• Title/Summary/Keyword: imaging volume

Search Result 719, Processing Time 0.027 seconds

Application of T1 Map Information Based on Synthetic MRI for Dynamic Contrast-Enhanced Imaging: A Comparison Study with the Fixed Baseline T1 Value Method

  • Dong Jae Shin;Seung Hong Choi;Roh-Eul Yoo;Koung Mi Kang;Tae Jin Yun;Ji-Hoon Kim;Chul-Ho Sohn;Sang Won Jo;Eun Jung Lee
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1352-1368
    • /
    • 2021
  • Objective: For an accurate dynamic contrast-enhanced (DCE) MRI analysis, exact baseline T1 mapping is critical. The purpose of this study was to compare the pharmacokinetic parameters of DCE MRI using synthetic MRI with those using fixed baseline T1 values. Materials and Methods: This retrospective study included 102 patients who underwent both DCE and synthetic brain MRI. Two methods were set for the baseline T1: one using the fixed value and the other using the T1 map from synthetic MRI. The volume transfer constant (Ktrans), volume of the vascular plasma space (vp), and the volume of the extravascular extracellular space (ve) were compared between the two methods. The interclass correlation coefficients and the Bland-Altman method were used to assess the reliability. Results: In normal-appearing frontal white matter (WM), the mean values of Ktrans, ve, and vp were significantly higher in the fixed value method than in the T1 map method. In the normal-appearing occipital WM, the mean values of ve and vp were significantly higher in the fixed value method. In the putamen and head of the caudate nucleus, the mean values of Ktrans, ve, and vp were significantly lower in the fixed value method. In addition, the T1 map method showed comparable interobserver agreements with the fixed baseline T1 value method. Conclusion: The T1 map method using synthetic MRI may be useful for reflecting individual differences and reliable measurements in clinical applications of DCE MRI.

Three Dimensional Volume Reconstruction of Polyhedral Objects Using X-ray Stereo Images

  • Roh, Young-Jun;Kim, Byung-Man;Cho, Hyung-Suck
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.28.2-28
    • /
    • 2001
  • Three dimensional shape measurement techniques are widely needed in industries for product quality monitoring and control. X-ray imaging method is a promising technology to achieve three-dimensional Information, both the surface and inner structure of an object, since it can overcome the limitations of conventional visual or optical methods such as an occlusion problem or surface reflection properties. In this paper, we propose three dimensional volume reconstruction method based on x-ray stereo imaging technology. Here, the stereo images of an object from two different views are taken by changing the object pose rather than moving imaging plane as in conventional stereo vision method. We propose a series of image processing techniques to extract the features efficiently from x-ray images, where the occluded features in case of normal camera vision could be found ...

  • PDF

Multi-biomarkers-Base Alzheimer's Disease Classification

  • Khatri, Uttam;Kwon, Goo-Rak
    • Journal of Multimedia Information System
    • /
    • v.8 no.4
    • /
    • pp.233-242
    • /
    • 2021
  • Various anatomical MRI imaging biomarkers for Alzheimer's Disease (AD) identification have been recognized so far. Cortical and subcortical volume, hippocampal, amygdala volume, and genetics patterns have been utilized successfully to diagnose AD patients from healthy. These fundamental sMRI bio-measures have been utilized frequently and independently. The entire possibility of anatomical MRI imaging measures for AD diagnosis might thus still to analyze fully. Thus, in this paper, we merge different structural MRI imaging biomarkers to intensify diagnostic classification and analysis of Alzheimer's. For 54 clinically pronounce Alzheimer's patients, 58 cognitively healthy controls, and 99 Mild Cognitive Impairment (MCI); we calculated 1. Cortical and subcortical features, 2. The hippocampal subfield, amygdala nuclei volume using Freesurfer (6.0.0) and 3. Genetics (APoE ε4) biomarkers were obtained from the ADNI database. These three measures were first applied separately and then combined to predict the AD. After feature combination, we utilize the sequential feature selection [SFS (wrapper)] method to select the top-ranked features vectors and feed them into the Multi-Kernel SVM for classification. This diagnostic classification algorithm yields 94.33% of accuracy, 95.40% of sensitivity, 96.50% of specificity with 94.30% of AUC for AD/HC; for AD/MCI propose method obtained 85.58% of accuracy, 95.73% of sensitivity, and 87.30% of specificity along with 91.48% of AUC. Similarly, for HC/MCI, we obtained 89.77% of accuracy, 96.15% of sensitivity, and 87.35% of specificity with 92.55% of AUC. We also presented the performance comparison of the proposed method with KNN classifiers.

Machine Learning-based Prediction of Relative Regional Air Volume Change from Healthy Human Lung CTs

  • Eunchan Kim;YongHyun Lee;Jiwoong Choi;Byungjoon Yoo;Kum Ju Chae;Chang Hyun Lee
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.2
    • /
    • pp.576-590
    • /
    • 2023
  • Machine learning is widely used in various academic fields, and recently it has been actively applied in the medical research. In the medical field, machine learning is used in a variety of ways, such as speeding up diagnosis, discovering new biomarkers, or discovering latent traits of a disease. In the respiratory field, a relative regional air volume change (RRAVC) map based on quantitative inspiratory and expiratory computed tomography (CT) imaging can be used as a useful functional imaging biomarker for characterizing regional ventilation. In this study, we seek to predict RRAVC using various regular machine learning models such as extreme gradient boosting (XGBoost), light gradient boosting machine (LightGBM), and multi-layer perceptron (MLP). We experimentally show that MLP performs best, followed by XGBoost. We also propose several relative coordinate systems to minimize intersubjective variability. We confirm a significant experimental performance improvement when we apply a subject's relative proportion coordinates over conventional absolute coordinates.

Measurement of Prostate Phantom Volume Using Three-Dimensional Medical Imaging Modalities (3차원 의료영상진단기기를 이용한 가상 전립선 용적 측정)

  • Seoung, Youl-Hun;Joo, Yong-Hyun;Choe, Bo-Young
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.4
    • /
    • pp.285-291
    • /
    • 2010
  • Recently, advance on various modalities of diagnosing, prostate volume estimation became possible not only by the existing two-dimension medical images data but also by the three-dimensional medical images data. In this study, magnetic resonance image (MRI), computer tomography (CT) and ultrasound (US) were employed to evaluate prostate phantom volume measurements for estimation, comparison and analysis. For the prostate phantoms aimed at estimating the volume, total of 17 models were developed by using devils-tongue jelly and changing each of the 5ml of capacity from 20ml to 100ml. For the volume estimation through 2D US, the calculation of the diameter with C9-5Mhz transducer was conducted by ellipsoid formula. For the volume estimation through 3D US, the Qlab software (Philips Medical) was used to calculate the volume data estimated by 3D9-3Mhz transducer. Moreover, the images by 16 channels CT and 1.5 Tesla MRI were added by the method of continuous cross-section addition and each of imaginary prostate model's volume was yielded. In the statistical analysis for comparing the availability of volume estimation, the correlation coefficient (r) was more than 0.9 for all indicating that there were highly correlated, and there were not statistically significant difference between each of the correlation coefficient (p=0.001). Therefore, the estimation of prostate phantom volume using three-dimensional modalities of diagnosing was quite closed to the actual estimation.

A Study on the Accuracy of Measurement of Residual Urine Amount depending on the Bladder form using Ultrasonic (초음파를 이용한 Bladder형태에 따른 잔뇨량 측정의 정확도 연구)

  • Kim, Y.M.;Park, T.H.;Kim, J.H.;Kim, S.J.;Hoon, J.D.;Heo, J.Y.;Han, D.G.
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.2
    • /
    • pp.1-7
    • /
    • 2014
  • This study is to increase the accuracy of the diagnosis of benign prostatic hyperplasia by presenting a method that can accurately measure the residual urine amount of the bladder by using an ultrasound image. Agar powder, Propanol and distilled water were used as materials for making a phantom. In order to measure the volume, a $10m{\ell}$ cylinder, syringe and beaker were used. The image was obtained by scanning phantoms produced into six shapes. Each constant value was obtained by using the expression designed to measure the residual urine amount of the bladder and was compared and analyzed. The measuring method of Bladder volume was presented and a constant value for each shape was obtained and five observers measured it five times. According to the results of clinical application, the errors of Ellipse-beanbag, Shield-shield were 11.0%, 18.2%, respectively. Constant values depending on the shape of each phantom were presented in order to accurately measure the volume of the bladder in measuring the amount of residual urine for the diagnosis of benign prostatic hyperplasia. The accuracy of the volume using this was verified statistically(p > 0.05). Therefore, it is considered to be useful in diagnosing benign prostatic hyperplasia by using the ultrasound imaging measuring method presented.

  • PDF

Assessment of Right Ventricular Function in Pulmonary Hypertension with Multimodality Imaging

  • Seo, Hye Sun;Lee, Heon
    • Journal of Cardiovascular Imaging
    • /
    • v.26 no.4
    • /
    • pp.189-200
    • /
    • 2018
  • Pulmonary hypertension (PH) is defined as resting mean pulmonary artery pressure ${\geq}25mmHg$ and is caused by multiple etiologies including heart, lung or other systemic diseases. Evaluation of right ventricular (RV) function in PH is very important to plan treatment and determine prognosis. However, quantification of volume and function of the RV remains difficult due to complicated RV geometry. A number of imaging tools has been utilized to diagnose PH and assess RV function. Each imaging technique including conventional echocardiography, three-dimensional echocardiography, strain echocardiography, computed tomography and cardiac magnetic resonance imaging has-advantages and limitations and can provide unique information. In this article, we provide a comprehensive review of the utility, advantages and shortcomings of the multimodality imaging used to evaluate patients with PH.

How image-processing parameters can influence the assessment of dental materials using micro-CT

  • Torres, Fernanda Ferrari Esteves;Jacobs, Reinhilde;EzEldeen, Mostafa;de Faria-Vasconcelos, Karla;Guerreiro-Tanomaru, Juliane Maria;dos Santos, Bernardo Camargo;Tanomaru-Filho, Mario
    • Imaging Science in Dentistry
    • /
    • v.50 no.2
    • /
    • pp.161-168
    • /
    • 2020
  • Purpose: The aim of this study was to evaluate the influence of voxel size and different post-processing algorithms on the analysis of dental materials using micro-computed tomography (micro-CT). Materials and Methods: Root-end cavities were prepared in extracted maxillary premolars, filled with mineral trioxide aggregate (MTA), Biodentine, and Intermediate Restorative Material (IRM), and scanned using micro-CT. The volume and porosity of materials were evaluated and compared using voxel sizes of 5, 10, and 20 ㎛, as well as different software tools(post-processing algorithms). The CTAn or MeVisLab/Materialise 3-matic software package was used to perform volume and morphological analyses, and the CTAn or MeVisLab/Amira software was used to evaluate porosity. Data were analyzed using 1-way ANOVA and the Tukey test(P<0.05). Results: Using MeVisLab/Materialise 3-matic, a consistent tendency was observed for volume to increase at larger voxel sizes. CTAn showed higher volumes for MTA and IRM at 20 ㎛. Using CTAn, porosity values decreased as voxel size increased, with statistically significant differences for all materials. MeVisLab/Amira showed a difference for MTA and IRM at 5 ㎛, and for Biodentine at 20 ㎛. Significant differences in volume and porosity were observed in all software packages for Biodentine across all voxel sizes. Conclusion: Some differences in volume and porosity were found according to voxel size, image-processing software, and the radiopacity of the material. Consistent protocols are needed for research evaluating dental materials.

Clinical Feasibility of CT Brain Perfusion in a Dog with Sellar Region Tumor

  • Minji Kim;Gunha Hwang;Jeongmin Ryu;Jiwon Yoon;Moon Yeong Choi;Joong-Hyun Song;Tae Sung Hwang;Hee Chun Lee
    • Journal of Veterinary Clinics
    • /
    • v.41 no.3
    • /
    • pp.178-182
    • /
    • 2024
  • A 10-year-old spayed female Poodle was referred for blindness. On ophthalmic examination, loss of bilateral ocular pupil light reflex, visual loss, and right retinal detachment were confirmed at a local hospital. Magnetic resonance imaging (MRI) of the brain was performed to identify the optic nerve, optic chiasm, and brain disease. A sessile mass centered on the region of the optic chiasm was identified. The mass had iso- to hypointense on fluid-attenuated inversion recovery and T2-weighted images and mildly hypointense on T1-weighted images compared to the gray matter, with strong contrast enhancement. Peripheral edema was also identified. Computed tomography (CT) brain perfusion was performed to obtain additional hemodynamic information about the patient using a multislice CT. CT perfusion showed that the cerebral blood volume in the left temporal lobe region (13.4 ± 1.6 mL/100 g) was decreased relative to the contralateral region (19.9 ± 0.3 mL/100 g). The patient showed decreased appetite and consciousness one week after the CT scan with clinical symptoms worsened. The patient had seizure, tetraparesis, and loss of consciousness. It was euthanized one month later at the request of the owner. This report suggests that CT brain perfusion can provide additional hemodynamic information such as insufficient brain perfusion in sellar region tumor which can help assess potential complications and prognosis and plan treatment.

Experimental Approach for Water Discharge Characteristics at PEMFC by using Neutron Imaging Technique considered Neutron Flux and Linear Attenuation Coefficient of Thermal Neutron Correction at NRF, HANARO (중성자속 및 선형 흡수 계수 보정을 고려한 중성자영상법을 이용한 PEMFC 내의 물 배출 특성에 관한 실험적 연구)

  • Kim, Tae-Joo;Kim, Jong-Rok;Kim, Moo-Hwan;Sim, Cheul-Muu
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3418-3422
    • /
    • 2007
  • The neutron imaging technique was used to investigate the water discharge characteristics at PEMFC. Prior to investigation of water discharge characteristics, the linear attenuation coefficient for water at Neutron Radiography Facility (NRF) was calibrated. The feasibility test apparatus was consisted of pressurized air and water in order to simulate the actual operating PEMFC. The feasibility tests have been performed at 1-parallel serpentine type with 100 $cm^2$ active area and different air flow rate (1, 2, and 4 lpm). The total water volume variations at each condition were calculated from the neutron images. The water at channel is well discharged as soon as supplying the pressurized air into the PEMFC. However, because the water at MEA isn't removed the total water volume is constant after 150. Therefore more effective method is needed in order to discharge water at MEA, and the neutron imaging technique is helpful for it.

  • PDF