• Title/Summary/Keyword: fire-fighting

Search Result 488, Processing Time 0.029 seconds

Impact of Fire Demand on Fire Service Budget (소방수요가 소방예산에 미치는 영향)

  • Lee, Wonjoo;Lim, Jae Hoon;Moon, Kwang Min
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.125-134
    • /
    • 2020
  • This paper aimed to statistically analyze the impact of fire needs not considered in previous reports based on preventive and preparedness strategies of fire administration and fire budget.. The panel data came from 16 metropolitan councils from 2008 to 2018 and was statistically analyzed based on the preventive measures of the fire administration (agreement for building permission, specific target for fire-fighting, public use facilities, and special fire inspection [SFI]), preparedness of the fire administration (fire safety education [FSE]), response of the fire administration (mobilization for fire suppression [MFS] and mobilization for ambulance service [MAS]), and fire budget. In the results, SFI, FSE, and MFS had a significant negative influence on the fire budget. Meanwhile, MAS had a significant positive effect on the fire budget (p < 0.01). These results reflect public policy in Korea; there has been a paradigm shift in fire administration: from disaster acceptance (focusing on recovery) to disaster response (focusing on field response) to disaster preparedness (focusing on preparedness).

The effect that Preventive Safety Guidance from the relevant administrative agency relevant to apartment house have on fire correspondence (공동주택의 관계기관 예방안전지도가 화재대응에 미치는 영향)

  • Kim, Jong-Nam;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.2
    • /
    • pp.369-386
    • /
    • 2020
  • The purpose of this study is to examine causality closely about the mediating effect of management entity's self-checking between effects that not only mobilization for regular patrol of the relevant administrative agency, but also checking for Preventive Safety Guidance have on fire correspondence. The results of the analysis are as follows: First, not only mobilization for regular patrol of the relevant administrative agency, but also preventive safety guidance all together have been revealed to have an positive effect on management entity's self-checking. Results of these analysis have been revealed that the more not only the number of mobilization for regular patrol of the relevant administrative agency, but also the numbers of preventive safety guidance and fire fighting safety supervisor's self-checking are many, the more capability of not only management entity, but also fire fighting safety supervisor's self checking heighten. Second, not only mobilization for regular patrol of the relevant administrative agency, but also checking investigation for preventive safety guidance have been revealed to have an positive effect on fire correspondence. Results of these analysis have been revealed that the more not only the number for regular patrol of the relevant administrative agency, but also the number of fire fighting safety supervisor's checking times for preventive safety guidance are many, the more fire correspondence for the apartment house are being fulfilled much better. Finally, it has been found that both mobilization for regular patrol of the relevant administrative agency and management entity's self-checking have an effect on fire correspondence. Therefore, the effect that the relevant administrative agency's mobilization for regular patrols and preventive safety guidance, and management entity's self-checking have on fire correspondence was analyzed into what the relevant administrative agency's mobilization for regular patrols and preventive safety guidance is not only significant to do self-checking of management entity at the first stage, but also the relevant administrative agency's mobilization for regular patrols, and preventive safety guidance, and management entity's self-checking have an mediating effect in the relation between influences that have on fire correspondence.

A Study on the State of Utilizing Fire Facility in Fire Fighting (소방시설의 화재진압 활용실태에 관한 연구)

  • Lee, Chang-Seop
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.144-148
    • /
    • 2011
  • In this study I investigated that fire fighters utilize fire facilities properly or not, and found problems and solutions with interview and questionnaire. Fire fighters tend to utilize portable instruments. 62% of fire fighters have used fire facilities which is installed in building. The most useful facility is indoor fire hydrant, 42% of fire fighters have used that. The primary reason to avoid to use facility is that they think the facilities are not good at quick response. Almost fire fighters want improvement to enhance utilizing fire facilities. Finally in the fire scene, commander's initiative, fire fighter's ability, easiness of utilizing fire facilities, and fire fighter's creditibility about fire facilities are related to the degree of utilizing fire facilities.

Optimization Method for Patient Placement by Floor in Elderly Care Hospital for Evacuation Safety (피난안전성을 위한 요양병원의 층별 환자배치에 대한 최적화방안)

  • Lee, Hong-Sang;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.3
    • /
    • pp.43-51
    • /
    • 2020
  • This study analyzed the appropriate placement method by floor for evacuating all occupants during the nighttime through evacuation simulation. The analysis results are as follows. First, when non-self evacuating patients were placed on the first floor, 266 patients and 6 workers were found to be evacuated after 460 seconds. This result shows that it is meaningful to place non-self evacuating patients on the lower floor with a time that is faster than 540 seconds, which is an evaluation criterion set using life Safety standards for human. This result is a time faster than the evaluation criteria of 540 seconds, which is set using the life safety standards, and it can be confirmed that it is meaningful to place non-self evacuating patients on the lower floor. Next, as a result of placing non-self evacuating patients from the first floor to the fourth floor, it was found that evacuation of all occupants required 460 seconds for the first floor, 834 seconds for the second floor, 1,508 seconds for the third floor, and 1,915 seconds for the fourth floor. These results indicate that the placement of non-self evacuating patients on the rest of the floors, except for the first floor, can lead to dangerous results in excess of 540 seconds, which is a flashover time. As a result, it is necessary to place non-self evacuating patients on a lower floor for safe evacuation. The study has limitations except for comparative analysis of changes in evacuation time due to changes in the number of workers at eldery care hospitals and situations in which fire-fighting facilities such as sprinkler facilities operated. It is necessary to study the evacuation time linked to the operation of the fire-fighting facilities and the evacuation time according to the change in the number of workers in the future.

Development of an AVL System for Fire Fighting Services (소방용 AVL 시스템 개발)

  • Kim, Dong-Yong;Moon, Sang-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.4
    • /
    • pp.886-892
    • /
    • 2010
  • It is possible to use wireless communication any time in every place because of well-developed wireless networks and mobile devices. The AVL(Automatic Vehicle Location) system, therefore, has made practical use in situation control, distribution industry, home delivery service, and ITS(Intelligent Transportation System) area. In this paper, we design and implement an AVL system in order to use for fire fighting activities such as emergency rescue and relief. To do this, first, we investigate and analyze the existing researches and systems related to AVL system. In details, we develop an AVL server and clients to support stable communication each other using wireless networks. Using AVL system, calling cars find the position of accidents quickly and the fire defense headquarters control unforeseen accidents efficiently because the state of calling cars are confirmed in real time by their GPS data.

A Study on Fireproofing Application by Fire Magnitude (화재규모에 따른 화학공장의 내화구조 적용에 대한 연구)

  • Lee, Dong Hyeok;Yoo, Byung Tae
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.5
    • /
    • pp.46-52
    • /
    • 2018
  • Interest in fire prevention/fighting has been increased by large fire. It is important to install/manage the detector, alarm, firefighting facility, evacuation route and so on to minimize the damage from fire. Chemical plant is generally constructed by steel structure. So fireproofing is significantly required to chemical plant because steel structure should endure during fire. Currently, fireproofing should be applied up to 6m from ground by local regulation. But chemical plant can handle the large amount of flammable materials or only non-flammable materials. Required of fireproofing height by fire magnitude is studied in this thesis.

Fire-Resistance Characteristics of Shield Tunnel Concrete Linings (쉴드터널 콘크리트 라이닝의 내화특성)

  • Park Hae Geun;Lee Myeong Sub;Jeon Sang Eun;Park Dong Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.32-35
    • /
    • 2004
  • In recent years a number of catastrophic tunnel fires, the Euro tunnel, the Mont Blanc tunnel, the Tauem tunnel and the Gotthard tunnel, have occurred and inflicted serious damages to European countries. If a fire occurs in shield tunnels, the reinforced concrete segment linings playing as an important structural member is expected to damage severely and finally can be caused the collapse of tunnel. The purpose of this study is to evaluate the performance of concrete segment lining under heat exposure and to obtain information to assist a new technical approach to fighting fires in tunnels. In order to evaluate the fire-resistance performance of concrete segment by adding Polypropylene fibers, fire tests using the RABT heat-load curve is carried out. The temperature rise of this curve is very rapid up to $1200^{\circ}C$ within 5 minutes, and duration time of the $1200^{\circ}C$ exposure is 55 minutes. From the fire test, it was found that the explosive spalling was rapidly reduced by adding polypropylene fibers and this method is considered as an effective fireproof material to upgrade fire safety in tunnels economically.

  • PDF

A Study on the Recognition of Fire Construction Surveillance System : Focused on the Stakeholders (소방공사감리제도의 인식에 관한 연구 : 이해당사자를 중심으로)

  • Lee, Ranny;Jeong, Kyeon-Sik;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.3
    • /
    • pp.133-143
    • /
    • 2014
  • The purpose of this article is to search stakeholders' recognition related to Fire Construction Surveillance system; a client(order), fire fighting officer, supervision company, construction company, design company, other. The paper provides 4 important things. Firstly, a client(order) suggested the lowest recognition in the needs about the need of separation order, that of contract for any construction work limited registered companies, and that of standard price for engineering.. Secondly, the design company is lowest recognition in guidance and control participating in construction-design phase. Thirdly, the design company is lowest in adjustment about manpower-allocation according to allocation criteria of technical manpower. Fourthly, a client(order) and supervision company are relatively lower than other stakeholder in necessity on special education and training system for auditor in fire protection construction. Almost all related matters are related to more or less stakeholders' interest.

Performance Evaluation of Image Saturation of Thermal Imaging Camera for the Fire Service (화재용 열화상 카메라의 영상포화특성 평가)

  • Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.69-74
    • /
    • 2012
  • Thermal imaging technology based on IR sensor with high transmittance through the fire smoke is considered as one of the advanced technology for the fire service. The present study has been performed to investigate the image saturation characteristics with thermal condition of target and background and evaluate the performance of image quality based on the contrast transfer function (CTF). For the present testing conditions, TIC using BST sensor did not show the image saturation and the image quality based on the CTF was proportional to the temperature difference between target and background. This study can be utilized as preliminary study to improve reliability and technical development of TIC.

Analysis of traffic accidents involving 119 emergency (119 구급대 구급차 교통사고 현황 분석)

  • Lee, Jeong-Ho;Shin, Dong-Min
    • The Korean Journal of Emergency Medical Services
    • /
    • v.22 no.1
    • /
    • pp.35-47
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate both the occurrence status of emergency vehicles traffic accidents and contents of the experiences of emergency medical technicians (EMTs) in fire station. Methods: A self-reported questionnaire was completed by 451 EMTs in fire stations in 6 cities provinces from February 9, 2017 to February 27, 2017. Results: Of 451 EMTs, 207 (45.9%) had traffic accidents experience. Regarding environment-related features, results indicated hour (12~18 hours), place (national highway), traffic flow (smooth), weather (clear), season (winter), and day (Friday). Regarding correlation analysis of differences in the number of ambulance traffic accidents pursuant to general features of accident-experienced drivers as a human factor, there were no significant differences in recruitment, driving careers of regular cars, driving careers of fire engines, and class but there were significant differences in fire-fighting careers. Accident experience in the group with careers over 6 years and less than 10 years higher than in the other groups. Conclusion: Efforts to expand fire engine driving education programs for the prevention of traffic accidents involving 119 emergency vehicles are required.