• Title/Summary/Keyword: hemostatics

Search Result 15, Processing Time 0.018 seconds

Wound healing effect of regenerated oxidized cellulose versus fibrin sealant patch: An in vivo study

  • Yoon, Hyun Sik;Na, Young Cheon;Choi, Keum Ha;Huh, Woo Hoe;Kim, Ji Min
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.5
    • /
    • pp.289-296
    • /
    • 2019
  • Background: Topical hemostatic agents are used when ligation, electrocauterization, or other conventional hemostatic methods are impractical. Because a hemostatic agent is a foreign body, it can cause foreign body reactions, inflammation, and infections that can interfere with the wound healing process. Therefore, we should select hemostatic agents after considering their effects on wound healing. Here, we compared the effects of hemostatic agents on wound healing in a rectus abdominis muscle defect in rats. Methods: Twelve Sprague Dawley rats were subjected to creation of a $6{\times}6mm$ defect in the rectus abdominis muscle and divided into four groups: control group; group A, Tachosil fibrin sealant patch; group B, Surgicel Fibrillar oxidized regenerated cellulose; and group C, Surgicel Snow oxidized regenerated cellulose. For the histologic analysis, biopsies were performed on the 3rd, 7th, and 27th days. Results: The foreign body reaction was the weakest in group A and most significant in group C. The inflammatory cell infiltration was the weakest in group A and similar in groups B and C. Muscle regeneration differed among periods. The rats in group A were the most active initially, while those in group C showed prolonged activity. Conclusion: Tachosil and Surgicel administration increased inflammation via foreign body reactions, but the overall wound healing process was not significantly affected. The increased inflammation in the Surgicel groups was due to a low pH. We recommend using Tachosil, because it results in less intense foreign body reactions than Surgicel and faster wound healing due to the fibrin action.

Effect of an aluminum chloride hemostatic agent on the dentin shear bond strength of a universal adhesive

  • Sujin Kim;Yoorina Choi;Sujung Park
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.2
    • /
    • pp.14.1-14.11
    • /
    • 2023
  • Objectives: This study investigated the effect of an aluminum chloride hemostatic agent on the shear bond strength (SBS) of a universal adhesive to dentin. Materials and Methods: Eighty extracted human molars were trimmed at the occlusal dentin surfaces and divided mesiodistally. According to hemostatic agent application, specimens were randomly allocated into control (C) and hemostatic agent (Traxodent; H) groups. Each group was divided into 4 subgroups according to the adhesive system (n = 20): Scotchbond Multi-Purpose (SBER), Clearfil SE Bond (CLSE), All-Bond Universal etch-and-rinse mode (ALER), and All-Bond Universal self-etch mode (ALSE). SBS was measured for half of the specimens at 24 hours, and the other half were thermocycled in water baths (group T). Fracture surfaces were examined to determine the failure mode. The SBS was measured, and data were analyzed using 1-way analysis of variance, the Student's t-test, and the Tukey honestly significant difference test (p = 0.05). Results: No significant differences in SBS were found between groups C and H for any adhesive system at 24 hours. After thermocycling, a statistically significant difference was observed between CT+ALSE and HT+ALSE (p < 0.05). When All-Bond Universal was applied to hemostatic agent-contaminated dentin, the SBS of H+ALSE was significantly lower than that of H+ALER (p < 0.05). The SBER subgroups showed no significant differences in SBS regardless of treatment and thermocycling. Conclusions: When exposed dentin was contaminated by an aluminum chloride hemostatic agent before dentin adhesive treatment, application of All-Bond Universal in etch-and-rinse mode was superior to self-etch mode.

Difference in Bonding Strength of RMGIC according to Type of Hemostatic Agent in Primary Tooth (지혈제의 종류에 따른 레진 강화형 글라스아이오노머 시멘트 결합력의 차이)

  • Back, Seolah;Lee, Joonhaeng;Kim, Jongbin;Han, Miran;Kim, Jong Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.4
    • /
    • pp.460-466
    • /
    • 2021
  • The purpose of this study was to compare the effect of the hemostatic agent containing aluminum chloride with hemostatic agent containing ferric sulfate on the shear bond strength of resin-modified glass ionomer cement(RMGIC) to dentin in primary tooth. Twenty extracted non-carious human primary teeth were collected in this study. The specimens were cut to expose dentin and polished. The specimens were randomly seperated into 3 groups for treatment; group I: polyacrylic acid(PAA), RMGIC; group II: aluminum chloride, PAA, RMGIC; group III: ferric sulfate, PAA, RMGIC Ten specimens from each group were subjected to shear bond strength test. The mean shear bond strength of each group was as follows: 10.07 ± 1.83 MPa in Group I, 7.62 ± 0.78 MPA in group II, 5.23 ± 0.78 MPa in group III. There were significant differences among all groups(p < 0.001). In conclusion, both aluminum chloride hemostatic agent and ferric sulfate hemostatic agent decreased the shear bond strength of RMGIC to dentin. And ferric sulfate hemostatic agent decreased the shear bond strength of RMGIC more than the aluminium chloride hemostatic agent.

Effect of Aluminum Chloride Hemostatic Agent on Bonding Strength of RMGIC in Primary Tooth (염화알루미늄 지혈제가 유치와 레진강화형 글라스아이오노머 시멘트의 결합강도에 미치는 영향)

  • Woo, Seung-Hee;Shin, Jisun;Lee, Joonhaeng;Han, Miran;Kim, Jong Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.4
    • /
    • pp.397-404
    • /
    • 2021
  • The purpose of this study was to evaluate the effect of a hemostatic agent containing aluminum chloride on the shear bond strength of resin-modified glass ionomer cement (RMGIC) to the dentin of primary teeth. Thirty-six extracted non-carious human primary teeth were collected in this study. Dentin surfaces were cut and polished. The specimens were randomly divided into 4 groups; group I: RMGIC without conditioning; group II: polyacrylic acid (PAA), RMGIC; group III: aluminum chloride, RMGIC; group IV: aluminum chloride, PAA, RMGIC. All teeth were thermocycled between 5.0℃ and 55.0℃ for 5000 cycles. Fifteen specimens from each group were subjected to shear bond strength test and 3 specimens from each group were inspected using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy. The mean shear bond strength of each group was as follows: 4.04 ± 0.88 MPa in group I, 8.29 ± 1.40 MPa in group II, 1.39 ± 0.47 MPa in group III, 6.24 ± 2.76 MPa in group IV. There were significant differences among all groups (p < 0.001). SEM image of the dentinal tubules were partially exposed in group III and group IV. Fully exposed dentinal tubules were found in group II. In conclusion, aluminum chloride decreased the shear bond strength of RMGIC to dentin, regardless of PAA conditioning.

Comparative Analysis of Delivery Management in Various Medical Facilities (의료기관별 분만관리 양상의 비교 분석)

  • Park, Jung-Han;You, Young-Sook;Kim, Jang-Rak
    • Journal of Preventive Medicine and Public Health
    • /
    • v.22 no.4 s.28
    • /
    • pp.555-577
    • /
    • 1989
  • This study was conducted to compare the delivery management including laboratory tests, medication and surgical procedures for the delivery in various medical facilities. Two university hospitals, two general hospitals, three hospitals, two private obstetric clinics, and two midwifery clinics in a large city were selected as they permitted the investigators to abstract the required data from the medical and accounting records. The total number of deliveries occurred at these 11 facilities between 15 January and 15 February, 1989 was 789 among which 606(76.8%) were vaginal deliveries and 183 (23.3%) were C-sections. For the normal vaginal deliveries, CBC, Hb/Hct level, blood typing, VDRL, hepatitis B antigen and antibody, and urinalysis were routinely done except the private clinics and midwifery clinics which did not test for hepatitis B and Hb/Hct level at all. In one university hospital ultrasonography was performed in 71.4% of the mothers and in one general hospital liver function test was done in 76.7% of the mothers. For the C-section, chest X-ray, bleeding/clotting time and liver function test were routinely done in addition to the routine tests for the normal vaginal deliveries. Episiotomy was performed in 97.2% of the vaginal deliveries. The type and duration of fluid infused and antibiotics administered showed a wide variation among the medical facilities. In one university hospital antibiotics was not administered after C-section at all while in the general hospitals and hospitals one or two antibiotics were administered for one week on the average. In one private clinic one pint of whole blood was transfused routinely. A wide variation was observed among the medical facilities in the use of vitamin, hemostatics, oxytocics, antipyreptics, analgesics, anti-inflammatory agents. sedatives. digestives. stool softeners. antihistamines. and diuretics. Mean hospital day for the normal vaginal deliveries of primipara was 2.6 days with little variation except one hospital with 3.5 days. Mean hospital day for the C-section of primipara was 7.5 days and that of multipara was 7.6 days and it ranged between 6.5 days and 9.4 days. Average hospital fee for a normal vaginal delivery without the medical insurance coverage was 182,100 Won for the primipara and 167,300 Won for the multipara. In case of the primipara covered by the medical insurance a mother paid 82,400 Won and a multiparous mother paid 75,600 Won. Average hospital fee for a C-section without the medical insurance was 946,500 Won for the primipara and 753,800 Won for the multipara. In case of the primipara covered by the medical insurance a mother paid 256,200 Won and a multiparous mother paid 253,700 Won. Average hospital fee for a normal vaginal delivery in the university hospitals showed a remarkable difference, 268,000 Won vs 350,000 Won, as well as for the C-section. A wide variation in the laboratory tests performed for a normal vaginal delivery and a C-section as well as in the medication and hospital days brought about a big difference in the hospital fee and some hospitals were practicing the case payment system. Thus, standardization of the medical care to a certain level is warranted for the provision of adequate medical care for delivery.

  • PDF