References
- Persson A, Andersson M, Oden A, Sandborgh-Englund G. A three-dimensional evaluation of a laser scanner and a touchprobe scanner. J Prosthet Dent 2006;95:194-200. https://doi.org/10.1016/j.prosdent.2006.01.003
- Schaefer O, Kuepper H, Sigusch BW, Thompson GA, Hefti AF, Guentsch A. Three-dimensional fit of lithium disilicate partial crowns in vitro. J Dent 2013;41:271-7. https://doi.org/10.1016/j.jdent.2012.11.014
- Schaefer O, Watts DC, Sigusch BW, Kuepper H, Guentsch A. Marginal and internal fit of pressed lithium disilicate partial crowns in vitro: a three-dimensional analysis of accuracy and reproducibility. Dent Mater 2012;28:320-6. https://doi.org/10.1016/j.dental.2011.12.008
- Hewlett ER, Orro ME, Clark GT. Accuracy testing of threedimensional digitizing systems. Dent Mater 1992;8:49-53. https://doi.org/10.1016/0109-5641(92)90053-F
- Luthardt RG, Sandkuhl O, Herold V, Walter MH. Accuracy of mechanical digitizing with a CAD/CAM system for fixed restorations. Int J Prosthodont 2001;14:146-51.
- Dahlmo KI, Andersson M, Gellerstedt M, Karlsson S. On a new method to assess the accuracy of a CAD program. Int J Prosthodont 2001;14:276-83.
- Kuroda T, Motohashi N, Tominaga R, Iwata K. Threedimensional dental cast analyzing system using laser scanning. Am J Orthod Dentofacial Orthop 1996;110:365-9. https://doi.org/10.1016/S0889-5406(96)70036-7
- Persson AS, Odén A, Andersson M, Sandborgh-Englund G. Digitization of simulated clinical dental impressions: virtual three-dimensional analysis of exactness. Dent Mater 2009;25: 929-36. https://doi.org/10.1016/j.dental.2009.01.100
- Lee KT, Kim JH, Kim WC, Kim JH. Three-dimensional evaluation on the repeatability and reproducibility of dental scanner- based digital models. J Korean Acad Dent Tech 2012;34: 213-20.
- Quaas S, Rudolph H, Luthardt RG. Direct mechanical data acquisition of dental impressions for the manufacturing of CAD/CAM restorations. J Dent 2007;35:903-8. https://doi.org/10.1016/j.jdent.2007.08.008
- DeLong R, Pintado MR, Ko CC, Hodges JS, Douglas WH. Factors influencing optical 3D scanning of vinyl polysiloxane impression materials. J Prosthodont 2001;10:78-85. https://doi.org/10.1111/j.1532-849X.2001.00078.x
- Luthardt RG, Kühmstedt P, Walter MH. A new method for the computer-aided evaluation of three-dimensional changes in gypsum materials. Dent Mater 2003;19:19-24. https://doi.org/10.1016/S0109-5641(02)00013-1
- Nazzal R. CAD scanners and design software. Inside Dent Tech 2012;3:7.
- Blais F. Review of 20 years of range sensor development. J Electron Imaging 2004;13:231-40. https://doi.org/10.1117/1.1631921
Cited by
- Accuracy of 3D white light scanning of abutment teeth impressions: evaluation of trueness and precision vol.6, pp.6, 2014, https://doi.org/10.4047/jap.2014.6.6.468
- Three-dimensional evaluation of the repeatability of scans of stone models and impressions using a blue LED scanner vol.34, pp.5, 2015, https://doi.org/10.4012/dmj.2014-347
- Accuracy of intraoral and extraoral digital data acquisition for dental restorations vol.24, pp.1, 2016, https://doi.org/10.1590/1678-775720150266
- Repeatability and reproducibility of individual abutment impression, assessed with a blue light scanner vol.8, pp.3, 2016, https://doi.org/10.4047/jap.2016.8.3.214
- Trueness and precision of scanning abutment impressions and stone models according to dental CAD/CAM evaluation standards vol.10, pp.5, 2018, https://doi.org/10.4047/jap.2018.10.5.335
- Evaluation of the reproducibility of various abutments using a blue light model scanner vol.10, pp.4, 2018, https://doi.org/10.4047/jap.2018.10.4.328
- 세 가지 방식의 스캐너 종류에 따른 모형 정확도 평가 vol.15, pp.2, 2013, https://doi.org/10.17135/jdhs.2015.15.2.226
- Simulation-based scanning of a structured light system for objects without overhangs vol.54, pp.19, 2016, https://doi.org/10.1080/00207543.2015.1109722
- Trueness of CAD/CAM digitization with a desktop scanner - an in vitro study vol.19, pp.1, 2013, https://doi.org/10.1186/s12903-019-0976-1
- Digital impressions in dentistry-accuracy of impression digitalisation by desktop scanners vol.24, pp.3, 2013, https://doi.org/10.1007/s00784-019-02995-w