• Title/Summary/Keyword: human body size

Search Result 493, Processing Time 0.087 seconds

Rapid Detection of Radioactive Strontium in Water Samples Using Laser-Induced Breakdown Spectroscopy (LIBS) (Laser-Induced Breakdown Spectroscopy (LIBS)를 이용한 방사성 스트론튬 오염물질에 대한 신속한 모니터링 기술)

  • Park, Jin-young;Kim, Hyun-a;Park, Kihong;Kim, Kyoung-woong
    • Economic and Environmental Geology
    • /
    • v.50 no.5
    • /
    • pp.341-352
    • /
    • 2017
  • Along with Cs-137 (half-life: 30.17 years), Sr-90 (half-life: 28.8 years) is one of the most important environmental monitoring radioactive elements. Rapid and easy monitoring method for Sr-90 using Laser-Induced Breakdown Spectroscopy (LIBS) has been studied. Strontium belongs to a bivalent alkaline earth metal such as calcium and has similar electron arrangement and size. Due to these similar chemical properties, it can easily enter into the human body through the food chain via water, soil, and crops when leaked into the environment. In addition, it is immersed into the bone at the case of human influx and causes the toxicity for a long time (biological half-life: about 50 years). It is a very reductive and related with the specific reaction that makes wet analysis difficult. In particular, radioactive strontium should be monitored by nuclear power plants but it is very difficult to be analysed from high-cost problems as well as low accuracy of analysis due to complicated analysis procedures, expensive analysis equipment, and a pretreatment process of using massive chemicals. Therefore, we introduce the Laser-Induced Breakdown Spectroscopy (LIBS) analysis method that analyzes the elements in the sample using the inherent spectrum by generating plasma on the sample using pulse energy, and it can be analyzed in a few seconds without preprocessing. A variety of analytical plates for samples were developed to improve the analytical sensitivity by optimizing the laser, wavelength, and time resolution. This can be effectively applied to real-time monitoring of radioactive wastewater discharged from a nuclear power plant, and furthermore, it can be applied as an emergency monitoring means such as possible future accidents at a nuclear power plants.

CT and MRI image fusion reproducibility and dose assessment on Treatment planning system (치료계획시스템에서 전산화단층촬영과 자기공명영상의 영상융합 재현성 및 선량평가)

  • Ahn, Byeong Hyeok;Choi, Jae Hyeok;Hwang, Jae ung;Bak, Ji yeon;Lee, Du hyeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.33-41
    • /
    • 2017
  • Objectives: The aim of this study is to evaluate the reproducibility and usefulness of the images through the fusion of CT(Computed tomography) and MRI(Magnetic resonance imaging) using a self-manufactured phantom. We will also compare and analyze the target dose from acquired images. Materials and Methods: Using a self-manufactured phantom, CT images and MRI images are acquired by 1.5T and 3.0T of different magnetic fields. The reproducibility of the size and volume of the small holes present in the phantom is compared through the image from CT and 1.5T and 3.0T MRI, and dose changes are compared and analyzed on any target. Results: 13 small hole diameters were a maximum 31 mm and a minimum 27.54 mm in the CT scan and the were measured within an average of 29.28 mm 1 % compared to actual size. 1.5 T MRI images showed a maximum 31.65 mm and a minimum 24.3 mm, the average is 28.8 mm, which is within 1 %. 3.0T MRI images showed a maximum 30.2 mm and a minimum 27.92 mm, the average is 29.41 mm, which is within 1.3 %. The dose changes in the target were 95.9-102.1 % in CT images, 93.1-101.4 % in CT-1.5T MRI fusion images, and 96-102 % in CT-3.0T MRI fusion images. Conclusion: CT and MRI are applied with different algorithms for image acquisition. Also, since the organs of the human body have different densities, image distortion may occur during image acquisition. Because these inaccurate images description affects the volume range and dose of the target, accurate volume and location of the target can prevent unnecessary doses from being exposed and errors in treatment planning. Therefore, it should be applied to the treatment plan by taking advantage of the image display algorithm possessed by CT and MRI.

  • PDF

Experimental and epidemiological studies on the life cycle of Echinostoma hortense Asada, 1926(Trematoda: Echinostomatidae) (남한강류역(南漢江流域)의 호르텐스극구흡충(棘口吸蟲) 감염실태(感染實態)와 생활사(生活史)에 관(關)한 연구(硏究))

  • Ahn, Yung-Kyum;Ryang, Yong-Suk
    • Parasites, Hosts and Diseases
    • /
    • v.24 no.2
    • /
    • pp.121-136
    • /
    • 1986
  • Recently there have been some reports on human infections of Echinostoma hortense in Korea. It was found that a few species of freshwater fishes were playing the role of the second intermediate host of E. hortense. However, molluscan intermediate host has not been identified yet in Korea. The present study aimed to establish the life cycle of E. hortense in laboratory. Experimental studies such as egg production from the rat, development of the eggs in vitro, exposure of miracidia to freshwater snails, shedding pattern of cercariae from infected snails, morphology of cercariae, cercarial infection to the second intermediate host and infection of metacercariae to the definitive hosts were done. In addition, epidemiological surveys on the infection status in inhabitants and house rats, and on the natural infection of larval echinostomes in the snails and fishes were carried out along the South Hangang-river. The results obtained were as follows: 1. The eggs deposited from adults in physiological saline were cultivated at room temperature($20{\sim}24^{\circ}C$). The miracidia were firstly observed on 8 days after cultivation, and 85.5% of the eggs contained the mature miracidia on 11 days after cultivation. More than 90% formed the miracidia when cultivated at temperature $22{\sim}27^{\circ}C$. Hatching of the miracidia began on 12 days after cultivation and continued for a week. The size of the miracidia was $103.0{{\times}}51.4{\mu}m$ in average. The motility of the miracidia were active up to 8 hours after shedding, but they were all dead within 10 hours after shedding. 2. A freshwater snail, Radix auricularia coreana was cultivated in aquaria. A hatched $F_1$ snails from the egg masses were exposed to 20 miracidia respectively. Escape of cercariae started on 15 days after infecton. Radix auricularia coreana was experimentally identified as the first intermediate host of E. hortense in Korea. 3. Cercarial shedding started on $15{\sim}20$ days after infection by snail, continued for about 10 days (8.8 days in average). Infected snails were dead within 32 days after the miracidial infection. About 1,335 cercariae($328{\sim}1,994$) per snail were shed in its life, and 119 cercariae in average per snail per day were shed. The cercariae were motile for more than 24 hours, and then squirming at the bottom until death. The body and tail sizes of cercariae were $356{\times}186{\mu}m$ and $510{\times}68{\mu}m$ in average, respectively. The rediae parasitized in the snail hosts were found mainly around the pericardial regions, and their size was $1,575{\times}258{\mu}m$ in average. The numbers of developing cercariae in a mature redia were 14 in average ($7{\sim}20$ in range). The numbers of rediae in a snail were 102 in average on 15 days after miracidial infection and 221 in average on 28 days. 4. Three uninfected Misgurnus anguillicaudatus, less than 6.5cm long were used in for the cercarial infection. They were all exposed with 755 cercariae, and examined at 5-day intervals starting from 10 days after infection. All the fishes were infected with metacercariae of E. hortense and a total of 275 was found infected(36.4%). The metacercariae were fed to rats and the adult worms were obtained on 15 days after infection. 5. The infected rats began to deposit the eggs on 11 days after infection. The number of eggs deposited per day per worm (EPD/worm) was $400{\sim}500$ on 3 weeks after infection and was increased to $1,000{\sim}1,500$ on 4 to 17 weeks, then decreased to 800 on 21 weeks after infection. 6. A total of 745 stool specimens collected from 576 male and 169 female residents of 8 different villages along South Hangang basin was examined. Out of 745 specimens, the eggs of Echinostoma sp. were found in 2 cases (0.3%). Of 34 house rats one showed egg-positive (2.9%). 7. Total 971 Radix auricularia coreana collected from 7 sampling stations were examined for shedding of cercariae. Three snails (0.3%) shed the cercariae of E. hortense. A total of 119 out of 542 freshwater fishes (22.0%) had the metacercariae of E. hortense. The fishes parasitized with the metacercariae were 4 out of 14 examined species. The infection rates of 4 species were 34.1% (106 out of 311) in Misgurnus anguillicaudatus, 30.4% (7 out of 23) in Misgurnus mizolepis, 4.3% (2 out of 46) in Moroco oxycephalus and 22.2% (4 out of 18) in Odontobutis obscura interrupta. In summarizing the above results, the first intermediate host of E. hortense was found as Radix auricularia coreana in Korea. Also, it took about 46 days for the shortest completion of a life cycle of E. hortense in summer; that is, 10 days for miracidial development in eggs, 15 days for cercarial development in the snail, about 10 days for metacercarial development in the second intermediate hosts, and 11 days for the maturation as the adults in the definitive hosts. The natural infection rates of E. hortense in the intermediate hosts were relatively high but those in the definitive hosts were low in the middle areas of South Hangang basin.

  • PDF

A Survey on Consumption Behaviors of the Fast-Foods in University Students (대학생의 패스트푸드 소비행태에 관한 연구)

  • Cho, Kyu-Seok;Im, Byoung-Soon;Kim, Seok-Eun;Kim, Gye-Woong
    • Korean Journal of Human Ecology
    • /
    • v.14 no.2
    • /
    • pp.313-319
    • /
    • 2005
  • This survey was conducted in order to obtain the basic data for desirable consumption habits through investigation and analysis of university students' fast food consumption behaviors. Questionnaires were collected from a total of 374 male and female students living in big or small and medium-sized cities in August, 2004. The contents surveyed were utilization and expenses of fast foods, choice of fast foods, relationship between fast foods and a diet, and characteristics of fast food restaurants. The results obtained are summarized as follows: 1. The ratio of the surveyees varied according to gender, residence, and the size of a city they're living in. For example, males took up 48.66% of the surveyees, while females did 51.34%. The ratio of residents in apartments and stand-alone houses was 54.81% and 45.19% each. 47.33% of the respondents were living in big cities, while 52.67% of them in small and medium-sized cities. 2. 70.1% of the surveyees responded that they are with friends when having fast foods. There was a highly significant difference between male and female in the type of eating companions (p<0.001). The average number of days that they eat fast foods was 1 to 2 times a week, which accounted for 63.7% of the respondents. However, in the case of eating foods, there was no significant differences between two sexes. 3. 64.2% of the surveyees paid more than 20,000 won to buy fast foods for a week, which showed no significant differences between genders. They tend to split a bill, rather than one person pays all. There was a highly significant difference between genders in paying method (p<0.001). 4. 52.1 % of the respondents chose a menu themselves. Their most favored food was chickens (26.5%), which showed a statistically significant difference between genders (p<0.001). 46.8% of them preferred coke as a drink, which had no significant difference between genders. 42.2% of the surveyees had fast foods between lunch and dinner, which also had no significant difference between genders. The most important factor in choosing a menu was its taste (62.8%), which indicated a significant difference between males and females (p<0.05). 5. The preference to fast foods was due to the influence of western culture (36.4%) and eating-out habits (29.1%), which was significantly different between genders (p<0.05). Those who eat fast foods answered they have normal weight and normal body type (49.5%). 24.3% of them were relatively fat with significant difference between genders (p<0.05). 63.4% of the surveyees thought themselves not picky with foods, and there was a significant difference between genders (p<0.05). 78.3% of them mostly preferred franchise restaurants because they are convenient and cheap.

  • PDF

A Deep Learning Based Approach to Recognizing Accompanying Status of Smartphone Users Using Multimodal Data (스마트폰 다종 데이터를 활용한 딥러닝 기반의 사용자 동행 상태 인식)

  • Kim, Kilho;Choi, Sangwoo;Chae, Moon-jung;Park, Heewoong;Lee, Jaehong;Park, Jonghun
    • Journal of Intelligence and Information Systems
    • /
    • v.25 no.1
    • /
    • pp.163-177
    • /
    • 2019
  • As smartphones are getting widely used, human activity recognition (HAR) tasks for recognizing personal activities of smartphone users with multimodal data have been actively studied recently. The research area is expanding from the recognition of the simple body movement of an individual user to the recognition of low-level behavior and high-level behavior. However, HAR tasks for recognizing interaction behavior with other people, such as whether the user is accompanying or communicating with someone else, have gotten less attention so far. And previous research for recognizing interaction behavior has usually depended on audio, Bluetooth, and Wi-Fi sensors, which are vulnerable to privacy issues and require much time to collect enough data. Whereas physical sensors including accelerometer, magnetic field and gyroscope sensors are less vulnerable to privacy issues and can collect a large amount of data within a short time. In this paper, a method for detecting accompanying status based on deep learning model by only using multimodal physical sensor data, such as an accelerometer, magnetic field and gyroscope, was proposed. The accompanying status was defined as a redefinition of a part of the user interaction behavior, including whether the user is accompanying with an acquaintance at a close distance and the user is actively communicating with the acquaintance. A framework based on convolutional neural networks (CNN) and long short-term memory (LSTM) recurrent networks for classifying accompanying and conversation was proposed. First, a data preprocessing method which consists of time synchronization of multimodal data from different physical sensors, data normalization and sequence data generation was introduced. We applied the nearest interpolation to synchronize the time of collected data from different sensors. Normalization was performed for each x, y, z axis value of the sensor data, and the sequence data was generated according to the sliding window method. Then, the sequence data became the input for CNN, where feature maps representing local dependencies of the original sequence are extracted. The CNN consisted of 3 convolutional layers and did not have a pooling layer to maintain the temporal information of the sequence data. Next, LSTM recurrent networks received the feature maps, learned long-term dependencies from them and extracted features. The LSTM recurrent networks consisted of two layers, each with 128 cells. Finally, the extracted features were used for classification by softmax classifier. The loss function of the model was cross entropy function and the weights of the model were randomly initialized on a normal distribution with an average of 0 and a standard deviation of 0.1. The model was trained using adaptive moment estimation (ADAM) optimization algorithm and the mini batch size was set to 128. We applied dropout to input values of the LSTM recurrent networks to prevent overfitting. The initial learning rate was set to 0.001, and it decreased exponentially by 0.99 at the end of each epoch training. An Android smartphone application was developed and released to collect data. We collected smartphone data for a total of 18 subjects. Using the data, the model classified accompanying and conversation by 98.74% and 98.83% accuracy each. Both the F1 score and accuracy of the model were higher than the F1 score and accuracy of the majority vote classifier, support vector machine, and deep recurrent neural network. In the future research, we will focus on more rigorous multimodal sensor data synchronization methods that minimize the time stamp differences. In addition, we will further study transfer learning method that enables transfer of trained models tailored to the training data to the evaluation data that follows a different distribution. It is expected that a model capable of exhibiting robust recognition performance against changes in data that is not considered in the model learning stage will be obtained.

Shelf-life and Quality Characteristics of Tofu Coagulated by Calcium Lactate (젖산칼슘을 응고제로 한 두부의 품질특성과 저장성)

  • 이명예;김순동
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.2
    • /
    • pp.412-419
    • /
    • 2004
  • To investigate the utilization of calcium lactates (CaL) as coagulants for tofu manufacture, the quality characteristics and shelf-life of tofu made by CaL-P (black snail powder) and CaL-A (black snail ash) were investigated and compared to calcium chloride (CC), magnesium chloride (MC), calcium sulfate (CS ) and standard calcium lactate (CaL-S). And also, total microbe and turbidity of the tofu were determined during storage at 1$0^{\circ}C$. Coagulation ability of CaL-A was the highest, and the ability of CaL-P was higher than that of CaL-S. Yield of CaL-A tofu was similar to those of CS and CC tofu, while the yield of CaL-P tofu was 50% compared to that of CC. L* value of CaL-P tofu was lower, but a* and b* values were higher than those of other tofus. The hardness of tofu showed in the order of CaL-S>CS>CC>CaL-P>MC>CaL-A, while the cohesiveness showed in the order of MC>CaL-S>CC>CS>CaL-P>CaL-A. Calcium contents were 57 mg% in MC tofu, 174 mg% in CS tofu, 116 mg% in CaL-S tofu, 95 mg% in CaL-A tofu and 172 mg% in CaL-P tofu. From the results of microscopic observations, the lower hardness showed the more soft and the smaller particle. The particle of CaL-A tofu was small and uniformity but the size of CaL-P and CC tofu showed coarse. Sensory quality of CaL-P and -A tofu were better than the other tofu evaluated by texture, springiness, flavor and overall taste. The shelf-life estimated by total microbe was 4∼6 days in CC, MC, CS, CaL-S and CaL-A tofu, but 8 days in CaL-P tofu at 1$0^{\circ}C$. From the above results, the CaL-P and -A may believe to use as coagulant for tofu manufacture due to its softened taste and enhanced shelf-life, and higher calcium content which has higher absorbability in human body.

A Low-Dose High-Resolution SPECT System with CdTe for Small-Animal Imaging Applications: A GATE Simulation Study (GATE 시뮬레이션을 통한 고해상도 저선량용 소동물 영상화를 위한 CdTe 검출기 기반의 SPECT 기기 연구)

  • Park, Su-Jin;Yu, A Ram;Kim, Yeseul;Lee, Young-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.162-170
    • /
    • 2013
  • Dedicated single-photon emission computed tomography (SPECT) systems based on pixelated semiconductors are being developed for studying small animal models of human disease. To clarify the possibility of using a SPECT system with CdTe for a high resolution low-dose small animal imaging, we compared the quality of reconstructed images from pixelated CdTe detector to those from a small SPECT system with NaI(Tl). The CdTe detector was $44.8{\times}44.8$ mm and the pixels were $0.35{\times}0.35{\times}5$ mm. The intrinsic resolution of the detector was 0.35 mm, which is equal to the pixel size. GATE simulations were performed to assess the image quality of both SPECT systems. The spatial resolutions and sensitivities for both systems were evaluated using a 10 MBq $^{99m}Tc$ point source. The quantitative comparison with different injected dose was performed using a voxelized MOBY phantom, and the absorbed doses for each organ were evaluated. The spatial resolution of the SPECT with NaI(Tl) was about 1.54 mm FWHM, while that of the SPECT with a CdTe detector was about 1.32 mm FWHM at 30 mm. The sensitivity of NaI(Tl) based SPECT was 83 cps/MBq, while that of the CdTe detector based SPECT was 116 cps/MBq at 30 mm. The image statistics were evaluated by calculating the CNR of the image from both systems. When the injected activity for the striatum in the mouse brain was 160 Bq/voxel, the CNR of CdTe based SPECT was 2.30 while that of NaI(Tl) based SPECT was 1.85. The CNR of SPECT with CdTe was overall higher than that of the NaI(Tl) based SPECT. In addition, the absorbed dose was higher from SPECT with CdTe than those from NaI(Tl) based SPECT to acquire the same quantitative values. Our simulation results indicated that the SPECT with CdTe detector showed overall high performance compared to the SPECT with NaI(Tl). Even though the validation study is needed, the SPECT system with CdTe detector appeared to be feasible for high resolution low-dose small animal imaging.

A Study on the dose distribution produced by $^{32}$ P source form in treatment for inhibiting restenosis of coronary artery (관상동맥 재협착 방지를 위한 치료에서 $^{32}$ P 핵종의 선원 형태에 따른 선량분포에 관한 연구)

  • 김경화;김영미;박경배
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 1999
  • In this study, the dose distributions of a $^{32}$ p uniform cylindrical volume source and a surface source, a pure $\beta$emitter, were calculated in order to obtain information relevant to the utilization of a balloon catheter and a radioactive stent. The dose distributions of $^{32}$ p were calculated by means of the EGS4 code system. The sources are considered to be distributed uniformly in the volume and on the surface in the form of a cylinder with a radius of 1.5 mm and length of 20 mm. The energy of $\beta$particles emitted is chosen at random in the $\beta$ energy spectrum evaluated by the solution of the Dirac equation for the Coulomb potential. Liquid water is used to simulate the particle transport in the human body. The dose rates in a target at a 0.5mm radial distance from the surface of cylindrical volume and surface source are 12.133 cGy/s per GBq (0.449 cGy/s per mCi, uncertainty: 1.51%) and 24.732 cGy/s per GBq (0.915 cGy/s per mCi, uncertainty: 1.01%), respectively. The dose rates in the two sources decrease with distance in both radial and axial direction. On the basis of the above results, the determined initial activities were 29.69 mCi and 1.2278 $\mu$Ci for the balloon catheter and the radioactive stent using $^{32}$ P isotope, respectively. The total absorbed dose for optimal therapeutic regimen is considered to be 20 Gy and the treatment time in the case of the balloon catheter is less than 3 min. Absorbed doses in targets placed in a radial direction for the two sources were also calculated when it expressed initial activity in a 1 mCi/ml volume activity density for the cylindrical volume source and a 0.1 mCi/cm$^2$ area activity density for the surface source. The absorbed dose distribution around the $^{32}$ P cylindrical source with different size can be easily calculated using our results when the volume activity density and area activity density for the source are known.

  • PDF

Comparison of the SNR in the MR images on dental implant material (치아 임플란트 재료에 따른 자기공명영상의 SNR 비교)

  • Kim, Dong-Hyun;Ko, Seong-Jin;Ye, Soo-Young
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.4
    • /
    • pp.149-155
    • /
    • 2015
  • Tooth implant is located in oral cavity and affects neck, skull base, and facail image. These magnetic inhomogeneities are usually frequency encoding direction which cause artifacts due to change of signal strength and geometric distortion. First, to evaluate signal to noise ratio (SNR) of magnetic resonance image caused by tooth implant this study uses meat phantom which is similar to human body and is consisted with fat, muscle, and water to measure signal to noise ratio. Second, signal to noise ratio by using custom-made fixed phantom is measured, and then signal to noise ratio size of different tooth implant types is compared and analyzed. The measured signal to noise ratio values of Brushite, HSA, Metal, and RBM for meat phantom were 2.76, 2.22, 1.88, and 1.57 on T1 SE, 1.88, 1.78, 1.65, and 1.79 on T2 FLAIR, 2.28, 2.25, 2.88, and 2.05 on T2 FSE, and 2.74, 1.94, 1.67, and 1.48 on T2 GRE. The measured signal to noise ratio values of Brushite, HSA, Metal, and RBM for fixed water phantom were 1.2, 1.06, 1.12, and 1.22 on DWI, 1.93, 1.87, 1.93, and 2.06 T1 SE, 1.83, 1.76, 1.82, and 1.92 on T2 FLAIR, 1.85, 1.79, 7.86, and 1.97 on T2 FSE, and 1.97, 1.93, 1.99, and 2.06 on T2 GRE. By considering through the results, patients and dentists need to consider some impacts from testing many aspects although their main purpose of having tooth implants is a dental restoration. Moreover, depending on the tooth implant characteristics of individual patients this study results can be used as baseline data when choosing test protocol.

A prediction study on the number of emergency patients with ASTHMA according to the concentration of air pollutants (대기오염물질 농도에 따른 천식 응급환자 수 예측 연구)

  • Han Joo Lee;Min Kyu Jee;Cheong Won Kim
    • Journal of Service Research and Studies
    • /
    • v.13 no.1
    • /
    • pp.63-75
    • /
    • 2023
  • Due to the development of industry, interest in air pollutants has increased. Air pollutants have affected various fields such as environmental pollution and global warming. Among them, environmental diseases are one of the fields affected by air pollutants. Air pollutants can affect the human body's skin or respiratory tract due to their small molecular size. As a result, various studies on air pollutants and environmental diseases have been conducted. Asthma, part of an environmental disease, can be life-threatening if symptoms worsen and cause asthma attacks, and in the case of adult asthma, it is difficult to cure once it occurs. Factors that worsen asthma include particulate matter and air pollution. Asthma is an increasing prevalence worldwide. In this paper, we study how air pollutants correlate with the number of emergency room admissions in asthma patients and predict the number of future asthma emergency patients using highly correlated air pollutants. Air pollutants used concentrations of five pollutants: sulfur dioxide(SO2), carbon monoxide(CO), ozone(O3), nitrogen dioxide(NO2), and fine dust(PM10), and environmental diseases used data on the number of hospitalizations of asthma patients in the emergency room. Data on the number of emergency patients of air pollutants and asthma were used for a total of 5 years from January 1, 2013 to December 31, 2017. The model made predictions using two models, Informer and LTSF-Linear, and performance indicators of MAE, MAPE, and RMSE were used to measure the performance of the model. The results were compared by making predictions for both cases including and not including the number of emergency patients. This paper presents air pollutants that improve the model's performance in predicting the number of asthma emergency patients using Informer and LTSF-Linear models.