• Title/Summary/Keyword: g-factor

Search Result 5,031, Processing Time 0.034 seconds

An Analytical Study on Ductility of Reinforced Concrete Columns under Tension Controlled Region (인장지배영역에서의 철근콘크리드 기둥의 연성에 관한 해석적 연구)

  • 손혁수;김준범;이재훈
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.527-532
    • /
    • 1997
  • Design strength of structural members could be determined by applying a strength reduction factor to nominal strength. At the beginning point of the transition region for the strength reduction factor, P=0.1$\sigma$$_{ck}A_g$, only sectional area and concrete strength are adopted as the variables of P=0.1$\sigma$$_{ck}A_g$. Therefore, P=0.1$\sigma$$_{ck}A_g$ is the empirically adopted which does not consider steel ratio, steel yielding stress, and steel arrangement. So, this research was perpormed the computer program for the analysis of axial force-moment-curvature relationship of reinforced concrete columns by sectional behaviour nonlinear analysis using a concrete compressive stress-strain curve, in order to investigate the ductility of reinforced concrete columns. As a result, ductility indicies of axial force, P=0.1$\sigma$$_{ck}A_g$, represented the lack of consistency of the indicies value for the various sections.

  • PDF

A study on the power factor improvement of Wind Turbine Generation System at Haeng-Won in Jeju (제주 행원 풍력 발전 시스템의 역률 개선에 관한 연구)

  • Park S.G.;Kim J.W.;Kang G.B.;Kim E.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.375-378
    • /
    • 2003
  • This paper presents a study on the power factor improvement of the Wind turbine Generation System(WTGS) at Haeng-won wind farm in Jeju Island. Vestas WTGS named V47 as a model system is selected in this paper, and has 660 kW Power ratings. In this system, power factor correction is controlled by the conventional method with power condenor bank. So, model system at Haeng-won wind farm has very low power factor in the area of low wind speed, which is from 4 m/s to 6 m/s. This is caused by the power factor correction using power condenser bank To improve the power factor in the area of low wind speed, we used the static var compensator(SVC) using current controlled PWM power converter by IGBT switching device. finally, to verify the profosed method, the results of computer simulation using Psim program are presented to support the discussion.

  • PDF

Characteristics of Metallic and Ionic Elements Concentration in PM10 at Guducsan in Busan (부산 구덕산 미세먼지의 금속성분 및 이온성분 농도 특성)

  • Jeon, Byung-Il
    • Journal of Environmental Science International
    • /
    • v.25 no.5
    • /
    • pp.715-726
    • /
    • 2016
  • This study investigates the characteristics of metallic and ionic elements concentration, concentration according to transport path, and factor analysis in $PM_{10}$ at Guducsan in Busan in the springtime of 2015. $PM_{10}$ concentration in Guducsan and Gwaebeopdong were $59.5{\pm}9.04{\mu}g/m^3$ and $87.5{\pm}20.2{\mu}g/m^3$, respectively. Contribution rate of water-soluble ions and secondary ion in $PM_{10}$ concentration in Guducsan were 37.0% and 27.8% respectively. [$NO_3{^-}/SO{_4}^{2-}$] ratio and contribution rate of sea salt of $PM_{10}$ in Guducsan and Gwaebeopdong were 0.91 and 1.12, 7.0% and 5.3%, respectively. The results of the backward trajectory analysis indicates that $PM_{10}$ concentration, total inorganic water-soluble ions and total secondary ions were high when the air parcels moved from Sandong region in China than non-Sandong and northen China to Busan area. The results of the factor analysis at Guducsan indicates that factor 1 was anthropogenic source effects such as automobile emissions and industrial combustion processes, factor 2 was marine sources such as sea salts from sea, and factor 3 was soil component sources.

A characterization of crossed products without cohomology

  • Hong, Jeong-Hee
    • Journal of the Korean Mathematical Society
    • /
    • v.32 no.2
    • /
    • pp.183-193
    • /
    • 1995
  • Let N be a $II_1$ factor and G be a finite group acting outerly on N. Then the crossed product algebra $M = N \rtimes G$ is also a $II_1$ factor and $N' \cap M = CI$, i.e. N is irreducible in M. Moreover, N is regular in M, in other words, M is generated by the normalizer $N_M (N)$.

  • PDF

Design of Magnetically Levitation Electromagnet Conveying Non-contact Steel Plate (비접촉 철판운송용 자기부상 전자석의 설계)

  • Cho, G.B.;Baek, H.L.;Oh, G.K.;Kim, Y.D.;Kim, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.107-109
    • /
    • 1995
  • This paper considers backing structure of non-contact steel plate using magnectically levitation and aspect-quality factor is defined by estimation of electromagnet-aspect attraction steel plate. Characteristics of attraction power is studied in cylindrical electromagnet, U-type electromagnet, E-type electromagnet by aspect-quality factor. Designing and manufacturing electromagnet attraction steel plate, propriety of experimental results is confirmed.

  • PDF

Comparative studies of various transfection processes for the optimal luminescence signal analysis (최적의 luminescence 신호 분석을 위한 유전자 전달 방법의 비교연구)

  • Park, Seohyun;Lee, Sunghou
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.640-647
    • /
    • 2016
  • By minimizing fluorescence interference phenomena, aequorin-based luminescence technology can provide a relatively sensitive detection platform with integration of $G{\alpha}16$ protein in order to track internal calcium mobilization by G protein-coupled receptors (GPCR). In this type of cell-based functional assay format, it is essential to optimize the transfection process of a receptor and $G{\alpha}16$ protein. For this study, corticotropin releasing factor receptor subtype 2(CRF2) was set as a model system to generate three stable cells with CRF2 and $G{\alpha}16$ in addition to transiently transfected cells under three different conditions. Agonist (sauvagine) and antagonist (K41498) responses in those cells were analyzed to develop the optimum transfection process. As a result, the effective signal ratio in the dose response experiments of sauvagine and K41498 were at least 10-fold higher (z'=0.77) in CRF2-$G{\alpha}16$ stable cells. For the transient transfection cells, stable expression of $G{\alpha}16$ prior to the CRF2 represented a two-fold higher signal (z'=0.84) than the other cases of transient transfection. In conclusion, for the utilization of transient transfection processes to develop a cell-based GPCR functional assay system, it is suggested to introduce various target receptors after stable expression of $G{\alpha}16$ protein.

The State of Marine Pollution in the Waters adjacent to Shipyards in Korea - 2. Assessment of the Pollution of Heavy Metals in Seawater around Major Shipyards in Summer 2010 (국내 조선소 주변해역의 해양오염 현황 - 2. 2010년 하계 대형조선소 주변 해수의 중금속오염 평가)

  • Kim, Kwang-Soo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.1
    • /
    • pp.9-17
    • /
    • 2015
  • In order to elucidate the current state of marine pollution of heavy metals around major shipyards in Korea, seawater samples were collected at eleven sampling stations and four control stations around 4 major shipyards located in the southeastern coast of Korea in summer 2010, and 6 kinds of metals such as copper(Cu), zinc(Zn), iron(Fe), cadmium(Cd), lead(Pb) and mercury(Hg) in seawater samples were analyzed. The analyses of heavy metals in seawater showed that the mean Cu concentrations in seawater around 4 major shipyards were in the range of $0.817{\sim}1.638{\mu}g/L$ which were lower than Korean environmental standards of $20{\mu}g/L$ for the protection of human health(PHH) and of $3{\mu}g/L$ for short-term protection of marine ecosystem(SPME) but higher than Cu concentration at control station by a factor of up to 2.75. The mean Zn concentrations were in the range of $0.228{\sim}0.567{\mu}g/L$ which were lower than Korean environmental standards of $100{\mu}g/L$ for PHH and $34{\mu}g/L$ for SPME but higher than Zn concentration at control station by a factor of up to 5.91. The mean Fe concentrations were in the range of $3.332{\sim}7.410{\mu}g/L$ which were higher than Fe concentration at control station by a factor of up to 6.75. The mean Cd concentrations were in the range of $0.013{\sim}0.028{\mu}g/L$ which were lower than Korean environmental standards of $10{\mu}g/L$ for PHH and $19{\mu}g/L$ for SPME but higher than Cd concentration at control station by a factor of up to 2.33. The mean Pb concentrations were in the range of $0.007{\sim}0.126{\mu}g/L$ which were lower than Korean environmental standards of $50{\mu}g/L$ for PHH and $7.6{\mu}g/L$ for SPME. The mean Hg concentrations were in the range of $0.002{\sim}0.004{\mu}g/L$ which were lower than Korean environmental standards of $0.5{\mu}g/L$ for PHH and $1.8{\mu}g/L$ for SPME. Although the concentrations of metals such as Cu, Zn and Fe which were used in shipbuilding works were lower than Korean environmental standards for PHH and SPME, the fact that the concentrations of Cu, Zn and Fe at sampling stations around major shipyards were higher than those at control stations implies that the works in shipyards had some effects on marine water quality around shipyards. Therefore, marine environment management such as the prevention and control of the discharge of various pollutants from shipyards is required on national level.

Factor G for Pipelines with Equally Spaced Multiple Outlets and Outflow (관수로에서 유출수에 따른 마찰계수 인자 G)

  • Anwar Arif A.
    • KCID journal
    • /
    • v.6 no.1
    • /
    • pp.81-87
    • /
    • 1999
  • 등간격으로 된 여러 개의 유출구와 말단의 배출이 있는 관수로에서 G 인자를 유도하였다. G인자는 관수로의 유출구 수에 따라 사용되는 마찰공식의 함수이며, 관의 입구에서부터 첫 번째 유출구까지의 거리가 유출구 사이의 간격과 같을 때 직접 수두손실의 계산에 사용될 수 있다. 그러나 관수로 하류 말단부에 배출량이 없을 때에는 G 인자는 잘 알려진 Christiansen의 F인자가 되며, G 인자는 여러 개의 유출구를 가진 관수로의 구간별 설계를 가능하게 한다

  • PDF