• Title/Summary/Keyword: mechanical examination

Search Result 448, Processing Time 0.023 seconds

항공기용 초고장력강(300M) 부품의 가공변질층과 응력부식균열에 관한 연구 (A Study of the Affected Layer and Stress Corrosion Crack of Ultra-high-strength Steel (300M) for Aircraft Parts)

  • 안진우;김태환
    • 한국기계가공학회지
    • /
    • 제19권4호
    • /
    • pp.1-8
    • /
    • 2020
  • Mechanical components that support structures in aerospace and power generation industries require high-strength materials. Particularly, in the aerospace industry, aluminum alloys, titanium alloys, and composite materials are increasingly used due to their high maneuverability and durability to withstand low temperature extreme environments; however, ultra-high-strength steel is still used in key components under heavy loads such as landing gears. In this paper, the fault cause analysis and troubleshooting of aircraft parts made of ultra-high-strength steel (300M) broken during normal operation are described. To identify the cause of the defect, a temporary inspection of the same aircraft was performed, and material testing, non-destructive inspection, microstructure examination, and fracture area inspection of the damaged parts were performed. Fracture analysis results showed that a crack in the shape of a branch developed from the tool mark in the direction of the intergranular strain. Based on the results, the cause of fracture was confirmed to be stress corrosion.

원전 ISI UT 자동 결함평가 및 판정 모듈 개발 (Development of ISI UT Auto Flaw Evaluation and Acceptance Module of Nuclear Power Plants)

  • 박익근;박은수;김현묵;김정석;엄병국;이종포
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.212-218
    • /
    • 2000
  • The importance and role of pre-/in-service inspection(PSI/ISI) for nuclear power plant(NPP) components are intimately related to plant design, safety, reliability, operation, etc. In this paper, for an effective and efficient management of large amounts of PSI/ISI data in NPPs, an intelligent database program(WS-IDPIN) for PSI/ISI data management of NPP was developed. WS-IDPIN program enables the prompt extraction of previously conducted PSI/ISI conditions and results so that the time-consuming data management, painstaking data processing and analysis in the past are avoided. Furthermore, development of ISI UT auto flaw evaluation and acceptance module based on ASME Code Sec. XI were presented. This module can be used for any angle beam examination from flat plate to spherical shapes as selected by the proper azimuthal angle. This program can be further developed as a unique PSI/ISI data management expert system.

  • PDF

Concomitant Right Ventricular Outflow Tract Cryoablation during Pulmonary Valve Replacement in a Patient with Tetralogy of Fallot

  • Shin, Hong Ju;Song, Seunghwan;Shin, Yu Rim;Park, Han Ki;Park, Young Hwan
    • Journal of Chest Surgery
    • /
    • 제50권1호
    • /
    • pp.41-43
    • /
    • 2017
  • A 38-year-old female patient with a history of tetralogy of Fallot repair at 10 years of age underwent pulmonary valve replacement with a mechanical prosthesis, tricuspid annuloplasty, and right ventricular outflow tract cryoablation due to pulmonary regurgitation, tricuspid regurgitation, and multiple premature ventricular contractions with sustained ventricular tachycardia. After surgery, she had an uneventful postoperative course with arrhythmia monitoring. She was discharged without incident, and a follow-up Holter examination showed a decrease in the number of ventricular ectopic beats from 702 to 41.

이상근 증후군 치험 1례 (A Case Report of the Piriformis Syndrome Treated by Caudal Steroid and Local Anesthetic)

  • 정창영;윤명하;임웅모;김별아
    • The Korean Journal of Pain
    • /
    • 제8권1호
    • /
    • pp.149-151
    • /
    • 1995
  • Piriformis syndrome is a syndrome of low back and leg radiating pain thought to be due to a chronic contracture of the piriformis muscle that causes irritation of the sciatic nerve. The piriformis muscle is a flat pyramidal muscle, an external rotator and abductor of the hip, originating from the front of the sacrum and inner aspect of the sacroiliac joint, then passes laterally out of the sciatic notch to attach posteriorly to the greater trochanter of the femur, the sciatic nerve passes between the two bellies of the muscle. Mechanical irritation of the sciatic nerve by an inflammatory reaction of the piriformis muscle and its fascia at this pelvic level causes pain to radiate in the dermatomal regions of the nerve roots similar to that disk entrapment. diagnosis of piriformis syndrome is made primary on the basis of history and clinical examination. The incidence is considerably higher in women, with the reported ratio of women to men of 6:1. These patients frequently present with associated symptoms of pelvic pain and/or dyspareunia. Symptoms are usually unilateral but occasionally be bilateral. We had a 42 year-old woman patient with low back and left leg radiating pain and dyspareunia treated by caudal steroid and local anesthetic.

  • PDF

Remotely Operated Decontamination Systems for Use in DFDF

  • Kim, Kiho;Park, Jangjin;Myungseung Yang
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2003년도 가을 학술논문집
    • /
    • pp.438-446
    • /
    • 2003
  • This paper presents the development of the remotely operated decontamination systems for use in a highly radioactive zone of the DUPIC Fuel Development facility of the Irradiated Material Examination Facility at the Korea Atomic Energy Research Institute. The remotely operated decontamination systems were designed to completely eliminate human interaction with hazardous radioactive contaminants. These decontamination systems are mainly classified into three systems depending on the task environment - a fabrication equipment decontamination system, a hot-cell floor decontamination system, and an isolation room floor decontamination system. A decontamination system for contaminated fabrication equipment utilizes dry ice pellet blasting method to decontaminate contaminated surface of the equipment. The decontamination systems for the hot-cell floor and isolation room floor employ a vacuum cleaning method to decontaminate the contaminated floor and collect loose dry spent nuclear fuel debris and other radioactive waste placed on the floor. The human operator from the out-of-cell performs a series of decontamination tasks remotely by manipulating decontamination systems located in-cell via a handcontroller with the aid of vision feedback information. The environmental, functional and mechanical design considerations, control system and capabilities of the remotely operated decontamination systems at a high radioactive environment are also described.

  • PDF

시운전 시험을 통한 한국형 고속열차의 승차감 변화추세에 관한 연구 (Examination on the variation of ride comfort for korean high speed train through on-line test)

  • 김영국;목진용;김석원;박찬경;김기환;박태원
    • 센서학회지
    • /
    • 제14권3호
    • /
    • pp.144-149
    • /
    • 2005
  • In this paper, we introduce the variation of ride characteristics for HSR 350x(Korea High Speed Train project) through on-line test during about 3 years. The concept of term "ride comfort" is equivocal. Generally it is evaluated as the vehicle vibration. The ride comfort for HSR 350x has been assessed by statistical method according to UIC 513R. The testing results show that HSR 350x has no problems from the viewpoint of the comfort ride on the high speed line and conventional line and that 1st and 2nd suspensions play an important role in the ride characteristics for high speed train.

Influence Study of Aluminum Dross on Polypropylene Matrix-Polymer Composite Material Properties

  • Kongchatree, Khanob;Yaemphuan, Paiboon;Kaewwichit, Jesada;Roybang, Waraporn;Kimapong, Kittipong
    • International Journal of Advanced Culture Technology
    • /
    • 제3권1호
    • /
    • pp.138-144
    • /
    • 2015
  • This paper is aimed to study the influence of aluminium dross from Thai aluminum casting factory on polypropylene matrix-polymer composite material properties. The summarized experimental results are as follows. An increase in the amount of aluminum dross polymer composite material affected to increase hardness, modulus of elasticity and abrasion resistance. However, the increase of the aluminum dross had no effects to change the yield strength and the melting temperature of the polymer composite material. The aluminum dross also affected to form the crystallinity at $117-122^{\circ}C$ and directly increased the rigid property of the composite materials. The microstructure examination revealed that the aluminum dross was located in a polymer matrix and affected to increase the dark colour of the polymer composite material.

설문과 비침습적 검사를 통하여 심혈관계 건강 정도를 알려주는 심혈관지수의 개발 (Development of a Cardiovascular Index That Estimates Cardiovascular Health Degree by Survey and Noninvasive Examination)

  • 이종선;정인욱
    • 한국정밀공학회지
    • /
    • 제31권5호
    • /
    • pp.459-466
    • /
    • 2014
  • An index was developed that estimates cardiovascular health degree with easily available physiological information such as survey and noninvasive measurement. The survey score was calculated by utilizing questions related to personal disease history, self-feeling, and management state. The measurement score was calculated using physiological parameters such as blood pressure, accelerated plethysmograph(APG), and heart rate variability(HRV), and augmentation index(AI). In order to evaluate effectiveness of the cardiovascular index and modify weighting factors used in each item, a clinical trial was done in a general hospital. The cardiovascular index showed a clear correlation of 0.685 with the doctor's score on the cardiovascular health degree. The correlation between the self-estimated score and doctor's score was as low as 0.217. The large gap between these two scores demonstrated necessity of more objective tools like the cardiovascular index. The cardiovascular score showed a significant difference between normal persons and patients suffering hypertension or diabetes. (p=0.000).

중량물 설치 시 이동식 크레인 기종선정에 관한 연구 (HA Study on the Selection of Mobile Crane Model for Heavy Equipments Installation)

  • 정재복;유호선
    • 플랜트 저널
    • /
    • 제8권2호
    • /
    • pp.59-69
    • /
    • 2012
  • This study focuses on avoiding the failures from the wrong selections by experiences as simulation programs is not available, and suggests the methods which effectively select the alternatives when the selected model is not appropriate for the original plan. First, CC8800-1K of DEMAG has the longest boom whose length is 216 m at the maximum. The combination of the boom is feasible to second level except for MANITIWOC M 2250 (M-1200 RINGER) which is possible to third level. Second, the angle of boom is from 20 degrees to 82 degrees. Suitable angle to work is in the 55-78 degrees. The working load of crawler type and hydraulic one to be applied is 75-85% in the critical loads capacity. As increasing operating radius, crawler type is a favorable position over hydraulic one. Lastly, related problems were verified through examination by suggestions for the design of the selection methods for the case analysis. The major problems are stemming from the selection based on its experiences, unreasonable demand for the existing facility and repeated selections by the designer who accumulates his experiences via same or similar projects.

  • PDF

CMP (Chemical Mechanical Polishing) characteristics of langasite single crystals for SAW filter applications

  • Jang, Min-Chul;An, Jin-Ho;Kim, Jong-Cheol;Auh, Keun-Ho
    • 한국결정성장학회지
    • /
    • 제10권4호
    • /
    • pp.309-317
    • /
    • 2000
  • Langasite is a promising new piezoelectric material for SAW filter application. Little was known until recently about the methods needed to mechanically polish and chemically polish/etch this material. In this experiment, polishing, slurry chemistry and chemical wet etching for langasite is described. Conventional quartz and LN ($LiNbO_3$) polishing methods did not produce satisfactory polished surfaces, and polishing with a colloidal silica slurries has shown to be most effective. The optimum condition was investigated by changing the slurry chemistry. As the planarization effect is very important in SAW filter applications, the examination of the effective particle number effect and the particle size effect was carried out. Z-cut langasite surface which had been polished with the colloidal silica slurries was etched in a variety of etchants. Conventional quartz etchants destroyed the polished surface. Other etchants formed a thin film on the surfaces. In this experiment, the reaction between langasite and a few etching solution was analysed. And an appropriate selective etchant solution for analyzing the defects was synthesized.

  • PDF