• 제목/요약/키워드: local L/C

검색결과 333건 처리시간 0.033초

Energy Saving Effect for High Bed Strawberry Using a Crown Heating System (고설 딸기 관부 난방시스템의 에너지 절감 효과)

  • Moon, Jong Pil;Park, Seok Ho;Kwon, Jin Kyung;Kang, Youn Koo;Lee, Jae Han;Kim, Hyung Gweon
    • Journal of Bio-Environment Control
    • /
    • 제28권4호
    • /
    • pp.420-428
    • /
    • 2019
  • This study is the heating energy saving test of the high-bed strawberry crown heating system. The system consists of electric hot water boiler, thermal storage tank, circulation pump, crown heating pipe(white low density polyethylene, diameter 16mm) and a temperature control panel. For crown heating, the hot water pipe was installed as close as possible to the crown part after planting the seedlings and the pipe position was fixed with a horticultural fixing pin. In the local heating type, hot water at $20{\sim}23^{\circ}C$ is stored in the themal tank by using an electric hot water boiler, and crown spot is partially heated at the setting temperature of $13{\sim}15^{\circ}C$ by turning on/off the circulation pump using a temperature sensor for controlling the hot water circulation pump which was installed at the very close to crown of strawberry. The treatment of test zone consisted of space heating $4^{\circ}C$ + crown heating(treatment 1), space heating $8^{\circ}C$(control), space heating $6^{\circ}C$ + crown heating(treatment 2). And strawberries were planted in the number of 980 for each treatment. The heating energy consumption was compared between November 8, 2017 and March 30, 2018. Accumulated power consumption is converted to integrated kerosene consumption. The converted kerosene consumption is 1,320L(100%) for space $8^{\circ}C$ heating, 928L(70.3%) for space $4^{\circ}C$ + crown heating, 1,161L($88^{\circ}C$) for space $6^{\circ}C$ + crown heating). It was analyzed that space $4^{\circ}C$ + pipe heating and space $6^{\circ}C$ + crown heating save heating energy of 29.7% and 12% respectively compared to $8^{\circ}C$ space heating(control).

Evaluation of Purification Capacity of Vegetable Lactobacillus fermentum Culture System in Closed Environmental Waste Water (식물성 유산균 혼합물을 활용한 환경 폐수의 정화능력 평가)

  • Lee, Deuk Sik;Kim, Nam Kyun;Shim, Sooyong;Lee, Dong Jin;Yoon, Won Byong
    • Food Engineering Progress
    • /
    • 제15권1호
    • /
    • pp.22-27
    • /
    • 2011
  • Changes in total nitrogen (T.N.) and total phosphate (T.P.) content in environmental waste water upon the reaction of biological purifying reagents were measured and the reaction rate was evaluated. The purification capacity of two biological purifying reagents composed of vegetable Lactobacillus fermentum (V.L.F.), Saccharomyces cerevisiae(S.C), and Bacillus subtilis(B.S.) were evaluated and compared with that of commercial water purification system operating by local government. After 18days of reaction, the mixture of V.L.F. and S.C. showed dramatic decrease of T.N.(36.21% of the initial value). The mixture of V.L.F., S.C., and B.S. showed faster reaction rate to decrease T.P. compared with that of the mixture of V.L.F. and S.C. The reaction constant of mixture of V.L.F. and S.C. was estimated to be 0.178 $day^{-1}$ by the curve fitting of the data of changes in T.N. during the reaction.

AN IMPROVED GLOBAL WELL-POSEDNESS RESULT FOR THE MODIFIED ZAKHAROV EQUATIONS IN 1-D

  • Soenjaya, Agus L.
    • Communications of the Korean Mathematical Society
    • /
    • 제37권3호
    • /
    • pp.735-748
    • /
    • 2022
  • The global well-posedness for the fourth-order modified Zakharov equations in 1-D, which is a system of PDE in two variables describing interactions between quantum Langmuir and quantum ionacoustic waves is studied. In this paper, it is proven that the system is globally well-posed in (u, n) ∈ L2 × L2 by making use of Bourgain restriction norm method and L2 conservation law in u, and controlling the growth of n via appropriate estimates in the local theory. In particular, this improves on the well-posedness results for this system in [9] to lower regularity.

Fabrication, temperature-dependent local structural and electrical properties of VO2 thin films

  • Jin, Zhenlan;Hwang, In-Hui;Park, Chang-In;Han, Sang-Wook
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.169.2-169.2
    • /
    • 2015
  • $VO_2$ is a well-known a metal-to-insulator-transition (MIT) material, accompanied with a first order structural phase transition near room temperature. Because of the structural phase transition and the MIT occur near a same temperature, there is an ongoing argument whether the MIT is induced by the structural phase transition. $VO_2$ exhibits a relatively weak anti-oxidization ability and can be oxidized to higher-valence oxides (e.g., $V_4$ $O_7$ or $V_2$ $O_5$) when annealed at a high temperature in an oxygen-rich atmosphere. We fabricated $VO_2$ films on $Al_2$ $O_3$ (0001) substrates using a DC magnetron sputtering deposition process with carefully control the $O_2$ percentage in an atmosphere. X-ray diffraction measurements from the films showed only (0l0) peaks with no extra peaks, indicating b-oriented films. The temperature-dependent local structural properties of $VO_2$ films were investigated by using in-situ X-ray absorption fine structure (XAFS) measurements at the V K edge. XAFS revealed that the structural phase transition was occurred nearly $70^{\circ}C$ for heating process and reproducible. Resistance measurements as a function of temperature (R-T) demonstrated that the resistance of $VO_2$ films was changed by a factor of 4 near $75^{\circ}C$ which was higher than $68^{\circ}C$ reported from a $VO_2$ bulk. We will discuss the MIT of $VO_2$ films, comparing with the local structural properties determined by XAFS measurements.

  • PDF

TEM Investigations of Structures and Phase Transitions in Tridymite (투과전자현미경을 이용한 Tridymite의 구조 및 상전이 연구)

  • 김윤중
    • Journal of the Mineralogical Society of Korea
    • /
    • 제15권1호
    • /
    • pp.44-58
    • /
    • 2002
  • A new polymorph of tridymite, an incommensurately modulated phase (IC phase), has been identified. While the symmetry of the IC lattice is same as that of the Ll phase, the geometry of the IC lattice structure is same as the basis of the L3 structure with a different modulation (modulation vector q=0.22 $c*_{H}$;$\lambda$ 37 ). On the other hand, the characteristic curved diffuse diffration observed from the Ll atoms could occur even at room phase suggests that the dynamic disordering of atoms, especially oxygen atoms could occur even at room temperature. The phase transition of Ll to L3 by grinding is gradual but very conspicuous: LllongrightarrowL1+IClongrightarrowIC+L3longrightarrowL3. However, it is revealed that real transition processes of individual grains are directly related to the local stress fields and preexisting microstructures.

Natural Convection Heat Transfer from a Conducting Tube with Two Vertical Axial Fins (2개(個)의 수직(垂直) 평판(平板)핀을 가진 전도관(傳導管)으로 부터의 자연대류(自然對流) 열전달(熱傳達))

  • Chung, H.S.;Lee, C.J.;Kwon, S.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제3권4호
    • /
    • pp.222-230
    • /
    • 1991
  • Conjugate heat transfer by steady laminar natural convection from a conducting tube with two vertical axial fins has been studied by a finite difference numerical procedure under basic conditions; $Ra=10_6$, Pr = 5 and $L_F=0.15$. The maximum local tube Nusselt number appears at ${\theta}=140^{\circ}$ for $L_F=0.06$, at ${\theta}=130^{\circ}$ for $L_F=0.30$ and at ${\theta}=120^{\circ}$ for $L_F=0.30$, $L_F=0.06$, respectively. The maximum mean Nusselt number shows at $L_F=0.18$ for the downward fin and at $L_F=0.12$ for the upward fin. Therefore the optimized fin length is $L_F{\approx}0.15$ under these conditions. At $L_F=0.15$, the mean Nusselt number by increasing Rayleigh number is remarkably increased for downward fin and then is slowly increased except for downward fin, it by increasing Prandtl number is apparently increased at $Pr{\leq}2$, and slightly increased at Pr>2.

  • PDF

The Risks of Transport Documents under L/C Transaction (신용장거래에서 운송서류의 위험요인에 관한 연구)

  • Park, See-Woon
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • 제45권
    • /
    • pp.85-109
    • /
    • 2010
  • L/C provides the exporter and the importer with safe assurance in the exchange of goods for payment in international trade. It involves a number of parties. Although the parties may have confidence in their client, bad faith or ignorance of international banking practice by any of these parties could cause the failure of transaction, which makes international trade a risky business. Most of the risks are found in transport document, which can cause disputes. There are many factors in the risk of transport documents under L/C transaction. One most common risk factor for the beneficiary in all transport documents is even if there is no discrepancy in document, the issuing bank or the applicant refuses to pay or delay payment insisting there is a discrepancy. In some very rare cases, the beneficiary may not get paid due to unfair injunction of the local court of the applicant. For the applicant, most common risk factors are fake bill and fraud. Risks classified according to the sorts of transport documents are as follows. 1. In B/L, payment can be refused because it is regarded as charter party B/L, although there is no real charter party contract. And the applicant can bear the potential risk of the loss or deterioration of cargo through transhipment of the cargo loaded on board in container if transhipment is prohibited without excluding of UCP 600 article 20 (c). 2. In charter party B/L, the applicant may take delivery without paying when charter party B/L is signed by charterer, which can result in a big loss for the beneficiary and the negotiating bank. And risks may arise when cargo is seized because the charterer does not pay the hire. The applicant and the issuing bank are also vulnerable to a risk - Against whom should they file a suit when cargo gets damaged during transportation? 3. In multimodal transport document, which is subject to a conflict because there is a big difference in viewpoints between transport industry and banks, conflicts may also arise when L/C requires ocean B/L and accepts multimodal transport document at the same time, but does not specify the details. 4. In air waybill, where the consignee is not the issuing bank but the applicant, risks may take place to the beneficiary when the applicant takes delivery but refuses to pay asserting minor discrepancies in document. The applicant may also bear the risk when cargo may not be loaded because air waybill is a received bill. Another risk may arise when although the applicant prohibits transhipment without excluding UCP 600 article 23 (c), the cargo may be transhipped, provided that the entire carriage is covered by one and the same air waybill.

  • PDF

A 3-D Vision Sensor Implementation on Multiple DSPs TMS320C31 (다중 TMS320C31 DSP를 사용한 3-D 비젼센서 Implementation)

  • Oksenhendler, V.;Bensrhair, Abdelaziz;Miche, Pierre;Lee, Sang-Goog
    • Journal of Sensor Science and Technology
    • /
    • 제7권2호
    • /
    • pp.124-130
    • /
    • 1998
  • High-speed 3D vision systems are essential for autonomous robot or vehicle control applications. In our study, a stereo vision process has been developed. It consists of three steps : extraction of edges in right and left images, matching corresponding edges and calculation of the 3D map. This process is implemented in a VME 150/40 Imaging Technology vision system. It is a modular system composed by a display, an acquisition, a four Mbytes image frame memory, and three computational cards. Programmable accelerator computational modules are running at 40 MHz and are based on TMS320C31 DSP with a $64{\times}32$ bit instruction cache and two $1024{\times}32$ bit internal RAMs. Each is equipped with 512 Kbytes static RAM, 4 Mbytes image memory, 1 Mbytes flash EEPROM and a serial port. Data transfers and communications between modules are provided by three 8 bit global video bus, and three local configurable pipeline 8 bit video bus. The VME bus is dedicated to system management. Tasks between DSPs are distributed as follows: two DSPs are used to edges detection, one for the right image and the other for the left one. The last processor computes the matching process and the 3D calculation. With $512{\times}512$ pixels images, this sensor generates dense 3D maps at a rate of about 1 Hz depending of the scene complexity. Results can surely be improved by using a special suited multiprocessors cards.

  • PDF

Local structure of transparent flexible amorphous M-In-ZnO semiconductor

  • Son, L.S.;Kim, K.R.;Yang, D.S.;Lee, J.C.;Sung, N.;Lee, J.;Kang, H.J.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.164-164
    • /
    • 2010
  • The impurity doped ZnO has been extensively studied because of its optoelectric properties. GIZO (Ga-In-Zn-O) amorphous oxide semiconductors has been widely used as transparent flexible semiconductor material. Recently, various amorphous transparent semiconductors such as IZO (In-Zn-O), GIZO, and HIZO (Hf-In-Zn-O) were developed. In this work, we examined the local structures of IZO, GIZO, and HIZO. The local coordination structure was investigated by the extended X-ray absorption fine structure. The IZO, GIZO and HIZO thin films ware deposited on the glass substrate with thickness of 400nm by the radio frequency sputtering method. The targets were prepared by the mixture of $In_2O_3$, ZnO and $HfO_2$ powders. The percent ratio of In:Zn in IZO, Ga:In:Zn in GIZO and Hf:In:Zn in HIZO was 45:55, 33:33:33 and 10:35:55, respectively. In this work, we found that IZO, GIZO and HIZO are all amorphous and have a similar local structure. Also, we obtained the bond distances of $d_{Ga-O}=1.85\;{\AA}$, $d_{Zn-O}=1.98\;{\AA}$, $d_{Hf-O}=2.08\;{\AA}$, $d_{In-O}=2.13\;{\AA}$.

  • PDF

Effect of $N_2$ back shielding gas on the property change of GTA weldment (질소 이면보호가스 적용성에 관한 연구)

  • 백광기;안병식
    • Journal of Welding and Joining
    • /
    • 제5권4호
    • /
    • pp.12-21
    • /
    • 1987
  • To investigate the suitability of nitrogen gas as an internal purging gas, various properties of GTA welded joints of duplex, 316L stainless steel, Cu-Ni alloy pipe using nitrogen purging gas were evaluated with reference to onew purged with argon gas. Mechanical properties evaluated by the tensile, bending test, and hardness value of welded joints with nitrogen gas purging did not show any difference those with argon gas. General and local corrosion rates of each welded joint prepared by nitrogen gas purging also showed no difference with those prepared by argon gas. Based on the present test results it is confirmed that nitrogen is a suitable purging gas for GTA welding of stainless steels and nonferrous piping systems, which can be used at lower cost instead of argon.

  • PDF