• Title/Summary/Keyword: fire resistance test

Search Result 390, Processing Time 0.033 seconds

Study on Long-term Performance of Phenolic Foam Insulation through Accelerated Aging Test (가속화 시험을 통한 페놀폼 단열재의 장기성능 비교분석에 관한 연구)

  • Kim, Jin-Hee;Kim, Sang-Myung;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.2
    • /
    • pp.11-23
    • /
    • 2020
  • The application of the high-performance insulation materials for buildings seems to be an essential measure for reducing energy use in buildings. Phenolic foam is a readily available insulation material with thermal conductivity of about 0.018 to 0.020 W/(mK). It has the advantage of higher thermal resistance and better fire resistance compared to other conventional building insulation materials. Insulation material used for building envelope is regarded as one of the decisive factors for building's energy load. Furthermore, the degradation of its thermal performance over time increasingly affects the building's energy use demand. Generally, the life span of conventionally built buildings is expected to be more than 50 years, so the long-term performance of insulation materials is critical. This paper aims to evaluate the long-term performance of phenolic form boards through an accelerated aging test. The tests were conducted according to BS EN 13166 and KS M ISO 11561. Based on the results of the accelerated aging test, the thermal performance variation of the material was analyzed, and then its aged value after 25 years was computed. Also, the characteristics of the phenolic foam board's long-term performance were also examined based on the standard testing methods adopted.

The improvement of quantification method of toxic gas components from the materials of the railway vehicle (철도차량용 재료의 독성성분 정량화 향상기법 연구)

  • Lee, Cheul-Kyu;Jung, Woo-Sung;Lee, Duck-Hee;Lee, Kwan-Sub;Park, Ji-Young
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1314-1317
    • /
    • 2007
  • This study is on the fire resistance evaluation method, expecially on the toxicity of smoke gases generated from the fire, of materials for railway car and structures. Until now, Although international standard related to the quantifying evaluation method of smoke gas is provided but the specific procedure is not contained. On this reason, Test results of toxicity show deviation with the different technique being applied. For now, In advanced railway country, various instrument, like ion chromatography and etc., is used but FT-IR is recommended due to its lots of advantages. while FT-IR has a lot of strong points but still has some problems like water vapor interferences. In this paper, To improve credibility and repeatability of FT-IR it contains some technical solutions in quantifying the 8 toxic components.

  • PDF

Density and Strength Properties according to the Paper Ash addition ratio of the Lightweight Composite Panel Core Using the Blast Furnace Slag and Polysilicon Sludge (고로슬래그와 폴리실리콘 슬러지를 활용한 경량복합패널 심재의 제지애시 첨가율에 따른 밀도 및 강도특성)

  • Lim, Jeong-Geun;Lee, Ji-Hwan;Park, Hee-Gon;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.152-153
    • /
    • 2015
  • Recently, solar energy generation is one of the fastest growing industries for eco-friendly energy. Every year, solar energy generation industry grows to 42% on average. However, polysilicon sludge is generated from processing of polysilicon but, there is nothing to handle that. Therefore, we need research to recycle polysilicon sludge. Also, improved fire resistance efficiency of wall is required according to reinforced fire safety standards due to many cases of big fires in our country. This study focuses on density and strength properties according to the addition ratio of paper Ash for the lightweight composite panel core with polysilicon sludge. As a result of the test, adding paper ash 9% has the best density and strength properties.

  • PDF

Properties of Fire Resistance of High Performance Concrete Using Cellulose Fiber (셀룰로오스 섬유를 사용하는 고성능 콘크리트의 내화특성)

  • Kim Kyoung Min;Joo Eun Hi;Hwang Yin Seong;Jee Suk Won;Lee Seong Yeun;Han Cheon Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.557-560
    • /
    • 2004
  • This paper is to investigate the fire endurance of high performance concrete with the contents of cellulose fiber. According to test results, the use of CL lead to decrease in fluidity. For compressive strength, the use of CL had no influence on compressive strength. For spalling properties, plain concrete showed a severe spalling failure. The use of CL protected from spalling of concrete, but most specimens had scale failure and partial destruction of specimens. This is due to the insufficient fiber length and diameter of CL fiber, which was unable to discharging the internal vapour pressure. For this reason, CL fiber can not be used to protect from spalling oh high performance concrete. Residual strength was observed to $5\~7\%$ of original strength.

  • PDF

An Experimental Study on The Fire Resistance Performance and Spalling of 100 MPa HSC Column Mixed Fiber-Cocktail (Fiber-Cocktail 섬유를 혼입한 100 MPa 고강도 콘크리트의 단면크기에 따른 폭렬 및 내화성능에 관한 실험적 연구)

  • Kim, Hyung-Jun;Kim, Heung-Yonl;Park, Kyung-Hoon;Yeo, In-Hwan;Kwon, Ki-Hyuck
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.85-92
    • /
    • 2011
  • Along the fire resisting capacity of high strength concrete has been brought up as a social issue, and the Ministry of Land also had notified the control standard about it, the researches for improving the fire resisting capacity have been considerably activated these days. In this study, we performed a research for developing a high strength concrete, contains the fiber cocktail, which is a hybrid of polypropylene fiber as organic matter, and steel fiber. As we analyzed the temperature of the steel part during the fire test with 100 MPa high strength concrete, there was a tendency that the lower temperature comes out with the larger cross section, and the $600{\times}600mm$, $800{\times}800mm$ cross sectioned can secure the fire resistance capability, so the $600{\times}600mm$ is deducted as the optimal size if we consider the double economic feasibility. As well, among them the best qualified $600{\times}600mm$ shapes, the fiber cocktail hybrid of $1.5kg/m^3$ PP fiber and $40kg/m^3$ of steel, comes out the best ratio.

Physical Properties of Cement Boards Mixed Pearlite and Expanded Graphite (펄라이트와 팽창흑연을 혼입한 시멘트 보드의 물리적 특성)

  • Lee, Ju-Won;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.65-66
    • /
    • 2023
  • Recently, the importance of improving air quality has been greatly highlighted due to environmental problems such as indoor air pollution, and efforts are being made to improve indoor air quality not only in Korea but also around the world. In this situation, this study aims to study the physical properties of cement boards using pearlite with excellent physical adsorption performance due to micropores in materials, expanded graphite that is widely used as a flame retardant to prevent heat transfer in the event of a fire. The experimental items are bending fracture load and impact resistance. The bending destruction load at the fiber mixing rates 1, 2, 3, and 4 (%) did not meet the standard 140N, but the bending destruction load at 5% was 168.2N, and the impact resistance of the fiber mixing rates 1 and 2 (%) could not be measured due to cracks and damage, and the impact resistance at 3, 4, and 5 (%).

  • PDF

Development of Damage Estimation Method using Sensor of Multiple Function in RC Beam (철근 콘크리트 보에서의 다기능 센서를 이용한 손상 추정법 개발)

  • Kim, Ie-Sung;Park, Kang-Geon;Kim, Wha-Jung
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.184-188
    • /
    • 2008
  • Performance degradation of concrete structures is generally caused by structural deteriorations, such as cracks. It may result in serious defects of concrete structures. Methods of damage detection are used a visual angle of human or non-destructive test, and they are using various sensors. Problems of crack damage detection are occurred to directions of cracks by using 1 axial type of accelerometer in concrete element. In addition, these sensors are not used to occurring fire in RC building. Thermocouple sensors are able to using measurement of temperature in fire, and then deformations of main element and structures are not used. In this study, fundamental studies for development of multiple function sensor using 3 axial type of accelerometer and electric resistance property of thermocouple sensors are discussed estimation to stability of structures when happened form active load or fire, and so on.

  • PDF

The Study of analysis and test for crash survival about the Crash Protected Module in Black Box used at aircraft (항공기용 블랙박스의 자료보호모듈 극한환경해석 및 시험에 관한 연구)

  • Lee, Sock-Kyu;Lee, Byoung-Ho;Choi, Ji-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.1
    • /
    • pp.61-68
    • /
    • 2012
  • The purpose of Crash Protected Module in Black Box used at aircraft is to protect a stored information(Flight data & Cockpit Voice) safely even after extreme environment like a plane crash. This study shows the structure & thermal analyses and the comparisons of predictions and results of tests about CPM for Crash Survival through extreme environment such as Penetration Resistance, High Temperature Fire, Low Temperature Fire. Specially, the Effect of housing thickness change was studied through the Penetration Resistance analysis using LS-DYNA, and the influence of volume ratio change between phase change material and thermal insulation material was studied through the High Temperature & Low Temperature analysis using Icepak. Also, structural and thermal reliability of CPM was validated through the tests.

A Study on the Development of Simulating Tool for Evaluation of Electrostatic Discharge (정전기 방전 평가를 위한 간이형 도구 개발에 관한 연구)

  • Choi, Sang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.3
    • /
    • pp.15-22
    • /
    • 2011
  • Explosion and fire cause about 30 reported industrial major accidents a year by ignition source which discharge of electrostatic generated to flammable gas, vapor, dust and mixtures. It brings economically and humanly very large loss that accident was caused by fire and explosion from electrostatic discharge. Thus, it is very important that electrostatic discharge energy is to be control below not to be igniting flammable mixtures. There are two kinds of analysis model for electrostatic discharge, human body model and machine model. Human body model is available the parameter of human's electrical equivalent that capacitance is 100 pF, resistance is $1.5k{\Omega}$. To simulate and visualize the electrostatic discharge from human body need a very expensive and high voltage simulator. In this paper, we measured the value of capacitance and resistance concerned with test materials and sizing of specimen and the value of charged voltage concerned with test specimen and distance to develop an electrostatic charge/discharge simulating tool for teaching with which concerned industrial employee and students. The result of experiments, we conformed that the minimum ignition energy of methane-oxygen mixtures meets well the equation $W=1/2CV^2$, and found out that the insulating material and sizing of equivalent value having human body mode are the poly ethylene of 200 mm and 300 mm of diameter. Developed electrostatic charge/discharge simulating tool has many merits; simple mechanism, low cost, no need of electric power and so on.

Penetration Fracture Characteristics of Orthotropic CFRP Laminates Shells according to Curvature (곡률이 다른 직교이방성 CFRP 적층쉘의 관통파괴특성)

  • Yang, Yong Jun;Pyeon, Seok Beom;Cha, Cheon Seok;Yang, In Young
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.6
    • /
    • pp.6-11
    • /
    • 2016
  • CFRP composite laminates are widely used as structural materials for airplanes, automobile and aerospace vehicles because of their high strength and stiffness. This study aims to examine an effect of curvature on the penetration fracture characteristic of an orthotropic composite laminated shell. For the purpose, we manufactured orthotropic CFRP shell specimen with different curvatures, and conducted a penetration test using an air-gun. Those specimens were prepared to varied curvature radius(${\infty}$, 200mm, 150mm and 100mm)and were stacked to $[O^{\circ}{_3}/90^{\circ}{_3}]_s$. When the specimen is subjected to transverse impact by a steel sphere(${\Phi}10$), the velocity of steel sphere was measured both before and after impact by determining the time for it to pass two ball-screen sensors located a known distance apart. As the curvature increases, the absorption energy and the critical penetration energy increased linearly because the resistance to the bending moment. Patterns of cracks caused by the penetration of CFRP laminated shells included fiber breakage, lamina fracture, matrix crack interlaminar crack and intralaminar crack.