• Title/Summary/Keyword: multi pitch

Search Result 257, Processing Time 0.033 seconds

Fabrication, AC Loss Measurement and Analysis of Bi-2223 Conductors with Respect to Various Twist Pitch (트위스트 피치를 고려한 Bi-2223 선재 제작과 AC 손실 측정 및 분석)

  • Jang, Mi-Hye;Chu, Yong;Lim, Jun-Hyung;Joo, Jin-Ho;Ko, Tae-Kuk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.11
    • /
    • pp.589-595
    • /
    • 2000
  • In this papre, AC losses of Bi-2223 tapes with different twist pitch of superconducting core were fabricated, measured and analyzed. These samples produced by a powder-in-tube method are multi-filamentary tape with Ag matrix. Also, it's produced by non-twist and different twist pitch(8, 10, 13, 30, 50, 70 mn). The critical current measurement was carried out under the environment in Liquid nitrogen and in zero field by 4-probe method. And the AC loss measurement was carried out under the environment of applied time-varying transport current by transport method. From experiment, the critical current is larger non-twist than twisted filament. And, the AC loss by Norris equation is higher non-twisted tape than 13mm twisted tape. Also, it is confirmed that of AC loss of tape having non-twist pitch larger than those having differnet twist pitch.

  • PDF

A Study on the Planning of Multi-Family Residential Buildings considering Daylight, View and Natural Ventilation (일조와 조망, 자연환기성능을 고려한 공동주택 배치계획에 관한 연구)

  • Choi, Doo-Sung;Cho, Kyun-Hyong
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.3
    • /
    • pp.55-64
    • /
    • 2010
  • The study has conducted a research on the main shape of domestic multi-family residential buildings. The four arrangements were selected after the research and each of them was analyzed for daylight, view and natural ventilation according to the different pitch of buildings. Based on the results from the analysis, the optimum pitch of buildings for each of the arrangements are as follows. With looking at the outcomes from the analysis on changes in residential environment by the pitch of building buildings in the four arrangements, it was figured out that it would be the best if the distance is more than 1.0H for Case_1. For Case_2, it should be more than 0.9H and for Case_3, it has to be 1.0H or more. Last but not least, it seems to be superb if the distance is more than 0.9H for Case_4.

Multi-body Dynamics and Position Control Simulation for 2-Axes Gimbals in Naval Shipboard (함정용 2축 안정화 장치의 다물체 동역학 및 위치 제어 해석)

  • Yun, Chan-Shik;Ku, Ki-Young;Kim, Sang-Ik;Jeon, Hee-Ho;Lee, Seung-Joon;Byun, Gi-Sig
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.2
    • /
    • pp.330-340
    • /
    • 2009
  • A naval shipboard inevitably movies in a pitch and roll direction under the influence of wave and wind in the sea. As a result, the shipboard gets in a continuous turning motion back/front and right/left. And the shipboard is also constantly exposed to many different kinds of disturbance signals including the vibrations of various frequencies from the internal equipments and their vibrations, strong waves, and impact from explosion. This paper formulates multi-body dynamic models similar to an actual system and simulates the pitch/roll positions of a 2-axes gimbals with PI controller for consecutive behavior of a naval shipboard including disturbance.

On a Reduction of Pitch Search Time for IMBE Vocoder by Using the Spectral AMDF (SAMDF를 이용한 IMBE VOCODER의 피치 검색 시간 단축에 관한 연구)

  • 홍성훈
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06c
    • /
    • pp.155-158
    • /
    • 1998
  • IMBE(Improved Multi-Band Excitation) vocoders exhibit good performance at low data rates. The major drawback to IMBE coders is their large computational requirements. In this paper, thus, we propose a new pitch search method that preserves the quality of the IMBE vocoder with reduced complexity. The basic idea is to reduce computation complexity of the pitch searching by using the SAMDF. Applying the proposed method to the IMBE vocoder, we can get approximately 52.02% searching time reduction in the pitch search. There is no difference in voice quality between conventional IMBE and proposed IMBE.

  • PDF

A Study on the Mechanical Characteristics of the Resistance Multi-spot Welded Joints (저항 다점용접부의 역학적 특성에 관한 연구)

  • 방한서;방희선
    • Journal of Welding and Joining
    • /
    • v.19 no.5
    • /
    • pp.499-505
    • /
    • 2001
  • In order to classify the mechanical phenomena of thermal elasto-plastic behavior on the multi-spot welded joints, this study has tried to carry out three-dimensional thermal elasto-plastic analysis on them. However, because the shape of multi-spot welded joints is not taxi-symmetric, unlike the cafe of single-spot welded joint, the solution domain for simulation should be three dimension. Therefore, in this paper, firstly, the three-dimensional thermal elasto-plastic program is developed by an iso-parametric finite element method. Secondly, from the results analyzed by developed program, this has clarified mechanical characteristics and their production mechanism on single and multi-spot waled joints. Moreover, it has been intended to make clear effects of pitch length on welding residual stresses, plastic strain of multi-spot welded joints.

  • PDF

An Investigation on Step Responses of Pitch PI Controller for a 2MW Wind Turbine Using Bladed S/W (Bladed S/W를 이용한 2MW급 풍력터빈에 대한 피치 PI 제어기의 계단응답 고찰)

  • Lim, Chae Wook
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.1
    • /
    • pp.59-64
    • /
    • 2015
  • The pitch control system in wind turbines becomes more and more important as the wind turbines are larger in multi-MW size. PI controller has been applied in most pitch controllers and it has been known that gain-scheduling is essential for pitch control of wind turbines. A demo model of 2 MW wind turbine which represents the whole dynamics of wind turbine including dynamic behaviors of blade, tower and rotational shaft is given in the commercial Bladed S/W for real wind turbines. In this paper, some results on step responses of the pitch PI controller and effectiveness of gain-scheduled pitch PI controller are presented through the Bladed S/W for the 2 MW wind turbine.

Speech Signal Processing using Pitch Synchronous Multi-Spectra and DSP System Design in Cochlear Implant (피치동기 다중 스펙트럼을 이용한 청각보철장치의 음성신호처리 및 DSP 시스템 설계)

  • Shin, J. I.;Park, S. J.;Shin, D. K.;Lee, J. H.;Park, S. H.
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.4
    • /
    • pp.495-502
    • /
    • 1999
  • We propose efficient speech signal processing algorithms and a system for cochlear implant in this paper. The outer and the middle car which perform amplifying, lowpass filtering and AGC, are modeled by an analog system, and the inner ear acting as a time-delayed multi filter and the transducer is implemented by the DSP circuit which enables real-time processing. Especially, the basilar membrane characteristic of the inner ear is modeled by a nonlinear filter bank, and then tonotopy and periodicity of the auditory system is satisfied by using a pitch-synchronous multi-spectra(PSMS) method. Moreover, most of the speech processing is performed by S/W so the system can be easily modified. And as our program is written in C-language, it can be easily transplanted to the system using other processors.

  • PDF

Fabrication and evaluation of microstructural evolution and critical property of twisted Bi-2223 superconductor tape (Twisting된 Bi-2223 선재의 제조, 미세조직 관찰 및 임계 특성평가)

  • 임준형;지봉기;박형상;주진호;장미혜;고태국;이상진;하홍수;오상수
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.3
    • /
    • pp.241-246
    • /
    • 2000
  • We fabricated Bi-2223 multi-filaments superconductor tape and evaluated the effect of twisting on the microstructural evolution and critical current. Twist pitches of the tapes are in the range of 70- 8mm and uniformly deformed. It was observed that grain size and the degree of texture decreased as decreasing pitch probably due to the formation of the irregular interface between Ag and filaments. In addition critical current of the tapes decreased to 6.5 A with decreasing pitch to 8mm, showing 48% of degradation compared to the untwisted tapes decreased to 6.5 A with decreasing pitch to 8mm, showing 48% of degradation compared to the untwisted tape(12.5 A). These reduction of critical current may be related to the interface irregularity smaller grain size worse texture and the presence of cracks due to the induced strain during twisting processing.

  • PDF

Automatic Recognition of Pitch Accents Using Time-Delay Recurrent Neural Network (시간지연 회귀 신경회로망을 이용한 피치 악센트 인식)

  • Kim, Sung-Suk;Kim, Chul;Lee, Wan-Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.4E
    • /
    • pp.112-119
    • /
    • 2004
  • This paper presents a method for the automatic recognition of pitch accents with no prior knowledge about the phonetic content of the signal (no knowledge of word or phoneme boundaries or of phoneme labels). The recognition algorithm used in this paper is a time-delay recurrent neural network (TDRNN). A TDRNN is a neural network classier with two different representations of dynamic context: delayed input nodes allow the representation of an explicit trajectory F0(t), while recurrent nodes provide long-term context information that can be used to normalize the input F0 trajectory. Performance of the TDRNN is compared to the performance of a MLP (multi-layer perceptron) and an HMM (Hidden Markov Model) on the same task. The TDRNN shows the correct recognition of $91.9{\%}\;of\;pitch\;events\;and\;91.0{\%}$ of pitch non-events, for an average accuracy of $91.5{\%}$ over both pitch events and non-events. The MLP with contextual input exhibits $85.8{\%},\;85.5{\%},\;and\;85.6{\%}$ recognition accuracy respectively, while the HMM shows the correct recognition of $36.8{\%}\;of\;pitch\;events\;and\;87.3{\%}$ of pitch non-events, for an average accuracy of $62.2{\%}$ over both pitch events and non-events. These results suggest that the TDRNN architecture is useful for the automatic recognition of pitch accents.

Evaluation of dose delivery accuracy due to variation in pitch and roll (세기변조방사선치료에서 Pitch와 Roll 변화에 따른 선량전달 정확성 평가)

  • Jeong, Chang Young;Bae, Sun Myung;Lee, Dong Hyung;Min, Soon Ki;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.239-245
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the pitch and roll rotational setup error with 6D robotic couch in Intensity Modulated Radiation Therapy (IMRT) for pelvic region in patients. Materials and Methods : Trilogy(Varian, USA) and 6D robotic couch(ProturaTM 1.4, CIVCO, USA) were used to measure and analyze the rotational setup error of 14 patients (157 setup cases) for pelvic region. The total 157 Images(CBCT 78, Radiography 79) were used to calculate the mean value and the incidence of pitch and roll rotational setup error with Microsoft Office Excel 2007. The measured data (3 mm, 3%) at the reference angle ($0^{\circ}$) without couch rotation of pitch and roll direction was compared to the others at different pitch and roll angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$, $2.5^{\circ}$) to verify the accuracy of dose delivery by using 2D array ionization chamber (I'mRT Matrixx, IBA Dosimetry, Germany) and MultiCube Phantom(IBA Dosimetry, Germany). Result from the data, gamma index was evaluated. Results : The mean values of pitch and roll rotational setup error were $0.9^{\circ}{\pm}0.7$, $0.5^{\circ}{\pm}0.6$. The maximum values of them were $2.8^{\circ}$, $2.0^{\circ}$. All of the minimum values were zero. The mean values of gamma pass rate at four different pitch angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$, $2.5^{\circ}$) were 97.75%, 96.65%, 94.38% and 90.91%. The mean values of gamma pass rate at four different roll angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$, $2.5^{\circ}$) were 93.68%, 93.05%, 87.77% and 84.96%. when the same angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$) of pitch and roll were applied simultaneously, The mean values of each angle were 94.90%, 92.37% and 87.88%, respectively. Conclusion : As a result of this study, it was able to recognize that the accuracy of dose delivered is lowered gradually as pitch and roll increases. In order to increase the accuracy of delivered dose, therefore, it is recommended to perform IGRT or correct patient's position in the pitch and roll direction, to improve the quality of treatment.