• Title/Summary/Keyword: internal heat distribution

Search Result 165, Processing Time 0.024 seconds

NATURAL CONVECTION HEAT TRANSFER CHARACTERISTICS IN A CANISTER WITH HORIZONTAL INSTALLATION OF DUAL PURPOSE CASK FOR SPENT NUCLEAR FUEL

  • Lee, Dong-Gyu;Park, Jea-Ho;Lee, Yong-Hoon;Baeg, Chang-Yeal;Kim, Hyung-Jin
    • Nuclear Engineering and Technology
    • /
    • v.45 no.7
    • /
    • pp.969-978
    • /
    • 2013
  • A full-sized model for the horizontally oriented metal cask containing 21 spent fuel assemblies has been considered to evaluate the internal natural convection behavior within a dry shield canister (DSC) filled with helium as a working fluid. A variety of two-dimensional CFD numerical investigations using a turbulent model have been performed to evaluate the heat transfer characteristics and the velocity distribution of natural convection inside the canister. The present numerical solutions for a range of Rayleigh number values ($3{\times}10^6{\sim}3{\times}10^7$) and a working fluid of air are further validated by comparing with the experimental data from previous work, and they agreed well with the experimental results. The predicted temperature field has indicated that the peak temperature is located in the second basket from the top along the vertical center line by effects of the natural convection. As the Rayleigh number increases, the convective heat transfer is dominant and the heat transfer due to the local circulation becomes stronger. The heat transfer characteristics show that the Nusselt numbers corresponding to $1.5{\times}10^6$ < Ra < $1.0{\times}10^7$ are proportional to 0.5 power of the Rayleigh number, while the Nusselt numbers for $1.0{\times}10^7$ < Ra < $8.0{\times}10^7$ are proportional to 0.27 power of the Rayleigh number. These results agreed well with the trends of the experimental data for Ra > $1.0{\times}10^7$.

A Study on the Characteristics Assessment and Fabrication of Distribution Board according to KEMC Standards (KEMC 규정에 의한 분전반의 제작 및 특성 평가에 관한 연구)

  • Lee, Byung-Seol;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.63-72
    • /
    • 2017
  • This study fabricated a low-voltage 10 circuit distribution board based on the KEMC (Korea Electrical Manufacturers Cooperative) 2102-610 standard and performed a characteristics assessment of the developed 10 circuit distribution board to secure product stability. The developed 10 circuit distribution board is designed to have the characteristics of insulation materials, as well as resistance to corrosion ultraviolet radiation and mechanical impact. The developed distribution board is fabricated to have an appropriate protection class of enclosure, electric shock prevention and protection circuits, switchgear and its components, internal electrical circuits and connectors, external conduct terminal, insulation characteristics, temperature rise test, heat resistance, etc. The developed 10 circuit distribution board consists of a single phase circuit and 3-phase circuits. It is possible to measure in real time the leakage current generated from the load distribution line by installing a sensor module at the load side of each of the branched switchgears. In addition, it is possible to increase a circuit according to the use and purpose of the load and to also manage and check the load in real time. Temperature rise tests were performed on the developed 10 circuit distribution board at 18 places including the inlet connection, main circuit and distribution circuit bus bars and bus bar supports, etc. The highest temperature of $65.3^{\circ}C$ was measured at the R-Phase of the connection of the MCCB power supply for the branch circuit bus bar and a temperature rise of $61.6^{\circ}C$ was measured at the T-Phase of the load side. When applying thermal stress to an MCCB for 6 hours at $180^{\circ}C$ using a heat resistant experimental device, it was found that the actuator lever was transformed and moved in the tripped state.

Mechanical analysis for prestressed concrete containment vessels under loss of coolant accident

  • Zhou, Zhen;Wu, Chang;Meng, Shao-ping;Wu, Jing
    • Computers and Concrete
    • /
    • v.14 no.2
    • /
    • pp.127-143
    • /
    • 2014
  • LOCA (Loss Of Coolant Accident) is one of the most important utmost accidents for Prestressed Concrete Containment Vessel (PCCV) due to its coupled effect of high temperature and inner pressure. In this paper, heat conduction analysis is used to obtain the LOCA temperature distribution of PCCV. Then the elastic internal force of PCCV under LOCA temperature is analyzed by using both simplified theoretical method and FEM (finite element methods) method. Considering the coupled effect of LOCA temperature, a nonlinear elasto-plasitic analysis is conducted for PCCV under utmost internal pressure considering three failure criteria. Results show that the LOCA temperature distribution is strongly nonlinear along the shell thickness at the early time; the moment result of simplified analysis is well coincident with the one of numerical analysis at weak constraint area; while in the strong constrained area, the value of moments and membrane forces fluctuate dramatically; the simplified and numerical analysis both show that the maximum moment occurs at 6hrs after LOCA.; the strain of PCCV under LOCA temperature is larger than the one of no temperature under elasto-plastic analysis; the LOCA temperature of 6hrs has the greatest influence on the ultimate bearing capacity with 8.43% decrease for failure criteria 1 and 2.65% decrease for failure criteria 3.

A Study on Induction Heating with Forced Surface Cooling in Semi-Solid Forming Process (반용융 성형에서 강제 표면 냉각에 의한 유도 가열 방법에 관한 연구)

  • Park Joon Hong;Choi Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.1
    • /
    • pp.97-102
    • /
    • 2005
  • The procedure of semi-solid forming is composed of heating a billet, forming, compression holding and ejecting step. There are several methods to heat a billet during semi-solid forming process such as electric heating and induction heating. Usually in semi-solid forming process, induction heating has been adopted to achieve more uniform temperature of semi-solid material. Although induction heating is better method than any others, however, there is still difference of temperature between internal part and surface part of semi-solid material. Worse yet, in case of high liquid fraction of semi-solid material, liquid of the billet will flow down though solid of the billet still remains, which is very difficult to handle. In the present study, induction heating of semi-solid material with compulsive surface cooling has been performed to obtain uniform distribution of temperature. Distribution of temperature of the billets was measured and compared with that of conventional distribution of temperature. By this new induction heating method, not only temperature over the whole billet become uniform, but also control of temperature is possible.

A Study on Induction Heating with Compulsive Surface Cooling in Semi-Solid Forming Process (반용융 성형에서 간제 표면 냉각에 의한 유도 가열 방법에 관한 연구)

  • Choi, J. C.;Kim, B. M.;Choi, Y.;Park, J. H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.465-468
    • /
    • 2000
  • The procedure of semi-solid forming is composed of heating a billet, forming, compression holding and ejecting step. There are several methods to heat a billet during semi-solid forming process such as electric heating and induction heating. Usually in semi-solid forming process, induction heating has been adopted to achieve more uniform temperature of semi-solid material. Although induction heating is better method than any others, however, there is still difference of temperature between internal part and surface part of semi-solid material. Worse yet, in case of high liquid fraction of semi-solid material, liquid of the billet will flow down though solid of the billet still remains, which is very difficult to handle. In the present study, induction heating of semi-solid material with compulsive surface cooling has been performed to obtain uniform distribution of temperature. Distribution of temperature of the billets was measured and compared with that of conventional distribution of temperature. By this new induction heating method, not only temperature over the whole billet become uniform, but also control of temperature is possible.

  • PDF

Prediction of Stratification Model for Diffusers in Underfloor Air Distribution System using the CFD (CFD를 활용한 바닥공조시스템 디퓨저의 성층화 모델 예측)

  • Son, Jeong-Eun;Yu, Byeong-Ho;Pang, Seung-Ki;Lee, Kwang Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.3
    • /
    • pp.105-110
    • /
    • 2017
  • Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings. UFAD systems use the underfloor plenum beneath a raised access floor to provide conditioned air through floor diffusers that create a vertical thermal stratification during cooling operations. Thermal stratification has significant effects on energy, indoor air quality, and thermal comfort performance. The purpose of this study was to characterize the influence of a linear bar grille diffuser on thermal stratification in both interior and perimeter zones by developing Gamma-Phi based prediction models. Forty-eight simulations were carried out using a Computational Fluid Dynamics (CFD) technique. The number of diffusers, the air flow supply, internal heat gains, and solar radiations varied among the different cases. Models to predict temperature stratification for the tested linear bar grille diffuser have been developed, which can be directly implemented into dynamic whole-building simulation software such as EnergyPlus.

Thermal Distribution Analysis of Triple-Stacked ZnO Varistor (3층으로 적층된 ZnO 바리스터의 열분포 해석)

  • Kyung-Uk Jang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.4
    • /
    • pp.391-396
    • /
    • 2023
  • Recently, as power and electronic devices have increased in frequency and capacity, it has become a major concern to protect electronic circuits and electronic components used in these devices from abnormal voltages such as various surges and pulse noise. To respond to variously rated voltages applied to power electronic devices, the rated voltages of various varistors can be obtained by controlling the size of internal particles of the varistor or controlling the number of layers of the varistor. During bonding, the problem of unbalanced thermal runaway occurring between the electrode and the varistor interface causes degradation of the varistor and shortens its life of the varistor. In this study, to solve the problem of unbalanced heat distribution of stacked varistors to adjust the operating voltage, the contents of the ZnO-based varistor composition were 96 wt% ZnO, 1 mol% Sb2O3, 1 mol% Bi2O3, 0.5 mol% CoO, 0.5 mol% MnO, and 1 mol% TiO2. A multi-layered ZnO varistor was modeled by bonding a single varistor with a composition in three layers according to the operating voltage. The thermal distribution of the triple-layered ZnO varistor was analyzed for the thermal runaway phenomenon that occurred during varistor operation using the finite element method according to Comsol 5.2.

Responses of HSP Gene Expressions to Elevated Water Temperature in the Nile tilapia Oreochromis niloticus

  • Kwon, Joon-Yeong;Kim, Ju-Yeong
    • Development and Reproduction
    • /
    • v.14 no.3
    • /
    • pp.179-184
    • /
    • 2010
  • Water temperature influences on various key biological events in fish, but the internal pathway of the temperature effects are not well understood. Heat shock proteins (HSPs), known to respond in the level of cells to many environmental factors including temperature, could improve our understanding on the pathway. Some biological processes such as gonadal development and sex differentiation in the Nile tilapia Oreochromis niloticus is particularly sensitive to water temperature. In this study, we have investigated the expressions of HSP70 and HSP90 genes in young tilapia at an ordinary temperature ($28^{\circ}C$) and elevated water temperature ($36^{\circ}C$). The distribution of the expressions of HSP70 and HSP90 mRNA in this species were found to be almost ubiquitous, being detected in all tissues studied here (brain, gonad, liver and muscle), suggesting the house keeping functions of these genes. Heat shock by elevating temperature from $28^{\circ}C$ to $36^{\circ}C$ significantly increased the expression of HSP70 mRNA in the gonad, liver and muscle for several hours (P<0.05) (brain tissue was not examined for this). The increased level of HSP70 gene expression recovered to the level at control temperature ($28^{\circ}C$) when fish were kept continuously at high temperature ($36^{\circ}C$) for 24 hours. Contrary to this, expression of HSP90 mRNA did not show significant increase in the gonad and muscle by the same heat shock (P>0.05), except in the liver where the expression of HSP90 mRNA increased continuously for 24 hours at $36^{\circ}C$. The results obtained in this study suggest that response to temperature change in different tissue or organ may utilize different heat shock proteins, and that HSP70 may have some importance in temperature-sensitive gonadal event in the Nile tilapia.

Development of the Dryer with a Heat Source of Carbon Nanofibers (탄소나노섬유를 열원으로 적용한 세탁물 건조기의 개발)

  • Lee, Jung-Hwan;Won, Sang-Yeon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.23 no.3
    • /
    • pp.25-34
    • /
    • 2018
  • This paper presents a heating source of carbon nanofibers for the efficiency and the drying performance of laundry dryer, and focuses on the applicability-evaluation of its source. To design the proposed heating module, experiments were conducted in terms of surface temperature and surface temperature distribution characteristics of carbon nanofiber lamps. The surface temperature of the lamps increased linearly with increment of a current to flow a lamp and revealing the increasing pattern as the length of the ramps is shorter. The proposed heating source was evaluated based on drying efficiency, moisture evaporation rate at laundry, and internal temperature of a drum during drying process. The drying efficiency satisfied a 45% which is specified in KS C 9319. The moisture evaporation rate and the internal temperature of the drum were respectively 98.88% and $61.1^{\circ}C$, which are similar to that of S's company dryer. From the evaluation and actual drying test results, the proposed carbon nanofiber lamp heating module is considered to be applicable as a heat source for laundry dryer in terms of drying efficiency and drying performance. it is possible to obtain a heat source at a high temperature, an excellent calorific value, an improvement in drying performance, and an effect of sterilizing laundry due to the emission of far-infrared rays. In addition to the applicability, the difference of the drying efficiency between the dryers was analyzed in detail based on the power consumption of the heat sources.

Effect on Thermal Performance of Superheater Module under Part Load Operation in HRSG (배열회수보일러의 부분부하 운전에 따른 유동불균일이 과열기의 성능에 미치는 영향)

  • Chong, Chae-Hon;Song, Jung-Il
    • Journal of Energy Engineering
    • /
    • v.17 no.3
    • /
    • pp.161-166
    • /
    • 2008
  • The purpose of this study is to apprehend the behavior of exhaust gas flow from gas turbine during part load operation in Heat Recovery Steam Generator. As a first step of this work, internal flow characteristics according to HRSG types were examined by CFD analysis. Next step, tube temperature according to gas turbine 53% and 100% load conditions were calculated by results of CFD and those were compared with temperature data gathered from real plant. Finally, thermal performance due to part load operation was calculated to estimate the influence of heat transfer in superheater. In addition, new type of device is suggested to eliminate the uneven temperature distribution of tubes during part load operation.