• Title/Summary/Keyword: heat leakage

Search Result 341, Processing Time 0.025 seconds

Insulation Characteristics and Thermography Diagnosis of Porcelain Insulators for the Distribution Systems (배전용 자기재 현수애자의 절연특성과 열화상 진단)

  • Joung, Jong-Man;Kim, Dong-Myeong;Choi, Myung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.4
    • /
    • pp.267-271
    • /
    • 2011
  • The insulating characteristics and temperature rise behaviors of porcelain suspension insulators were investigated. The testing insulators had used in the distribution systems normally and were sampled. Firstly, leakage current was measured and its impedance was calculated. The leakage current of good insulators is 0.2 mA and its impedance is 66 $M{\Omega}$. The worse insulators have lower impedance and the insulators having below 15 $M{\Omega}$ take place flashover at the high frequency voltage flashover test. Secondly, the temperature rise characteristics were analyzed depending on leakage current and its impedance. Surface temperature of insulators was measured for 30 minutes and until its saturation after voltage was applied. The temperature rise of insulators having 15 $M{\Omega}$ is about $14.5^{\circ}C$ above the ambient temperature. Lastly, the heating behaviors of 3 insulators in a string was analyzed. Any insulator in the string does not generate heat so far as it has at least one sound insulator. On the other hand, all the insulators in the string are bad if the string have any heating insulator.

The Air Leakage Characteristics and Airtightness Performance of a Newly Built Apartment (신축 공동주택의 누기특성 및 기밀성능 분석에 관한 연구)

  • Lee, Yun Gyu;Shin, Cheol Woong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.11
    • /
    • pp.606-611
    • /
    • 2013
  • In responding to the recent framework convention on climate change, and the rise of the need for energy efficient buildings, such as Zero Energy Buildings (ZEB), domestic insulation standards and energy conservation regulations are being reinforced, to prevent heat loss. Accordingly, the Ministry of Land, Infrastructure and Transport have made amendments in Chapter 21 "Enforcement regulations for building facilities standards etc.", and Chapter 22 "Energy conservation standard", to reflect these changes. To effectively implement these regulations, it is required to propose air-tightness test methods, and establish air-tightness standards, based on the air leakage characteristics of domestic apartment housings. This research has been done primarily to collect basic technical data, to provide guidance for the establishment of domestic air-tightness standards for new apartment housing, through studying air-tightness test methods, field measurement on air-tightness of new apartment housings, and air leakage characteristics of major developed countries.

Study on IPT Characteristics of LSR / Nano Silica Composites for HVDC (HVDC용 LSR/Nano Silica Composites의 IPT특성 연구)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.61-68
    • /
    • 2019
  • Only the power is converted from AC to DC, in accordance with IEC 60587 based test method, in order to develop the LSR(Liquid Silicone Rubber) insulator material for HVDC, the experiment of Inclined Plate Tracking and Erosion Resistance was conducted. A contaminant (2.5 mS/cm: ammonium chloride) was applied at a rate of 0.3 ml/min and a voltage of ${\pm}3.5kV$, and was evaluated on the basis of 60 mA/2s. The samples were prepared by dispersing LSR/Nano silica_25wt% Composites in LSR. The erosion phenomena of surface discharge and tracking due to DC polarity and negative polarity were measured by image, leakage current maximum and thermal camera. The thermal imaging camera measured the surface temperature generated by the joule heat of the leakage current due to the drying discharge and the conductive current. After the measurement, the tracking and erosion mechanisms were evaluated for erosion weight, erosion depth and erosion length. Positive and negative polarity of LSR/Nano Silica_25wt% composite Tracking and erosion results show that positive polarity is more severe than negative polarity.

Investigation on helix type labyrinth seal to minimize leakage flow of cryogen for rotating superconducting machines

  • Yubin Kim;Kihwan Kim;Seungcheol Ryu;Hojun Cha;Seokho Kim
    • Progress in Superconductivity and Cryogenics
    • /
    • v.26 no.1
    • /
    • pp.25-30
    • /
    • 2024
  • High-temperature superconducting rotors offer advantages in terms of output-to-weight ratio and efficiency compared to conventional phase conduction motors or generators. The rotor can be cooled by conduction cooling, which attaches a cryocooler, and by refrigerant circulation, which uses circulating liquid or gas neon, helium and hydrogen. Recent work has focused on environmental issues and on high-temperature superconducting motors cooled with liquid hydrogen that can be combined with fuel cells. However, to ensure smooth supply and return of the cryogenic cooling fluid, a cryogenic rotational coupling between the rotating and stationary parts is necessary. Additionally, the development of a sealing structure to minimize fluid leakage applicable to the coupling is essential. This study describes the design and performance evaluation of a non-contact sealing method, specifically a labyrinth seal, which avoids power loss and heat load caused by friction in contact sealing structures. The seal design incorporates a spiral flow path to reduce leakage using centrifugal force, and computational fluid dynamics (CFD) simulations were conducted to analyze the flow path and rotational speed. A performance evaluation device was configured and employed to evaluate the designed seal. The results of this study will be used to develop a cryogenic rotational coupling with supply and return flow paths for cryogenic applications.

Effects of Postharvest Heat Treatment on Alleviation Chilling Injury and Improvement Storability of Oriental Melon (수확 후 고온처리가 참외의 저온장해 완화와 저장성 향상에 미치는 영향)

  • Kang Ho-Min;Park Kuen-Woo;Kim Il Sop
    • Journal of Bio-Environment Control
    • /
    • v.14 no.3
    • /
    • pp.137-143
    • /
    • 2005
  • Oriental melons hold at $38^{\circ}C$ for 48 hours before storage increased their soluble solid, titratable acidity, vitamin C contents and ${\alpha}$-tocopherol activity. These heat treated oriental melons maintained lower production of carbon dioxide, ethylene and acetaldehyde and loss of fresh weight than untreated them, called control, during $3^{\circ}C$ MA storage. After 39 days in storage, the last day of storage, visual quality and internal quality, such as firmness, soluble solid, titratable acidity, vitamin C and ${\alpha}$-tocopherol activity, showed higher in heat treated oriental melons. Especially, Ion leakage of flesh, index of chilling injury, increased remarkably in control, so that heat treatment had to alleviate chilling injury in oriental melon. Moreover, while Alternaria rot was shown in control plot after 25 days in $3^{\circ}C$ MA storage, oriental melons treated heat were not appeared any decomposition after 39 days in $3^{\circ}C$ MA storage. As storage life of oriental melon was calculated by regression equation between visual quality and days in storage, that was longer 8 days in heat treated than control. Consequently, heat treatment that was mild, $38^{\circ}C$ and long period, 48 hours, executed before storage, sterilized surface alleviated chilling injury and lengthened storage life in oriental melons.

A Study on Frost Protection Methods for Water Meter in Seoul Area (서울지역의 수도계량기 동파방지방안 연구)

  • Kim, H.I.;Ryu, T.H.;Park, T.J.;Oh, S.Y.;Choi, Y.J.
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.612-617
    • /
    • 2007
  • Water meter frost in winter is a nuisance to the water administration and citizen as well. It causes stop of water supply, possibility of accident due to leakage freezing, and additional official work to change frost water meters. This study was carried out to give some basic information of water meter frost condition, to verify the effect of frost protection devices such as lagging vinyl cover, electric heater, and meter pit using subterranean heat. Nearly half of the number of the water meter frost happens in old apartment house with outer corridor, and temperature of the meter box was measured in that kind of apartment house, comparing with atmosphere temperature. The capability of three kinds of lagging vinyl cover was investigated by measuring the inside temperature of the insulated box. Also the capability of existing meter pits and new meter pits using subterranean heat was compared by measuring the inside temperature of the pits. One of the result is that the inside temperature of meter pits using subterranean heat was higher than that of the existing ones, and deeper pit causes higher inside temperature in case of using subterranean heat.

  • PDF

Comparison on Safety Features among HTGR's Reactor Cavity Cooling Systems (RCCSs)

  • Kuniyoshi Takamatsu;Shumpei Funatani
    • Nuclear Engineering and Technology
    • /
    • v.56 no.3
    • /
    • pp.832-845
    • /
    • 2024
  • Reactor cavity cooling systems (RCCSs) comprising passive safety features use the atmosphere as a coolant, which cannot be lost. However, their drawback is that they are easily affected by atmospheric disturbances. To realize the commercial application of the two types of passive RCCSs, namely RCCSs based on atmospheric radiation and atmospheric natural circulation, their safety must be evaluated, that is, they must be able to remove heat from the reactor pressure vessel (RPV) surface at all times and under any condition other than under normal operating conditions. These include both expected and unexpected natural phenomena and accidents. Moreover, they must be able to eliminate the heat leakage emitted from the RPV surface during normal operation. However, utilizing all of the heat emitted from the RPV surface increases the degree of waste heat utilization. This study aims to understand the characteristics and degree of passive safety features for heat removal by comparing RCCSs based on atmospheric radiation and atmospheric natural circulation under the same conditions. It was concluded that the proposed RCCS based on atmospheric radiation has an advantage in that the temperature of the RPV could be stably maintained against disturbances in the ambient air.

A Study on Life Cycle Extension of T-50 Aircraft Hydraulic Control Valve (T-50 항공기 유압조절 밸브 수명연장 방안)

  • Nam, Yongseo;Kim, Taehwa;Baek, Seungji;Kim, Seunghyu;Song, Seokbon
    • Journal of Aerospace System Engineering
    • /
    • v.4 no.2
    • /
    • pp.16-20
    • /
    • 2010
  • In General, the hydraulic system of T-50 Advanced Trainer is applied to flight control system, wheel & Brake system and fuel system for aircraft operation. The hydraulic system is operation with pressure of 3000psi. and many mechanical parts which is operated by hydraulic system has been stressed in incomplete environment same as heat and friction. for example, Oil leakage had occurred in the shutoff valve of FFP used in a certain period of time. After study, The crack progressed by fatigue due to the irregular hydraulic pressure and vibration has been identified as the reason of oil leakage. This paper presents life cycle extension plans of FFP shutoff valve by configuration improvements of shutoff valve and FFP hydraulic motor.

  • PDF

A Study of Aging Characteristic of EPDM by High-temperature Treatment (고온 열처리에 의한 EPDM의 열화 특성에 대한 연구)

  • Choi, N.H.;Han, S.I.;Han, S.O.;Yoon, J.Y.;Park, K.S.;Kim, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1465-1468
    • /
    • 1997
  • In this study we investigated the aging characteristic such as leakage current, dielectric loss, contact angle, of EPDM for outdoor use by thermal treatment. And also observed the color change of surface, changing of chemical ingredient of the marterials by optical microscope. SEMI, FTIR and EDX at the section and surface. The test result show that leakage current is increased with thermal aging time. contact angle and dielectric loss is slightly decreased. Moreover, micro-void or crack in bulk is severely increased with aging time. However, the result affect to the tan $\delta$ at bulk of EPDM. It seems that carrier sources are removed by degassing with heat treatment.

  • PDF

The Change of Electrical Properties on Silicone Rubber Contained ATH under Cyclic Aging(I) (ATH를 첨가한 실리콘고무의 반복열화에 따른 전기적 특성변화(I))

  • Oh, Tae-Seung;Lee, Chung;Kim, Ki-Yup;Park, Soo-Gil;Ryu, Boo-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.258-261
    • /
    • 2001
  • In this paper, aging characteristics of silicone rubber used for outdoor insulation have been investigated with regards to salt fog condition and heat aging effect. We look over the change of properties of silicone rubber in salt fog chamber with average leakage current monitoring for observing the transformation of surface degradation properties of silicone rubber with different ATH(alumina trihydrate, $Al_2O_3{\cdot}3H_2O$) filler contents. Surface resistivity, SEM(Scanning Electro Microscope) were measured.

  • PDF