• Title/Summary/Keyword: light wavelength

Search Result 1,428, Processing Time 0.03 seconds

LABORATORY SIMULATION OF LIGHT SCATTERING FROM REGOLITH ANALOGUES: EFFECT OF POROSITY

  • KAR, AMRITAKSHA;DEB, SANJIB;SEN, A.K.;GUPTA, RANJAN
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.65-67
    • /
    • 2015
  • The surfaces of most atmosphereless solar system objects are referred to as regolith, layers of loosely connected fragmentary debris, produced by meteorite impacts. Measurements of light scattered from such surfaces provides information about the composition and structure of the surface. A suitable way to characterize the scattering properties is to consider how the intensity and polarization of scattered light depends on the particle size, composition, porosity, roughness, wavelength of incident light and the geometry of observation. In the present work, the effect of porosity on bidirectional reflectance as a function of phase angle is studied for alumina powder with grain size of $0.3{\mu}m$ and olivine powder with grain size of $49{\mu}m$ at 543.5 nm. The optical constants of the alumina sample for each porosity were calculated with Maxwell Garnett effective medium theory. On using each of the optical constants of alumina sample in Mie theory with the Hapke model the variation of bidirectional reflectance is obtained as a function of phase angle with porosity as a parameter. Experimental reflectance data are in good agreement the model. For the olivine sample the effect of porosity is studied using Hapke (2008).

Evaluation of green light Emitting diode with p-type GaN interlayer (P형 GaN 중간층이 삽입된 녹색 발광다이오드 특성 평가)

  • Kim, Eunjin;Kim, Jimin;Jang, Soohwan
    • Korean Chemical Engineering Research
    • /
    • v.54 no.2
    • /
    • pp.274-277
    • /
    • 2016
  • Effects of interlayer insertion between multi-quantum well and electron blocking layer of green light emitting diode on diode performances were studied by device simulation. Dependence of Mg doping depth on characteristics of current-voltage, emitting wavelength, leakage current, and external quantum efficiency was investigated, and the optimum diode structure was presented. Device structures with interlayers doped in entire region and up to 30 nm showed remarkable reduced leakage current and effectively relieved efficiency droop which is one of the biggest challenges in green light emitting diode. Furthermore, the most improved characteristics in current-voltage and electroluminescence was obtained by the latter structure.

A Study on Flicker Free LED Driver for Dimming MR16 Electronic Transformer (조광기용 MR16 안정기 호환 Flicker Free LED 구동회로 연구)

  • Kim, Taek-Woo;Hong, Sung-Soo;Yeom, Bong-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.327-331
    • /
    • 2014
  • LED(Light Emitting Diode) is a semiconductor device utilizing electroluminescent effect is a phenomenon in which a type of P-N junction diode, the light of short wavelength which a voltage is applied in the forward direction is released. LED is advantageous in reducing the energy as environmentally materials that can greatly reduce the carbon emissions, recent it has attracted attention IT(Information Technology) and GT(Green Technology) industry. In addition, there are advantages long life, high efficiency, and excellent response speed, LED have come into the spotlight as the illumination means to replace the existing fluorescent light and incandescent light bulb. When connecting to MR16 electronic transformer for existing LED driver circuit, due to malfunction of the dimmer and the electronic transformer, flicker occurs and linear dimming is not possible. Therefore, in this paper, we suggest an LED drive circuit there is no flicker with the corresponding dimming MR16 electronic transformer. Further, we explain the principles of the LED current control technique and the principle of the drive circuit of the LED, in order to validate the proposed circuit through prototyping and simulation.

Low Temperature Annealing Effect of PFO-Poss Emission Layer on the Properties of Polymer Light Emitting Diodes

  • Gong, Su-Cheol;Chang, Ho-Jung
    • Korean Journal of Materials Research
    • /
    • v.19 no.6
    • /
    • pp.313-318
    • /
    • 2009
  • Polymer Light Emitting Diodes (PLEDs) with an ITO/PEDOT:PSS/PVK/PFO-poss/LiF/Al structure were prepared on plasma-treated ITO/glass substrates using spin-coating and thermal evaporation methods. The annealing effects of the PFO-poss film when it acts as the emission layer were investigated by using electrical and optical property measurements. The annealing conditions of the PFO-poss emission film were 100 and $200^{\circ}C$ for 1, 2 and 3 hours, respectively. The luminance increased and the turn-on voltage decreased when the annealing temperature and treatment time increased. After examining the Luminance-Voltage (L-V) properties of the PLED, the maximum luminance was found to be 1497 cd/$m^2$ at 11 V for the device when it was annealed at $200^{\circ}C$ for 3 hours. The peak intensity of the PLED emission spectra at approximately 525 nm in wavelength increased when the annealing temperature and time of the PFO-poss film increased. These results suggest that the light emission color shifted from blue to green.

Evaluation on the lighting performance of a dynamic LED lighting system (동적 LED 시스템의 조명원적 성능분석)

  • Kim, Hyo-In;Kim, Jeong-Tai;Yun, Geun-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.2
    • /
    • pp.113-119
    • /
    • 2011
  • LED lighting has received much attention in recent years due to its high energy efficiency and environmental friendliness. As the color of light can be obtained by adjusting the light intensity of LEDs, the quality of visual environment can be improved. The aims of this study are to develop a wavelength adjustable LED lighting system and to examine its lighting performances. The LED lighting system and experimental cell for assessment of the lighting performance were constructed. This LED lighting system is able to materialize the various spectral power distribution and color temperature of light through the control of the four dimmers. Up to $432^4$ kinds of light combinations are possible. The range of illuminance on workplane were measured as 7~1,831 ㏓. Improvement of psychological and physical functions for occupants can be expected according to control of lighting performances.

The Effect of an Optical Clearing Agent on Tissue Prior to 1064-nm Laser Therapy

  • Youn, Jong-In
    • Medical Lasers
    • /
    • v.10 no.3
    • /
    • pp.146-152
    • /
    • 2021
  • Background and Objectives Although lasers have been widely applied in tissue treatment, the light penetration depth in tissues is limited by the tissue turbidity and affected by its absorption and scattering characteristics. This study investigated the effect of using an optical clearing agent (OCA) on tissue to improve the therapeutic effect of 1064 nm wavelength laser light by reducing the heat generated on the skin surface and increasing the penetration depth. Materials and Methods A diode laser (λ = 1064 nm) was applied to a porcine specimen with and without OCA to investigate the penetration depth of the laser light and temperature distribution. A numerical simulation using the finite element method was performed to investigate the temperature distribution of the specimen compared to ex-vivo experiments using a thermocouple and double-integrating sphere to measure the temperature profile and optical properties of the tissue, respectively. Results Simulation results showed a decrease in tissue surface temperature with increased penetration depth when the OCA was applied. Furthermore, both absorption and scattering coefficients decreased with the application of OCA. In ex-vivo experiments, temperatures decreased for the tissue surface and the fat layer with the OCA, but not for the muscle layer. Conclusion The use of an OCA may be helpful for reducing surface heat generation and enhance the light penetration depth in various near-infrared laser treatments.

Environment-dependent Broadband Perfect Absorption of Metal-insulator-metal Metamaterial Systems

  • Feng Li;Yulong Tang;Qingsong Peng;Guosheng Hu
    • Current Optics and Photonics
    • /
    • v.7 no.2
    • /
    • pp.136-146
    • /
    • 2023
  • Based on calculations using the macroscopic Maxwell's equations with mesoscopic boundary conditions, light absorption by a layered metal-insulator-metal (MIM) metamaterial system embedded in three different environments is investigated. Increasing the top metal thickness shifts the broad absorption band to lower dielectric-constant regions and longer wavelengths, for either TM or TE waves. Boosting the dielectric-layer thickness redshifts the broadband absorption to regions of larger dielectric constant. In air, for the dielectric-constant range of 0.86-3.40, the absorption of the system exceeds 98% across 680-1,033 nm. In seawater with optimized dielectric constant, ≥94% light absorption over 400-1,200 nm can be achieved; particularly in the wavelength range of 480-960 nm and dielectric-constant range of 0.82-3.50, the absorption is greater than 98%. In an environment with even higher refractive index (1.74), ≥98% light absorption over 400-1,200 nm can be achieved, giving better performance. The influence of angle of incidence on light absorption of the MIM system is also analyzed, and the angle tolerance for ≥90% broadband absorption of a TM wave is up to 40° in an environment with large refractive index. While the incident-angle dependence of the absorption of a TE wave is nearly the same for different circumstances, the situation is different for a TM wave.

Design of a Light and Small Dual-band Airborne Despun Optical System

  • Luqing Zhang;Ning Zhang;Xiping Xu;Kailin Zhang;Yue Zhang;Jiachong Li
    • Current Optics and Photonics
    • /
    • v.8 no.1
    • /
    • pp.97-104
    • /
    • 2024
  • In aerial cameras, image quality is easily affected by weather, temperature, and the attitude of the aircraft. Aiming at this phenomenon, based on the theory of two-step zoom optical systems, a dual-band optical-despun two-step zoom optical system is designed. The system has a small field of view of 2.00° × 1.60°, and a large field of view of 4.00° × 3.20°. In the zoom process, the wavelength range is 0.45-0.70 ㎛ and 0.75-1.10 ㎛, and the size of the optical system is 168 mm (L) × 90 mm (W) × 60 mm (H). The overall lens weight is only 170.8 g, which has advantages for miniaturization and light weight. At the Nyquist frequency of 104 lp/mm, the modulation transfer function of the visible-light optical system is more than 0.44, and that of the near-infrared optical system is more than 0.30, both of which have good imaging quality and tolerance characteristics in the range of -45 to 60 ℃.

Effect of forensic short wavelength UV on DNA (법과학 단파자외선이 DNA에 미치는 영향)

  • Kim, A-Ram;Kim, Woo-Joong;Park, Hee-Yeon;Lim, Si-Keun
    • Analytical Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.147-152
    • /
    • 2014
  • RUVIS(Reflective Ultraviolet Imaging System) is an effective equipment that detects the location of latent fingerprint at crime scene using short wavelength ultraviolet of 254 nm. In this study, the degree of DNA damage in biological samples was compared depending on the distance and time of processing using four commonly used RUVIS. 50% of DNA was damaged by treating 10 seconds at 10 cm distance in 3 types of RUVIS such as Police RUVIS, SIRCHIE mini light and SIRCHIE RUVIS. In addition, the degree of DNA damage was increased as the distance was closer and the treatment time was longer. It showed that short wavelength UV could cause DNA damage when used close to the samples at crime scene. Therefore, it was suggested to use RUVIS at a distance of at least 1 m. The degree of DNA damage was not significant by Polilight which used long wavelength ultraviolet of 350 nm. As a result, the choice and usage of which UV light and RUVIS were critical for detection of fingerprint and successful DNA typing.

Composite Gas Measurement System using NDIR Method (NDIR 방법을 이용한 복합 가스 측정 시스템)

  • Eo, Ik-soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.624-629
    • /
    • 2018
  • The current study was conducted to develop a portable composite gas detector allowing the detection of both $CO_2$ and $CH_4$ gases by means of the Non Dispersive Infra-Red (NDIR) method. The gas detector is configured to radiate infrared waves using infrared lamps, where the wavelength of the infrared light is reduced due to absorption throughout the chamber, and this reduction (absorption) is detected by the absorption detector, before being converted and amplified to a 3.5V~6V electrical signal, providing as accurate a measurement as possible. The conventional singe sensor method measures the relative measurement by absorbing only specified wavelengths of infrared radiation, which in the case of gas detection leads to problems with accuracy due to the lack of a reference sensor when detecting light with a wavelength of only $4.26{\mu}m$. The dual sensor employed in this study provides a comparative measurement between the reference value derived from the wavelength of $3.91{\mu}m$, which is not influenced by other gas sources, and the measurement value derived from the wavelength of $4.26{\mu}m$, in order to reduce the errors and enhance the reliability, thereby allowing low power consumption for portable devices and multi-gas detection for both $CO_2$ and $CH_4$ gases. The portable composite gas detector developed herein provides a measurement rage of 0ppm~5,000ppm for $CO_2$ gas, and 0.5%vol for $CH_4$, which allows the determination of whether the $CO_2$ and $CH_4$ contents in indoor air are less than 1,000ppm or not. The current study established that the composite gas detector can be interlinked with firefighting appliances through portable devices or home automation, and is anticipated to be very effective in fire prevention.