• 제목/요약/키워드: motion-direction

검색결과 1,420건 처리시간 0.029초

요추 신전 자세에서 야구, 축구 선수 및 일반대학생의 커플모션 연구 (A Study of Coupled Motion of Lumbar Spine in Extended Posture in Football, Baseball Players and General Students)

  • 문옥곤;정한신
    • 대한통합의학회지
    • /
    • 제1권3호
    • /
    • pp.29-35
    • /
    • 2013
  • Purpose : To offer coupled motion caused by sidebending in the extension postures in lumbar spine in the football, baseball players and general students. Method : Coupled motion were analysed by three dimensional motion analyser in the sitting position during lateral bending. Result : Regardless of the direction of sidebending at L1-L3, L5-S2 in the extension posture of the lumbar spine, the direction of coupled motion in the baseball and football players were opposite to the direction of sidebending but the direction of coupled motion was same at L3-L5. while, the direction of sidebending at L1-L3, L3-L5 in the extension posture of the lumbar spine, the direction of coupled motion in the general students were same to the direction of sidebending but, the direction of coupled motion was opposite direction at L5-S2. Conclusion : we found a difference of coupled motion between athletes and non-athletes.

움직임 방향 치우침 특성을 이용한 십자형 다이아몬드 탐색 (Cross Diamond Search Using Motion Direction Biased Characteristics)

  • 류권열
    • 한국정보통신학회논문지
    • /
    • 제13권8호
    • /
    • pp.1527-1533
    • /
    • 2009
  • 본 논문에서는 MVP 분포의 움직임 방향 치우침 특성을 이용한 방향성 탐색 패턴을 디자인하고, 탐색점의 이동 방향에 따라 탐색 패턴을 적응적으로 변화시키는 방향 적응적 십자형 다이아몬드 탐색 방법을 제안 한다. 제안한 방법은 이웃 매크로 블록으로부터 모션 벡터를 예측하고, 예측한 모션 벡터를 이용하여 초기 움직임 방향을 설정 한다. 탐색 과정에서 BMP의 이동 방향에 따라 제안한 탐색 패턴을 적응적으로 변화시킴으로써 탐색 효율을 향상시킨다. 실험 결과, 제안한 방법 은 움직임 추정에 소요되는 계산량을 기존의 십자형 다이아몬드 탐색에 비해 $0.43%{\sim}1.76%$ 감소시킴으로써 고속 움직임 추정이 가능함을 알 수 있었다.

동일한 움직임 벡터들의 방향과 크기를 고려한 프레임율 증가기법 (Frame Rate Up-Conversion Considering The Direction and Magnitude of Identical Motion Vectors)

  • 박종근;정제창
    • 방송공학회논문지
    • /
    • 제20권6호
    • /
    • pp.880-887
    • /
    • 2015
  • 본 논문은 EBME(Extended Bilateral Motion Estimation) 알고리듬에서 동일한 움직임 벡터들의 방향과 크기를 고려한 알고리듬을 제안하였다. EBME는 BME(Bilateral Motion Estimation)보다 높은 연산량을 요구하기 때문에 프레임 내의 x, y방향 각각의 평균 움직임 벡터크기를 이용하여 동적프레임과 정적프레임을 판단하고, EBME 수행여부를 판단하여 연산량을 줄인다. 또한 동일한 움직임 벡터들의 방향과 크기를 비교하여 MVS(Motion Vector Smoothing)단계 수행여부를 판단함으로써 연산량을 줄인다. 제안하는 알고리듬을 적용한 실험 결과 기존의 EBME 알고리듬에 비해 수행시간은 단축되고 PSNR(Peak Signal to Noise Ratio)은 향상 되었다.

Analysis of Lumbar Spine Load during Golf Swing in Pro. Golfer

  • Park, Sung-Kyu;Cho, Woong;An, Ho-Jung
    • 국제물리치료학회지
    • /
    • 제1권2호
    • /
    • pp.162-168
    • /
    • 2010
  • Low back pain is a common phenomenon among the golfers. In an attempt to understand low back pain, the kinematic changes and golf swing motion analysis has been performed to focus on lumbar spine in pro. golfers. According to the swing pattern, significant variations of the lumbar joint forces and loads has related with muscles activities so the motion analysis of lumbar spine were discussed. The purpose of this study was to analyze motion of lumbar spine and it was to compare joint force during golf swing in pro. golfers. The swing motion of the subjects was tracked using a 3D motion analysis system by Motion Analysis Ltd. and SIMM software. The angle changes of lumbar spine rapidly in vx direction during the top back swing and the finish and in vy direction during the follow through and in vz direction during the down swing and the impact(Subject A). The angle changes of lumbar spine rapidly in vx direction during the top back swing and in vy direction during the down swing, the impact and the follow through and in vz direction during the down swing(Subject B). In conclusion, subject A and B both show sudden angle changes between 1st-3rd lumbar spine and 4th-5th lumbar spine during the stage from address to top back swing which caused by over upper body twisting.

  • PDF

승용 자동차 주요 조종장치의 스테레오타입 조사 (Investigation of stereotypes for principal controls in passenger cars)

  • 기도형
    • 대한안전경영과학회지
    • /
    • 제14권2호
    • /
    • pp.35-40
    • /
    • 2012
  • The aims of this study are to investigate stereotypes of motion-direction and real motion-directions for seven principal controls in passenger cars, and to compare the stereotypes and real motion-directions for the controls. The stereotypes were obtained by using questionnaire survey, in which 385 subjects participated. The real motion-direction data were gathered for 64 passenger cars including RVs and SUVs. The results showed that while there are dominant motion-directions for head light, door key and door lock controls, dominant motion-directions are not found for other controls investigated in this study. The stereotypes of motion-directions for seven controls obtained in this study were much different from those of the real data. Furthermore, the stereotypes for wiper, head light and high beam controls based on the questionnaire survey were opposite to the real motion-directions.

Effectiveness of a Turbo Direction Change for Reduction of Motion Artifact in Magnetic Resonance Enterography

  • Choi, Kwan-Woo;Son, Soon-Yong;Jeong, Mi-Ae
    • Journal of Magnetics
    • /
    • 제21권3호
    • /
    • pp.421-424
    • /
    • 2016
  • The purpose of this study is to evaluate an effectiveness of switching turbo direction to improve motion artifacts of small bowels and aorta. From June to October 2015, 60 patients suspected of having Crohn's disease were enrolled. The MR Enterography scans were performed using same protocol other than the turbo direction: with the Z phase encoding (group A) and with Y phase encoding (group B). Qualitative analysis of each group was performed to evaluate the effectiveness of switching turbo direction from Z to Y. As a result, the 5-point Likert scale for paired observers were $2.33{\pm}0.88$ for group A and $3.80{\pm}0.85$ for group B on dynamic contrast enhanced coronal images. In conclusion, group B is proved to be superior to group A and can lessen the motion artifacts derived from phase shifts.

Quantitative Evaluation of an Intuitive Teaching Method for Industrial Robot Using a Force/Moment Direction Sensor

  • Park, Myoung-Hwan;Lee, Woo-Won
    • International Journal of Control, Automation, and Systems
    • /
    • 제1권3호
    • /
    • pp.395-400
    • /
    • 2003
  • A quantitative performance evaluation of a robot teaching method using a force/moment direction sensor is presented. The performance of the teaching method using the force/moment direction sensor is compared with the conventional teaching pendant method. Two types of teaching tasks were designed and the teaching times required to complete the teaching tasks were measured and compared. Task A requires a teaching motion that involves four degrees of freedom motion. Task B requires a teaching motion that involves six degrees of freedom motion. It was found that, by using the force/moment direction sensor method, the teaching times were reduced by 25% for Task A and 45% for Task B compared to the teaching pendant method.

오차보정을 위한 초정밀 테이블의 5 자유도 운동오차 측정 (Measurement of 5 DOF Motion Errors in the Ultra Precision Feed Tables for Error Compensation)

  • 오윤진;박천홍;이득우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.672-676
    • /
    • 2004
  • In this paper, measuring system of 5 DOF motion errors are proposed using two capacitive type sensor, a straight edge and a laser interfoerometer. Yawing error and pitching error are measured using the laser interferometer, and rolling error is measured by the reversal method using a capacitive type sensor. Linear motion errors of horizontal and vertical direction are measured using the sequential two point method. In this case, influence of angular motion errors is compensated using the previously measured angular motion errors. In the horizontal direction, measuring accuracy is within 0.05 $\mu$m and 0.27 arcsec, and in the vertical direction, it is within 0.15 $\mu$m and 0.5 arcsec. From these results, it is confirmed that the proposed measureing system is very effective to the measurement of 5 DOF motion errors in the ultra precision feed tables.

  • PDF

촬상단면내의 MRI 체동 아티팩트의 제거 (Cancellation of MRI Motion Artifact in Image Plane)

  • 김응규;권영도
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.631-634
    • /
    • 1999
  • In this work, a new algorithm for canceling MRI artifact in the image plane is presented. In the conventional approach, the motions in the X(readout) direction and Y(the phase encoding) direction are estimated simultaneously. However, the feature of each X and Y directional motion is different. First, we notice that the X directional motion corresponds to a shift of the X directional spectrum of the MRI signal, and the non zero area of the spectrum just corresponds to X axis projected area of the density function. So the motion is estimated by tracing the edges of the spectrum, and the X directional motion is canceled by shifting the spectrum in inverse direction. Next, the Y directional motion is canceled using a new constraint, with which the motion component and the true image component can be separated. This algorithm is shown to be effective by simulations.

  • PDF

지구 중력장 내에서 성립하는 운동 상태 방정식의 해를 구하기 위한 벡터의 스칼라 프로덕트 응용 (Application of Vector Scalar Product to Solve the Kinematic Equations in the Earth's Gravitational Field)

  • 엄기홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제17권6호
    • /
    • pp.217-222
    • /
    • 2017
  • 지구 중력장 내에 위치한 물체는 연직 아래 방향의 힘을 받고 있다. 중력장 내에서 물체의 운동을 기술하기 위하여 운동상태 방정식을 이용한다. 자유 낙하하는 물체를 해석할 때 기준 방향은 연직 하방을 +y으로, 연직위로 던져 올린 물체를 해석할 때 기준방향은 연직상방을 +y으로, 연직 아래로 던져 내린 물체를 해석할 때, 기준 방향은 연직 하방을 +y으로 선택하여 해석함이 일반적이다. 이 논문에서는 두 벡터의 스칼라 곱 (즉, 도트 곱)을 이용하여 연직 상방 또는 하방 두 경우를 방향으로 선택하여 구성한 벡터 운동 상태 방정식(vector kinematics equations)을 해석의 결과가 서로 일치함을 제시한다. 두 벡터의 스칼라 곱 (즉, 도트 곱)을 이용하여 물체의 상태 방정식를 해석한 예는 선행 연구에서 거의 찾아볼 수가 없다. 이 결과를 이용하면, 수평면의 방향 또는 빗각을 이루는 방향의 초속도로 던져 올리거나 던져 내린 물체의 운동 상태를 해석하기 위하여 연직 기준 방향을 상방 또는 하방으로 임의 선택할 수가 있다.