• Title/Summary/Keyword: low magnetic field

Search Result 797, Processing Time 0.027 seconds

Effect of Bias Magnetic Field on Magnetoelectric Characteristics in Magnetostrictive/Piezoelectric Laminate Composites

  • Chen, Lei;Luo, Yulin
    • Journal of Magnetics
    • /
    • v.20 no.4
    • /
    • pp.347-352
    • /
    • 2015
  • The magnetoelectric (ME) characteristics for Terfenol-D/PZT laminate composite dependence on bias magnetic field is investigated. At low frequency, ME response is determined by the piezomagnetic coefficient $d_{33,m}$ and the elastic compliance $s_{33}^H$ of magnetostrictive material, $d_{33,m}$ and $s_{33}^H$ for Terfenol-D are inherently nonlinear and dependent on $H_{dc}$, leading to the influence of $H_{dc}$ on low-frequency ME voltage coefficient. At resonance, the mechanical quality factor $Q_m$ dependences on $H_{dc}$ results in the differences between the low-frequency and resonant ME voltage coefficient with $H_{dc}$. In terms of ${\Delta}E$ effect, the resonant frequency shift is derived with respect to the bias magnetic field. Considering the nonlinear effect of magnetostrictive material and $Q_m$ dependence on $H_{dc}$c, it predicts the low-frequency and resonant ME voltage coefficients as a function of the dc bias magnetic field. A good agreement between the theoretical results and experimental data is obtained and it is found that ME characteristics dependence on $H_{dc}$ are mainly influenced by the nonlinear effect of magnetostrictive material.

Construction of a Low Magnetic Field Standard System Using a Precision Solenoid (정밀솔레노이드를 사용한 저자장 표준시스템 제작)

  • 박포규;손대락;우병칠;김창석
    • Journal of the Korean Magnetics Society
    • /
    • v.2 no.2
    • /
    • pp.150-155
    • /
    • 1992
  • The low magnetic field standard below 1 mT with resolution of 100 nT has been established for the calibration and testing of low field magnetometers. A precision single layered solenoid, which is made of quartz tube and bare copper wire, was constructed in order to generate a precise magnetic field. To improve the field homogeneity in the solenoid, three-current method was employed. The injected current and injection points on the solenoid were optimized by computer simulation. The magnetic field uncertainty in the solenoid was 0.1 % and 0.01 % in the range of ${\pm}5\;cm$ from the center for a single and three-current methods respectively. We also constructed a testing system for the dynamic properties of low field magnetometers.

  • PDF

Effect of Magnetic Field Annealing on Microstructure and Magnetic Properties of FeCuNbSiB Nanocrystalline Magnetic Core with High Inductance

  • Fan, Xingdu;Zhu, Fangliang;Wang, Qianqian;Jiang, Mufeng;Shen, Baolong
    • Applied Microscopy
    • /
    • v.47 no.1
    • /
    • pp.29-35
    • /
    • 2017
  • Transverse magnetic field annealing (TFA) was carried out on $Fe_{73.5}Cu_1Nb_3Si_{15.5}B_7$ nano-crystalline magnetic core with the aim at decreasing coercivity ($H_c$) while keeping high inductance ($L_s$). The magnetic field generated by direct current (DC) was applied on the magnetic core during different selected annealing stages and it was proved that the nanocrystalline magnetic core achieved lowest $H_c$ when applying transverse field during the whole annealing process (TFA1). Although the microstructure and crystallization degree of the nanocrystalline magnetic core exhibited no obvious difference after TFA1 compared to no field annealing, the TFA1 sample showed a more uniform nanostructure with a smaller mean square deviation of grain size distribution. $H_c$ of the nanocrystalline magnetic core annealed under TFA1 decreased along with the increasing magnetic field. As a result, the certain size nanocrystalline magnetic core with low $H_c$ of 0.6 A/m, low core loss (W at 20 kHz) of 1.6 W/kg under flux density of 0.2 T and high $L_s$ of $13.8{\mu}H$ were obtained after TFA1 with the DC intensity of 140 A. The combination of high $L_s$ with excellent magnetic properties promised this nanocrystalline alloy an outstanding economical application in high frequency transformers.

Development of a Magnetic-field Stimulation System for Cell Cultures in situ: Simulation by Finite Element Analysis

  • Dominguez, G.;Arias, S.;Reyes, Jose L.;Rogeli, Pablo
    • Journal of Magnetics
    • /
    • v.22 no.2
    • /
    • pp.326-332
    • /
    • 2017
  • The effects of exposure to an extremely low-frequency magnetic field (25 Hz 20G) on animal cells have been studied. In some reports, stimulation was performed for fixed frequency and variations in magnitude; however, animal-cell experiments have established that both parameters play an important role. The present work undertook the modeling, simulation, and development of a uniform-magnetic-field generation system with variable frequency and stimulation intensity (0-60 Hz, 1-25G) for experimentation with cell cultures in situ. The results showed a coefficient of variation less than 1 % of the magnetic-field dispersion at the working volume, which is consistent with the corresponding simulation results demonstrating a uniform magnetic field. On the other hand, long-term tests during the characterization process indicated that increments of only $0.4^{\circ}C$ in the working volume temperature will not be an interfering factor when experiments are carried out in in situ cell cultures.

Study on the Magnetic Shield Effect of Carbon-based Materials at Extremely Low Frequency (탄소계 소재를 이용한 극저주파 영역에서의 자기 차폐효과 연구)

  • Oh, Seong Moon;Kang, Dong Su;Lee, Sang Min;Baek, Un Gyeong;Roh, Jae Seung
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.15-20
    • /
    • 2015
  • To examine the magnetic shielding effect for carbon-based materials at extremely low frequencies (60 Hz), two types of carbon black (Super-P and Denka Black) and a natural graphite (HC-198) were mixed into organic binder at 10 wt.% to produce a coating solution, and a powder coating with varying thickness was applied on an aluminum disk measuring 88 mm in radius. A device was developed to measure the sheielding effect at extremely low frequencies. A closed circuit was achieved by connecting a transformer and a resistor. The applied voltage was fixed at 65 V, and the magnetic field was measured to being the range of 4.95~5.10 mG. Depending on the thickness of the coating layer, the magnetic field showed a decreasing trend. The maximum decrease in the magnetic field of 38.3% was measured when natural graphite was coated with specimens averaging $455{\mu}m$. This study confirmed that carbon-based materials enable magnetic shielding at extremely low frequencies, and that the magnetic shielding effect can be enhanced by varying the coating thickness.

Magnetoelectric Characteristics on Layered Ni-PZT-Ni, Co, Fe Composites for Magnetic Field Sensor (자기센서용 Ni-PZT-Ni, Co, Fe 적층구조 소자의 ME 특성)

  • Ryu, Ji-Goo;Jeon, Seong-Jeub
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.2
    • /
    • pp.92-98
    • /
    • 2015
  • The magnetoelectric characteristics on layered Ni-PZT-Ni, Co, Fe composites by epoxy bonding for magnetic field sensor were investigated in the low-frequency range. The ME coefficient of Ni-PZT-Ni, Ni-PZT-Co and Ni-PZT-Fe composites reaches a maximum of $200mV/cm{\cdot}Oe$ at $H_{dc}=110$ Oe, $106mV/cm{\cdot}Oe$ at $H_{dc}=90$ Oe and $87mV/cm{\cdot}Oe$ at $H_{dc}=160$ Oe, respectively. A trend of ME charateristics on Ni-PZT-Co, Ni-PZT-Fe composites was similar to that of Ni-PZT-Ni composites. The ME output voltage shows linearly proportional to ac field $H_{ac}$ and is about 0~150 mV at $H_{ac}$=0~7 Oe and f=110 Hz in the typical Ni-PZT-Ni sample. The frequency shift effect due to the load resistance $R_L$ shows that the frequency range for magnetic field sensor application can be modulated with appropriate load resistance $R_L$. This sample will allow for a low-magnetic ac field sensor in the low-frequency (near f=110 Hz).

A numerical study on the effects of the asymmetric cusp magnetic field in 8 inch silicon single crystal growth by Czochralski method (초크랄스키법에 의한 8인치 실리콘 단결정 성장시 비대칭 커스프자장의 영향에 관한 연구)

  • 이승철;정형태;윤종규
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.6 no.1
    • /
    • pp.1-10
    • /
    • 1996
  • A numerical study was conducted on the effects of the cusp magnetic field in 8" silicon single crystal grwoth by Czochralski method. For a damping effects simulation by magnetic field, low reynolds number ${\kappa} - {\varepsilon}$ model was adopted. Symmetrci cusp magnetic field has a effect of damping streamline crystal, is lowerd with the increasing cusp magnetic field intensity. The uniformity of the oxygen concentration was improved. The asymmetirc cusp magnetic field increased the oxygen concentration however, oxygen concentration distribution in the radial direction was remained uniform. Suitable combination of symmetric and asymmetric cusp magnetic fields could give uniform and low oxygen concentration in the axial direction.tion.

  • PDF

Comparative Study of Coupling Factors for Assessment of Low-Frequency Magnetic Field Exposure

  • Shim, Jae-Hoon;Choi, Min-Soo;Jung, Kyu-Jin;Kwon, Jong-Hwa;Byun, Jin-Kyu
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.516-523
    • /
    • 2016
  • In this paper, coupling factors are calculated based on numerical analysis in order to assess various non-uniform low-frequency magnetic field exposure situations. Two types of non-uniform magnetic field sources are considered; circular coil and parallel wires with balanced currents. For each magnetic field source, source current values are determined so that reference magnetic field magnitude can be measured at the specified point on the human model. Various exposure situations are investigated by changing parameters such as the distance between source and human model, radius of circular coil, and the gap between parallel wires. For equivalent human models, prolate spheroid model and simplified human model from IEC 62311 standard are used. The calculated coupling factor values are compared with those obtained by 2D uniform disk human model, and the dependence of coupling factor on the choice of equivalent human model is analyzed.

Design and Implementation of ELF Digital Magnetic Fields Meter (극저주파 디지털 자계 측정기의 설계 및 구현)

  • Im, Jae-Yoo;Hwang, Jung-Hwan;Kim, Won-Ho
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.3
    • /
    • pp.84-88
    • /
    • 2015
  • In this paper, we present that design and implementation of digital extreme-low-frequency (ELF) magnetic meter including wireless monitoring feature. In our lifetime, it is necessary to study how much magnetic field effects to human body. In this paper, we use 3-axis coil-type magnetic sensor, magnetic measurement range is 0.03~10uT and frequency range is 40~180Hz. As magnetic sensor characteristic, frequency loss is occurred that compensated using digital equalize based on DSP processor. Measurement value can be monitored on PC through Wifi communication and measurement error is observed within 6%.

Magnetic Wireless Actuator for Medical Applications

  • Kazushi, Ishiyama;Masahiko, Sendoh;Aya, Yanmazaki;Ken, Ichi Arai
    • Journal of Magnetics
    • /
    • v.8 no.1
    • /
    • pp.74-78
    • /
    • 2003
  • The largest advantage of magnetic micromachine is wireless operation. This advantage makes it suitable for medical micromachine working inside the human body. In the medical field, low invasion treatment is very important From this point of view, very small machines working in the body without power supply cables meet the needs of the medical field. In this paper, we report about magnetic wireless actuators for medical applications.