• Title/Summary/Keyword: installation/management

Search Result 1,166, Processing Time 0.024 seconds

The Peak Load Forecast of Pole-Transformers by Working Electrical Energy (사용전력량에 의한 주방변압기의 최대 부하 예측)

  • Lee, Dong-Jun;Han, Sung-Ho;Lee, Wook;Kwak, Hee-Ro;Kim, Jae-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.101-103
    • /
    • 1996
  • This Paper describes Peak load forecasting technique of pole transformers with correlation equation. While customers are demanding safe energy supply, current correlation equation that is used for load management of pole transformers has some problems. To get accurate correlation equation. several correlation equation were examined using past data and nu data collected using the measuring instrument developed for this study. It was recognized that the quadratic equation was the most accurate for peak load forecasting from working electrical energy.

  • PDF

The Study on the Temperature Distribution for 154kV Power Transformers (154kV 전력용 변압기의 온도분포에 관한 연구)

  • Woo, Jung-Wook;Koo, Kyo-Sun;Kwak, Joo-Sik;Kim, Kyung-Tak;Kweon, Dong-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.9
    • /
    • pp.56-61
    • /
    • 2011
  • The temperature of power transformers is very important factor for power system operation in substation because load capacity and limited lifetime of power transformers are determined by winding temperature. Also, The temperature of power transformers varies with the structure, capacity, operation condition and manufacturers. Thus, it is necessary for temperature distribution to be exactly investigated because of efficient load management and prediction of limited lifetime. Nevertheless, there was no case of analysis as well as measurement of the temperature of power transformers. In this paper, we manufactured the 154kV standard power transformer for the test. And we measured the temperature by the heat run test and analyzed the temperature distribution of transformer.

Development of efficient Web-based Light Facility Control and Management System (효율적인 Web기반 조명시설 제어 및 관리 시스템의 개발)

  • Chang, Byong-Kun;Jeon, Chang-Dae
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.347-350
    • /
    • 2004
  • In this paper, PDA(Personal Digital Assistants) terminal is proposed to be used for controlling and managing light facilities efficiently by connecting it to a web-based server system and adding additional functions. The control box of current light facilities may be implemented based on a simple On-Off function. The operational quality of the light facilities will be efficiently improved with some practical advantages such as reduction of required facility, manpower and time in managing the lights and control boxes tv using the popular PDA.

  • PDF

Embedded Platform Architecture for Substation Automation

  • Kim, Hak-Man;Cha, Jae-Sang;Lee, Jong-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.9
    • /
    • pp.76-80
    • /
    • 2007
  • For a more efficient and economical management of substations of power system areas, the concept of substation automation has been introduced using intelligent and ubiquitous IT techniques. In this paper, ubiquitous IT prototype hardware, functions and communication interfaces on an embedded platform for substation automation are proposed. Also, operating system architecture is suggested for the effective implementation of substation automation.

Selection of Operating Parameters and Management of Operation Console for Protection and Control of Steam Turbine in a Korea Standard Type Nuclear Power Plant (한국 표준형 원자력 발전소 증기터빈 보호 및 제어를 위한 운전인자 선정과 운전반 운영)

  • Choi, In-Kyu;Kim, Jong-An;Woo, Joo-Hee;Shin, Man-Su
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.71-78
    • /
    • 2011
  • This paper contains the selection of operation parameters for protection and control of steam turbine in a Korea Standard Type Nuclear Power Plant. The safety of nuclear reactor must be ensured which generates nuclear energy and produces steam. Also, the safety of turbine, which consume the nuclear energy as a core machine, must be ensured. For the purpose of this, we describe how the operating parameters were selected, reviewed, implemented into the operator console and finally put into actual operation of the system.

The Study of Cable Fault Case and the Fault Management System of Electrical Facilities for private use (자외선 영상 이미지 비교를 통한 22.9kV 특고압 설비의 상태진단 연구)

  • Kim, Young-Seok;Shong, Kil-Mok
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.211-213
    • /
    • 2009
  • This paper was studied about the ultra-violet rays(UV) image area and discharge quantity of 22.9kV class polymer insulator using UV camera. The UV image area was begun to observe to 60kV that is about 40% of breakdown voltage of polymer insulator and the area was increased by applied voltage. Also, the discharge quantity was increased at 60kV sharply. If the intensity of breakdown passes over about 40% we can know that need the check on the electrical facility.

  • PDF

A Study on the Calculation of Optimal Subsidy for LED Appliance using Diffusion Model (확산모형을 이용한 LED 조명기기의 최적보조금 산정에 관한 연구)

  • Son, Hag-Sig
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.3
    • /
    • pp.1-7
    • /
    • 2015
  • Korea's electricity supply and demand policy has focusing on electricity demand side management instead of the expanding supply and a lot of effort for LED(Light Emitting Diode) at the time. This paper calculated the optimal subsidy for LED spread. For this purpose, it analyzed the impact on spread of the lighting appliances each subsidy level from BDM(Bass Diffusion Model) and predicted the number of lighting appliances according to subsidy level in the future. The case study is calculated susidy for satisfaction of LED target using the suggested model in the future and verified availability.

The Cost Reduction Effect of Gridable Sea Water Reverse Osmosis Desalination Plant (전력망 연동형 해수담수화 플랜트의 운영비용 절감효과)

  • Lee, Jong-Hyun;Choi, Jung-In;Bae, Si-Hwa;Ko, Won-Suk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.64-69
    • /
    • 2011
  • A novel concept of the gridable desalination plant is to provide an operation management to enable an electricity plant operation cost reduction. Adjusting recovery rate responded to electricity price, an electricity plant operation cost can be saved. To show a suggested approach, the data of 10 [MIGD](Million Imperial Gallons per Day) SWRO testbed are used. The result shows that total cost reduction rate is calculated about 1.6[%] of annual total electric plant operation cost.

The Study on the Actual Examination of the Bidirectional Protection Device in the 22.9[kV] Distribution Power System Interconnected with the DG (분산전원이 연결된 22.9[kV] 배전계통의 양방향 보호기기 실증시험 연구)

  • Lee, Heung-Jae;Choi, Myeong-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.10
    • /
    • pp.102-108
    • /
    • 2011
  • The existing power flow has a single direction to the line end but the bidirectional power flow will possibly occur depending on the output capacity in the 22.9[kV] distribution power system connected with the dispersed generation(DG). So these characteristics would influence the power system management. The DG have many advantages such as assistance source, Load share etc. So the utility must apply the bidirectional protection system so as to maximize an advantage of DG. This paper describes the field test case of bidirectional protective device in order to investigate the device performance when applied to bidirectional power system. We have tested in the power system test site of KEPCO and these tests provide the basis for performance verification test of bidirectional protective device in the power system.

The Development of a Flood Protection System for Pad Transformers Using Pneumatic Pressure in Areas Prone to Floods

  • Kim, Gi-Hyun;Lee, Jae-Yong;Bae, Suk-Myong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.3
    • /
    • pp.27-32
    • /
    • 2010
  • The inundation of substation and ground power equipment breaks out every summer season in low-lying downtown areas and low-lying shores by torrential rain, typhoons and tsunamis. It has, in turn, caused replacement, social and economic costs for blackouts. For activity management regarding flood damage we produced a flood protection system which using the Pad transformer as a basic frame and is developed using pneumatic pressure. We tested safety concerns including insulation resistance and current leakage first for water tank flooding and, second, by an empirical test through supplying 22.9[kV]. We estimate that costs associated with flooding and power failure can be diminished by these advances toward creating a more reliable system.