References
- Goodacre CJ, Kan JYK, Rungcharassaeng K. Clinical complication of osseointegrated implants. J Prosthet Dent 1999;81:537-552 https://doi.org/10.1016/S0022-3913(99)70208-8
- Rangert B, Krogh PHJ, Langer B, Van Roekel NB. Bending overload and implant fractures: A retrospective clinical analysis. Int J Oral Maxillofac Implants 1995;10:326-334
- Eckert SE, Meraw SJ, Cal E. Analysis of incidence and associated factors with fractured implants: A retrospective study. Int J Oral Maxillofac Implants 2000;15:662-667
- Naert I, Quirynen M, van Steenberghe D, Darius P. A six-year prosthodontic study of 509 consecutively inserted implants for the treatment of partial edentulism. J Prosthet Dent 1992;67:236-245 https://doi.org/10.1016/0022-3913(92)90461-I
- Quirynen M, Naert I, van 5teenberghe D, Dekeyser C, Callens A. Periodontal aspects of osseointegrated fixtures supporting a partial bridge. An up to 6 years retrospective study. J Clin Periodontol 1992;19:118-126 https://doi.org/10.1111/j.1600-051X.1992.tb00450.x
- Balshi TJ, Hernandez RE, Pryszlak MC, Rangert BO. A comparative study of one implant versus two replacing a single molar. Int J Oral Maxillofac Implants 1996;11:372-378
- Lekholm U, van Steenberghe D, Herrmann I, Bolender C, Folmer T,Gunne J. Osseointegrated implants in the treatment of partially edentulous jaws: a prospective 5-year multicenter study. Int J Oral Maxillofac Implants 1994;9:627- 635
- Babbush CA, Shimura M. Five-year statistical and clinical observations with the IMZ two-stage osteointegrated implant system. Int J Oral Maxillofac Implants 1993;8:245-253
- Adell R, Eriksson B, Lekholm U, Branemark PL Jemt T. Long-term follow up study of osseointegrated implants in the treatment of totally edentulous jaws. Int J Oral Maxillofac Implants 1990;5: 347-359
- Naert I, Quirynen M, van Steenberghe D, Darius P. A study of 589 consecutive implants supporting complete fixed prostheses. Part II: prosthetic aspects. J Prosthet Dent 1992;68:949-956 https://doi.org/10.1016/0022-3913(92)90557-Q
- Jemt T, Lekholm U. Oral implant treatment in posterior partially edentulous jaws: a 5-year followup report. Int J Oral Maxillofac Implants 1993;8:635-640
- Jemt T, Linden B, Lekholm U. Failure and complications in 127 consecutively placed fixed partial prostheses supported by Branemark implants: from prosthetic treatment to first annual checkup. Int J Oral Maxillofac Implants 1992;7:40-44
- Gunne J, Jemt T, Linden B. Implant treatment in partially edentulous patients: a report on prostheses after 3 years. Int J Prosthodont 1994;7:143-148
- van Steenberghe D, Lekholm U, Bolender C, Folmer T, Henry P, Herrmann I, et al. Applicability of osseointegrated oral implants in the rehabilitation of partially edentulism: a prospective multicenter study on 558 fixtures. Int J Oral Maxillofac Implants 1990;5:272-281
- Piattelli A, Piattelli M, Scarano A, Montesani L. Light and scanning electron microscopic report of four fractured implants. Int J Oral Maxillofac Implants 1998;13:561-564
- Morgan MJ, James DF, Pilliar RM. Fractures of the fixture component of an osseointegrated implant. Int J Oral Maxillofac Implants 1993;8:409-414
- McGlumphy EA, Robinson DM, Mendel DA. Implant superstructures: a comparison of ultimate failure force. Int J Oral Maxillofac Implants 1992;7:35-39
- Balfour A, O'Brien GR. Comparative study of antirotational single tooth abutments. J Prosthet Dent 1995;73:36-43 https://doi.org/10.1016/S0022-3913(05)80270-7
- Wiskott HW, Belser UC. Lack of integration of smooth titanium surfaces: a working hypothesis based on strains generated in the surrounding bone. Clin Oral Implants Res 1999;10:429-444 https://doi.org/10.1034/j.1600-0501.1999.100601.x
- Meijer HJ, Starmans FJ, Steen WH, Bosman F. Loading conditions of endosseous implants in an edentulous human mandible: a three-dimensional finite element study. J Oral Rehabil 1996;23:757-763 https://doi.org/10.1046/j.1365-2842.1996.d01-185.x
- Quirynen M, Naert I, van Steenbergh D. Fixture design and overload influence marginal bone loss and fixture success in the Branemark system. Clin Oral Implants Res 1992;3:104-111 https://doi.org/10.1034/j.1600-0501.1992.030302.x
- Burguete RL, Johns RB, King T, Patterson EA. Tightening characteristics for screwed joints in osseointegrated dental implant. J Prosthet Dent 1994;71:592-599 https://doi.org/10.1016/0022-3913(94)90443-X
- Patterson EA, Johns RB. Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants. Int J Oral Maxillofac Implants 1992;7:26-33
- Larson F, Bland B, Beaty K, Heylmun T. Relation between titanium alloy properties and dental implant fatigue strength. J Dent Res 1995;74(special issue):112
- Tagger GN, Machtei EE, Horowitz J, Peled M. Fracture of dental implants: Literature review and report of a case. Implant Dent 2002;11:137-143 https://doi.org/10.1097/00008505-200204000-00014
- Chun-Li Lin, Jen-Chyan Wang. Nonlinear finite element analysis of a splinted implant with various connectors and occlusal forces. Int J Oral Maxillofac Implants 2003;18:331-340
- Merz BR, Hunenbart S, Belser UC. Mechanics of the implant-abutment connection: an 8-degree taper compared to a butt joint connection. Int J Oral Maxillofac Implants 2000;15:519-526
- Tan KB, Nicholls JI. Implant-abutment screw joint preload of 7 hex-top abutment systems. Int J Oral Maxillofac Implants 2001;16:367-377
- Griffith HT. Suggested tightening torques for structural bolts. Fastener Technology / February 1987
- Lang LA, Kang B, Wang RF, Lang BR. Finite element analysis to determine implant preload. J Prosthet Dent 2003;90:539-546 https://doi.org/10.1016/j.prosdent.2003.09.012
- Martin WC, Woody RD, Miller BH, Miller AW. Implant abutment screw rotations and preloads for four different screw materials and surfaces. J Prosthet Dent 2001;86:24-32 https://doi.org/10.1067/mpr.2001.116230
- Mericske-Stem R, Piotti M, Sirtes G. 3-D in vivo force measurements on mandibular implants supporting overdentures: a comparative study. Clin Oral Implants Res 1996;7:387-396 https://doi.org/10.1034/j.1600-0501.1996.070413.x
- Kikuchi M, Takada Y, Kiyosue S, Yoda M, Woldu M, Cai Z et al. Mechanical properties and microstructures of cast Ti-Cu alloys. Dent Mater 2003;19:174-181 https://doi.org/10.1016/S0109-5641(02)00027-1
- Zavanelli RA, Pessanha Henriques GE, Ferreira I, De Almeida Rollo JM. Corrosion-fatigue life of commercially pure titanium and Ti-6Al-4V alloys in different storage environments. J Prosthet Dent 2000;84:274-279 https://doi.org/10.1067/mpr.2000.108758
- Cantwell A, Hobkirk JA. Preload loss in gold prosthesis-retaining screws as a function of time. Int J Oral Maxillofac Implants 2004;19:124-132
- Yokoyama K, Ichikawa T, Murakami H, Miyamoto Y, Asaoka K. Fracture mechanisms of retrieved titanium screw thread in dental implant. Biomaterials 2002;23:2459-2465 https://doi.org/10.1016/S0142-9612(01)00380-5
- Bickford JH. An introduction to the design and behavior of bolted joints. New York: Marcel Decker, 1981
- Haack JE, Sakaguchi RL, Sun T, Coffey JP. Elongation and preload stress in dental implant abutment screws. Int J Oral Maxillofac Implants 1995;10:529-536
- Akpinar I, Demirel F, Parnas L, Sahin S. A comparison of stress and strain distribution chracteristics of two different rigid implant design for distal extension fixed prosthesis. Quintessence Int 1996;27:11-17
- Holmgren EP, Seckinger RJ, Kilgren LM, Mante F. Evaluating parameters of osseointegrated dental implants using finite element analysis a two dimensional comparative study examining the effects of implant diameter, implant shape, and load direction. J Oral Implantol 1998;24:80-88 https://doi.org/10.1563/1548-1336(1998)024<0080:EPOODI>2.3.CO;2
- Sethi A, Kaus T, Sochor P. The use of angulated abutments in implant dentistry: five year clinical results of an ongoing prospective study. Int J Oral Maxillofac Implants 2000;15:801-810
- Himmlova L, Dostalova T, Kacovsky A Konvickova S. Influence of implant length and diameter on stress distribution: A finite element analysis. J Prosthet Dent 2004;91:20-25 https://doi.org/10.1016/j.prosdent.2003.08.008
- Davarpanah M, Martinez H, Tecucianu JF. Apicalcoronal implant position: recent surgical proposals. technical note. Int J Oral Maxillofac Implants 2000;15:865-872
- Meijer HJ, Starmans FJ, Steen WH, Bosman F. Loading conditions of endosseous implants in an edentulous human mandible: a three dimensional finite element study. J Oral Rehabil 1996;23:757-763 https://doi.org/10.1046/j.1365-2842.1996.d01-185.x
- Holmes DC, Loftus JT, Influence of bone quality on stress distribution for endosseous implants. J Oral Implantol 1997;23:104-111
- Smith EL, Raab DM. Osteoporosis and physical activity. Acta Med Scand 1996; 711(Suppl):149-156
- Papavasiliou G, Kamoisiora P, Bayne SC, Felton DA. Three-dimensional finite element analysis of stressdistribution around single tooth implants as a function of bony support, prosthesis type, and loading during function. J Prosthet Dent 1996;76:633-640 https://doi.org/10.1016/S0022-3913(96)90442-4
- Jung YC, Han CH, Lee KW. A 1-year radiographic evaluation of marginal bone around dental implants. Int J Oral Maxi-llofac Implants 1996;11:811-818
- Bragger U. Use of radiographs in evaluating success, stability and failure in implant dentistry. Periodontol 2000 1998;17:77-88 https://doi.org/10.1111/j.1600-0757.1998.tb00125.x
- Cochran DL, Nummikoski PV, Higginbottom FL, Hermann JS, Makins SR, Buser D. Evaluation of an endosseous titanium implant with a sandblasted and acid-etched surface in the canine mandible: radiographic results. Clin Oral Implants Res 1996;7:240-252 https://doi.org/10.1034/j.1600-0501.1996.070306.x
- Kitamura E, Stegaroiu R, Nomura S, Miyakawa O. Biomechanical aspects of marginal bone resorption around osseointegrated implants: considerations based on a three-dimensional finite element analysis. Clin Oral Implants Res 2004;15:401-412 https://doi.org/10.1111/j.1600-0501.2004.01022.x
- Tada S, Stegaroiu R, Kitamura E, Miyakawa O, Kusakari H. Influence of implant design and bone quality on stress / strain distribution in bone around impla-nts: a 3-dimensional finite element analysis. Int J Oral Maxillofac Implants 2003;18:357-368
- Van Oosterwyck H, Duyck J, Vander Sloten J, Van der Perre G, De Cooman M, Lievens S et al. The influence of bone mechanical properties and implant fixation upon bone loading around oral implants. Clin Oral Implants Res 1998;9:407-418 https://doi.org/10.1034/j.1600-0501.1996.090606.x
- Frost HM. Wolff's Law and bone's structural adaptations to mechanical usage: an overview for clinicians. Angle Orthod 1994; 64:175-188
- Albrektsson T, Sennerby L. State of the art in oral implants. J Clin Periodontol 1991;18:474-481 https://doi.org/10.1111/j.1600-051X.1991.tb02319.x
- Duyck J, Ronold HJ, Van Oosterwyck H, Naert I, Vander SJ, Ellingsen JE. The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: an animal experimental study. 2001; 12:207-218 https://doi.org/10.1034/j.1600-0501.2001.012003207.x
- Quirynen M, Naert I, van Steenberghe D, Nys L. A study of 589 consecutive implants supporting complete fixed prostheses. Part I: periodontal aspects. J Prosthet Dent 1992;68:655-663 https://doi.org/10.1016/0022-3913(92)90383-L
- Hansson S. The implant neck: smooth or provided with retention elements. A biomechanical approach. Clin Oral Implants Res 1999;10:394-405 https://doi.org/10.1034/j.1600-0501.1999.100506.x
- Lindquist LW, Carlsson GE, Jemt T. A prospective 15 year follow up study of mandibular fixed prostheses supported by osseointegrated implants. Clinical results and marginal bone loss. Clin Oral Implants Res 1996;7:329-336 https://doi.org/10.1034/j.1600-0501.1996.070405.x
- Lindquists LW, Rockler B, Carlsson GE. Bone resorption around fixtures in edentulous patients treated with mandibular fixed tissue integrated prostheses. J Prosthet Dent 1988;59:59-63
- Geng JP, Tan KB, Liu GR. Application of finite element analysis in implant dentistry: A review of the literature. J Prosthet Dent 2001;85:585-598 https://doi.org/10.1067/mpr.2001.115251