• Title/Summary/Keyword: high current cable

Search Result 301, Processing Time 0.028 seconds

Partial Discharge Characteristics in LLDPE-Natural Rubber Blends: Correlating Electrical Quantities with Surface Degradation

  • Aulia, Aulia;Ahmad, Mohd Hafizi;Abdul-Malek, Zulkurnain;Arief, Yanuar Z.;Lau, KwanYiew;Novizon, Novizon
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.699-706
    • /
    • 2016
  • Partial discharges (PD) lead to the degradation of high voltage cables and accessories. PD activities occur due to the existence of impurities, voids, contaminants, defects and protrusions during the manufacture and installation of power cables. Commonly, insulation failures occur at cable joints and terminations, caused by inhomogeneous electric field distributions. In this work, a blend of natural rubber (NR) and linear low density polyethylene (LLDPE) was investigated, and the optimal formulation of the blend that could resist PD was discussed. The experiments were conducted under a constant high voltage stress test of 6.5 kV AC and the magnitude of partial discharge activities was recorded using the CIGRE method II. Pattern analysis of PD signals was performed along with the interpretation of morphological changes. The results showed that the addition of 10 wt% of NR and 5 wt% of Alumina Trihydrate (ATH) provided promising results in resisting PD activities. However, as the NR content increased, more micropores existed, thus resulting in increased PD activities within the samples.

Analysis on the Actual Wearing Conditions and Preferences of the Knit Wear School Uniforms of High School Girls (여고생 니트웨어 교복의 착용 실태 및 선호도 분석)

  • Suh, Mi-Young;Kim, Soon-Ah
    • The Research Journal of the Costume Culture
    • /
    • v.17 no.2
    • /
    • pp.352-366
    • /
    • 2009
  • The purpose of this study was to investigate the actual wearing conditions and the preferences of knit wear school uniforms. The subjects were 480 high school girls from 6 high schools placed in Daejeon. The method of study is a survey consisted of actual wearing conditions questionnaires, preferences questionnaires, and demographic attribution. Data was analyzed by frequency, variance, crosstabs, and correlation analysis using SPSS 12.0 program. The results of study are as follows. First, high school girls over 90% wearing knit wear school uniforms were satisfied with current knit wear school uniforms(navy color, V-neck, and wool mixed). Second, high school girls preferred 100% cotton material and black/white/gray color group. The style of knit wear school uniforms was most preferred monochrome cardigan with cable pattern. High school girls wanted to show neat image by knit wear school uniforms and to diversify the style of them. Third, the differences of preferences between groups, they were wearing knit wear school uniforms(A group) or not(B group), were about pattern and improvement. A group preferred school mark pattern, and wanted to improve the quality and after service. B group preferred monochrome cable pattern, and wanted to diversify the style. Both groups wanted to wear knit wear school uniforms because knit wear was 'warm' and 'comfort'. Consequently, knit wear school uniforms will help high school girls express individuality and beauty.

  • PDF

Condition Monitoring System: High Performance Wireless Measurement System (기계 상태 감시: 임베디드형의 고성능 무선 측정시스템)

  • Shim, M.C.;Yang, B.S.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.28-32
    • /
    • 2007
  • This research proposed that development of wireless condition monitoring system using WLAN network. It offers the prospect of improved performance that removed a current a coaxial cable and reduced overall cost of condition monitoring. Recently, there is an interesting concern for wireless system as an infrastructure technology construct ubiquitous computing environment in the future. High performance computing board makes minimization with integrate of a various functions which support wireless LAN network. Instead of wired coaxial cable using measurement system in industry, wireless LAN network assists industry automation and engineer's convenience. Developed system adapted wireless LAN network on shipboard with engine room and deck house, it also executes wireless measurement test on 8500TEU containership.

  • PDF

Contact-less Power Supply Using Series-Parallel Rasonant Converter ($\cdot$병렬 공진형컨버터를 이용한 비접촉전원)

  • Kim E. S.;Goo D. H.;Kim J. M.;Kang D. H.;Shin B. C.;Kong Y. S.;Yang S. C.
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.103-107
    • /
    • 2002
  • A contact-less power supply system (CPS) allows electrical energy to supply to mobile consumers without any electrical or mechanical contact. CPS works in the same principle as a transformer, with the track litz cable forming the primary circuit and the pickup as the secondary. The track power supply generates the high frequency alternating current in the track cable. The captured AC magnetic field generated by the track conductors produces electrical energy in the pickup coil and the pickup rectifier converts the high frequency AC power to DC while regulating the power to the load. This paper presents the theoretical analysis, simulation and experiment리 results of the series-parallel resonant converter working as contact-less power supply system.

  • PDF

AC loss comparison of Bi-2223 and coated conductor HTS tapes under bending

  • Kim, Hae-Joon;Cho, Jeon-Wook;Sim, Ki-Deok;Kim, Jae-Ho;Kim, Seok-Ho;Jang, Hyun-Man;Lee, Soo-Gil
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.4
    • /
    • pp.41-45
    • /
    • 2007
  • Superconductor is developed for applications in high-power devices such as power-transmission cables, transformers, motor and generators. In such applications, HTS tapes are subjected to various kinds of stress or strain. AC loss is also important consideration for many large-scale superconducting devices. In the fabrication of the devices, the critical current $(I_c)$ of the high temperature superconductor degrades due to many reasons including the tension applied by bending and thermal contraction. These bending or tension reduces the $I_c$ of superconducting wire and the $I_c$ degradation affects the AC loss of the wire. The $I_c$ degradation and AC loss (self field loss) of Bi-2223 HTS and Coated conductor were measured under tension and bending conditions at 77K and self-field.

Electrical Conduction and Resistance Characteristics of Styrene Butadiene Rubber (SBR) Composites Containing Carbon Black (Styrene Butadiene Rubber (SBR)/ Carbon Black 복합체의 전기저항 및 전기전도 특성)

  • Kim, Do-Hyun;Lee, Jung-Hee;Sohn, Ho-Soung;Lee, Kyung-Won
    • Elastomers and Composites
    • /
    • v.33 no.4
    • /
    • pp.246-254
    • /
    • 1998
  • In order to investigate the characteristics of resistance and conduction of vulcanized styrene butadiene rubber (SBR)/ carbon black (CB) composites, surface/ volume resistivity, point to point resistance, decay time, and electrical conduction experiments with four different kinds of non-conductive carbon black were measured. When about 50phr of carbon black were loaded in SBR, all resistivites suddenly decreased and critical region (Rc) was shown. Current densities of SBR/CB composites showed critical point (Pc) and increased with the electric fields. Electrical conduction mechanisms of SBR/CB composites could be considered as the ohmic conduction at low electric fields and the space charge limited conduction (SCLC) at high electric fields, respectively.

  • PDF

Implementation of Power Cable Diagnostic Simulator using VLF (VLF를 활용한 전력케이블 진단 시뮬레이터 구현)

  • Kim, Kuk;Eo, Ik-soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.593-602
    • /
    • 2020
  • Power cables installed in domestic factories or underground can cause accidents depending on the manufacturing process, installation, and environmental conditions during use. When an accident occurs in a power cable, it can cause enormous economic loss and social confusion. Hence, the importance of preventive management of the cable through diagnosis is increasing to prevent it. Therefore, in this paper, a diagnostic sample cable was produced by simulating a part that could be a problem due to the installation, manufacturing defects, or deterioration of cables that can occur in the field. Dielectric loss Tangent (tan 𝛿; TD), and Partial Discharge(PD) tests were performed. Partial discharge and AC (60Hz) withstand voltage equipment using High-Frequency Current Transformer (HFCT) were applied After applying a VLF (Very Low Frequency) power supply with a frequency of 0.1Hz was applied. As a result, B and C phase defect samples at a 2.0U0 voltage through the VLF could measure the internal partial discharge in the A-phase normal sample cable from the noise at a 0.5U0 to 2.0U0 voltage. In addition, the 1.5U0 voltage was measured through the AC (60Hz) withstand voltage equipment of the commercial frequency to verify its effectiveness. Partial discharge in the run-off state was measured at a voltage of 1.0U0, and there was a risk when installing the equipment. AC power equipment showed a difficulty of movement by volume or weight. The diagnostic method, through the VLF of the quadrant state, revealed its safety and effectiveness.

Application of Pulsed Power with the High Voltage & current for Rock Fragmentation (고전압.대전류폴스파워를 이용한 암반발파 모의 기술개발)

  • Seo, Kil-Soo;Kim, Young-Bae;Lee, Hyeong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1592-1595
    • /
    • 1998
  • The rock fragmentation system with a capacitor bank, switching device, cable and blasting electrode are described. Utilization of the chemical energy from the electrolyte and the pseudospark with a large current capacity suggested the commercialization possibility of the rock fragmentation system. The vibration and noise level of the pulsed blasting is acceptable in the most ground breaking. And also the electromagnetic force produced by the inductor is introduced for the rock fragmentation.

  • PDF

Magnetic field Reduction characteristics of shielding wear for a worker by using AC Arc welder. (교류 아크용접기를 사용하는 작업자의 차폐복 자계저감 특성검토)

  • Park, Jun-Hyeong;Min, Suk-Won
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1343-1344
    • /
    • 2008
  • This paper analyses current densities induced inside a worker using AC arc welder when he wears a protective cloth. Applying the boundary element method, we calculate current densities induced in organs inside a worker in case he was located at 1[cm], 15[cm], 20[cm] far from a power cable of AC arc welder. As results of study, we find a maximum current density induced in all organs may be lower than 10[$mA/cm^2$] if he wears a protective cloth. We also know high permeability materials can lower current density more than high conductivity materials.

  • PDF

Mechanical Performance Study of Piggy Back Clamp for Submarine Cables (해저케이블용 피기백 클램프의 기계적 성능 연구)

  • Yun Jae Kim;Kyeong Soo Ahn;Jin-wook Choe;Jinseok Lim;Sung Woong Choi
    • Composites Research
    • /
    • v.37 no.2
    • /
    • pp.108-114
    • /
    • 2024
  • Due to the continuously increasing global demand for electricity, the demand for high-voltage submarine cables is also increasing. One of the issues that need to be addressed for submarine cables is the high production cost and expensive laying costs. Submarine cables exposed to the marine environment encounter external forces such as wave and current, leading to issues such as cable damage due to external factors or high maintenance costs in the event of an accident. Therefore, we are preparing for the uncertainty of the submarine environment through many protective materials and protective equipment. In this study, we examined the bending performance of piggyback clamps (PBC) and strap, which are representative protective equipment, in response to the submarine environment through analytical methods. To examine the structural performance of PBC, the bending performance were assessed under the maximum bending moment criterion of 15 kN·m for the flexible protection tube. As a result, it was confirmed that the structural performance regarding the bending moment of both PBC and straps was ensured.