• 제목/요약/키워드: fractures

검색결과 2,684건 처리시간 0.03초

In vivo 3D Kinematics of Axis of Rotation in Malunited Monteggia Fracture Dislocation

  • Kim, Eugene;Park, Se-Jin;Jeong, Haw-Jae;Ahn, Jin Whan;Shin, Hun-Kyu;Park, Jai Hyung;Lee, Mi Yeon;Tsuyoshi, Murase;Sumika, Ikemototo;Kazuomi, Sugamoto;Choi, Young-Min
    • Clinics in Shoulder and Elbow
    • /
    • 제17권1호
    • /
    • pp.25-30
    • /
    • 2014
  • Background: Normal elbow joint kinematics has been widely studied in cadaver, whilst in vivo study, especially of the forearm, is rare. Our study analyses, in vivo, the kinematics of normal forearm and of malunited forearm using a three-dimensional computerized simulation system. Methods: We examined 8 patients with malunited Monteggia fracture and 4 controls with normal elbow joint. The ulna and radius were reconstructed from CT data placing the forearm in three different positions; full pronation, neutral, and full supination using computer bone models. We analyzed the axis of rotation 3-dimentionally based on the axes during forearm rotation from full pronation to full supination. Results: Axis of rotation of normal forearm was pitch line, with a mean range of 2 mm, from full pronation to full supination, connecting the radial head center proximally and ulnar fovea distally. In normal forearm, the mean range was 1.32 mm at the proximal radioulnar joint and 1.51 mm at the distal radioulnar joint. However in Monteggia fracture patients, this range changed to 7.65 mm at proximal and 4.99 mm at distal radoulnar joint. Conclusions: During forearm rotation, the axis of rotation was constant in normal elbow joint but unstable in malunited Monteggia fracture patients as seen with radial head instability. Therefore, consideration should be given not only to correcting deformity but also to restoring AOR by 3D kinematics analysis before surgical treatment of such fractures.

신부전환자의 신장이식 전후 골밀도변화 분석 (Analysis change in Bone Mineral Density before and after Kidney Transplant in Renal Failure Patient)

  • 박형후;옥치상;박영인;이진수;김창수
    • 한국콘텐츠학회논문지
    • /
    • 제12권9호
    • /
    • pp.250-256
    • /
    • 2012
  • 골밀도 감소에 의해서 발생되는 골감소증, 골다공증 등은 폐경 후 여성에게 유병률이 높은 질환이며, 골다공증 골절에 따른 사회적 의료비 상승으로 의학적 관심이 급증하고 있다. 신부전환자는 체내에 비타민D 합성 능력이 저하되어 칼슘 흡수가 감소하여 뼈의 섬유화가 발생되고, 골밀도가 감소하는 현상이 나타난다. 따라서 신부전환자는 신장 기능 장애로 그치지 않고, 골다공증과 같은 골밀도 감소에 따른 합병증에 노출되어 있다. 본 연구에서는 치료 중에 있는 신부전환자들의 골밀도 변화를 관찰하였고, 신장이식 전후에서 발견되는 골밀도 변화를 분석하였다. 조사대상은 부산 B종합병원 신장내과 내원환자 중 신부전환자 214명을 신장이식의 유무에 따라 골밀도의 변화를 세대별, 성별로 나누어 분석했다. 분석결과 신장이식 환자군에서는 골밀도가 유지되거나 개선되었지만, 비신장이식 환자군에서는 골밀도가 꾸준히 나빠지는 결과를 보였다. 신부전환자는 신장이식을 받는 것이 최선의 치료책으로 사료되며, 신장이식을 통해서 골밀도의 개선이 가능함을 확인하였다. 이는 추가적으로 예상되는 합병증을 예방하기 위한 자료로도 활용할 수 있다.

대구치에서 회전식 NiTi file의 수명과 파절양상 (LIFETIME AND FRACTURE PATTERNS OF NITI ROTARY FILES IN MOLARS)

  • 김진우;안병두;박세희;신혜진;조경모
    • Restorative Dentistry and Endodontics
    • /
    • 제30권3호
    • /
    • pp.184-192
    • /
    • 2005
  • 회전식 NiTi file은쉽게 파절되는 단점이 있으나 이에 대한 연구는 아직 부족하다. 본 연구에서는 회전식 NiTi file을 이용해 실제 치아에서 근관을 형성하고, 이 때 발생하는 파절 및 변형을 연구, 분석하였다. 상악 대구치의 근심협측 치근 (n = 150)과 하악 대구치의 근심치근 (n = 150)을 실험대상으로 하여 Profile, ProTaper 및 K3로 각각 근관형성 하였다. 각 file은 파절되거나 변형이 생길 때까지 계속하여 사용한 다음 그 사용횟수를 기록하였다. 파절의 양상을 관찰하기 위해 방사선 및 주사현미경 사진을 촬영하였다. 1 세 군간의 유의할만한 사용횟수의 차이는 없었다. 2. Flaring file 간의 비교에서는 K3의 사용횟수가 통계적으로 유의성 있게 적었으며 (p < 0.05), shaping file 간에는 유의할만한 차이가 없었다. 3, 회전식 NiTi file의 파절은 근관의 최대 만곡부에서 발생하였다. 4. 주사전자현미경으로 파절면을 관찰한 결과 연성파괴의 전형적인 양상인 얕은 딤플이 관찰되었다. 일반적으로 회전식 NiTi file의 평균 사용횟수는 제조회사의 사용지침보다는 길었으며, NiTi file의 수명에 대한 새로운 사용지침을 만들기 위한 부가적인 연구가 있어야 되리라 사료된다.

임플랜트 지지 보철물에서 고정체의 식립위치와 각도에 따른 삼차원 유한요소법적 응력분석에 관한 연구 (THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS ACCORDING TO THE DIFFERENT FIXTURE LOCATIONS AND ANGULATIONS)

  • 박원희;이영수
    • 대한치과보철학회지
    • /
    • 제43권1호
    • /
    • pp.61-77
    • /
    • 2005
  • Statement of problem. The implant prosthesis has been utilized in various clinical cases thanks to its increase in scientific effective application. The relevant implant therapy should have the high success rate in osseointegration, and the implant prosthesis should last for a long period of time without failure. Resorption of the peri-implant alveolar bone is the most frequent and serious problem in implant prosthesis. Excessive concentration of stress from the occlusal force and biopressure around the implant has been known to be the main cause of the bone destruction. Therefore, to decide the location and angulation of the implant is one of the major considering factors for the stress around the implant fixture to be dispersed in the limit of bio-capacity of load support for the successful and long-lasting clinical result. Yet, the detailed mechanism of this phenomenon is not well understood. To some extent, this is related to the paucity of basic science research. Purpose. The purpose of this study is to perform the stress analysis of the implant prosthesis in the partially edentulous mandible according to the different nature locations and angulations using three dimensional finite element method. Material and methods, Three 3.75mm standard implants were placed in the area of first and second bicuspids, and first molar in the mandible Thereafter, implant prostheses were fabricated using UCLA abutments. Five experimental groups were designed as follows : 1) straight placement of three implants, 2) 5$^{\circ}$ buccal and lingual angulation of straightly aligned three implants, 3) 10$^{\circ}$ buccal and lingual angulation of straightly aligned three implants. 4) lingual offset placement of three implants, and 5) buccal offset placement of three implants. Average occlusal force with a variation of perpendicular and 30$^{\circ}$ angulation was applied on the buccal cusp of each implant prosthesis, followed by the measurement of alteration and amount of stress on each configurational implant part and peri-implant bio-structures. The results of this study are extracted from the comparison between the distribution of Von mises stress and the maximum Von mises stress using three dimensional finite element stress analysis for each experimental group. Conclusion. The conclusions were as follows : 1. Providing angulations of the fixture did not help in stress dispersion in the restoration of partially edentulous mandible. 2. It is beneficial to place the fixture in a straight vertical direction, since bio-pressure in the peri-implant bone increases when the fixture is implanted in an angle. 3. It is important to select an appropriate prosthodontic material that prevents fractures, since the bio-pressure is concentrated on the prosthodontic structures when the fixture is implanted in an angle. 4. Offset placement of the fixtures is effective in stress dispersion in the restoration of partially edentulous mandible.

APPLICATION OF FINITE ELEMENT ANALYSIS TO EVALUATE IMPLANT FRACTURES

  • Kim Yang-Soo;Kim Chang-Whe;Lim Young-Jun;Kim Myung-Joo
    • 대한치과보철학회지
    • /
    • 제44권3호
    • /
    • pp.295-313
    • /
    • 2006
  • Statement of problem. Higher fracture rates were reported for Branemark implants placed in the maxilla and for 3.75 mm diameter implants installed in the posterior region. Purpose. The purpose of this study was to investigate the fracture of a fixture by finite element analysis and to compare different diameter of fixtures according to the level of alveolar bone resorption. Material and Methods. The single implant and prosthesis was modeled in accordance with the geometric designs for the 3i implant systems. Models were processed by the software programs HyperMesh and ANSA. Three-dimensional finite element models were developed for; (1) a regular titanium implant 3.75 mm in diameter and 13 mm in length (2) a regular titanium implant 4.0 mm in diameter and 13 mm in length (3) a wide titanium implant 5.0 mm in diameter and 13 mm in length each with a cementation type abutment and titanium alloy screw. The abutment screws were subjected to a tightening torque of 30 Ncm. The amount of preload was hypothesized as 650 N, and round and flat type prostheses were 12 mm in diameter, 9 mm in height were loaded to 600 N. Four loading offset points (0, 2, 4, and 6 mm from the center of the implants) were evaluated. To evaluate fixture fracture by alveolar bone resorption, we investigated the stress distribution of the fixtures according to different alveola. bone loss levels (0, 1.5, 3.5, and 5.0 mm of alveolar bone loss). Using these 12 models (four degrees of bone loss and three implant diameters), the effects of load-ing offset, the effect of alveolar bone resorption and the size of fixtures were evaluated. The PAM-CRASH 2G simulation software was used for analysis of stress. The PAM-VIEW and HyperView programs were used for post processing. Results. The results from our experiment are as follows: 1. Preload maintains implant-abutment joint stability within a limited offset point against occlusal force. 2. Von Mises stress of the implant, abutment screw, abutment, and bone was decreased with in-creasing of the implant diameter. 3. With severe advancing of alveolar bone resorption, fracture of the 3.75 and the 4.0 mm diameter implant was possible. 4. With increasing of bending stress by loading offset, fracture of the abutment screw was possible.

나사 시멘트 유지형 임플란트 보철물의 잔여 전부하 및 시멘트 파손에 대한 임상평가 (Clinical evaluation of retained preload and cement washout in screw- and cement-retained implant prosthesis)

  • 정재헌;손미경;김석규
    • 대한치과보철학회지
    • /
    • 제53권4호
    • /
    • pp.301-309
    • /
    • 2015
  • 목적: 이 연구의 목적은 지대주 나사 잔여 전부하 비율과 시멘트 파손유무 평가를 통해 나사 시멘트 유지형 임플란트 보철물(screw- and cement-retained implant prosthesis: SCP)의 임상적 수행 능력을 알아보는 것이다. 재료 및 방법: 구치부 부분 무치악 환자들을 대상으로 임플란트가 식립되었으며 3 - 6개월의 치유기간 후 SCP임플란트 보철물이 장착되었다. 추적관찰을 통해 임플란트의 생존율이 평가되고 보철물 성공률도 평가되었다. SCP 보철물의 나사 잔여 전부하 비율 및 시멘트 파손 비율이 측정되었다. 결과: 20명의 환자로부터 21개의 SCP보철물(43개의 임플란트)이 최대 64개월까지 관찰되었다. 관찰기간(평균 34개월) 동안 골융합에 실패한 임플란트는 하나도 없었다. 지대주, 나사, 도재 혹은 보철물 프레임 파절이나 나사 풀림 등은 없었으므로 보철물 성공율은 100%였다. SCP 보철물의 나사 잔여 전부하 비율은 97.61% (${\pm}16.29$), 그리고 시멘트 파손비율은 9.5%이었다. 결론: 본 실험의 한계 내에서, 나사 풀림과 시멘트 파손이란 관점에서 SCP 디자인의 임플란트 보철물은 양호한 단기 임상 결과를 보였다.

Fracture resistance of endodontically treated maxillary premolars restored by silorane-based composite with or without fiber or nano-ionomer

  • Shafiei, Fereshteh;Tavangar, Maryam Sadat;Ghahramani, Yasamin;Fattah, Zahra
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권3호
    • /
    • pp.200-206
    • /
    • 2014
  • PURPOSE. This in vitro study investigated the fracture resistance of endodontically treated premolars restored using silorane-or methacrylate-based composite along with or without fiber or nano-ionomer base. MATERIALS AND METHODS. Ninety-six intact maxillary premolars were randomly divided into eight groups (n = 12). G1 (negative control) was the intact teeth. In Groups 2-8, root canal treatment with mesio-occlusodistal preparation was performed. G2 (positive control) was kept unrestored. The other groups were restored using composite resin as follows: G3, methacrylate-based composite (Z250); G4, methacrylate composite (Z250) with polyethylene fiber; G5 and G6, silorane-based composite (Filtek P90) without and with the fiber, respectively; G7 and G8, methacrylate-and silorane-based composite with nano-ionomer base, respectively. After aging period and thermocycling for 1000 cycles, fracture strength was tested and fracture patterns were inspected. The results were analyzed using ANOVA and Tukey HSD tests (${\alpha}$=0.05). RESULTS. Mean fracture resistance for the eight groups (in Newton) were G1: $1200{\pm}169^a$, G2: $360{\pm}93^b$, G3: $632{\pm}196^c$, G4: $692{\pm}195^c$, G5: $917{\pm}159^d$, G6: $1013{\pm}125^{ad}$, G7: $959{\pm}148^d$, G8: $947{\pm}105^d$ (different superscript letters revealed significant difference among groups). Most of the fractures in all the groups were restorable, except Group 3. CONCLUSION. Silorane-based composite revealed significantly higher strength of the restored premolars compared to that of methacrylate one. Fiber insertion demonstrated no additional effect on the strength of both composite restorations; however, it increased the prevalence of restorable fracture of methacrylate-based composite restored teeth. Using nano-ionomer base under methacrylate-based composite had a positive effect on fracture resistance and pattern. Only fiber-reinforced silorane composite restoration resulted in a strength similar to that of the intact teeth.

의도적으로 남겨진 유치근 파절편의 예후 (THE PROGNOSIS OF INTENTIONALLY RETAINED ROOT FRAGMENT OF PRIMARY TEETH)

  • 이숙희;김신;정태성
    • 대한소아치과학회지
    • /
    • 제34권1호
    • /
    • pp.156-161
    • /
    • 2007
  • 소아치과 임상에서는 외상성 손상에 의하거나 발치 도중 우발적으로 유치의 치근이 파절되는 경우가 종종 있다. 이런 경우 임상의들은 치근 파절편을 발치할지, 남겨둘지에 대해 간혹 고민하게 된다. 이같은 상황에서 잔근이나 파절편의 발치 시도가 계승치 배를 손상시킬 우려가 있을 경우에는 일반적으로 치근 파절편을 남겨두는 것이 추천되고 있다. 본 연구는 유치 잔근이나 파절편을 술자 의도적으로 잔존시킨 경우, 계승치의 맹출경로에 장애를 가하지 않고 소멸될 것인지의 예후를 확인해 볼 목적으로 잔근이나 치근 파절편을 의도적으로 남긴 3세 8개월${\sim}6$세 1개월 어린이 6명을 대상으로 $7{\sim}37$개월 동안 $2{\sim}3$개월 주기의 내원을 통하여 임상검사와 방사선검사를 시행하고 예후를 장기 관찰하였다. 관찰 결과, 5 증례에서 치근측 파절편은 생리적인 흡수과정을 통하여 크기가 축소되거나 소멸되었고, 1 증례에서는 계승치와 함께 밀려 출은하였으며 계승치의 맹출을 현저하게 지장을 초래한 경우는 나타나지 않았다. 본 관찰을 통하여 치조골 내에 남은 유치근 파절편이 계승치배에 근접한 경우, 이를 무리하게 발치하려 시도하기보다는 치배의 손상 가능성을 고려하여 잔존시키고 주기적인 검진을 통해 흡수 여부를 판단하며 예후 관리를 하는 방법의 타당성을 확인할 수 있었다.

  • PDF

원인을 알 수 없는 폐출혈을 동반한 지방색전 증후군 1예 (Fat Embolism Syndrome with Pulmonary Hemorrhage of Unknown Origin)

  • 정혜철;정기환;김병규;김경규;이상엽;박상면;이신형;신철;조재연;심재정;인광호;김한겸;유세화;강경호
    • Tuberculosis and Respiratory Diseases
    • /
    • 제48권3호
    • /
    • pp.383-387
    • /
    • 2000
  • 지방색전증은 주로 근 골격계 외상 후 발생하는 호흡기계, 신경계 및 피부 출혈성 반점을 특징으로 하는 질환으로 정확한 병인기전은 잘 모르는 상태이나 대개는 위험요소를 가지고 있는 경우에 발생하며 진단방법으로 조직 검사 외에 폐포세척술이나 폐동맥카테터를 이용한 지방체의 존재 증명법 등이 연구되고 있다. 치료는 대부분 보존적 치료가 행해지고 있다. 연자들은 특별한 위험요소 없이 건강하게 지내던 중년의 성인여성에서 발생한 폐출혈을 동반한 지방색전증 1예를 경험하였기에 문헌 고찰과 함께 보고하는 바이다.

  • PDF

AlN 세라믹스와 금속간 계면접합에 관한 연구 : I. AlN/Cu 및 AlN/W 활성금속브레이징 접합체의 잔류응력 해석 (A Study on the Interfacial Bonding in AlN Ceramics/Metals Joints: I. Residual Stress Analysis of AlN/Cu and AlN/W Joints Produced by Active-Metal Brazing)

  • 박성계;이승해;김지순;유희;염영진
    • 한국재료학회지
    • /
    • 제9권10호
    • /
    • pp.962-969
    • /
    • 1999
  • Ag-Cu-Ti 삽입금속을 이용하여 제조된 AlN/Cu와 AlN/W 활성금속브레이징 접합체의 잔류응력을 유한요소법으로 탄성 및 탄소성 해석을 행하여 그 결과를 접합강도 측정 결과와 파단 거동 관찰 결과와 비교, 분석하였다. 최대 잔류 주응력의 크기는 AlN/W 접합체보다 모재간 열팽창계수 차이가 큰 AlN/Cu 접합체에서 더 크게 나타났으며, 접합계면에 인접한 AlN 세라믹스 자유표면에 인장 성분의 응력집중이 확인되었다. 모재와 삽입금속의 탄소성 변형을 모두 고려할 경우, AlN/Cu 접합체의 경우 연질의 삽입금속에 의해 최대 잔류 주응력이 감소하여 소성변형에 의한 응력완화 효과가 있음을 확인하였으나, 100$\mu\textrm{m}$ 이상으로 삽입금속 두께를 증가시키더라도 잔류 주응력의 크기는 더 이상 크게 감소하지 않았다. 측정된 최대 접합강도는 AlN/Cu와 AlN/W 접합체에서 각각 52 MPa와 108 MPa이었으며, 파단 형태는 AlN/Cu 접합체는 AlN 자유표면으로부터 AlN 내부로 큰 각도를 이루면 진행되는 돔형의 파단이, AlN/W 접합체에서는 접합계면의 삽입금속층을 따라 AlN 측에서 파단이 일어나는 형태를 보였다.

  • PDF