• Title/Summary/Keyword: high SNR

Search Result 675, Processing Time 0.028 seconds

Performance Evaluation of Reconstruction Algorithms for DMIDR (DMIDR 장치의 재구성 알고리즘 별 성능 평가)

  • Kwak, In-Suk;Lee, Hyuk;Moon, Seung-Cheol
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.29-37
    • /
    • 2019
  • Purpose DMIDR(Discovery Molecular Imaging Digital Ready, General Electric Healthcare, USA) is a PET/CT scanner designed to allow application of PSF(Point Spread Function), TOF(Time of Flight) and Q.Clear algorithm. Especially, Q.Clear is a reconstruction algorithm which can overcome the limitation of OSEM(Ordered Subset Expectation Maximization) and reduce the image noise based on voxel unit. The aim of this paper is to evaluate the performance of reconstruction algorithms and optimize the algorithm combination to improve the accurate SUV(Standardized Uptake Value) measurement and lesion detectability. Materials and Methods PET phantom was filled with $^{18}F-FDG$ radioactivity concentration ratio of hot to background was in a ratio of 2:1, 4:1 and 8:1. Scan was performed using the NEMA protocols. Scan data was reconstructed using combination of (1)VPFX(VUE point FX(TOF)), (2)VPHD-S(VUE Point HD+PSF), (3)VPFX-S (TOF+PSF), (4)QCHD-S-400((VUE Point HD+Q.Clear(${\beta}-strength$ 400)+PSF), (5)QCFX-S-400(TOF +Q.Clear(${\beta}-strength$ 400)+PSF), (6)QCHD-S-50(VUE Point HD+Q.Clear(${\beta}-strength$ 50)+PSF) and (7)QCFX-S-50(TOF+Q.Clear(${\beta}-strength$ 50)+PSF). CR(Contrast Recovery) and BV(Background Variability) were compared. Also, SNR(Signal to Noise Ratio) and RC(Recovery Coefficient) of counts and SUV were compared respectively. Results VPFX-S showed the highest CR value in sphere size of 10 and 13 mm, and QCFX-S-50 showed the highest value in spheres greater than 17 mm. In comparison of BV and SNR, QCFX-S-400 and QCHD-S-400 showed good results. The results of SUV measurement were proportional to the H/B ratio. RC for SUV is in inverse proportion to the H/B ratio and QCFX-S-50 showed highest value. In addition, reconstruction algorithm of Q.Clear using 400 of ${\beta}-strength$ showed lower value. Conclusion When higher ${\beta}-strength$ was applied Q.Clear showed better image quality by reducing the noise. On the contrary, lower ${\beta}-strength$ was applied Q.Clear showed that sharpness increase and PVE(Partial Volume Effect) decrease, so it is possible to measure SUV based on high RC comparing to conventional reconstruction conditions. An appropriate choice of these reconstruction algorithm can improve the accuracy and lesion detectability. In this reason, it is necessary to optimize the algorithm parameter according to the purpose.

A Study on High-Resolution Technique in MRI Scan for Cerebral Aneurysm Disease -Comparison between High-Resolution Technique and Standard Technique- (뇌 동맥류 질환 자기공명검사에서 고분해능(High-Resolution) 기법의 관한 연구 - 고분해능기법과 표준기법 비교 -)

  • Choi, Sung-Hyun;Goo, Eun-Hoe;Hwang, Sun-Kwang;Lee, Gang-Won;Lee, Jong-Woong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.1
    • /
    • pp.7-12
    • /
    • 2012
  • The purpose of this study was to examine usefulness of 3T equipment-based time-of-flight magnetic resonance angiography (3T-TOF MRA) by comparing standard technique (ST) with high resolution technique (HRT) in evaluation of cerebral blood vessel. The 3T-TOF MRA was performed for 31 patients who were suspected of having cerebrovascular disease from March to July 2010. For evaluation of cerebral blood vessel, classification was conducted randomly: group I that included vertebral artery and basilar artery, group II that ranged from 2.5cm before basin part of common carotid artery to basin part of internal and external carotid arteries and to genu part of internal carotid artery, group III that ranged from vertebral part of internal carotid artery to the first basin art of anterior and middle cerebral through education recognizes the importance of dose reduction and examine if their efforts and further reduce patient dose could achieve optimization of the medical exposure is considered.

  • PDF

Research of Sea Food Wastewater Treatment using Membrane Filter (Membrane Filter를 이용한 수산물 가공폐수처리에 대한 연구)

  • Han, Dong-Joon
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.4
    • /
    • pp.119-130
    • /
    • 2007
  • Sea food wastewater including high concentration of organics and nutrients is hard to treat stably by established traditional activated sludge process. This research is aimed to obey more and more of strengthened the law and to secure stable effluents by using advanced treatment process applied membrane filter in aeration tank for treatment of wastewater from marine products. It must maintain pH of influent over 6.0 to keep up stably biological sludge of advanced treatment process. At 38hr of HRT, removal rates of TBOD and TCOD were 99.9% and 99.4% respectively and TSS also removed with high efficiency. Most organics in the effluent was constituted with soluble type materials, it caused that membrane filter installed aeration tank should remove minute suspended particles. The reactor was operated well to get stable treatment results for operation period, in spite of high loading of organics like that $0.67{\sim}1.67\;kgTBOD/m^3/day$ of organics loading and $0.10{\sim}0.21\;kgBOD_5/kgMLSS/day$ of F/M ratio. At $36{\sim}48hr$ of HRT, removal rates of T-N and T-P were $89.7{\sim}90.7%\;and\;91.5{\sim}96.0%$ respectively. It means this treatment process also work to remove nutrients of high concentration. Upon investigation of advanced treatment's operation factors, optimum SRT was about 30days and average SNR that showed tendency to increase according to increase water temperature was calculated 0.014 gN/g MLVSS/d. SDNR was risen in conformity to increase F/M ratio of Non-aeration tank and investigated as $0.038{\sim}0.051\;gN/gMLVSS/d$.

Antenna Selection Scheme Using Noncoherent Receivers for Off-Body High Data Rate WBAN (신체 외부 고속 통신에서 Noncoherent 수신기 기반의 안테나 선택 기법)

  • Park, Jong-Seok;Hwang, Jae-Ho;Jang, Sung-Jeen;Kim, Jae-Moung;Lee, Hyung-Soo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.6
    • /
    • pp.88-97
    • /
    • 2009
  • As the development of wireless techniques, transmission technology of body area network plays an important role in realizing a welfare society by combining IT and BT when applying to vehicles. Off-body WBAN (Wireless Body Area Network) systems for video data transmission require low battery consumption and high data rate. To satisfy the requirement, UWB has been considered as a promising candidate for high rate WBAN. This paper introduces an antenna selection technique for ultra-wideband based off-body WBAN system with low complexity. In this paper, we propose an antenna selection scheme using non-coherent receiver for off-body high data rate WBAN system. The proposed receiver antenna selection method takes advantage of the characteristic of BPPM (Binary Pulse Position Modulation). With the property of BPPM, this scheme calculates the approximate SNR of the received signal with non-coherent receiver.

  • PDF

Design and Comparison of Digital Predistorters for High Power Amplifiers (비선형 고전력 증폭기의 디지털 전치 보상기 설계 및 비교)

  • Lim, Sun-Min;Eun, Chang-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.4C
    • /
    • pp.403-413
    • /
    • 2009
  • We compare three predistortion methods to prevent signal distortion and spectral re-growth due to the high PAPR (peak-to-average ratio) of OFDM signal and the non-linearity of high-power amplifiers. The three predistortion methods are pth order inverse, indirect learning architecture and look up table. The pth order inverse and indirect learning architecture methods requires less memory and has a fast convergence because these methods use a polynomial model that has a small number of coefficients. Nevertheless the convergence is fast due to the small number of coefficients and the simple computation that excludes manipulation of complex numbers by separate compensation for the magnitude and phase. The look up table method is easy to implement due to simple computation but has the disadvantage that large memory is required. Computer simulation result reveals that indirect learning architecture shows the best performance though the gain is less than 1 dB at $BER\;=\;10^{-4}$ for 64-QAM. The three predistorters are adaptive to the amplifier aging and environmental changes, and can be selected to the requirements for implementation.

High-Performance and Low-Complexity Decoding of High-Weight LDPC Codes (높은 무게 LDPC 부호의 저복잡도 고성능 복호 알고리즘)

  • Cho, Jun-Ho;Sung, Won-Yong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.5C
    • /
    • pp.498-504
    • /
    • 2009
  • A high-performance low-complexity decoding algorithm for LDPC codes is proposed in this paper, which has the advantages of both bit-flipping (BF) algorithm and sum-product algorithm (SPA). The proposed soft bit-flipping algorithm requires only simple comparison and addition operations for computing the messages between bit and check nodes, and the amount of those operations is also small. By increasing the utilization ratio of the computed messages and by adopting nonuniform quantization, the signal-to-noise ratio (SNR) gap to the SPA is reduced to 0.4dB at the frame error rate of 10-4 with only 5-bit assignment for quantization. LDPC codes with high column or row weights, which are not suitable for the SPA decoding due to the complexity, can be practically implemented without much worsening the error performance.

Integrating GPS/INS/PL for Robust Positioning: The Challenging Issues

  • Wang, Jinling;Babu, Ravindra;Li, Di;Chan, Franics;Choi, Jin-Ho
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.127-132
    • /
    • 2006
  • The Global Positioning System (GPS), Inertial Navigation System (INS) and Pseudolite (PL) technologies all play very important roles in navigation systems. As an independent navigation system, GPS can provide high precision positioning results which are independent of time. However, the performance will become unreliable when the system experiences high dynamics, or when the receiver is exposed to jamming or RF interference. In comparison to GPS, though INS is autonomous and provides good short-term accuracy, its use as a standalone navigation system is limited due to the time-dependent growth of the inertial sensor errors. PLs are ground-based transmitters that can transmit GPS-like signals. They have some advantages in that their positions can be determined precisely, and the Signal-to-Noise Ratios (SNR) are relatively high. Because their combined performance, in principle, overcomes the shortcomings of the individual systems, the integration of GPS, INS and PL is increasingly receiving attention from researchers. Depending on the desired performance vs complexity, system integration can be carried out at different levels, namely loose, tight and ultra-tight coupling. Compared with loose and tight integration, although it is more complex in terms of system design, ultra-tight integration will be the basis of the next generation of reliable and robust navigation systems. Its main advantages include improved performance under exposure to high dynamics, and jamming and RF interference mitigation. This paper presents an overview of the ultra-tight integration developments and discusses some of the challenging issues.

  • PDF

Ranging Enhancement using Frequency Offset Compensation in High Rate UWB (고속 UWB에서 주파수 편이 보상을 사용한 거리추정 성능향상)

  • Nam, Yoon-Seok;Jang, Ik-Hyeon
    • The KIPS Transactions:PartC
    • /
    • v.16C no.2
    • /
    • pp.229-236
    • /
    • 2009
  • UWB signal with high resolution capability can be used to estimate ranging and positioning in wireless personal area networks. The clock frequency differences of nodes have serious affects on asynchronous ranging methods to estimate locations of mobile nodes. The specification of high rate UWB describes successive TWR method with the estimation of a relative clock frequency offset. In this paper, we complete the ranging equations using relative frequency offset and time information, and propose a method to estimate the exact frequency offsets. We evaluate the ranging algorithms with simulation. The results show that the performances of the algorithms using frequency offsets are very close without noise. But, at noise environment, the method of exact frequency offsets shows better performance than that of relative frequency offsets.

The Usefulness of LEUR Collimator for 1-Day Basal/Acetazolamide Brain Perfusion SPECT (1-Day Protocol을 사용하는 Brain Perfusion SPECT에서 LEUR 콜리메이터의 유용성)

  • Choi, Jin-Wook;Kim, Soo-Mee;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.94-100
    • /
    • 2011
  • Purpose: Basal/Acetazolamide-challenged brain perfusion SPECT is very useful to assess cerebral perfusion and vascular reserve. However, as there is a trade off between sensitivity and spatial resolution in the selection of collimator, the selection of optimal collimator is crucial. In this study, we examined three collimators to select optimal one for 1-day brain perfusion SPECT. Materials and Methods: Three collimators, low energy high resolution-parallel beam (LEHR-par), ultra resolution-fan beam (LEUR-fan) and super fine-fan beam (LESFR-fan), were tested for 1-day imaging using Triad XLT 9 (TRIONIX). The SPECT images of Hoffman 3D brain phantom filled with 99mTc of 170 MBq and a normal volunteer were acquired with a protocol of 50 kcts/frame and detector rotation of 3 degree. Filterd backprojection (FBP) reconstruction with Butterworth filter (cut off frequencies, 0.3 to 0.5) was performed. The quantitative and qualitative assessments for three collimators were performed. Results: The blind tests showed that LESFR-fan provided the best image quality for Hoffman brain phantom and the volunteer. However, images for all the collimator were evaluated as 'acceptable'. On the other hand, in order to meet the equivalent signal-to-noise ratio (SNR), total acquisition time or radioactivity dose for LESFR-fan must have been increased up to almost twice of that for LEUR-fan and LEHR-par. The volunteer test indicated that total acquisition time could be reduced approximately by 10 to 14 min in clinical practice using LEUR-fan and LEHR-par without significant loss on image quality, in comparison with LESFR-fan. Conclusion: Although LESFR-fan provides the best image quality, it requires significantly more acquisition time than LEUR-fan and LEHR-par to provide reasonable SNR. Since there is no significant clinical difference between three collimators, LEUR-fan and LEHR-par can be recommended as optimal collimators for 1-day brain perfusion imaging with respect to image quality and SNR.

  • PDF

Design of a High-speed Decision Feedback Equalizer using the Constant-Modulus Algorithm (CMA 알고리즘을 이용한 고속 DFE 등화기 설계)

  • Jeon, Yeong-Seop;;Kim, Gyeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.39 no.4
    • /
    • pp.173-179
    • /
    • 2002
  • This paper describes an equalizer using the DFE (Decision Feedback Equalizer) structure, CMA (Constant Modulus Algorithm) and LMS (Least Mean Square) algorithms. The DFE structure has better channel adaptive performance and lower BER than the transversal structure. The proposed equalizer can be used for 16/64 QAM modems. We employ high speed multipliers, square logics and many CSAs (Carry Save Adder) for high speed operations. We have developed floating-point models and fixed-point models using the COSSAP$\^$TM/ CAD tool and developed VHDL filter. The proposed equalizer shows low BER in multipath fading channel. We have performed models. From the simulation results, we employ a 12 tap feedback filter and a 8 tap feedforward logic synthesis using the SYNOPSYS$\^$TM/ CAD tool and the SAMSUNG 0.5$\mu\textrm{m}$ standard cell library (STD80) and verified function and timing simulations. The total number of gates is about 130,000.