DOI QR코드

DOI QR Code

Three dimensional accuracy analysis of dental stone casts fabricated using irreversible hydrocolloid impressions

알지네이트 인상체에서 제작된 치과용 석고 모형의 정확도에 대한 삼차원 디지털 분석

  • Joo, Young-Hun (Department of Prosthodontics, Daejeon Dental Hospital, Wonkwang University) ;
  • Lee, Jin-Han (Department of Prosthodontics, Daejeon Dental Hospital, Wonkwang University)
  • 주용훈 (원광대학교 대전치과병원 보철과) ;
  • 이진한 (원광대학교 대전치과병원 보철과)
  • Received : 2015.10.23
  • Accepted : 2015.12.03
  • Published : 2015.12.31

Abstract

Purpose: The objects of this study was to evaluate the accuracy of the dental stone casts made from alginate impressions according to storage condition and stone pouring time. Materials and Methods: Each of upper and lower impressions of dental model was taken. The dental stone models were made immediately, 10, 30, 60, 180, 360 minutes after the impressions were taken at each storage condition. 3D models were constructed by scanning the stone model using 3D laser scanner. With Reference points, positioned on digital models, linear measurements of the dimensional change were compared by 3D metrology software, 3D average models were made and superimposition to identify the specific site of dimensional change and to measure surface deviation (mm). Results: Dental stone models which were made immediately after taking the impression showed the smallest linear dimensional change. As the stone pouring time was prolonged, the linear dimensional change was increased. More than 180 minutes after impression taking, linear dimensional change and surface distortion increased in the posterior molar region, regardless of the storage condition. Conclusion: For the optimum accuracy of the dental stone casts, alginate impression should be poured as soon as possible. If there were a need for storing, a humidor with 100% relative humidity must be used and be stored less than 180 minutes to fabricate the accurate dental model.

목적: 보관 조건과 석고 주입 시간에 따라 알지네이트 인상체로부터 제작된 모형의 정확성을 알아보고자 하였다. 연구 재료 및 방법: 채득된 알지네이트 인상체는 습도가 유지되는 항습조에 보관하는 것과 진료실 내의 공기 중에 노출되는 상태로 보관 조건을 달리하였다. 보관 조건에 따라 각각 즉시, 채득된 후 10분, 30분, 180분, 360분으로 나누어 보관한 후에 석고 모형을 제작하였다. 제작된 석고 모형을 3D 레이저 스캐너로 삼차원 디지털 모형을 구성하였고 구성된 디지털 모형의 참고점에서 거리를 측정하여 변형률을 비교하였다. 또한 각 실험군의 삼차원 디지털 평균 모형을 제작한 후 중첩을 시행함으로써 표면 변위가 발생한 부위와 크기를 확인하였다. 결과: 인상 채득 즉시 제작한 모형의 변형률이 가장 작게 나타났고, 공기 중에 보관한 인상체보다 항습조에 보관한 인상체의 변형률이 작게 나타났다. 석고 주입 시간이 증가함에 따라서 변형률도 증가하였으며, 석고 주입 시간이 180분을 지나면 보관 조건에 관계없이 대구치 부위에서 변형률과 표면 변위가 증가한다. 결론: 알지네이트 인상체로부터 제작된 모형의 정확성을 위해서는 인상 채득 후, 즉시 모형을 제작해야 한다. 보관이 필요한 경우에는 100% 상대습도가 유지되는 항습조를 이용하고, 보관 시간은 180분을 넘지 않도록 해야 정확한 모형을 얻을 수 있다.

Keywords

References

  1. Anusavice KJ. Phillips' science of dental materials. 12th ed. St. Louis; Elsevier Inc.; 2013. p. 171-6.
  2. Rubel BS. Impression materials: a comparative review of impression materials most commonly used in restorative dentistry. Dent Clin North Am 2007;51:629-42. https://doi.org/10.1016/j.cden.2007.03.006
  3. Donovan TE, Chee WW. A review of contemporary impression materials and techniques. Dent Clin North Am 2004;48:445-70. https://doi.org/10.1016/j.cden.2003.12.014
  4. Nandini VV, Venkatesh KV, Nair KC. Alginate impressions: a practical perspective. J Conserv Dent 2008;11:37-41. https://doi.org/10.4103/0972-0707.43416
  5. Cook W. Alginate dental impression materials: chemistry, structure, and properties. J Biomed Mater Res 1986;20:1-24. https://doi.org/10.1002/jbm.820200103
  6. Sedda M, Casarotto A, Raustia A, Borracchini A. Effect of storage time on the accuracy of casts made from different irreversible hydrocolloids. J Contemp Dent Pract 2008;9:59-66.
  7. Rudd KD, Morrow RM, Bange AA. Accurate casts. J Prosthet Dent 1969;21:545-54. https://doi.org/10.1016/0022-3913(69)90078-X
  8. Eissmann HF, Rudd KD, Morrow RM. Diagnostic procedures. In: Dental laboratory procedures: fixed partial dentures. Vol. 2. St. Louis; Mosby; 1980. p 1-29.
  9. Erbe C, Ruf S, Wostmann B, Balkenhol M. Dimensional stability of contemporary irreversible hydrocolloids: humidor versus wet tissue storage. J Prosthet Dent 2012;108:114-22. https://doi.org/10.1016/S0022-3913(12)60117-6
  10. Walker MP, Burckhard J, Mitts DA, Williams KB. Dimensional change over time of extended-storage alginate impression materials. Angle Orthod 2010;80:1110-5. https://doi.org/10.2319/031510-150.1
  11. Nassar U, Aziz T, Flores-Mir C. Dimensional stability of irreversible hydrocolloid impression materials as a function of pouring time: a systematic review. J Prosthet Dent 2011;106:126-33. https://doi.org/10.1016/S0022-3913(11)60108-X
  12. Johnson GH, Craig RG. Accuracy of four types of rubber impression materials compared with time of pour and a repeat pour of models. J Prosthet Dent 1985;53:484-90. https://doi.org/10.1016/0022-3913(85)90630-4
  13. Wadhwa SS, Mehta R, Duggal N, Vasudeva K. The effect of pouring time on the dimensional accuracy of casts made from different irreversible hydrocolloid impression materials. Contemp Clin Dent 2013;4:313-8. https://doi.org/10.4103/0976-237X.118368
  14. Cohen BI, Pagnillo M, Deutsch AS, Musikant BL. Dimensional accuracy of three different alginate impression materials. J Prosthodont 1995;4:195-9. https://doi.org/10.1111/j.1532-849X.1995.tb00340.x
  15. Oh NS, Seo JM, Kim SH, Youn YA, Shim JS. Agaralginate combined impression technique and dimensional change resulting from idophor disinfection. J Korean Acad Prosthodont 2004;42:21-9.
  16. Alcan T, Ceylanoglu C, Baysal B. The relationship between digital model accuracy and time-dependent deformation of alginate impressions. Angle Orthod 2009;79:30-6. https://doi.org/10.2319/100307-475.1
  17. Sousa MV, Vasconcelos EC, Janson G, Garib D, Pinzan A. Accuracy and reproducibility of 3-dimensional digital model measurements. Am J Orthod Dentofacial Orthop 2012;142:269-73. https://doi.org/10.1016/j.ajodo.2011.12.028
  18. Roesnstiel SF, Land MF, Fujimoto J. Contemporary fixed prosthodontics. 4th ed. St. Louis; Mosby; 2006.
  19. Dreesen K, Kellens A, Wevers M, Thilakarathne PJ, Willems G. The influence of mixing methods and disinfectant on the physical properties of alginate impression materials. Eur J Orthod 2013;35:381-7. https://doi.org/10.1093/ejo/cjs031
  20. Frank RP, Thielke SM, Johnson GH. The influence of tray type and other variables on the palatal depth of casts made from irreversible hydrocolloid impressions. J Prosthet Dent 2002;87:15-22. https://doi.org/10.1067/mpr.2002.121026
  21. Ashley M, McCullagh A, Sweet C. Making a good impression: (a 'how to' paper on dental alginate). Dent Update 2005;32:169-70, 172, 174-5. https://doi.org/10.12968/denu.2005.32.3.169
  22. Sakaguchi RL, Powers JM. Craig's restorative dental materials. 13th ed. Philadelphia; Elsevier Inc.; 2012.
  23. Song KY, Yang JH, Lee SH, Chung HY. A study on dimensional stability of impression materials following immersion disinfection. J Korean Acad Prosthodont 1999;37:506-15.
  24. Nassar U, Hussein B, Oko A, Carey JP, Flores-Mir C. Dimensional accuracy of 2 irreversible hydrocolloid alternative impression materials with immediate and delayed pouring. J Can Dent Assoc 2012;78:c2.
  25. Teeter MG, Naudie DD, McErlain DD, Brandt JM, Yuan X, Macdonald SJ, Holdsworth DW. In vitro quantification of wear in tibial inserts using microcomputed tomography. Clin Orthop Relat Res 2011;469:107-12. https://doi.org/10.1007/s11999-010-1490-6
  26. ADA Council on Scientific Affairs and ADA Council on Dental Practice. Infection control recommendations for the dental office and the dental laboratory. J Am Dent Assoc 1996;127:672-80. https://doi.org/10.14219/jada.archive.1996.0280

Cited by

  1. Accuracy evaluation of dental models manufactured by CAD/CAM milling method and 3D printing method vol.10, pp.3, 2018, https://doi.org/10.4047/jap.2018.10.3.245
  2. 치과용 경석고의 사용방법에 따른 경화팽창과 표면상태 비교연구 vol.38, pp.4, 2016, https://doi.org/10.14347/kadt.2016.38.4.263
  3. 치과위생사의 디지털 구강스캐너 사용에 따른 융합적 교육 요구도 vol.9, pp.5, 2018, https://doi.org/10.15207/jkcs.2018.9.5.069
  4. 디지털 치과모형의 정확도 평가 방법에 대한 고찰 vol.35, pp.2, 2019, https://doi.org/10.14368/jdras.2019.35.2.55
  5. 치과용 3D 프린터로 제작된 임시 수복용 레진의 정확도 평가 vol.19, pp.6, 2019, https://doi.org/10.13065/jksdh.20190094