궁 폭경을 예측하는 공식이 제시되어 있다. 이 연구의 목적은 제시된 공식중에서 Pont의 예측식, Schmuth의 예측식 및 Cha들의 예측식을 정상교합의 계측과 비교하고, 이들 예측식의 임상적 신뢰성을 평가하는 것이다. 13세에서 23세사이의 한국인 태생 정상교합자의 석고모형을 대상으로 상악 절치 근원심 폭경,제1소구치간 치열궁 폭경 및 제1대구치간 치열궁 폭경사이의 상관관계를 평가하였으며, 정상교합의 절치폭경의 합을 Pont의 예측식, Schmuth의 예측식 및 Cha 들의 예측식에 대입하여 이상적 제1소구치간 및 제1대구치간 치열궁 폭경의 예측치를 산출하고, 이를 정상교합자의 그것과 비교하여 다음의 결과와 결론을 얻었다. 1. 정상교합에서 상악 절치 근원심 폭경의 합 (SI)으로부터 산출된 제1소구치간 치열궁 폭경 지수는 81.96이었고, 제1대구치간 치열궁 폭경 지수는 62.55이었다. 2. 정상교합에서 상악 절치 근원심 폭경의 합 (SI)과 제1소구치간 치열궁 폭경 (PmW)사이의 상관계수는 0.50이었고, 제1대구치간 치열궁 폭경(MW)사이의 상관계수는 0.39로 모두 통계적 유의성이 있는 저도의 상관관계를 나타냈다. 3. 정상교합에서 상악 절치 근원심 폭경의 합으로부터 제1소구치간 폭경과 제1대구치간 폭경의 예측을 위한 상관식은 신뢰성이 매우 낮았다 ($r^2\;=\;0.25,\;r^2\;=\;0.15$). 4. 이상적 제1소구치간 치열궁 폭경의 예측에 있어서 Pont와 Schmuth의 예측식은 실제보다 크게 예측되는 경향을 보였으며, Cha 들의 예측식은 보다 크거나 작게 예측되는 비율이 같았다. 5. 이상적 제1소구치간 치열궁 폭경의 예측이 1 mm의 오차한계 이내로 예측된 경우는 Cha들의 예측식이 가장 높으며 ($45\%$), Pont의 예측식과 Schmuth의 예측식은 각각 $40\%$$39\%$ 이었다. 5. 이상적 제1대구치간 치열궁 폭경의 예측에 있어서 모든 예측식은 작게 예측되는 경향을 보였으며, 그 중에서도 Cha 들의 예측식은 예측성이 가장 양호하였다. 7 이상적 제1대구치간 치열궁 폭경의 예측이 1 mm의 오차한계 이내로 예측된 경우는 Cha 들의 예측식이 $40\%$ 로 가장 높으며, Pont와 Schmuth의 예측식은 각각 $29\%$$13\%$ 이었다. 이상의 결과는 상악 절치의 근원심 폭경의 합으로부터 이상적 제1소구치간 치열궁 폭경 및 제1대구치간 치열궁 폭경을 예측하는 것은 임상적 신뢰성이 낮을 것임을 시사한다.

  • PDF

하악 영구치아의 발육과 연령과의 관계 및 치아 발육에 따른 치아의 위치 변화 (RELATIONSHIP BETWEEN THE DEVELOPMENTAL STAGE AND CHRONOLOGICAL AGE, AND THE CHANGES OF TOOTH POSITION IN RELATION TO THE TOOTH DEVELOPMENT ON MANDIBULAR PERMANENT TEETH)

  • 김현미;양승덕;김현정;김영진;남순현
    • 대한소아치과학회지
    • /
    • 제29권4호
    • /
    • pp.607-617
    • /
    • 2002
  • 연령과 치아 발육상태 단계와의 상관관계, 치아의 발육에 따른 치아의 이동상태를 평가하기 위하여 최근 5년 이내에 경북대학교 병원에 내원한 아동(남아 446명, 여아 326명)의 파노라마 방사선사진을 대상으로 하여, Moorrees의 기준에 의하여 하악 영구치아의 발육단계를 평가한 후, 발육단계와 연령, 치조골내 치아의 위치를 평가하여 다음과 같은 결론을 얻었다. 치아의 발육시기는 치관이 완료될 때까지 남, 여의 차이가 없었으나, 치근형성이 되면서 부터는 남아보다 여아에서 더 빨리 발육되는 경향을 나타내었다. 치관형성의 완료시점의 평균연령은 남아 여아 각각에서 중절치 3.71, 4.05세, 측절치 4.44, 4.60세, 견치 5.35, 5.11세, 제1소구치 6.62, 6.36세, 제2소구치 7.36, 7.17세, 제1대구치 3.51, 3.69세, 제2대구치 7.90, 7.64세 이었고, 치근단이 폐쇄되기 전단계인 $A_{1/2}$는 중절치 8.70, 8.18세, 측절치 9.55, 8.99세, 견치 12.48, 11.60세, 제1소구치 12.30, 12.01세, 제2소구치 12.19, 12.26세, 제1대구치 912, 8.87세, 제2대구치 12.59, 12.45세 이었다. 치조골내의 교두점 위치는 치관형성 완료시까지는 거의 변화가 없었으나, 치근이 형성됨에 따라 빠르게 교합평면을 향해 이동하였고, 치근형성 완료단계(Rc)에서 다시 움직임 없이 정체되었다. 치근단의 위치는 치관형성 시작부터 치근 1/4 형성 시까지 일정한 위치에 유지되었으나, 그 후에 급격하게 교합면 쪽으로 이동하였고, 치근 3/4 형성시점부터 비교적 일정한 위치에 유지되었다. 치아의 석회화가 시작되는 초기의 치배 위치는 견치가 가장 하방에 위치하였으며, 그 다음이 제2소구치, 제1소구치, 측절치 제2대구치, 제1대구치 순이었고, 중절치가 가장 상방에 위치하였다.

  • PDF

교합면 열구 법랑질의 미세구조 및 산부식 형태 (ULTRA-STRUCTURE AND ACID ETCHING CHARACTERISTICS OF OCCLUSAL FISSURE ENAMEL)

  • 조태식;윤정훈;김수관;이상호
    • 대한소아치과학회지
    • /
    • 제32권2호
    • /
    • pp.321-331
    • /
    • 2005
  • 치면열구전색제의 접착력에 영향을 줄 수 있는 교합면 열구 법랑질의 미세구조 및 산부식 형태, 그리고 산부식 형태에 영향을 줄 수 있는 prismless enamel의 존재 여부 및 법랑질의 화학적 조성을 규명하고자 소구치를 대상으로 협설면과 근원심으로 각각 절단하여 열구내의 법랑질 표면과 산부식 형태를 주사전자현미경으로 관찰하고 EDX를 사용하여 법랑질의 화학적 조성을 분석한 결과 다음과 같은 결과를 얻었다. 1. 열구내 법랑질은 대부분이 prismless enamel이 존재하였다. 2. 미성숙 영구치와 성숙된 영구치간의 열구내 법랑질 표면 구조 및 산부식 형태는 차이가 없었다. 3. 열구 법랑질은 부위에 관계없이 60초 산부식이 15초, 30초, 45초에 비해 산부식 효과가 가장 컸으며 15초, 30초, 45초의 산부식 시간에서는 적절한 유지력을 얻을 수 있는 산부식 상이 관찰되지 않았다. 4. 열구 법랑질의 표면을 기계적으로 제거한 경우는 30초의 산부식 시간에서도 60초 산부식 시간에 못지않은 전형적인 산부식 상이 관찰되었다. 5. 산부식 형태는 주로 rod 주위가 소실된 제 2형의 산부식 상이 관찰되었다. 6. 열구 내 법랑질의 부위별 화학적 조성의 차이는 없었으나 미성숙 영구치와 성숙된 영구치 사이의 칼슘/인 비는 유의한 차이를 보였다. 이상의 연구결과를 종합하면 교합면 열구 내 법랑질은 대부분 산에 저항성이 큰 prismless enamel로 덮여 있어 기존에 제안된 15-30초의 산부식 시간으로는 적절한 유지력을 얻을 수 있는 산부식 상을 형성할 수 없다는 사실을 알 수 있다. 따라서 기존의 제안된 산부식 시간에 대한 재고가 필요하며 이와 함께 적절한 산부식 상을 얻기 위한 방안으로 산부식 전 bur를 사용하여 열구내 법랑질 표면을 제거해 주는 보조적인 술식에 대한 검토가 필요하리라 사료된다.

  • PDF

고정성 보철치료에서 골유착성 임프란트의 경사도변화에 따른 변위와 응력에 관한 유한요소적 연구 (A FINITE ELEMENT ANALYSIS ON THE 3-UNIT FIXED PROSTHESIS SUPPORTED WITH A NATURAL TOOTH AND ANGLE VARIABLE IMPLANT)

  • 고현;우이형;박남수
    • 대한치과보철학회지
    • /
    • 제31권4호
    • /
    • pp.580-610
    • /
    • 1993
  • The purpose of this study was to analyse the deflection and stress distribution at the supporting bone and it's superstructure by the alteration of angulation between implant and it's implant abutment. For this study, the free-end saddle case of mandibular first and second molar missing would be planned to restore with fixed prosthesis. So the mandibular second premolar was prepared for abutment, and the cylinder type osseointegrated implant was placed at the site of mandibular second molar for abutment. The finite element stress analysis was applied for this study. 13 two-dimensional FEM models were created, a standard model at $0^{\circ}$ and 12 models created by changing the angulation between implant and implant abutment as increasing the angulation mesially and distally with $5^{\circ}$ unittill $30^{\circ}$. The preprocessing decording, solving and postprocessing procedures were done by using FEM analysis software PATRAN and SUN-SPARC2GX. The deflections and von Mises stresses were calculated under concentrated load (load 1) and distributed load(load 2) at the reference points. The results were as follows : 1. Observing at standard model, the amount of total deflection at the distobuccal cusp-tip of pontic under concentrated load was largest of all, and that at the apex of implant was least of all, and the amount of total deflection at the buccal cusp-tip of second premolar under distributed load was largest of all, and that at the apex of implant was least of all. 2. Increasing the angulation mesially or distally, the amounts of total deflection were increased or decreased according to the reference points. But the order according to the amount of total deflection was not changed except apex of second premolar and central fossa of implant abutment under concentrated load during distal inclination. 3. Observing at standard model, the von Mises stress at the distal joint of pontic under concentrated load was largest of all, and that at the apex of implant was least of all. The von Mises stress at the distal margin of second premolar under distributed load was largest of all, and that at the apex of Implant was least of ail. 4. Increasing the angulation of implant mesially, the von Mises stresses at the mesial crest of implant were increased under concentrated load and distributed load, but those were increased remarkably under distributed load and so that at $30^{\circ}$ mesial inclination was largest of all. 5. Increasing the angulation of implant distally, the von Mises stresses at the distal crest of implant were increased remarkably under concentrated load and distributed load, and so those at $30^{\circ}$ distal inclination were largest of all.

  • PDF

총의치 온성방법에 따른 교합 및 수직 고경의 변화 (OCCLUSION AND VERTICAL DIMENSION CHANGES ACCORDING TO DENTURE PROCESSING TECHNIQUES)

  • 김문영;정관호;유형우;안승근;송광엽;박찬운
    • 대한치과보철학회지
    • /
    • 제34권2호
    • /
    • pp.277-289
    • /
    • 1996
  • The purpose of this study was to compare the amount of the vertical pin opening of dentures processed by the conventional compression method & the injection-processing method. The articulating ribbon and T-Scan system were used to determine the changes in tooth contacts and the correlation between the changes in tooth contacts and the amount of the vertical pin opening after processing was analyzed statistically. The obtained results were as follows. 1. The amounts of the vertical pin opening were 0.75mm, 0.31mm for conventional compression method and injection-pressing method, respectively. The difference between the two methods was highly significant on the basis of t test statistics(p<0.05). 2. The total number of contact points recorded by articulating ribbon after processing was decreased to 48%, 72%, of that before processing for conventional compression method and injection-pressing method, by T-Scan system, 39%, 53%, respectively. 3. The mean values for the number of contacts points per tooth recorded by articulating ribbon after processing were 1.6 for the second molar, 2.2 for the first moalr, 0.4 for the second premolar, 0.6 for the first premolar in conventional compression method, and 2, 3.2, 1.2, 0.8 in injection-pressing method. 4. The correlation between the reduction of contact points and the amount of the pin opening after processing was not significant. 5. The mean values for the number of contact points per tooth recorded by T-Scan system after processing were 1.25, 1.4, 0.7, and 0.55 at the second molar, the first molar, the second premolar, and the first premolar in conventional compression method, and 1.45, 2.1, 1.0, 0.75 in injection method, respectively. 6. The correlation between the number of contact points by using articulating ribbon and T-Scan system after processing was not significant in both methods.

  • PDF

고정성 보철물을 지지하는 골유착성 임플란트의 위치에 따른 지지조직에서의 유한요소적 응력분석 (Finite Element Stress Analysis on the Supporting Tissues depending upon the Position of Osseointegrated Implants Supporting Fixed Bridges)

  • 윤동주;신상완;서규원
    • 대한치과보철학회지
    • /
    • 제31권1호
    • /
    • pp.87-99
    • /
    • 1993
  • Many studies have been reported on the successful replacement of missing teeth with osseointegrated dental Implants. However, little research has been carried out on the bio-mechanical aspect of the stress on the surrounding bone of the free-standing type of dental implant prostheses. This experimental study was aimed to analyze the stress distribution pattern on the supporting tissues depending upon the position of osseointegrated implants supporting fixed bridges. In the cases of unilateral partially edentulous mandible (the 2nd premolar and the 1st and 2nd molars missing), two osseointegrated implants were placed at the 2nd premolar and 2nd molar sites (Model A) , the 1st and 2nd molar sites (Model B, Anterior cantilevered type), the 2nd premolar and 1st molar sites (Model C, Posterior cantilevered type). Chewing forces of dentate patients and denture wearer were applied vertically on the 2nd premolar, the 1st molar, and the 2nd molar of each model. A 3-Unit fixed partial denture was constructed at each model and cantilevered extension parts were involved in Model B and Model C. Two dimensional finite element analysis was undertaken. The commercial software (Super SAP) for IBM 16 bit personal computer was utilized. The results were as follows : 1. The magnitude of applied load influenced on the total value of stresses, but did not in-fluence on the pattern of stress distribution. 2. The magnitude of stress developed from the supporting tissues were in order of Model C,Model A,Model B. 3. High stresses were concentrated on the cervical and apical portion of the implant/bone interface. 4. A difference of the stress magnitude on the implant/bone interface between mesial and distal implant was most prominant in Model C and in order of Model A and Model B. 5. The stresses developed in Model A were evenly distributed throughout both implants. 6. The stresses concentrated on the cervical portion of cantilevered side were higher in the posterior cantilevered type than in the anterior cantilevered type.

  • PDF

상악골 전방 견인이 상악골체의 변위에 미치는 영향 (EFFECTS OF MAXILLARY PROTRACTION ON THE DISPLACEMENT OF THE MAXILLA)

  • 고정석;김종철
    • 대한치과교정학회지
    • /
    • 제25권5호
    • /
    • pp.543-555
    • /
    • 1995
  • 골격성 부정교합에 대한 악정형 치료시, 바람직한 악정형 효과를 얻기 위해서는 악정형 장치의 역학 현상에 대한 분석이 필요하다. 상악의 저성장에 기인한 골격성 III급 부정교합의 치료를 위한 상악골의 전방견인시 바람직한 견인력 방향과 견인 위치를 알아보기 위해, 성인 두개골을 대상으로 3차원 유한 요소 모델을 제작하여, 제1소구치와 제1대구치에서 각각 교합평면에 평행 또는 $20^{\circ}$ 하방으로 500g의 전방 견인력을 주어 상악골체의 각 부분에서 응력과 변위를 분석하여 다음과 같은 결과를 얻었다. 1. 모든 경우 상악골이 반시계 방향으로 회전하는 양상을 보였다. 2. 견인력 방향에 따른 상악골의 회전은, $20^{\circ}$ 하방으로 견인하는 경우가 평행하게 견인하는 경우보다 더 적었다. 3. 견인 위치에 따른 상악골의 회전은, 평행하게 견인시에는 견인 위치가 제1대구치일 때가, $20^{\circ}$ 하방으로 견인시에는 제1소구치일 때가 더 적었다. 이상의 결과 견인력 작용선이 상악골체의 저항 중심점에 가장 근접하여 반시계 방향으로의 변위가 가장 적게 일어난 제1소구치에서 $20^{\circ}$ 하방으로 견인한 경우가 바람직한 견인력 방향과 견인 위치로 판단되었다.

  • PDF

White light scanner-based repeatability of 3-dimensional digitizing of silicon rubber abutment teeth impressions

  • Jeon, Jin-Hun;Lee, Kyung-Tak;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권4호
    • /
    • pp.452-456
    • /
    • 2013
  • PURPOSE. The aim of this study was to evaluate the repeatability of the digitizing of silicon rubber impressions of abutment teeth by using a white light scanner and compare differences in repeatability between different abutment teeth types. MATERIALS AND METHODS. Silicon rubber impressions of a canine, premolar, and molar tooth were each digitized 8 times using a white light scanner, and 3D surface models were created using the point clouds. The size of any discrepancy between each model and the corresponding reference tooth were measured, and the distribution of these values was analyzed by an inspection software (PowerInspect 2012, Delcamplc., Birmingham, UK). Absolute values of discrepancies were analyzed by the Kruskal-Wallis test and multiple comparisons (${\alpha}$=.05). RESULTS. The discrepancy between the impressions for the canine, premolar, and molar teeth were $6.3{\mu}m$ (95% confidence interval [CI], 5.4-7.2), $6.4{\mu}m$ (95% CI, 5.3-7.6), and $8.9{\mu}m$ (95% CI, 8.2-9.5), respectively. The discrepancy of the molar tooth impression was significantly higher than that of other tooth types. The largest variation (as mean [SD]) in discrepancies was seen in the premolar tooth impression scans: $26.7{\mu}m$ (95% CI, 19.7-33.8); followed by canine and molar teeth impressions, $16.3{\mu}m$ (95% CI, 15.3- 17.3), and $14.0{\mu}m$ (95% CI, 12.3-15.7), respectively. CONCLUSION. The repeatability of the digitizing abutment teeth's silicon rubber impressions by using a white light scanner was improved compared to that with a laser scanner, showing only a low mean discrepancy between $6.3{\mu}m$ and $8.9{\mu}m$, which was in an clinically acceptable range. Premolar impression with a long and narrow shape showed a significantly larger discrepancy than canine and molar impressions. Further work is needed to increase the digitizing performance of the white light scanner for deep and slender impressions.

매복된 제 2유구치와 제 2소구치 치배의 전위에 관한 증례 보고 (TRANSPOSITION OF THE IMPACTED PRIMARY SECOND MOLAR AND THE TOOTH GERM OF SECOND PREMOLAR)

  • 김송이;최성철;김광철;이긍호;최영철;박재홍
    • 대한소아치과학회지
    • /
    • 제33권4호
    • /
    • pp.722-727
    • /
    • 2006
  • 치아가 정상적으로 맹출해야 하는 시기를 지나서도 골조직 내에서 맹출하지 않을 수 있으며, 이러한 치아를 매복치라 한다. 유치의 매복은 드물게 나타나며, 더구나 과거의 문헌 고찰에 의하면 현재까지 보고된 계승 영구치 하방에 매복된 유치는 극히 드물다. 대부분의 경우 매복된 유치는 제 2 유구치이다. 유치의 매복에 대한 병인은 유치 치배의 비정상적인 발달로 인해 조기에 유착이 일어나는 것으로 추측되어지고 있으나, 아직까지 정확하게 밝혀진 바는 없다. 전위는 동일한 사분악 내의 인접한 두 개 치아의 위치가 서로 바뀐 것을 말하며, 영구 상악 견치와 제 1소구치 사이에 가장 많이 발생한다. 그 빈도는 1% 내외로 낮으며, 특히 유치열의 전위는 거의 발표된 바가 없다. 본 증례는 양악 양측 제 2유구치의 매복을 주소로 본과에 의뢰된 환자의 구강 및 방사선 검사 결과 매복된 제 2유구치와 후속 제 2소구치 사이의 수직 전위가 관찰되었기에 보고하는 바이다.

  • PDF