Magnetic field Reduction characteristics of shielding wear for a worker by using AC Arc welder.

교류 아크용접기를 사용하는 작업자의 차폐복 자계저감 특성검토

  • Park, Jun-Hyeong (Department of Electrical and Communication System Engineering, Soonchunhyang University) ;
  • Min, Suk-Won (Department of Electrical and Communication System Engineering, Soonchunhyang University)
  • 박준형 (순천향대 전기통신시스템공학과) ;
  • 민석원 (순천향대 전기통신시스템공학과)
  • Published : 2008.07.16

Abstract

This paper analyses current densities induced inside a worker using AC arc welder when he wears a protective cloth. Applying the boundary element method, we calculate current densities induced in organs inside a worker in case he was located at 1[cm], 15[cm], 20[cm] far from a power cable of AC arc welder. As results of study, we find a maximum current density induced in all organs may be lower than 10[$mA/cm^2$] if he wears a protective cloth. We also know high permeability materials can lower current density more than high conductivity materials.