• Title/Summary/Keyword: implanted

Search Result 1,463, Processing Time 0.028 seconds

The effect of LiF-maleic acid added calcium aluminate hone cement & CA-PMMA composite bone cement on the healing of calvarial defect6) (LiF-maleic acid 첨가 calcium aluminate 골시멘트 및 CA-PMMA 복합 골시멘트가 백서 두개골 결손부 치유에 미치는 영향)

  • Shin, Jung-A;Yun, Jeong-Ho;Oh, Seung-Han;Baik, Jeong-Won;Choi, Se-Young;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.4
    • /
    • pp.753-767
    • /
    • 2002
  • The purpose of this study was to evaluate histologically the effect of LiF-maleic acid added calcium aluminate(LM-CA) bone cement & CA-PMMA composite bone cement on the healing of calvarial defect in Sprague-Dawley rats. The critical size defects were surgically produced in the calvarial bone using the 8mm trephine bur. The rats were divided in three groups : In the control group, nothing was applied into the defect of each rat. LM-CA bone cement was implanted in the experimental group 1 and CA-PMMA composite bone cement was implanted in the experimental group 2. Rats were sacrificed at 2, 8 weeks after surgical procedure. The specimens were examined by histologic analysis, especially about the bone-cement interface and the response of surrounding tissue. The results are as follows; 1. In the control group, inflammatory infiltration was observed at 2 weeks. At 8 weeks, periosteum and duramater were continuously joined together in the defect area. But the center of defect area was filled up with the loose connective tissue. 2. In the experimental group 1, the bonding between implanted bone cement and the existing bone was seen, which more increased in 8 weeks than 2 weeks. Inflammatory infiltration and the dispersion of implanted bone cement particles were seen in both 2 weeks and 8 weeks. 3. In the experimental group 2, implanted bone itself had a dimensional stability and no bonding between implanted bone cement and the existing bone was seen in both 2 weeks and 8 weeks. Implanted bone cement was encapsulated by fibrous connective tissue. In addition, inflammatory infiltration was seen around implanted bone cement. On the basis of these results, when LM-CA bone cement or CA-PMMA composite bone cement was implanted in rat calvarial defect, LM-CA bone cement can be used as a bioactive bone graft material due to ability of bonding to the existing bone and CA-PMMA can be used as a graft material for augmentation of bone-volume due to dimensional stability.

Cutting Characteristics of Plasma Source Son Implanted Tungsten Carbide Tool (플라즈마 이온주입에 의해 표면 개질한 초경공구의 가공특성)

  • Kang, Seong-Ki;Wang, Duck-Hyun;Kim, Won-Il
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.1
    • /
    • pp.33-40
    • /
    • 2010
  • In this research, the effects for surface Improvement of plasma ion implanted carbide endmill tools were observed by measuring cutting forces and tools wear affecting surface roughness in high speed cutting. From the 2nd ion mass analysis, the oxidation layer was found to be built up by sputtering. The residual gas contamination of oxygen was found to be contained impurities in nitrogen gas. The plasma implanted ion was found to be spreaded, especially the nitrogen was implanted up to 150nm depth as impressed voltage and ion implanting time. It is analyzed as bring surface improvement by spreading deeply forming oxidation on surface. The factors in Analysis of Variance(ANOVA) about mutuality cause reference of cutting force. The cutting force Fx is affected by the interaction of spindle rpm and federate, the cutting force Fy is influenced by spindle rpm and time injected ion, and cutting force Fz is affected by the interaction of impressed voltage and feedrate. Also, it was found that the cutting forces of implanted tools become lower and the surface roughness is improved by the effect of nitrogen according to the implantation.

A Study on the Implantation of the Japanese Style Official Residence before 1910 (1910년(年) 이전(以前) 일식관사(日式官舍)의 이식(移植)에 관한 연구(硏究))

  • Ahn, Sung-Ho;Kim, Soon-Il
    • Journal of architectural history
    • /
    • v.6 no.1 s.11
    • /
    • pp.47-65
    • /
    • 1997
  • In the time of the rule of Japanese imperialism, Japanese style official residence played major role at the implantation of modern dwellings into Korea and its influences on Korean modern dwellings are distinguishable. This study focuses on the Japanese style official residence implanted into Korea before 1910. Before 1910 Japanese civilians in Korea builded just a traditional Japanese dwellings at the Japanese settlement in the ports opened. But Japanese engineers engaged in governmental organization of construction in the Old-Korean Empire builded a central corridor type Japanese dwellings as official residence. The central corridor type Japanese dwelling was an urban dwelling compromised between Japanese style and western style and distinguished by an outer-court type plan, Japanese entrance hall, central corridor and western style reception room. It is certified that the central corridor type Japanese dwelling was implanted into Korea before 1910 and this was the first time an urban dwelling to be implanted and spread through the whole Korea. The central corridor type Japanese dwelling implanted into Korea took in On-Dol and transformed to Korea-Japanese eclectic style. The central corridor type Japanese dwellings implanted into Korea in the time of the rule of Japanese imperialism makes function as a precedent of a modern urban dwelling to Korean and makes Korean dwellings transform from the rural inner court type into the urban outer court type.

  • PDF

Biomechanical Analysis of the Artificial Discs (인공디스크에 대한 생체역학적 분석)

  • Kim Young-Eun;Yun Sang-Seok;Jung Sang-Ki
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.907-910
    • /
    • 2005
  • Although several artificial disc designs have been developed for the treatment of discogenic low back pain, biomechanical change with its implantation was rarely studied. To evaluate the effect of artificial disc implantation on the biomechanics of functional spinal unit, nonlinear three-dimensional finite element model of L4-L5 was developed with 1-mm CT scan data. Two models implanted with artificial discs, SB $Charit\acute{e}$ or Prodisc, via anterior approach were also developed. The implanted model predictions were compared with that of intact model. Angular motion of vertebral body, force on spinal ligaments and facet joint, and the stress distribution of vertebral endplate for flexion-extension, lateral bending, and axial rotation with a compressive preload of 400 N were compared. The implanted model showed increased flexion-extension range of motion and increased force in the vertically oriented ligaments, such as ligamentum flavum, supraspinous ligament and interspinous ligament. The increase of facet contact force on extension were greater in implanted models. The incresed stress distribution on vertebral endplate for implanted cases indicated that additinal bone growth around vertebral body and this is matched well with clinical observation. With axial rotation moment, relatively less axial rotation were observed in SB $Charit\acute{e}$ model than in ProDisc model.

  • PDF

Magnetic Properties of Transition Metal-implanted ZnO Nanotips Grown on Sapphire and Quartz

  • Raley, Jeremy A.;Yeo, Yung-Kee;Hengehold, Robert L.;Ryu, Mee-Yi;Lu, Yicheng;Wu, Pan
    • Journal of Magnetics
    • /
    • v.13 no.1
    • /
    • pp.19-22
    • /
    • 2008
  • ZnO nanotips, grown on c-$Al_2O_3$ and quartz, were implanted variously with 200 keV Fe or Mn ions to a dose level of $5{\times}10^{16}cm^{-2}$. The magnetic properties of these samples were measured using a superconducting quantum interference device (SQUID) magnetometer. Fe-implanted ZnO nanotips grown on c-$Al_2O_3$ showed a coercive field width of 209 Oe and a remanent field of 12% of the saturation magnetization ($2.3{\times}10^{-5}emu$) at 300K for a sample annealed at $700^{\circ}C$ for 20 minutes. The field-cooled and the zero-field-cooled magnetization measurements also showed evidence of ferromagnetism in this sample with an estimated Curie temperature of around 350 K. The Mn-implanted ZnO nanotips grown on c-$Al_2O_3$ showed superparamagnetism resulting from the dominance of a spin-glass phase. The ZnO nanotips grown on quartz and implanted with Fe or Mn showed signs of ferromagnetism, but neither was consistent.

Acoustic Characteristics of Some Vowels Produced by the CI Children of Various Age Groups (인공와우 이식 시기에 따른 모음의 음향음성학적 특성)

  • Kim, Go-Eun;Ko, Do-Heung
    • Speech Sciences
    • /
    • v.14 no.4
    • /
    • pp.203-212
    • /
    • 2007
  • This study was to compare some acoustic characteristics of vowels produced by children with cochlear implant (CI) and the children with normal hearing. 20 subjects under ten years old were further classified into two groups (one group of CI children under four years old and the other group of CI children over four years old). For the normal hearing group, 20 subjects are participated in the experiment. Some acoustic parameters including fundamental frequency (F0) and formant frequencies (F1, F2) were measured in the two groups according to the age of cochlear implant operation. For the CI group, three comer vowels (/a/, /i/, /u/) were recorded five times in isolation and analyzed with Multi-Speech (Kay Elemetrics, model 3700), and two independent t-tests on their formant data were conducted using SPSS 11.5. The result showed that the implanted group over four years had a significant difference in F0 and F1 comparing with the implanted group under four years of age as well as the normal hearing group. Those values of the children with the implanted group under four years old were closer to those of the children with the normal hearing. As to the F2, there was no significant difference among implanted groups. However, it was shown that the vowel space for the implanted groups regardless the operation age indicated much smaller than that for the normal hearing children. This acoustic results suggest that CI surgery would be much more effective if it is done under the age of four years old.

  • PDF

WBAN LI Protocol for Improving Lifetime of Implant Sensor in Body (WBAN에서 신체 내부 센서의 라이프타임 향상을 위한 LI 프로토콜)

  • Park, Jinchul;Lee, Jongkyu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.6
    • /
    • pp.18-25
    • /
    • 2014
  • A implanted sensor's error probability is more likely to external sensor's error probability by biological characteristic in WBAN. In this paper, we present method that external sensor transmits frame instead of doing implanted sensor's retransmission for improving lifetime of implanted sensors in WBAN. The proposed method, LI(Lifetime Increment) protocol is to add external sensor's id in transmission data frame of a implanted sensor. When the retransmission is required, external sensor that have to registered id in data frame retransmits frame instead of implanted sensors' retransmission. The comparison result shows that the proposed protocol reduces power consumption and improves life time.

PLASMA SOURCE ION IMPLANTATION OF NITROGEN AND CARBON IONS INTO CO-CEMENTED WC

  • Han, Seung-Hee;Lee, Yeon-Hee;Lee, Jung-Hye;Kim, Hai-Dong;Kim, Gon-Ho;Kim, Yeong-Woo;Cho, Jung-Hee
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.220-220
    • /
    • 1999
  • In plasma source ion implantation, the target is immersed in the plasma and repetitively biased by negative high voltage pulses to implant the extracted ions from plasma into the surface of the target material. In this way, the problems of line-of-sight implantation in ion-beam ion implantation technique can be effectively solved. In addition, the high dose rate and simplicity of the equipment enable the ion implantation a commercially affordable process. In this work, plasma source ion implantation technique was used to improve the wear resistance of Co-cemented WC. which has been extensively used for high speed tools. Nitrogen and carbon ions were implanted using the pulse bias of -602kV, 25 sec and at various implantation conditions. The implanted samples were examined using scanning Auger electron spectroscopy and XPS to investigate the depth distributions of implanted ions and to reveal the chemical state change due to the ion implantation. The implanted ions were found to have penetrated to the depth of 3000$\AA$. The wear resistance of the implanted samples was measured using pin-on-disc wear tester and the wear tracks were examined with alpha-step profilometer.

  • PDF

Evaluation of the rat tissue reaction to experimental new resin cement and mineral trioxide aggregate cement

  • Yang, Won-Kyung;Ko, Hyun-Jung;Kim, Mi-Ri
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.4
    • /
    • pp.194-200
    • /
    • 2012
  • Objectives: New resin cement (NRC) has been developed as a root repairing material and the material is composed of organic resin matrix and inorganic powders. The aim of this study was to compare the rat subcutaneous tissue response to NRC and mineral trioxide aggregate (MTA) cement and to investigate the tissue toxicity of both materials. Materials and Methods: Sixty rats received two polyethylene tube-implants in dorsal subcutaneous regions, MTA and NRC specimens. Twenty rats were sacrificed respectively at 1, 4 and 8 wk after implantation and sectioned to 5 ${\mu}m$ thickness and stained with Hematoxylin-Eosin (H-E) or von-Kossa staining. The condition of tissue adjacent to the implanted materials and the extent of inflammation to each implant were evaluated by two examiners who were unaware of the type of implanted materials in the tissues. Data were statistically analyzed with paired t-test (p < 0.05). Results: In specimens implanted with both NRC and MTA, severe inflammatory reactions were present at one wk, which decreased with time. At eighth wk, MTA implanted tissue showed mild inflammatory reaction, while there were moderate inflammatory reactions in NRC implanted tissue, respectively. In NRC group, von-Kossa staining showed more calcification materials than MTA group at eighth wk. Conclusions: It was concluded that the calcium reservoir capability of NRC may contribute to mineralization of the tissues.

Effects of EMLA Cream Application on Pain Perception and Pain Response of Children with Cancer During Implanted Venous Access Port Needle Insertion (EMLA크림 도포가 소아암환자의 피하매몰 중심정맥포트 바늘삽입 시 통증인지와 통증반응에 미치는 영향)

  • Seo, Hyun-Young;Kim, Young-Hae
    • Child Health Nursing Research
    • /
    • v.22 no.1
    • /
    • pp.21-28
    • /
    • 2016
  • Purpose: The purpose of this study was to identify effects of EMLA (Eutectic Mixture of Local Anesthetics) cream application on pain perception and pain response during insertion of implanted venous access port needle in children with cancer. Methods: From December 2010 to August 2011, at U university hospital, 20 patients scheduled for implanted venous access port needle insertion were recruited, and randomly assigned to receive either EMLA or a placebo cream 1 hour before the implanted venous access port needle insertion. While conducting needle insertion, changes in pulse and oxygen saturation on the pulse oxymeter monitor were measured and pain behavior reaction was also measured during needle insertion in the treatment room. After conducting needle insertion, self-reported pain reaction, and mothers' perception of the children's pain reaction were measured. Collected data were statistically processed using SPSS version 17.0 for Windows, and analyzed using descriptive statistics, t-test. Results: Children's self-reported degree of pain, degree of pain as perceived by mothers and pain behavior reaction decreased significantly in the EMLA application group compared with the placebo group. Conclusion: Findings indicate that application of EMLA cream is effective in relieving pain in these children during implanted venous access port needle insertion.