• 제목/요약/키워드: impression materials

검색결과 313건 처리시간 0.022초

멀티미디어를 이용한 치과환자교육 시스템 개발 (Development of Dental Patient Education System using Mutimedia)

  • 김무성;이승진;남기곤;김형일;이영우;전계록
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.52-56
    • /
    • 1996
  • The elevation of present medical service using advanced science contributes to offer medical examination and treatment of good quality under the subject of patient satisfaction as well as patient impression. The dental service field charging some part of public health promotion and public welfare promotion also intends to improve the dental examination and treatment quality utilizing advanced science. The object of this research is the development of dental patient education system (DPES) using multimedia of new technology. DPES can be employed for these object, harmonious operation of dental examination and treatment, treatment quality improvement, disease notice to patient under the subject of patient satisfaction and patient impression, explanation of some selective treatment course, the verification of treatment necessities and treatment validation, and the improvement of treatment effect through the oral cavity sanitation education in the sense of prevention. This research also serves the development environment, the step to collect educational document, visual information and to structure those, and the examination of DPES efficiency in clinic.

  • PDF

Accuracy of casts produced from conventional and digital workflows: A qualitative and quantitative analyses

  • Abduo, Jaafar
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권2호
    • /
    • pp.138-146
    • /
    • 2019
  • PURPOSE. Comparing the accuracy of casts produced from digital workflow to that of casts produced from conventional techniques. MATERIALS AND METHODS. Whole arch alginate (ALG) and polyvinyl siloxane (PVS) impressions were taken with stock trays and custom trays, respectively. The ALG impressions were poured with type III dental stone, while the PVS impressions were poured with type IV dental stone. For the digital workflow, IOS impressions were taken and physical casts were produced by 3D printing. In addition, 3D printed casts were produced from images obtained from a laboratory scanner (LS). For each technique, a total of 10 casts were produced. The accuracies of the whole arch and separated teeth were virtually quantified. RESULTS. Whole arch cast accuracy was more superior for PVS followed by LS, ALG, and IOS. The PVS and ALG groups were inferior in the areas more susceptible to impression material distortion, such as fossae and undercut regions. The LS casts appeared to have generalized errors of minor magnitude influencing primarily the posterior teeth. The IOS casts were considerably more affected at the posterior region. On the contrary, the IOS and LS casts were more superior for single tooth accuracy followed by PVS and ALG. CONCLUSION. For whole arch accuracy, casts produced from IOS were inferior to those produced from PVS and ALG. The inferior outcome of IOS appears to be related to the span of scanning. For single tooth accuracy, IOS showed superior accuracy compared to conventional impressions.

알지네이트 인상체에서 제작된 치과용 석고 모형의 정확도에 대한 삼차원 디지털 분석 (Three dimensional accuracy analysis of dental stone casts fabricated using irreversible hydrocolloid impressions)

  • 주용훈;이진한
    • 구강회복응용과학지
    • /
    • 제31권4호
    • /
    • pp.316-328
    • /
    • 2015
  • 목적: 보관 조건과 석고 주입 시간에 따라 알지네이트 인상체로부터 제작된 모형의 정확성을 알아보고자 하였다. 연구 재료 및 방법: 채득된 알지네이트 인상체는 습도가 유지되는 항습조에 보관하는 것과 진료실 내의 공기 중에 노출되는 상태로 보관 조건을 달리하였다. 보관 조건에 따라 각각 즉시, 채득된 후 10분, 30분, 180분, 360분으로 나누어 보관한 후에 석고 모형을 제작하였다. 제작된 석고 모형을 3D 레이저 스캐너로 삼차원 디지털 모형을 구성하였고 구성된 디지털 모형의 참고점에서 거리를 측정하여 변형률을 비교하였다. 또한 각 실험군의 삼차원 디지털 평균 모형을 제작한 후 중첩을 시행함으로써 표면 변위가 발생한 부위와 크기를 확인하였다. 결과: 인상 채득 즉시 제작한 모형의 변형률이 가장 작게 나타났고, 공기 중에 보관한 인상체보다 항습조에 보관한 인상체의 변형률이 작게 나타났다. 석고 주입 시간이 증가함에 따라서 변형률도 증가하였으며, 석고 주입 시간이 180분을 지나면 보관 조건에 관계없이 대구치 부위에서 변형률과 표면 변위가 증가한다. 결론: 알지네이트 인상체로부터 제작된 모형의 정확성을 위해서는 인상 채득 후, 즉시 모형을 제작해야 한다. 보관이 필요한 경우에는 100% 상대습도가 유지되는 항습조를 이용하고, 보관 시간은 180분을 넘지 않도록 해야 정확한 모형을 얻을 수 있다.

White light scanner-based repeatability of 3-dimensional digitizing of silicon rubber abutment teeth impressions

  • Jeon, Jin-Hun;Lee, Kyung-Tak;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권4호
    • /
    • pp.452-456
    • /
    • 2013
  • PURPOSE. The aim of this study was to evaluate the repeatability of the digitizing of silicon rubber impressions of abutment teeth by using a white light scanner and compare differences in repeatability between different abutment teeth types. MATERIALS AND METHODS. Silicon rubber impressions of a canine, premolar, and molar tooth were each digitized 8 times using a white light scanner, and 3D surface models were created using the point clouds. The size of any discrepancy between each model and the corresponding reference tooth were measured, and the distribution of these values was analyzed by an inspection software (PowerInspect 2012, Delcamplc., Birmingham, UK). Absolute values of discrepancies were analyzed by the Kruskal-Wallis test and multiple comparisons (${\alpha}$=.05). RESULTS. The discrepancy between the impressions for the canine, premolar, and molar teeth were $6.3{\mu}m$ (95% confidence interval [CI], 5.4-7.2), $6.4{\mu}m$ (95% CI, 5.3-7.6), and $8.9{\mu}m$ (95% CI, 8.2-9.5), respectively. The discrepancy of the molar tooth impression was significantly higher than that of other tooth types. The largest variation (as mean [SD]) in discrepancies was seen in the premolar tooth impression scans: $26.7{\mu}m$ (95% CI, 19.7-33.8); followed by canine and molar teeth impressions, $16.3{\mu}m$ (95% CI, 15.3- 17.3), and $14.0{\mu}m$ (95% CI, 12.3-15.7), respectively. CONCLUSION. The repeatability of the digitizing abutment teeth's silicon rubber impressions by using a white light scanner was improved compared to that with a laser scanner, showing only a low mean discrepancy between $6.3{\mu}m$ and $8.9{\mu}m$, which was in an clinically acceptable range. Premolar impression with a long and narrow shape showed a significantly larger discrepancy than canine and molar impressions. Further work is needed to increase the digitizing performance of the white light scanner for deep and slender impressions.

디지털 인상법과 전통적 인상법의 정확도 비교: 체계적 고찰 (Comparison of the accuracy of digital impressions and traditional impressions: Systematic review)

  • 김경록;서권수;김선재
    • 대한치과보철학회지
    • /
    • 제56권3호
    • /
    • pp.258-268
    • /
    • 2018
  • 목적: 본 연구는 보철물의 적합 및 인상의 정확성에 관한 문헌들을 체계적으로 고찰하여 구강 내 스캐너를 이용한 디지털 인상법이 전통적인 인상법을 대체할 만한 정확도를 보이는지 알아보고자 한다. 재료 및 방법: 1997년 8월 1일부터 2017년 7월 31일까지 출판된 영어로 쓰여진 연구를 대상으로 디지털 인상법의 정확성에 대한 문헌을 MEDLINE/PubMed 전자 검색 및 수기탐색을 시행하였다. 조건에 따라 선택된 연구의 데이터를 스프레드 시트에 2명의 검토자가 독립적으로 정리하였다. 결과: 총 35개의 연구가 선택되었고, 26개의 연구는 보철물의 적합성을 비교하였고 9개의 연구는 보철물 없이 스캔 데이터를 통해 인상의 정확성을 비교하였다. 대부분의 연구가 보철물을 이용해 인상법의 정확성을 비교하였다. 결론: 본 고찰에 따르면 자연치열에서 디지털 인상법으로 단일관이나 근원심으로 길이가 짧은 보철물을 제작하는 것은 임상적으로 충분히 신뢰할만한 하다. 그러나 디지털 인상법으로 길이가 긴 보철물을 제작하는 것은 연구가 적어 아직 한계가 있다. 임플란트 보철물 제작에 있어서 구내스캐너를 이용한 디지털 인상법으로 전통적인 인상법을 완전히 대체하기는 아직 어렵다.

CEREC 3D System을 이용한 당일수복 (one-day treatment) 임상증례

  • 정효경
    • 대한심미치과학회지
    • /
    • 제17권1호
    • /
    • pp.23-30
    • /
    • 2008
  • Application of CAD/CAM is changing the way partial or full veneer all ceramic restoration is made. CAD/CAM systems, which were used mainly in other industries, have been developed and introduced for the dental purposes recently. It produced a flood of information on the CAD/CAM systems. It also influenced the development of restorative materials and all ceramic is substituting the traditional restorative materials of gold, composite resin and metal. Price increase of gold and other raw materials made the all ceramic more appealing. The introduction of a CEREC 3D system was innovative in several ways. Image of the prepared tooth is captured by camera and impression taking is unnecessary. Restoration can be delivered to the patient on one appointment and it will satisfy the demand of busy patients. One-day treatment with direct CAD/CAM system saves time compared to indirect CAD/CAM system. More superior restoration can be produced if lab work such as the adaptability check and shade selection is cooperated with lab technician. Short working time and comparably superior shade compatibility of color block was close to ideal. In the future, restorations with better quality can be fabricated in less time to busy patients thanks to the development of CAD/CAM system and dental materials.

  • PDF

Surface hardness measurement of NiP-plated AA7050

  • Moon, Sungmo;Kim, Juseok
    • 한국표면공학회지
    • /
    • 제54권4호
    • /
    • pp.171-177
    • /
    • 2021
  • This paper is concerned with the surface hardness measurement of NiP-coated AA7050 using different loads from 10 to 100 g. The surface hardness was observed to increase from 180 to 600 Hv with increasing NiP layer thickness, depending on the load applied for indentation. When NiP coating thickness is thinner than 2 ㎛, the surface hardness of NiP-coated AA7050 was mainly determined by AA7050 substrate, while it was significantly increased by NiP coating layer when NiP coating thickness is thicker than 2 ㎛. Hardness of AA7050 substrate itself was not dependent on the applied load but the hardness of NiP-coated AA7050 was largely influenced by the load applied for indentation. The largest difference of hardness between 10 g and 100g of applied loads, was obtained at the NiP thickness of about 8 ㎛ above which the measured hardness at 10 g reached a maximum value of about 600 Hv. It was also observed that indentation-induced plastic deformation next to the indented zone occurs when NiP layer is 5.64 times thicker than the depth of impression formed by indentation.

경사진 임플란트에서 임플란트 인상의 정확도 평가를 위한 역공학 기법 (Reverse engineering technique on the evaluation of impression accuracy in angulated implants)

  • 정홍택;이기선;송소연;박진홍;이정열
    • 대한치과보철학회지
    • /
    • 제59권3호
    • /
    • pp.261-270
    • /
    • 2021
  • 목적: 본 연구의 목적은 (1) 기존에 존재하던 몇 가지 다른 임플란트 인상의 정확도 평가방법들과 역공학 기술을 비교하고 (2) 역공학 기술로 임플란트 식립 방향 및 임플란트 인상용 코핑의 종류에 따른 인상 채득의 정확도를 평가하는 것이다. 재료 및 방법: 임플란트 식립 방향에 따른 세 가지 다른 마스터 모델을 제작하였고, 그 중 임플란트를 평행하게 식립한 마스터 모델에서 두 임플란트 중심점 사이의 거리를 다음과 같은 세 가지 방법으로 측정하였다 (디지털 캘리퍼를 이용한 측정 방법(그룹 DC), 광학 사진을 이용한 측정 방법(그룹 OM) 및 역공학 기술을 이용한 측정 방법(그룹 RE)). 세 종류의 마스터 모델 별로 각각 세 가지 유형의 임프레션 코핑을 이용하여 인상을 채득한 후 총 90개의 실험 모델을 제작하였으며 각 실험 모델들과 마스터 모델 간의 각도 및 거리의 오차율(error rate)을 계산하였다. 세 가지 평가 방법 간의 비교에는 One-way ANOVA가 사용되었다 (P < .05). 각 실험 그룹들의 오차율은 two-way ANOVA를 이용하여 분석하였다 (P < .05). 결과: 그룹 DC의 오차율과 그룹 RE의 오차율 간에는 통계적으로 유의한 차이가 있었지만 (P < .05), 그룹 OM의 오차율을 다른 그룹들과 비교하였을 때는 통계적으로 유의한 차이가 없었다(P > .05). 역공학 기술로 측정한 오차율의 표준 편차는 디지털 캘리퍼 및 광학 사진 측정으로 계산한 오차율의 표준 편차보다 상당히 낮았다. 하이브리드 인상용 코핑 그룹은 거리 오차율에서 픽업 인상용 코핑 그룹과 큰 차이가 없었다 (P > .05). 결론: 본 실험을 통해 역공학 기술이 임플란트 인상의 삼차원적인 정확도 평가 기법으로서의 잠재력이 있음을 확인하였다.

Role of span length in the adaptation of implant-supported cobalt chromium frameworks fabricated by three techniques

  • Zhou, Ying;Li, Yong;Ma, Xiao;Huang, Yiqing;Wang, Jiawei
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권2호
    • /
    • pp.124-129
    • /
    • 2017
  • PURPOSE. This study evaluated the effect of span length on the adaptation of implant-supported cobalt chromium frameworks fabricated by three techniques. MATERIALS AND METHODS. Models with two solid abutment analogs at different inter-abutment distances were digitized using a laboratory scanner. Frameworks of two-, three-, and four-unit fixed prostheses were designed by a computer. Six dots with a diameter of 0.2 mm were preset on the surface of each framework. A total of 54 implant-supported cobalt chromium frameworks were fabricated by milling, selective laser melting (SLM), and cast techniques. The frameworks were scanned and exported as Stereolithography files. Distances between two dots in X, Y, and Z coordinates were measured in both the designed and fabricated frameworks. Marginal gaps between the framework and the abutments were also evaluated by impression replica method. RESULTS. In terms of distance measurement, significant differences were found between three- and four-unit frameworks, as well as between two- and four-unit frameworks prepared by milling technique (P<.05). Significant differences were also noted between two- and three-unit frameworks, as well as between two- and four-unit frameworks prepared by cast technique (P<.05). The milling technique presented smaller differences than the SLM technique, and the SLM technique showed smaller differences than the cast technique at any unit prostheses (P<.05). Evaluation with the impression replica method indicated significant differences among the span lengths for any fabrication method (P<.05), as well as among the fabrication methods at any unit prostheses (P<.05). CONCLUSION. The adaptation of implant-supported cobalt chromium frameworks was affected by the span length and fabrication method.

The relationship of maxillary canines to the facial anatomical landmarks in a group of Thai people

  • Sinavarat, Potchaman;Anunmana, Chuchai;Hossain, Sharafat
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권4호
    • /
    • pp.369-373
    • /
    • 2013
  • PURPOSE. The objective was to evaluate canine positions, intercanine tip width (ICTW) and width of distal surface of canine (WDC), related to facial landmarks including interalar width (IAW), intercommissural width (ICoW), and distance between left and right projection lines drawn from inner canthus of eyes to alae of the nose (DPICa) in a group of Thai. MATERIALS AND METHODS. One hundred Thai subjects aged 18-35 years were selected. IAW and ICoW were measured on subject's face using digital vernier caliper. Irreversible hydrocolloid impression of the upper arch was taken, and a cast was poured with dental stone. Silicone impression material was used to take imprint of the incisal edge of upper six anterior teeth. DPICa was obtained from the subject's face using custom-made measuring equipment and marked on the silicone incisal imprint. The marks were then transferred from the imprint to the stone cast and measured with digital caliper. The ICTW and WDC were also measured on the stone cast. Pearson's correlation was used to determine the correlation. RESULTS. The results revealed that the correlation between ICTW-ICoW was 0.429 and ICTW-DPICa was 0.573. The correlation between WDC-ICoW was 0.426 and WDC-DPICa was 0.547. However, IAW did not show any correlation with ICTW or WDC (P>.05). CONCLUSION. The correlation between canine position and facial landmarks was found. ICTW and WDC had relationship with ICoW and DPICa. DPICa showed stronger correlation with the position of maxillary canine than that of ICoW.