• Title/Summary/Keyword: multi-frequency characteristics

Search Result 663, Processing Time 0.036 seconds

Broadband Multi-Layered Radome for High-Power Applications (고출력 환경에 적용 가능한 광대역 다층 구조 레이돔)

  • Lee, Ki Wook;Lee, Kyung Won;Moon, Bang Kwi;Choi, Samyeul;Lee, Wangyong;Yoon, Young Joong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.1
    • /
    • pp.50-60
    • /
    • 2018
  • In this paper, we developed a broadband multi-layered radome applicable for high-power applications. In this regard, we presented the wave propagation characteristics of the broadband multi-layered radome with the ABCD matrix and obtained the optimal thickness and the material constant for each layer by an optimization algorithm called "particle swarm optimization," implemented by a commercial numerical modeling tool. Further, we redesigned it in view of mechanical properties to reflect environmental conditions such as wind, snow, and ice. The power transmission property was reanalyzed based on the recalculated data of each layer's thickness to consider the limitations of the fabrication of a large structure. Under the condition of a peak electric field strength that is 10 dB above the critical electric field strength in air breakdown, we analyzed the air breakdown by radio frequency(RF) in the designed radome using the commercial full-wave electromagnetic tool. The radome was manufactured and tested by continuous wave(CW) RF small signal and large signal in an anechoic chamber. The test results showed good agreement with those attained by simulation.

Method of a Multi-mode Low Rate Speech Coder Using a Transient Coding at the Rate of 2.4 kbit/s (전이구간 부호화를 이용한 2.4 kbit/s 다중모드 음성 부호화 방법)

  • Ahn Yeong-uk;Kim Jong-hak;Lee Insung;Kwon Oh-ju;Bae Mun-Kwan
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.2 s.302
    • /
    • pp.131-142
    • /
    • 2005
  • The low rate speech coders under 4 kbit/s are based on sinusoidal transform coding (STC) or multiband excitation (MBE). Since the harmonic coders are not efficient to reconstruct the transient segments of speech signals such as onsets, offsets, non-periodic signals, etc, the coders do not provide a natural speech quality. This paper proposes method of a efficient transient model :d a multi-mode low rate coder at 2.4 kbit/s that uses harmonic model for the voiced speech, stochastic model for the unvoiced speech and a model using aperiodic pulse location tracking (APPT) for the transient segments, respectively. The APPT utilizes the harmonic model. The proposed method uses different models depending on the characteristics of LPC residual signals. In addition, it can combine synthesized excitation in CELP coding at time domain with that in harmonic coding at frequency domain efficiently. The proposed coder shows a better speech quality than 2.4 kbit/s version of the mixed excitation linear prediction (MELP) coder that is a U.S. Federal Standard for speech coder.

A new algorithm for SIP parameter estimation from multi-frequency IP data: preliminary results (다중 주파수 IP 자료를 이용한 SIP 변수 추정)

  • Son, Jeong-Sul;Kim, Jung-Ho;Yi, Myeong-Jong
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.1
    • /
    • pp.60-68
    • /
    • 2007
  • Conventional analysis of spectral induced polarization (SIP) data consists of measuring impedances over a range of frequencies, followed by spectral analysis to estimate spectral parameters. For the quantitative and accurate estimation of subsurface SIP parameter distribution, however, a sophisticated and stable inversion technique is required. In this study, we have developed a two-step inversion approach to obtain the two-dimensional distribution of SIP parameters. In the first inversion step, all the SIP data measured over a range of frequencies are simultaneously inverted, adopting cross regularisation of model complex resistivities at each frequency. The cross regularisation makes it possible to enhance the noise characteristics of the inversion by imposing a strong assumption, that complex resistivities should show similar characteristics over a range of frequencies. In numerical experiments, we could verify that our inversion approach successfully reduced inversion artefacts. As a second step, we have also developed an inversion algorithm to obtain SIP parameters based on the Cole-Cole model, in which frequency-dependent complex resistivities from the first step are inverted to obtain a two-dimensional distribution of SIP parameters. In numerical tests, the SIP parameter images showed a fairly good match with the exact model, which suggests that SIP imaging can provide a very useful subsurface image to complement resistivity.

Association between Caregiver's Awareness of Human Rights and Quality of Service: Focused on Human Right Education (요양보호사의 노인인권의식과 서비스 질에 대한 인식 수준의 관련성: 인권교육 조절효과 중심으로)

  • Eun-Sim Jeong;Young-Joon Seo;Young-Joo Won;Min-Hee Heo;Jin-Won Noh
    • Health Policy and Management
    • /
    • v.33 no.3
    • /
    • pp.311-324
    • /
    • 2023
  • Background: Long-term care insurance for the elderly has been stably established along with the quantitative expansion of long-term care facilities. Indeed, the need for a paradigm about human rights-based service approach is being raised throughout society from a service perspective. Therefore, this study aimed to analyze the association between elderly human rights awareness and quality of service by considering human rights education as a moderate variable. Methods: This study conducted surveys with 138 caregivers working in long-term care facilities located in Seoul and Gangwon. General characteristics, awareness of human rights, and the level of service quality were examined using descriptive statistics, frequency analysis, and correlation analysis. And multi-variable linear regression with a hierarchical framework was employed. These analyses were performed using IBM SPSS ver. 25.0. Results: Of the 138 caregivers, 97.1% were female, 87.7% were more than 50 years old, and most of their education level was high-school graduates. Their length of employment ranged from more than 5 years to less than 10 years. The level of awareness regarding elderly human rights of the elderly was below normal (mean=2.21), but the quality of service was high (mean=4.21), and the need for human rights education was also high (mean=4.28). Among the general characteristics, the length of employment was significantly associated with awareness of elderly human rights. Moreover, political rights awareness, included as sub-domains of human rights, was positively associated with quality of service. However, the moderating variable, human rights education, was not significantly associated with the quality of service. Conclusion: In this study, human rights education, as a moderating variable, did not have a statistically significant effect on caregivers' human rights awareness in relation to service quality. This finding is inconsistent with previous research results. These results can be explained by the fact that the frequency of education in long-term care facilities was a significant factor in the practice of protecting the human rights of the elderly. Therefore ongoing encouragement for the frequency of current human rights education and improvements in the educational approach appear to be necessary. In addition, these findings reveal the need for strength of education policies and effective in-depth research about human rights and quality of service to respect the human rights of the elderly.

An Analysis of Bed Change Characteristics by Bed Protection Work (바닥보호공 설치에 따른 하상변동 특성 분석)

  • Son, Ah Long;Kim, Byung Hyun;Moon, Bo Ram;Han, Kun Yeun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.4
    • /
    • pp.821-834
    • /
    • 2015
  • This study presents the analysis of flow and bed change characteristics considering bed protection work built on the immediate downstream of weir to protect river bed from scouring. The study area is 37km reach from Hyunpoong station to Masuwon station including Hapcheon- Changryoung multi-function weir in the Nakdong river. CCHE2D model is calibrated and validated for evaluating the flow and bed change characteristics during Typhoon Kompasu in 2010. Three simulation conditions are set up: Case 1 is a natural channel without installation of weir. Case 2 involves an installation of weir in the natural channel. Case 3 involves an installation of weir with bed protection in the natural channel. Flood frequency (50, 100 and 200yr) is applied to each scenario to analyze the effects of bed protection work. While the sediment rate is increased in the downstream of fixed gate and sluice-type gate, river bed scouring rate is increased in the downstream of lift-type gate in Case 2 comparing with the results of Case 1. The river bed scouring is not occurred in the immediate downstream of weir (~30m) due to the effect of bed protection, but larger amount of sediment is occurred in the downstream of weir (60m~) which the bed protection is not installed comparing with the results Case 1. Through the results of simulation considering bed protection work, this study would be helpful to expect bed change and operate the weir as well as manage.

A High Efficiency Reconfigurable Doherty Amplifier (고효율의 재구성된 도허티 증폭기)

  • Kim, Ell-Kou;Kim, Young;Yoon, Young-Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.12 no.3
    • /
    • pp.220-226
    • /
    • 2008
  • This paper proposes the Reconfigurable Doherty Amplifier(RDA) with asymmetric structure which has ${\lambda}/4$ impedance transformer for modulating the load impedance in peaking amplifier path. This structure is possible to implement a compact size for N-stage multi Doherty amplifier and to get almost same characteristics that is compared to conventional Doherty amplifier. To realize the high efficiency amplifier, we were implemented 45 Watts power amplifier at transmitter band of Wideband Code Division Multiple Access(WCDMA) base-station. As a result, in case of WCDMA 1 Frequency Allocation(FA) input signals, this amplifier has obtained a 26.3% Power Added Efficiency(PAE) at 8 dB back-off point from P1dB and an Adjacent Channel Leakage Power(ACLR) is -40.4 dBc at center frequency ${\pm}5MHz$ deviation.

  • PDF

Output Voltage Harmonics Analysis of NPC Type Three-level Inverter (NPC형 3레벨 인버터의 출력전압 고조파 분석)

  • Kwon, Kyoung-Min;Choi, Jae-Ho;Chung, Gyo-Bum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.472-480
    • /
    • 2009
  • This paper describes the overmodulative SVPWM technique and harmonics analyses of three phase NPC type three-level inverter to the modulation index. Three phase NPC type three-level inverter adopted SVPWM to extend the linear region to 0.907, moreover, the following voltage compensation using Fourier series was adopted in the region of overmodulation to make it work to six-step level. PD type of multi carrier method is used with the double Fourier series for the analysis of output power harmonics characteristic. Simulation was performed by PSIM, and the harmonics characteristics of 3-level inverter in each region are analyzed. The side band harmonics of carrier frequency are dominant in the linear region, but these harmonic components are decreased as the inveter goes to overmodulation region, and the harmonics due to the fundamental frequency is increased gradually at the same time. The harmonic analyses are verified through the simulation and experimental results under the same condition.

A Review of the Possible Causes of Negative Source Impedance in Fluid Machines (유체기계에 있어서 부의 음원 임피던스의 원인에 관한 고찰)

  • ;Keith S. Peat
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.3
    • /
    • pp.76-82
    • /
    • 2001
  • Most fluid machines can be considered as periodic noise sources when operated under constant conditions, which allows for a frequency domain representation of the source and the associated acoustic field In the duct. In such a representation, the source is characterized by frequency-dependent values of both strength and impedance. Although knowledge of these values can be gained by either experimentation or by modeling, one-port acoustic characteristics of an in-duct source with high flow velocity, high temperature, and high sound level can be measured only by the multiload method using an overdetermined set of open pipes with different lengths as applied loads. However, the problem is that negative source resistances have been often measured. This paper reviews the possible causes of the problem, with reference to experimental and theoretical results, in an attempt to clarify the issue. A new interpretation is given for the violation of basic assumptions and the defect in the algorithm of multiload method. The major cause and mechanism of the problem is due to the violation of time invariance assumption of the source and the load impedance can seriously affect the final measured result of source impedance.

  • PDF

Miniaturization of Dual-Element Folded Dipole Antenna Using Zigzag Line for Multi-Band Service (다중 대역 서비스를 위한 지그재그 선로를 이용한 이중 소자 폴디드 다이폴 안테나의 소형화)

  • Jeon, Hoo-Dong;Ko, Ji-Hwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.4
    • /
    • pp.270-276
    • /
    • 2018
  • Fifth-generation communications are approaching, and they will require broadband antennas that include the existing LTE frequency band (1.7 GHz to 2.7 GHz) and the newly allocated frequency band (3.4 GHz to 3.7 GHz). Many kinds of antennas satisfy the required broadband characteristics, including the dual-element folded dipole antenna proposed in this paper. A zigzag line was used to make the antenna more compact. This was accomplished by reducing the physical length while maintaining the electrical length. To validate the proposed antenna, a prototype was fabricated using PCB (${\epsilon}_r$:4.4, Height: 1.6 mm) and its performance was evaluated. Results obtained by simulation and experiment showed good agreement.

Characteristics of Microwave Propagation for the ETC System (ETC 시스템에서의 마이크로파 전파 특성)

  • 배창호;정희창;김영주;장호성
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.5A
    • /
    • pp.696-701
    • /
    • 2000
  • Electronic Toll Collection (ETC) System makes the telecommunication possible between the Beacon and the On Board Unit(OBU) for automatic toll collection. In this paper, the propagation path of microwave is modelled and the induced voltage of receiving antenna is analyzed numerically according to multi-path fading effect. In our modelling, we consider frequency, weather condition, polarization and antenna radiation pattern. Also, we suggest the diversity technique in order to reduce the fading effect. In the resuts, the fading effect is reduced significantly in case of the vertical polarization at the rain condition. In general the circular polarization is the most desirable in this application. The antenna which has the high directivity, is also desirable. Using the space and frequency diversity technique at the Beacon, the fading effect is reduced effectively. These results are compared with our experimental data.

  • PDF